| 1 | JOB No. 3BRD/CAP/05/2025-26 |
| 2 | Demolition of lime concrete / lean concrete /Brick bats etc from sunken slab portion exc. 15 cm thick but above ground floors, complete all as specified and directed by Engineer-in-charge including removal of demolished material from MD land debrish away from site to a disignated point by local administration or a distance up to 1.5 km from site.complete all as specified and directed by Engr-in-Charge. |
| 3 | M & L for 25 mm thick cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregates as in flooring laid in slope complete all as specified and directed by Engineer- in-charge. |
| 4 | M&L lean concrete type E-2 (1:5:10) using 40mm bricks bats aggregate as in sunken portioncomplete all as specified and directed by Engineer-in-charge. |
| 5 | M & L for 40mm GI medium grade Spout pipe for sunken work complete |
| 6 | M&L for providing water proofing tratment of sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound coating of make as approval in Technical Instruction 5/2003 by adding:(a) 15mm thick plaster (1:4) cement sand mortar with integral water proofing compound 2% by weight of cement on floor and wall / beam , finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowedto dry. (Note: Water proofing compound shall be measured and paid separately).(b) First layer of slurry of cement @0.5 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.25 kg/sqm. This layer will be allowed to air cure for 4 hrs.(c) Second layer of slurryof cement @0.25 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.15 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs. complete all as specified and directed by Engineer-in-charge.NOTE : Floor area of the sunken slab shall be measured only.Make of Acrylic based polymer modified cementitious compound : Dr.fixit/Fosroc ( Brushbond) /Sika (Sikatop-100) |
| 7 | Supply only water proofing compound ISI marked complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for Non-skid Ceramic coloured tiles 7 to8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 thick screed bed in CM 1:6 and dismantling of existing tilesremoval of rubbish off the premises debrish away from site to a disignated point by local administration or a distance up to 1.5 km from site complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for , Glazed ceramic coloured tiles in vertical surface 350 x 250 x 7 mm /450 x 350 x 7mm thick as in skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles, 10 mm thick for wall finished in CM 1:4, including dismantaling floor hearth or wall tiling including cement mortar bedding (but not backing) removal of rubbish off the premises debrish away from site to a disignated point by local administration or a distance up to 1.5 km from site complete all as specified and directed by Engr-in-Charge. |
| 10 | S&F in repair 100 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall, laid in trenches or in floors, complete all as specified and directed by Engr-in-Charge. |
| 11 | All as per Srl item No. 10 here-in-before but 75 mm diacomplete all as specified and directed by Engr-in-Charge. |
| 12 | Fixing only in repair 100 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall, laid in trenches or in floors, after necessary cleaning complete all as specified and directed by Engr-in-Charge. |
| 13 | Fixing only in repair 75 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall, laid in trenches or in floors, after necessary cleaning complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F 100 mm cast iron bendscomplete all as specified and directed by Engr-in-Charge. |
| 15 | All as per Srl item No. 14 here-in-before but 75 mm diacomplete all as specified and directed by Engr-in-Charge. |
| 16 | M & L for branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches 100 mm dia complete all as specified and directed by Engr-in-Charge. |
| 17 | M & L for branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallelbranches 75 mm dia complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F cast iron cowls 100 mm dia as in repairs complete all as specified and directed by Engr-in-Charge. |
| 19 | S&F cast iron cowls 75mm dia as in repairs complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F in repairs 75 mm dia cast iron Floor Trap/Nahani Trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4). |
| 21 | S&F in repairs 100 mm dia cast iron Floor Trap/Nahani Trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4). |
| 22 | Fixing only in repair 100 mm cast iron Bends/ Tee/ Cowls after necessary cleaning complete all as specified and directed by Engr-in-Charge. |
| 23 | All as per item No. 22 here-in-before but 75 mm dia after necessary cleaningcomplete all as specified and directed by Engr-in-Charge. |
| 24 | M&L for Cutting holes into or through brick walls built in cement mortar or cement lime mortar having superficial area not exceeding 150 Sqcm each. Making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 complete all as specified and directed by Engr-in-Charge. |
