| 1 | Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. |
| 2 | M& L for Surface dressing n.exc. 15 cm deepin soft/loose soil.complete all as specified and as directed. |
| 3 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 4 | Excavating over areas, n exc 1.5 m deep and getting outi soft siol complete all as specified and directed |
| 5 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed. |
| 6 | Removing excavated Material (Soil) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed. |
| 7 | M&L Hardcore of gauge not exc. 63 mm, broken boulders aggregate deposited, spread andlevelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed. |
| 8 | M&L Sand filling under floors or in founda-tions including watering and consolidation, complete all as specified and as directed. |
| 9 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 10 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed. |
| 11 | M&L for 100 mm PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in sub base laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 12 | M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in copping and the like including weathring, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 13 | M&L Cement Concretetype C2(1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 14 | M&L P.C.C (1:3:6) type C2 using 40 mm graded stone aggregate for bed to drain pipes including packing under and hunching against side of pipes after they are laid down and tested complete for 150 mm bore pipe complete all as specified and as directed. |
| 15 | M&L for RCC M-25 (20mm graded aggregate)as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, underremaed pliles and mass concrete complete all as specified and as directed. |
| 16 | M&L for RCC M-25using 20mm graded aggregate as columns pillars, piers posts,lintal beam,roof beam complete all as specified and as directed. |
| 17 | M&L for RCC M-25 (20 mm graded stone aggregate) in RCC Chajjas,completer all as specified and directed.. |
| 18 | M&L for RCC M-25 (20 mm graded stone aggregate) in RCC lintel, band etc completer all as specified and directed.. |
| 19 | M&L for RCC M 25 (design mix) as in slabs supported on walls, beams and columns in floors, roofs landings, balconies, canopies, deck slabs and in shelvesand similar works completer all as specified and directed. |
| 20 | M&L for RCC M-25 (20 mm graded stone aggregate) in RCC Roof beam,completer all as specified and directed. |
| 21 | M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 22 | Mild steel bars 5mm to 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 23 | M&L Formwork toSoffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 24 | M&L Formwork to Sides of Concrete Founda-tions, Footings, bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of foundation and plinth beams and similar work; Square, rectangular or polygonal, vertical or to batter, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 25 | M&L Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 26 | M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 27 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 28 | M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 29 | M&L Rendering 15mm thick in Cement Mortar 1:4 (Externally) on Fair Faces of Brick Walls or on Concrete Surfaces including mixing with WPC as per manufacturer\"s instructions, Plastered Surfaces finished Even and Smooth without using extra Cement, complete all as specified and as directed. |
| 30 | M & L, 10mm thick rendering in C.M. (1:6) on brick workfinished even and fair without using extra cement complete all as specified and as directed. |
| 31 | M&L Rendering 5 mm thick in patches with CM (1:3) on ceiling Complete all as specefied and directed. |
| 32 | Supply only water proofing compound. Conforming to IS -2645 complete all as specified and as directed. |
| 33 | S&F 1st class HW (Teak wood) Plain, solid, straightchowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints, complete all as specified and directed |
| 34 | S&F 1st class HW (Teak wood) 40 mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats andif moulded bead is provided and planted round the panels (for each side) complete all as specified and directed. |
