| 1 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed |
| 2 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc (Fe 410 -W (Gde E- 250) quality A complete all as specified and directed |
| 3 | M&L for preparation of new steel and ironsurfaces of any description over 10 cm width or girthand applying two coat of synthetic enamel paint complete all as specified and directed |
| 4 | DismantlingAC sheet (Corrugated, Semi Corrugatedetc)as in roofs etc includingridgescomplete all as specified. |
| 5 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick(Base metal thicknes) of any colour having tensile str of 550Mpa as in roof covering/cladding to walls,fixed with self tapping screws complete all as specified and directed |
| 6 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick(Base metal thicknes) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed |
| 8 | S&F vitrifiedceramic tilesdarkt shade digital tiles/(double charged), 10mm thick (square/ rectanglar) polished , exceeding 0.18 sqm of each tiles not exceeding 0.38 sqm, in floors etc. laid over15mm thick screed bed 1:4 , set and jointed in neat cement slurry and pointed in white/coloured cementto match complete all as specified and directed |
| 9 | M&L for non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm , in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick renderingin CM 1:6 complete all as specified and directed. |
| 10 | S&F glazed coloured ceramic digital tiles 600x300x7mmthick,set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 15 mm thick renderingin CM 1:4 as in vertical surfaces as approved. complete all as specified and directed |
| 11 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified and directed |
| 12 | M&L for cement concrete 1:3:6 type C2 , 75 mm thickas in plinth protection and flooringand finishing the surface even and smooth without using extra cement complete all as specified and directed |
| 13 | Dismantling of wall andceiling boards (fibre, pulp, insulation, etc) or insulationboards/slabs/blankets, any thickness including cover filltets complete all as specified and directed |
| 14 | M&L for Providing and fixing of E-board 600 x 600 x 4mm thick white prelaminated sett embosed reinforced desigener (lake & HM as approved ceiling board/tiles at all height laid on Armstrong Hot dipped Galvanised imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work will comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers of GI wire 4mm dia to be fixed by approved rawl plugs, level and justers and screws etc.complete all as specified and directed |
| 15 | Taking down chawkhat frame with shutter (without taking out shutter from the frame) exc 1.50 Sqm but n. exc 4 sqm each and removing from site complete all as specified and directed. |
| 16 | S&F doorchowkhats size 75x50mm single rebated factory made 100% solid WPC(Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with density not less then 780kg /Cum complete all as specified and directed |
| 17 | S&F door chowkhats size 65x100 mm single rebated factory made 100% solid WPC(Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with density not less then 780kg /Cum complete all as specified and directed |
| 18 | S&F door chowkhats size 65x125 mm double rebated factory made 100% solid WPC(Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with density not less then 780kg /Cum complete all as specified and directed |
| 19 | S&FFactorymade 30 mm thick 100% solid WPC (Wood Polymer Composite) solid prelem both side 14 micron Flushdoor shutter wit 10mm deep CNC moulding design ofrequiredsize comprising of virgin PVC resin of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 650 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 20 | S&F 30mm thick factory made solid WPC (Wood plastic composit) moulded glzed door shuter with wire mesh in 08 number of division with brown wood grain texture including SS wire mesh (G-304) 0.36 mm minimum dia of wire and average width of aperature 1.4mm with XPMAluminium alloy wire cloth of wire shall to be fixed with15x15 square tube in side rails with screwing 8x28 heat metel zink coated screws can be remove of fix again after changing of wire mesh needed. The density not less then 650kg /Cum shall be as per manufacture instruction complete all as specified and as directed |
| 21 | S&F butt hinges of size 125 mm medium weight, stainless steel ISI marked complete all as specified and directed |
| 22 | S&F200 mm longstainless steel barrel tower boltsof extruded section complete all as specified and directed |
| 23 | S&F 200 mm size stainless steel handles, fabricated type,complete all as specified and directed |
| 24 | S&F 300 mm long stainless steel, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed |
| 25 | S&F mild steel helical door spring 300 mm ordinary rat tail rod pattern spring including roller and roller plateincluding welding if required complete all as specified and directed |
| 26 | S&F framed work as in doors, gates or grill of angleor other section withgusssetplates, rails, braces etc complete drilled for fixing steel sheetings or other coverings. Doors etc to beprepared for hanging orsliding with and including either hooks orhinges steel hanging door fittings ( exclusive of steel sheeting or other coveringsrunning railsand guides) and hanging also fastening and fixing complete quality conforming to Fe-290W (Gde E-165) quality B complete all as specified and directed |
| 27 | S&F powder coatedaluminium glazed window shutter sliding type using 1.30 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rils 100x44mm including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodisedaluminium fittings complete and glazing shall be done by using 5mm thick plain sheet glassand stainless steel wire cloth 0.36 mm nominal dia of wire and averagewidth of aperture 1.40 mm complete all as specified and directed |
| 28 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete .complete all as specified and directed |
| 29 | M&L for brick work withold size fly ashbricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and directed |
