| 1 | Note :The unit rate quoted by the tenderer under Col No (13) of Sch `A’ (BOQ) unless specifically mentioned otherwise such as labour only/fixing only,for all items of works shall be deemed to be including cost of all materials, labour, tools and plants, testing and commissioning of work in position complete as required for entire completion of work. |
| 2 | Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radiusbuilt in cement sand mortar 1:4 complete in and including demolition of brickwork or stone boulder masonarybuilt in cement mortar including all quoins, arches, pillars etc for area where servicable bricks retrived and removal of rubbish outside MoD land ,complete all as specified and as directed by Engineer -in-Charge. |
| 3 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement for building upto four storey height,complete all as specified and directed by Engineer-in-Charge. |
| 4 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement for building upto four storey height,complete all as specified and directed by Engineer-in-Charge. |
| 5 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement for building upto 20 metre height in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removal of rubbish outside MoD land ,complete all as specified and directed by Engineer-in-Charge. |
| 6 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement for building upto 12 metre height in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removal of rubbish outside MoD land ,complete all as specified and directed by Engineer-in-Charge. |
| 7 | Preperation of newly plastered surfaces of walls and applying two coats of cement base paint,complete all as specified and directed by Engineer-in-Charge. |
| 8 | Preparation of newplastered or unplastered surfaces of wall and applying three coats of white washing ,complete all as specified and directed by Engineer-in-Charge. |
| 9 | Taking down carefully and refixing steel hanger door shutters (leaf) of size exc. 35sqm but n. exc. 60sqm by mechanical means, keeping aside on the ground, inspecting the parts/ members of doors including carrying out minor repairs/ welding as required, greasing and removing unserviceable members, unserviceable CGI/ PGI sheet, pulley, nut and bolts etc. ,complete all as specified and directed by Engineer-in-Charge.Note:- Supply only of spare parts to replace unserviceable members such as nuts, bolts, washers etc shall be measured and paid separately other spares as required shall deemed to be included in the quoted rate to make the hanger fully functional. |
| 10 | Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete; drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening of Fe-290 (Gde E 165 and fixing in and including dismantling wrought iron or mild steel work of any description and any position not otherwise specifically provided for ,complete all as specified and directed by Engineer-in-Charge.Note:Guide rollers, ball bearing shall be measured as supply only separately and size of gate/ shutter 5 mtr x 8.10mtr. |
| 11 | Easing, adjusting, greasing of base roller & top guide roller andrepair to hanger doors, height not less than 8.0 metre including minor repairs/ welding, change of damaged base roller, guide roller etc. to sliding door leaf of hanger for noiseless and smooth operation,complete all as specified and directed by Engineer-in-Charge.Note: Replaced base roller(s) shall be measured and paid separately. |
| 12 | Easing, adjusting, greasing of base roller & top guide roller andrepair to hanger doors, height exceeding 8 metre upto 20 metre including minor repairs/ welding, change of damaged base roller, guide roller etc. to sliding door leaf of hanger for noiseless and smooth operation ,complete all as specified and directed by Engineer-in-Charge.Note: Replaced base roller(s) shall be measured and paid separately. |
| 13 | MS base roller alongwith 2 Nos ball bearing ¢ral pin on each roller for hanger door and central pin on each roller for hanger door as per the existing shape/ design including welding work as required and necessary greasing/ oiling for smooth functioningfix as in repair ,complete all as specified and directed by Engineer-in-Charge. |
| 14 | MS guide roller fabricated with nuts & bolts alongwith 1 No ball bearing & pin on each roller/ pully to hanger doors shutter leaf as per the existing shape/ design including welding work if required and necessary greasing/ oiling for smooth functioningetc. fix as in repair ,complete all as specified and directed by Engineer-in-Charge. |