| 35 | S&F Factory Made Solid PVC Door Frame of size 50 x 47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 36 | S&F Factory Made Solid Panel PVC Door Shutter 30mm thick, consisting of frame made out of Mild Steel Tube of 19 Gauge thickness and size of 19mm x 19mm for Stiles and 15mm x 15mm for Top & Bottom Rails. Mild Steel Frame shall have a coat of Steel Primer of Approved Make and Manufacturer. Mild Steel Frame shall be covered with 5.0mm thick heat moulded PVC \"C\" Channel of size 30 x 50mm forming Stiles and 5.0mm thick, 75mm wide PVC Sheets For Top Rail, Lock Rail & Bottom Rail on either side, and 10mm (5.0mm x 2) thick, 20mm wide Cross PVC Sheet as gap insert for Top Rail, Lock Rail & Bottom Rail. Panelling of 5.0mm thick PVC Sheet Beading on either side and joined together with Solvent Cement Adhesive, etc. An additional 5.0mm thick PVC Strip of 20mm width is to be stuck on the interior side of the \"C\" Channel using PVC Solvent Adhesive, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 37 | S&F Powder coated Aluminium anodised doors, windows, partitions and ventilators using aluminium sections of size and type approved by Engineer-in-Charge including jointing cleats,snap beadingetc, completeallas specified and as directed. |
| 38 | S&F Aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 nos glazed and one wire gauzed shutter)including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for shutter (i) \"H\" section 39 x 20 x 1.50 mm thick (ii) \"Interlock\" section 39 x 20 x 1.50 mm thick (iii) \"Edge & Bottom\" section 41 x 20 x 1.50 mm thick(B) Section for frame (i) Top & Sides 123 X 29.70X 1.50mm not less than 1.30 Kg /RM(ii) Bottom 123 X 29.70 X 1.50mm not less than 1.502 Kg /RM complete all as specified and directed . |
| 39 | S& F 5.0 mm thick sheetglass ordinary/tinted/ Filmed to match exixting quality and glazing with oil putty in squaresexc 0.5 sq. m in each panein squares complete all as specified and directed. |
| 40 | S&F Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed . |
| 41 | M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed |
| 42 | S&F 6-10 mm thick PVC hollow panels with to 0.5 mm plain PVC sheet suitably placed in Wall inclding same and matching colour wall angle , u clip, end elip and jointer . As in ceiling and walls including aluminium frame work fixed to wall or wooden scantling vertically and horizontally at an interval complete all as specified and directed. |
| 43 | S&F Solid WPC particle board for cabinet consisting of 18-20 mm thick prelaminated PVCsheet inclusive of solvent cement and fixing at site complete all as spacified and directed. |
| 44 | S&F Exposed GI powder coated snap grid frame for false ceiling 600x600mm size of wall angle 25x25x0.55mm size of cross tee and main tee26x24x0.55mmand 32mm x 24mm x 0.55mmwith 3mm dia single GI adjustable suspentor including supply and fixing of 4mm thick E Board decorative type in false ceiling including fixing arrangement from steel tress any type of tress complete all as specified and as directed. (Make: E Board of approved make) |
| 45 | S &FBrass handles, cast type, polished bright 150 mm size complete all as specified and directed. |
| 46 | S & F in repairsBrass mortice lock verticle type 75 mm4/6 levers complete all as specified and directed |
| 47 | S & F 125mm Butt hinges, extruded brass with galvanised mild steel hinge pin,bright polished and fixed with SS Screw, type B-11, complete all as specified and directed |
| 48 | S&F Brass barrel tower bolts,with cast or sheet barrel and rolled or cast bolts and fixed 100mm long and fixed with screws.complete all as specified and as directed. |
| 49 | S & F continuous(Piano) hinges 30 mm width mild steel ,bright finishfixed with screw complete all as specified and directed. |
| 50 | S&F bal catches with 8 mm dia steel ball magnet catches for cuboard shutter including strking plate as approved etc completeall as specified and as directed |
| 51 | S & F 40 mm dia cupboard knob fixed with nut ,screw and washer of brass polished complete all as specified and directed. |
| 52 | M&L Glazed Ceramic tiles 8 to 10 mm thick (square/ rectangular) any shade, polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of surface over 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 53 | M&L Non- skid Ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm, in Skirting/Dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of surface over 10 mm thick rendering in CM 1:3 complete all as specified and directed. |
| 54 | M&L Glazed Ceramic tiles 8 to 10 mm thick (square/ rectangular) any shade, polished, area of each tiles not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of surface over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 55 | M&L for glazed Ceramic tiles any shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 complete in all respect as specified and directed. |
| 56 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like fixed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match over with shade of granite complete all as specified and as directed. |
| 57 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, complete all as spcified and directed. |