| 30 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed |
| 31 | M&L for 15mm thick rendering inCM 1:4with on fair surfaces of walls finishedeven and smooth withoutusing extra cementcomplete all as specified and directed |
| 32 | M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair face of brick work of walls, finished even & smooth without using extra cement, complete all as specified and directed |
| 33 | M&L for Preparation of new plastered surface ofwall and applying two coats of OBD over a coatof 2mm thick wall care putty & primer on wall complete all as specified and directed |
| 34 | Prepration of newsurface of wall and applying two coats of cement based paintwhite or tinted complete all as specified and directed |
| 35 | Taking down 15mm dia GI tubing and connections incl. cleaning for refixing or removal to store complete all as specified and as directed. |
| 36 | Taking down 20mm dia GI tubing and connections incl. cleaning for refixing or removal to store complete all as specified and as directed. |
| 37 | Cutting chases, pining in, making good to facings where required and pointing in CM 1:3 for concealed water tubing and making good, cutting exc 10cm but n.exc 20cm girth in brick walls complete all as specified and directed |
| 38 | S&F of 15 mm bore steeltube, medium grade, galvanised with all fittings such as bends, elbows, tee etc and fixed to walls and ceiling complete all as specified and directed. |
| 39 | S&F of 20 mm bore steeltube, medium grade, galvanised with all fittings such as bends, elbows, tee etc and fixed to walls and ceiling complete all as specified and directed. |
| 40 | M&L in repair PVC floor trap 75mm with gratingincl jointing to waste pipe fixed in cement concrete type B1 ,1:2:4,complete all as specified and directed |
| 41 | M&L in repair PVCfloor trap 100 mm with gratingincl jointing to waste pipe fixed in cement concrete type B1 , 1:2:4 ,complete all as specified and directed |
| 42 | S&F in repairs PVC (SWR) pipes 75 mm dia bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed |
| 43 | S&F in repair75 mm PVC (SWR) bends any radius,complete all as specified and directed |
| 44 | S&F in repair for Vitreous china squatting pan Orissa pattern size 580x440 mm white with P or S trap front or back inlet with integral foot rests (excluding flushing cistern and flush pipe ) complete all as specified and directed |
| 45 | S & F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti syphonage pipe etc complete all as specified and as directed. |
| 46 | S&F in repair vitreous China Urina half Stall type(back or corner wall type) size of 465x355x265mm white,completeincluding providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinalto plugs with and including 60 mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe gratings and urinal for discharge pipe etc complete all as specified and directed |
| 47 | S&F glass self/corner self assembly consisting of 5.5 mm thick glass sheet glass self 12 Cm wide with CP bracket gaurd and railing 60 Cm long complete all as specified and directed |
| 48 | S&F in repairbib tap 15mm dia long body,chromium plated, fancy type complete all as specified and directed |
| 49 | S&F in repairbrass CP tubular towel rail of superior quality 20mm dia 60cm long between flanges fancy type complete all as specified and directed |
| 50 | S&F in repairs PVC connection of 15mm bore,600mm long with brass coupling on both ends of superior quality all as specified. |
| 51 | S&F in repair CP angle valve for 15 mm bore pipe with capstan head long screwed shank including cp cover plate fancy type fixed as in repair. complete all as specified and directed |
| 52 | S&Fin repair 15 mm dia Pillar tapcast copper alloy chromium plated fancy type with capstan head and cup screwed down screwed for G Ipipe or for brass ferrule complete all as specified and directed |
| 53 | M&L for Cement concrete1:4:8 type D2 using 40 mm graded crushed stone aggregate in foundations, filling and mass-concrete complete all as specified and directed |
| 54 | M&L for 18-20mm thick black granite table rubbed and polished as required fixed on pillars over and including15 mm thick rendering in 1:4 complete all as specified and directed |
| 55 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed |
| 56 | M&L for RCC design mix M25 (20mm graded crushed stone aggregate for columns, Pillars, Posts and Struts etc. complete all as specified and directed |
| 57 | M&L for RCC design mix M25 (20mm graded crushed stone aggregate for Footing, Plinth beams base for columns etc.complete all as specified and directed |
| 58 | S&F mild steel TMT bar 10mm and over,cut to legth bent to shape required incl cranking, binding with mild steel wire (aneaiied) not less than 0.9mm etc complete all as specified and directed |
| 59 | S&F mild steel TMT bar 8mm and over,cut to legth bent to shape required incl cranking, binding with mild steel wire (aneaiied) not less than 0.9mm etc as stirrups, spacer and binders etc. complete all as specified and directed |
| 60 | M&L for use & waste for formwork to side of concrete foundations footings etc complete all as specified and directed |
| 61 | M&L for use & waste for formwork to side of pillars,columns etc complete all as specified and directed |
| 62 | Dismantling wrought iron or mild steel work of any description not otherwise providedcomplete all as specified and directed |
| 63 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and properembedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand.complete all as specified and directed |
| 64 | M&L for 100mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base surface finished fair and even complete all as specified and directed |
| 65 | M&L hard core of gauge n exc 63mm, deposited spred and levelled in layers n exc 15 cm thick ,warered and rammed to a true surface.complete all as specified and directed |
| 66 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed |
| 67 | S&F stainless steel letter or figure (not less than 2.5mm thick) (Block, Roman italic or indian) Size 200 mm long x 30mm width or as actual required on site etc including fixing complete all as specified and directedNote:- Comma,stop dash etc will not be paid under this item however the cost of same shall be deemed included in quoted unit rate. |