| 25 | Cleaning of tree including cutting of trunk portion protuding over wall surface / roof surface/terrace of building of height up to 10.0 Metre including necessary scaffolding and necessary safety measure if required and making good the surface in cement mortar (1:3) and applying one coat of anti growth of vegitation chemical as directed by Engr-in-Charge and removing of unserviceable material outside MD land and cleaning site complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F in repair PVC (SWR) pipes 110mm dia Single socketed, in any length with rubber ring joints fixed to walls, laid in trenches, floors etc complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F in repair for 110mm PVC (SWR) bends any radius complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F in repair for 75 mm PVC (SWR) pipes single socket in any length with rubber ring joints, laid in trenches, wall, floors or laid in sunken floors, walls etccomplete all as specified and directed. |
| 29 | S&F for 75 mm PVC bends,branch piece or similar fitting as reqd to make the system functionalcomplete all as specified and directed. |
| 30 | S&F for 75 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 31 | Taking up or down GI steel/ Kitek tubing 15 mm with connections or fittings from wall, ceiling, floor etc complete all as specified and directed by Engr-in-Charge. |
| 32 | Taking up or down GI steel/ Kitek tubing 20 mm with connections or fittings from wall, ceiling, floor etc complete all as specified and directed by Engr-in-Charge. |
| 33 | S&FGI water tubes, 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors complete all as specified and directed by Engr-in-Charge. |
| 34 | S&FGI water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors complete all as specified and directed by Engr-in-Charge. |
| 35 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exc 20 cm girth complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F in repair Vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, white colour, with integral foot rests (excluding flushing cistern and flush pipe), including 100mm \"P\" or \"S\" trap set complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern) including connection to drain and flushing pipe antisyphonic pipes etc complete all as specified and directed by Engr-in-Charge. |
| 38 | S&Fin repair PVC syphonic action type flushing cistern 10 litre capacity, low level with inlet, ball valve float and bracket with complete fitting complete all as specified and directed. |
| 39 | S&F15 mm fancy type Stop valves cast copper alloy chromium plated with long shank and Cup ( Concealed Type) screwed down high pressure with crutch both ends for iron pipes or for union and fixed in repair complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F15 mm fancy type anglevalves cast copper alloyscrewed down high pressure with crutch both ends for iron pipes or for union and fixed in repair complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F 15 mmBib taps long body cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore fixed in repair complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F in repairs 15 mm brass chromium plated wall mixer for mixing Hot and Cold water screwed down for iron pipes for complete all as specified and directed. |
| 43 | S&F in repairs 15 mm brass chromium plated centre hole WHB mixer with connection pipe for mixing Hot and Cold water screwed down for iron pipes complete all as specified and directed by Engr-in-Charge. |
| 44 | S&F in repairs for Vitreous China under counter basin wash basin, white or ivory colour flat back, size 470mm x 350mm excluding taps, waste chain and plug and porcelain stopper but including brackets any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe etc fixed complete all as specified and directed. |
| 45 | S&Ffor 5.50mm thick 1400 x 800mm mirror of selected quality glass with eadge moulding, mounted on wall fixed with SS stud fixed complete all as specified and directed. |
| 46 | S&F in repair for sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long, complete all as specified and directed. |
| 47 | S&F PVC connection 15 mm size with PTMT nuts of lengh 450 mm long complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 49 | S&F in repairs Chromium plated shower roses swivel shower brass chromium plated with arm 100 mm size for fixing with 15 mm pipes with swivel joints, any size including fixing to steel pipes or union complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F in repairs for PVC waste pipe 32mm dia, complete with 80 cm long flexible for WHB/Urinals fixed complete all as specified and directed. |
| 51 | Taking down cement plaster of any description on brick or stone walls etc, including raking out joints, hacking for key scrubbing down with water, etc complete all as specified and directed by Engr-in-Charge. |