| 58 | S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with \"p\" or \"s\" trap front or back inletincluding fixing Bolts with and (excluding 10 litre capacity low levelFlushing Cistern)and providing 32mm dia PVC flush pipe including plastic water closet seat with flat botton cover (coloured) fixed with mild steel chromium plated or aluminium hinging device and making good disturbed Surfaces in Cement Mortar 1:3 and fixed, complete all as specified and as directed. |
| 59 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and as directed. |
| 60 | S&F Toilet paper holder of brass chromium plated fixed to walls with chromium platedbrass screw including necessary fixing arrangement as in repair complete all as specified and directed. |
| 61 | S&F Mirror Bevelled Edge 600x450mm, Selected quality Glass, mounted on 6.0mm thick AC Building Board or Commercial Ply-wood and fixed to Wooden Plugs with Chro-mium Plated Brass Screws and Cup Washers complete all as specified and as directed. |
| 62 | S&F in repair towel Rail chromium platedcomplete all as specified and directed. Make: Jaquar or Equivalent as approved by GE complete all as specified and directed. |
| 63 | S&F in repair towel ring chromium platedcomplete all as specified and directed. as approved by GE complete all as specified and as directed. |
| 64 | Supply and fix, sheet glass self assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with cromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 65 | S&F in repair vitreous china Table top Basin of approved shape & sizeincluding taps, waste chain, plug and porcelain stopper, brackets, cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. Make;-Jaguar or equivalant as approved. |
| 66 | S&F in Shower pannel of model JPL-BLK-JA011 of make Jaquar incl 750mm to 900mm long shower arm as per approval of GE complete all as specified and as directed. |
| 67 | Supply and fix, shower water drainage floor bathroom grating with CP/SS 304 Anti foul cockroach proof of size 100X600 mm all as specified and directed. |
| 68 | S&F automatic soap dispenser of capacity 0.8 ltr of aluminium/Abs with chromium finish complete all as specified and directed. as per approval approved by GE. |
| 69 | S&F Flash touch free infared hand dryer with 1150 W rated poer&carbon brush motor of stainless steel bodycomplete all as specified and directed.as per approval ,approved by GE. |
| 70 | M&L 12mm thick clear toughened glass inluding fixing stainless steel brackets, cleats and fixing accessories for frame less toughened glass fixing infixed openingas per manufacture\"s instructions and approval of garrison engineer.complete all as specified and as directed. |
| 71 | S&F PVC connections 15mm size with PTMT nut of length 450mm complete all as specified. |
| 72 | Supply and fix,as in repair, waste coupling CP 32 mm dia for glazed ware basins etc with fly nuts flanged etc complete all as specified and directed. |
| 73 | S&F 32mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and ditected |
| 74 | S&F PVC (SWR)floor trap 75 mm size with grating including jointing with solvent cement complete all as specified and as directed. |
| 75 | S&F PVC (SWR) multi floor trap 75 mm size with grating including jointing with solvent cement complete all as specified and as directed. |
| 76 | S&F PVC (SWR) 75mm bore bends any radius complete all as specified and as directed |
| 77 | Supply and fix, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor including dismantling complete all as specified and directed. |
| 78 | Supply and fix, 110 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor including dismantling complete all as specified and directed. |
| 79 | S&F PVC (SWR) 110mm bore bends any radius complete all as specified and as directed |
| 80 | S&FAngular stop cock cast copper alloy CPwith wall flange for 15mm bore,Make: Jaquar or Equivalent approved by GE complete all as specified and as directed. |
| 81 | Supply and fix, as in repairs, grating round/ Square Anti foul cockroach proof 100 mm dia size of stainless steel complete all as specified and directed. |
| 82 | S& PVC(SWR) junction single (single \"T\") equal or unequal 110mm bore complete all as specified and directed. |
| 83 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed. |
| 84 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed. |
| 85 | M&L 150 mm internal dia salt glazed stoneware drain pipes , laid in trenches and jointed as specified all as specified and as directed |
| 86 | M&L for three coats of French polishing on wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed |
| 87 | M&L Preparing new plastered surfaces of wall and appplying two coats of acrylic exterior weather coat over acoat of primer withdamp proof care andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and evenas per manufacturer instrcution and applied by approved applicatorcomplete all as specified and directed. |