| 15 | Mild steel sheeting 0.80mm thick plain, galvanised, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with L-type or J-type or cranked hook as in roofs, walls and match with exiting up to 21 metre heightin and including dismantling of old unservicable steel sheeting/ridge,complete all as specified and directed by Engineer-in- Charge. |
| 16 | Pre-colour coated high tensile strength galvalume plain sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having total coated thickness (TCT) of 0.50mm as per site condition fixed with complete acessories as per manufacturer\"s instructions as profile and shade as approved by GE in roof covering/ cladding to wall ,fixed with self tapping screw upto 21 metre heightin and includingdismantling plain or corrugated steel /fibre sheeting, any gauge, thickness, including Nainital or similar pattern hanger door and making good the disturbed surfaces of wall/other surfaces etc ,complete all as specified and as drected by Engr-in-Charge. |
| 17 | Pre-colour coated high tensile strength galvalume corrugated sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having total coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer\"s instructions as profile and shade as approved by GE in roof covering/ cladding to wall ,fixed with self tapping screw upto 21 metre heightin and includingdismantling plain or corrugated steel /fibre sheeting, any gauge, thickness, including Nainital or similar pattern hanger door and making good the disturbed surfaces of wall/other surfaces etc ,complete all as specified and as drected by Engr-in-Charge. |
| 18 | Fibre glass reinforced translucent (Plycorbonate) Corrugated sheeting of 2 mm thick with side lap fixed with coach screw and washer as in windows ,in roof, wall etc. fixed with self tapping screws, L-type or J-type or cranked hook bolts in lieu of screws, in roofs, walls etcupto 26.5 metre height in and including demolition of old unservicable sheet/ridge ,complete all as specified and directed by Engineer-in- Charge. |
| 19 | PUF (Poly Urethane Foam) insulation of 50mm thick minimum density 40Kg/ Cum filled in between two pre-painted galvalume aluminum zinc coating GI basedtop side corrugated and other side plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to walls at any position and any height, fixed with self tapping screws, including taking down old panels of any description or any size upto and including 25.6 metre height ,complete all as specified and directed by Engineer-in- Charge. Notes:- (i) Rate of necessary scaffolding or crane shall be included. (ii) Colour and size of PUF panel shall be approved by GE. |
| 20 | Roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. ( Fe-410,Gde-E-250)quality -A, fixed by means of welding with existing or other members to received theetc.in and including dismantling wrought iron or mild steel work of any description and any position not otherwise specifically provided for upto and including 21 metre height ,complete all as specified and directed by Engineer-in- Charge. |
| 21 | Preparation of new or previously untreated steel surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint over one coat of red oxide primer,complete all as specified and directed by the Engineer in Charge. |
| 22 | Taking down carefully aluminium door/ windows chowkhats or frames exc. 1.5 sqm but not exc. 4 Sqm each without taking off shutters from frameand refixing the same after inspecting the parts/ members of doors, including minor repairs as required and removing unserviceable members and replace as new ones as required ,complete all as specified and directed by the Engineer in Charge. Note:- Replacement of aluminium section, glass andrubber packing shall be measured and paid separately. |
| 23 | Taking down carefully aluminium shutters of any description exceeding 1.00sqm and not exceeding 2.0sqm and refixing the same after inspecting the parts/ members of doors, including minor repairs as required and removing unserviceable members and replace as new ones as required ,complete all as specified and directed by the Engineer in Charge.Note:- Replacement of aluminium section, glass andrubber packing shall be measured and paid separately. |
| 24 | Sheet glass 5.5 mm thick, selected quality in squares not exceeding 0.5 Sq. min each pane including rubber packing, glazing strips in aluminium frame for ddor/ windows at any position and any height etc in andincluding Hacking out old broken glass panes of any thickness, size ,quality or description from wooden frames , glazed with putty or fixed with beads ,complete all as specified and directed by Engineer-in- Charge. |