| 52 | M&L for Rendering 15mm thick in CM 1:4 on brick work, concrete, R.C.C.Surfaces on mumty, parapet or similar surfaces at any height finished even and fair without using extra cement of, up to height 12 metre, incl neccessary scaffolding complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L Rendering 15mm thick on brick surfaces of wallin cement mortar (1:6), finished, even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge |
| 54 | M&L for Rendering 10 mm thick in cement mortar (1:4) on ceiling, parapet, chajjas, facias of building and finished the surface even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge. |
| 55 | M&L preparation of old/new plaster surfaces and applying two coat of oil bound distemper white or tinted over a coat primer complete, all as specified and directed by Engr-in-Charge. |
| 56 | M&L for preparation ofnew plaster/un-treated surface of wall / coloum, beam, chajja etc. andleveling / edgesing the disturbed surface and apply two coat of extrior acrylic emulsion (weather proof treatment) over a coat primer, to be applied using an airless spray machine, complete all as manufacturer\"s instruction and as directed. |
| 57 | M&L for prepration of new surface of ceiling and applying two coat of oil bound distemper white or tinted over a coat of primer complete all as specifeid and directed by Engr-in-Charge. |
| 58 | M&L for Rough cast plaster after applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required)mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered complete all as specified and directed, including taking down cement plaster and racking out joints, hacking for key scrubbing down with water etc, complete all specified and directed by Engr-in-Charge. Note : WPC shall be measured and paid separetely. |
| 59 | Taking down chowkhat or frame n .exc. 1.5 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 60 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification complete all as specified and directed. |
| 61 | S&F Factory made Solid PVC moulded Door Shutter 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face with particle board core, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 62 | Supply and Fix, Aluminium anodised, barrel tower bolts 150 mm long, powder coated, of extruded section and fixed, complete all as specified and directed. |
| 63 | S&F Aluminium handles, cast type, anodised 100mm in size fixed with screws complete all as specified and directed. |
| 64 | Supply and fix, butt hinges, 100mm long, extruded aluminium alloy with galvanised stainless steel hinge pin, complete all as specified and directed. |
| 65 | Taking down shutter of any description not exceeding 1 Sqm each complete all as specified and as directed. |
| 66 | Taking down shutters exe 1 sqm but n exc 2 Sqm each complete all as specified. |
| 67 | S&F for 35mm thick 2nd class hard wood factory made plain, framed paneled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm venerred particle board with commercial veneering on both side faces.The size of rail and site as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated (factory made shutter) complete all as specifed and directed. |
| 68 | S&F for 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified inSSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats. |
| 69 | Supply and Fix Aluminium anodised, barrel tower bolts 200mm long, powder coated, of extruded section and fixed, complete all as specified and directed. |
| 70 | Supply and fix, Aluminium alloy, anodised, Sliding door bolts 200mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed. |
| 71 | Supply and fix 140mm size Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed. |
| 72 | S&F Aluminium handles, cast type, anodised 150 mm in size fixed with screws complete all as specified and directed. |
| 73 | M&L for preparation of new or previously untreated steel surface of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 74 | M&L for preperation of new wooden surfaces or old of any description and appying two coats of Synthetic enamel paint over a coat of pink primer complete all as specified. |
| 75 | Material and labour for hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed. |
| 76 | Supply and fix plain sheet glass 3mm thick, ordinary quality, not exceeding 0.50 Sqm in each pane, and glazing with oil putty and securing pins, spring clips etc, complete all as specified and directed. |
| 77 | S&F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 78 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 79 | M&L for prepration of old surfaceincluding by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots on the wall and applying one coat of oil bound distemper white or tinted over 1mm thick wall care putty, to be applied using an airless spray machine, after covering of window glass, door shutter and electric point/ appliances with help of polythene/news paper complete all as specified and directed by Engr-in-Charge. |