| 88 | M&LApplying two coats of Plastic emulsion paint to newly plastered/previously untreated wall over a coat of primer andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 89 | M&L preparing new Surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and as directed. |
| 90 | S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 1000 Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipe including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. |
| 91 | Supply, lay and fix in repair25 mm bore galvanized iron water tubing medium grade including all fittings and fixed laid in trenches complete all as specified and directed. |
| 92 | S&F 25 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions as in repair complete as all specified and as directed. |
| 93 | Supply and fix in repair Ball valves 25 mm dia high epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 94 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(ii) cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. |
| 95 | All as per item No. 94 above but for 3 pin 5 Amps switch socket combination on independent board complete all as specified and as directed. |
| 96 | All as per item No. 94 above but for 3 pin 15 Amps switch socket combination on independent board with 2.5 sq mm copper cable complete all as specified and as directed. |
| 97 | All as per item No.94 above but for 5 Amps socket point on the same board controlled by one switch complete all as specified and as directed. |
| 98 | S&F modular switch flush type, 6 Amp, one way ,1 module complete all as specified and as directed. |
| 99 | S&F modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and as directed. |
| 100 | S&F modularswitch, 16 Amp flush type 1 module complete all as specified and as directed. |
| 101 | S&F modularsocket outlet, 3 pin, 6/16 Amp flush type 2 module complete all as specified and as directed. |
| 102 | S&F modularFan Regulator stepped type 2 module, 120W complete all as specified and as directed. |
| 103 | S&Fceiling rose surface backelitethree terminals complete all as specified and as directed. |
| 104 | S&F metal clad socket out let with MCB single pole and nutral 20-32 Amp, 240 V including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed. |
| 105 | S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 12 way with common bus bar at incomming end complete all as specified and directed |
| 106 | S & F MCB \"C\" series Single pole and nutral 40-63 Amps, breaking capacity 10KA,complete all as specified and directed |
| 107 | S & F MCB \"C\" series single pole 6 to 32 Amps, breaking capacity 10KA,complete all as specified and directed |
| 108 | Supply and fix LED tube light fitting of 18 W with tube (4 Ft) 240 V Wall mounted LED batten polycarbonate houseing and integrated electronic driver with high efficient LEDs 18 Watt with acessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories, internally pre-wired and including connection, complete all as specified and as directed. |
| 109 | Supply and fix LED Bed side light, flexible, rotatable, 3 Watt complete all as specified and as directed. |
| 110 | S&F Recessed mounted 2X2 LED luminaries 36 watt White powder coated luminaries with screw less design and bottom opening to give high aesthetic and ease of servicing including cutting the existing any type of ceiling and making the ceiling as per the existing ceiling after fixing the light fittings includingtaking down old unserviceable one complete all as specified and as directed. |
| 111 | Supply and fix for Recess/Surface mounting high lumen output LED light fittings for metallic false ceiling type armstrong/US gypsum or similar ceiling mounting system with concealed or exposed \"T\" section including 12 watt LED CDL light, complete all as specified and as directed. |
| 112 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including provision of fan hook complete all as specified and directed |
| 113 | M&L complete for pvc exhaust fan of size 250 mm sweep, single phase,230 volts Ac with louver shutter /grill and connection complete incl cutting hole and making good disturbed surface and necessary fixing arrangements complete all as specified and as directed. |
| 114 | Supply & Fix electric storage heater of 25 Ltr capacity, 5 Star in replacement with heating element 2000 W,thermostat, inlet, outlet connection pipe and air vent connections including all fixing arrangement for mounting on wall and necessary water inlet and outlet connections complete all as specified and directed. |
| 115 | M&Lfor sub main wiring withFour run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt,and two run of copper earth wire 4 Sq mm drawn through PVC conduit and all accessories, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length. |
| 116 | M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. |
| 117 | NOTES:1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule \"A\" notes for details. |