| 68 | Taking down carefully surface aluminium or copper point wiring (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets etc and making good disturbed surfaces even and smooth using CM 1:3 including white/colour wash to match the existing surface complete. |
| 69 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor with 1.5 sqmm using colour code drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm diaISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes 1.0 mm thick and modular mounting cover plates with frame of approved colour for mounting modular switches, sockets etc as required for the following:-complete all as specified and directed(a)One light point controlled by one switch.complete all as specified and directed |
| 70 | (b)One socket outlet 6 A controlled by one switch on indepdendent board. complete all as specified and directed |
| 71 | (c)One socket outlet 6 A controlled by one switch on the same board with other switches.complete all as specified and directed |
| 72 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm and earth continuity conductor 2.5 sqmm colour coded drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm diaISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.0 mm and modular mounting cover plates with frame of approved colour for mounting modular switches, sockets etc as required for one 16 amp socket outlet point controlled by one switch on independent board. complete all as specified and directed |
| 73 | S&F switch piano flush button single pole one way 6 A complete all as specified and directed |
| 74 | Supply and fix socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified and directed |
| 75 | Supply and fix switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified and directed |
| 76 | S&F in renewal LED surface mounted batten 16 watt, powder coated die cast/ extruded aluminium body (Thickness ≥ 1.20 mm) or CRCA sheet body (Thickness ≥ 0.50 mm) and construction as per IS:10322 with driver (Replaceable) as per the requirement with driver efficiency >85%, System lumen efficacy 120 lm/Watt output, Operating voltage AC 140-270 Volt, 50 Hz, operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED & electrical circuitary) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (TC). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all tests required for LED fixtures as BIS shall be submitted. complete all as specified and directedNote:- Heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C. |
| 77 | S&F in repair LED security light fixture 35 watt powder coated pressure die cast aluminum body with driver Input voltage: 140-270 Volt AC, 50 Hz, operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency > 85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, System lumen efficacy ≥105 <120 lm/Watt output, under voltage and over voltage protection, EMIEMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the requirement, life time (LED & electrical circuitry) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc. as required with Minimum 5 year OEM warranty. LM 79 & LM 80 Test report from NABL lab for all tests required for LED fixtures as per BIS shall be submitted. complete all as specified and directedNote:- Heat sink of aluminum housing should be such that LED junction temperature shall not rise above 90°C. |
| 78 | Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 12 Watt LED lamp B22 CDL complete all as specified and directed |
| 79 | Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm sizecomplete all as specified and directed |
| 80 | Supply and fixMCB DB TPN 4 way 415 Amps rated bus bar 240Volt, Double door type complete all as specified and directed |
| 81 | Supply and fixing MCB TPN 40 To 100 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed. |
| 82 | Supply and fixing MCB SP 6-32Amps240 V, C- curve, 50 Hz, breking capacity-10 kA . complete all as specified and directed |
| 83 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipemedium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed |
| 84 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4.0 core complete all as specified and directed. |
| 85 | Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. orfor shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out any type soil complete all as specified and directed |
| 86 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed |
| 87 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed |
| 88 | Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cablefor under ground cable complete all as specified & directed.(Note\"- Punned down thick of 18cm shall be considerd for mesurement) |
| 89 | Supply & laying sub class \"B\" bricks old size laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified and directedcomplete all as specified |
| 90 | Supply and fixSPN MCB DB 4 wayswith 200 Amps rated bus bar 240Volt, Double door type complete all as specified and directed |
| 91 | Supply and fixing MCB SPN 32 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed |
| 92 | S&F in replacement of LED post top lantern 40 Watts 230 Volt AC Outdoor type with decorative post top for 360 degree indirect light IP 65 Protection with impect and corrosion resistant coplete with driver and lamp complete all as specified and directed |
| 93 | Supply and fixing LED Flood Light 100W fittings well equiped with IP 66 protection or above complete all as specified and directed |
| 94 | S & F PVC/SMC weather proof, hinged door, junction box, size 300mm x 200mm x 100mm with 30A Aluminium bus bar 04 Nos, 240V, Neutral link and 1No MCB SP of 06 Amps, alongwith necessary fixing arrangement such as clamps, nut, bolts, etc complete all as specified and directed |
| 95 | S&F decorative two bracket wall mounted fancy light fitting made up of brassrubi lamp brand duble handed including bulb of 9-12 wattscovered by glass complete all as specified and directed |
| 96 | Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified and directed |