| 80 | M&L for preparation of old plasterd surfaces including by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots on the wall and leveling / edgesing the disturbed surface with water proofing putty and applying two coat of exterior acrylic emulsion weather proof treatment upto 15 Metre height to be applied using an airless spray machine including necessary scaffolding etc complete all as specified and directed. Note : The tint and shade be as approved by the GE. |
| 81 | Material and labour for cement concrete (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregate, as in roof kerb, mud stops, benching, padding on chhajjas including use and waste necessary form work and scaffolding up to 7metre height complete all as specified and directed. |
| 82 | Taking down carefully aluminum/copper point wiring (light, fan, socket any type, power, bell etc. complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fitting etc) and removing the materialfrom site and making good the disturbed surfaces of walls ceiling etc complete all as directed. |
| 83 | M&L for Concealed Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, copper conductor, inuniversal colour code with & including suitable size of rigid non-metallic UPVC conduit (not less then 20mm dia medium grade) and its all accessories complete concealed in wall / roofincl cutting & chases and modular flush metal boxes 0.8 mm thick suitable for modular fittings including modular outer cover plate outer Mirror/glass finish of make Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea)/ Goldmedal (GIFA Z9) with inner frame suitable for cover plate as per site requirementfor mounting modular switches, sockets,etc including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete by making good disturbed surface (i.e plastering, one coat of putti and two coats of interior emulsionpaint with matching existing surface) complete all as specified and directed. |
| 84 | One light point/ exhaust/ ceiling fan/ bell controlled by one way switch 6 Amp complete. |
| 85 | One 3 pin 6 Amps socket point controlled by one switch on same board. |
| 86 | One 3 pin 6 Amps socket point controlled by one Modular switch on independent board. |
| 87 | All as per Srl item No. 83.00 but for 3 pin / 5 pin 16 Amps sockets outlet with 2.5 Sqmm PVC insulated & unsheathed (FRLSH) copper conductor cable independent complete all as specified and as directed. |
| 88 | Supply and Fixing Modular switch 16/20 Amp single pole one way, 2 Module with indicator and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the importent parameters like rating etc should be laser printed on every switch along with catalogue number all as specified.Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea) / Goldmedal (GIFA). |
| 89 | Supply and Fixing Modular socket shutter type, 2-in-1, 3 and 5 pins 6 /16 Amps, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue numbercomplete all as specified. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea) / Goldmedal (GIFA). |
| 90 | Supply and Fixing Modular Ceiling rose surface bakelite, Square in shape 100mm x 100mm three terminals complete all as specified. |
| 91 | Supply and Fixing in replacementModular switch 6 Amps single pole one-way, 1 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue numbercomplete all as specified.Make: Legrand (Arteor) / Schneider (Zencelo) / Anchor(Panasonic Thea)/Goldmedal(GIFA) |
| 92 | Supply and Fixing Modular socket shutter type, 2-in-1, 3 pins 6 Amps, ISI marked, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the importent parameters like rating etc should be laser printed on every switch along with catalogue number complete all as specified. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea) / Goldmedal (GIFA). |
| 93 | Supply and fixing in replacement indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 20 watt LED Tube fitting with aluminium channel housing & integrated electronic driver, energy efficient, 140V-270 volts, Warm/natural/cool as per site requirement type >100 Lm/Wattcomplete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified. |
| 94 | Supply and fix in repair of Exhaust fan 380 mm sweep, copper winding, 2200 CMH, 100 W, 4 blades with aerodynamic design, Mettallic type alongwith GIlouvers complete suitable to work on AC, single phase, 230 Volts, 900 RPM, 50 Hz supply and including cutting of hole in wall of suitable size and connecting up with three core twisted flexible copper conductor cable of suitable size 0.75 Sqmm all as specified and directed. Make : CG/ Havells/ Bajaj/ Usha. |
| 95 | Material and labour for Sub Main Wiring with two run single core 6.0 Sqmm (nominal area) multi stranded copper conductor FRLSH PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100 volts grade colour code cable for earth continuity and making good disturbed surface including taking down old, complete all as specified and directed.Note :- Two run of 6 Sqmm + One run of 6 Sqmm for earth wire + one run of UPVC conduit 25 mm dia shall be measured as one Running metre. |