| 25 | Aluminium powder coating (miniumum thickness of powder coating is 50 micron)work for shutters of doors, windows, ventilators, and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with equired EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and all asdirected by Engineer -in-charge. |
| 26 | Stainless steel butt hinges 100mm size fix as in repair,complete all as specified and directed by the Engineer in Charge. |
| 27 | Aluminum door handles 150mm cast type anodised round type/ curved \"D\" type fix as in repair,complete all as specified and directed by the Engineer in Charge. |
| 28 | 75mm long, 04 lever (brass) vertical type mortice lock suitable for aluminum door fix as in repair,complete all as specified and directed by the Engineer in Charge. |
| 29 | 100mm long 04 lever (brass) vertical type mortice lock suitable for aluminum door fix as in repair,complete all as specified and directed by the Engineer in Charge. |
| 30 | Aluminium body (Die cast body)Door closer hydraulically regulated, designation No. 3 , universal type , suitable for door shutters 851 to 1000 mm in width and ofweight between 61 to 80 kg and fix as in repair , complete all as specified and directed by Engineer -in-charge. |
| 31 | Double action floor door spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet, foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty and fix as in repair, complete all as specified and directed by the Engineer in Charge. |
| 32 | Taking down rolling shutter of any description, size not exceeding 20 Sqm each and removal from site to store , complete all as specified and directed by the Engineer in Charge. |
| 33 | Steel rolling shutters having 1.25 mm thickness of lath , without ball bearing, as specified including top hood cover, 50mm anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, push, pull or manual type ,complete all as specified and directed by Engineer-in-Charge. |
| 34 | Taking down rolling shutter push, pull or manual type,size exceeding 10 Sqm but not exceeding20Sqm and refixing to its original position after cleaning all parts, straighting sliding rails, replacing damaged strips, bottom rails, helical spring and anchoring rod as required, greasing/oiling, servicing for smooth functioning for all parts, including welding etc,complete all as specified and directed by Engineer-in-Charge.Note:- Replaced parts shall be measured and paid fror supply only under respective items separately. |
| 35 | Taking down rolling shutter gear operated type with bevel gear box ,size exceeding 10 Sqm but not exceeding20Sqm and refixing to its original position after cleaning all parts, straighting sliding rails, replacing damaged strips, bottom rails, helical spring and anchoring rod as required, greasing/oiling, servicing for smooth functioning for all parts, including welding etc,complete all as specified and directed by Engineer-in-Charge.Note:- Replaced parts shall be measured and paid fror supply only under respective items separately. |
| 36 | Supply only steel sheet 75mm wide lath strip 1.00mm thick for rolling shutters including mild steel clips at either ends duly painted with two coats of synthetic enamel paint(shade to match with the existing) over a shop coat of red oxide primer,complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply only mild steel spring 75mm to 150mm dia, made of high tension steel wire conforming to IS: 4454 having 60 to 80helical for smooth working condition for rolling shutters,complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply only Mild steel anchorig rod 50mm dia including necessary fixture for rolling shutters , complete all as specified and directed by Engineer-in-Charge. |
| 39 | Anti-bird net machine made of 22mm x 22mm square size black/ blue colour made of high density polythene UV stabilized wire of size 720/2x3 (1.00mm) dia with twine breaking strength 22.00 kg, knot breaking strength 28.00 kg and mesh breaking strength 18 kg, 380 Den/ 15ply including 4.00mm dia border rope of high density UV stabilized rope monofilament and fixed to wall including \"T\" type nuts & bolts with 5.00 to 10.00mm dia washers in and including taking down old anti bird net at approximate height of 16.00mtr & above of hanger, including all necessary scaffolding, ladder , complete all as specified and directed by Engineer-in-Charge.Notes: -(i) 4 Samples of make shall be approved by GE in writing after checking above parameters from manufacturers test certificate.(ii) Contractor shall submit five years life guarantee for bird proof net on bond paper.Contractor shall also submit security dep[osit(In addition to performance security) amount i.e. 5% of executed in the form of FDR or same shall be retain from FB(iii) This item shall be executed for the building upto 16 metre height fronnm ground level and quoted rates shall be deemed to include for execution of this item upto 16 metre height.(iv) All safety measures for the safety of workmen shall be ensured by the contractor. (v) Insurance of workers shall also be got done by the contractor before execution of this item. This aspect shall be deemed to be included in quoted rates.Make:- GARFIL/ TUF ROPES/ SS ROPES/ BIRDNET. |