| 96 | Supply and fixing in replacement of MCB DB Single pole and neutral 08 way, double door, sheet steel phospehtised powder painted (White colour) withIP 43 protection 240 V neutral link, earth bar and Din rail complete all as specified and directed. Make : Legrand/ Havells/ Goldmedal. |
| 97 | Supply and fixing Arc Fault Detection Device (AFDD) with RCBO 32 Amp combined SPN MCB + AFDD + RCCB, offering protections for overload, short circuit, reidual current characteristices type A, over voltage protection above 270V AC +/- 5% & series, parallel arc fault, AFDD must be with dual test button for AFDD and earth leakage functions along with single diagnostic LED with blinking patterns for continious ON series arc parallel arc & over voltage protections. Make : Havells/ Legrand/ ABB. |
| 98 | Supply and fixing in replacement of MCB Single pole 6 to 32 Amp, 240V, 10KA, \"C\" curve with indicator light, integrated label holder complete all as specified & directed. Make : Havells/ Legrand/ Goldmedal. |
| 99 | Supply and fixing water storage heater vertical (geyser) with inner Tank Material : Blue Diamond Glass Lined Tank - 2X Corrosion Resistance, Outer Body Material : ABS, Type : Storage, Capacity : 50 Litres, AC 220-240 Volts, Wattage : 2000 Watts with auto temperature cutoff, Pressure : 8 Bars, BEE Rating : 5 Star complete including SS 304 pipe 600mm connections and saftey valve for geyser all as specified and directed.Make : Racold/ Havells/ Goldmedal/ V Guard/ Jaquar. |
| 100 | JOB No. 3BRD/MW/09/2025-26 |
| 101 | Taking down cement plaster on brick/stone masonry wall incl raking out joints, hacking for key, scrubbing down with water etc. |
| 102 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thick (below or above ground level) and removing the same outside of MoD land upto a distance exc 2.0 Km but n.exc 2.5Km complete all as specified and directed. |
| 103 | Dismantling stone slabs, tilesand paver blocks of any descriptionor thicknessin floors, aprons, riser of steps, skirting, dado etclaid in any mortar complete all as specified. |
| 104 | Dismantling offloor, hearth or wall tiles of any description or thickness laid bedded and pointed in any mortar and removing debries from outside MoD land complete all as specified and directed. |
| 105 | M&L for vitrified tiles light shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqmasin floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement, laid over and including cement screed bed 15mm thick in cement mortar 1:4, complete all as specified. |
| 106 | M & L for Machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick screed bed of CM (1:4)laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 107 | M&L for rendering 15mm thick inCM 1:6 on concrete/block masonary surfaces and finished even and smooth without using extra cement complete all as specified and directed. |
| 108 | M&L for rendering 15mm thick inCM 1:4on concrete/block masonry surfaces and finished fair and even without using extra cement complete all as specified and directed. |
| 109 | M&Lfor preparation of newly plastered wall surfacesand applying two coat of oil bound distemper over one coat ofprimer including leveling the surface which undulation found with cement putty etc complete all as specified and directed. |
| 110 | M&L for preparation on newly plastered external wall surface and applying two coat of weather proof (exterior grade) acrylic emulsion paint with anti fungal property over a coat of primer of the same manufacturer as that of paint complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard). |
| 111 | M & L for brick work subclass \"B\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1: 4, complete all as specified and directed. |
| 112 | M&L Plain cement concrete (PCC) type 1:4:8 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete complete all as specified and directed. |
| 113 | M&L cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in lintle , Shelves upto 1.5m clear span, steps, bed plates, kerb & coping including necessary formwork complete all as specified and directed. |
| 114 | M & L for mild steel bars TMT, 10mm dia and over, cut to length, bent to shape required, including cranking, bending for hooping of columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, as in reinforcement, complete all as specified and directed. |
| 115 | M& L for plain cement concrete type A-1 (1:1.5:3) (Using 20 mm graded crushed stone aggregate) as in hard standing finished with even and smooth with using extra cement including use and waste form work complete all as specified and directed. |
| 116 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A\" complete all as specified and directed. |
| 117 | Note :- Amount of credit ofRs. 13910.00for retrieved materials is mentioned in Schedule of Creditof tender documents in pdf form which will be deducted offline while acceptance of tender. |