| 40 | Taking down old anti bird net at approximate height of 16.00mtr and above of hanger, including all necessary scaffolding, ladders etc, and refixing it in original position after necessary stitching or jointing with old or new anti bird net , complete all as specified and directed by Engineer-in-Charge. |
| 41 | PVC sheet fillet 5mm thick of width 35 mm for wall paneling inclusive of fixing on wall to make PVC frame as per specification and drawing(Page No-180 of SSR Part-II)in and including taking down old unservicable sheet including cleanign and making good the disturbed surfaces of wall/other surfaces etc, complete all as specified and as didrected by Engr-in-Charge. |
| 42 | PVC wall lining consisting of 5 mm thick solid/Hollow printed colour PVC sheet inclusive of solvent cement complete all as specified and drawing (Page No-180 of SSR Part-II) in and including taking down old unservicable sheet including cleanign and making good the disturbed surfaces of wall/other surfaces etc ,complete all as specified and as didrected by Engr-in-Charge. |
| 43 | False ceiling upto height of 5.00 metre of size 600mm x 600mm x 16mm mineral fiber ceiling tiles of type classic lite RH-99 fine texture of Armstrong/ E-board 6mm thick or equivalent in \"Saint Gobain\" laid on exposed grid systems. The frame work comprising of main runner spaced at 1200mm maximum (centre to centre), hangers (GI wire 4.0mm dia) to be fixed by approved roof plug level adjusters and screws etc. The last hanger at the end of each main runner should not greater than 450mm from the adjacent wall, flushing fitting 1200mm long cross trees (with double stitching) to be interlocked between main runner at 600mm shall be \"T\" shape section with single rotary stitching made of GS sheet and of size 15mm x 32mm and 3000mm long, cross runner shall be \"T\" shaped with double rotary stitching made of GS sheet and of size of 19mm x 19mm and 3000mm long, colour white, centre to from 1200mm x 600mm modules, cut cross tees longer than 600mm to be supported independently, 600mm x 600mm modules to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees. perimeter trim to be wall angle secured to wall at 450mm maximum (centre to centre) including PVC clips to hold the ceiling tiles in and including taking down old unservicable false sheeting including cleanign and making good the disturbed surfaces of wall/other surfaces etc ,complete all as specified and directed by Engineer-in- Charge. |
| 44 | Preparation of concrete surfaces to make it free from contamination such as mortar, paint splashes, oil, grease etc. including removal of excessive laitance by light mechanical grinding followed by vacuum cleaning and carrying out the following treatment/ operations ,complete all as specified and directed by Engineer-in- Charge :-(a) Applying one coat of Bostik Prime coat or equivalent in performance in makes specified in Appendix ‘B’ of Particular Specifications.(b) Applying a coat of 2mm thick Bostik Epoxy Underlay Screed EUL 2000 or equivalent in performance in makes as specified in Appendix ‘B’ of Particular Specifications.(c) Applying one coat of 1mm thick Epoxy Self Leveling Bostik Utralevel ESL 1000 or equivalent in performance in makes as specified in Appendix ‘B’ of Particular Specifications.(d) Apply spike roller to get a uniform finish and allowed to dry. |
| 45 | JOINT FILLING :-PU flooring joint filling , joint surface must be dry, free from dust, coaling bituminous mastics, concrete during agencies mould release agents, oil, grease and loose particles. All joints shall be throughly cleaned out by hot compressed air and sanding with emery paper or other approved means and shall be approved by Engr-in-Charge before they sealed. Before the sealing insert a bond breakeer ( back up rod) shall be 20to 25% more than the jointso that there is no seepage of sealant through joints edges.The cleaned and prepared joints shall be primed with Bostic N49 primer on the sides of the vertical face of the concrete joints in order to improve the adhesion of the polyurethene sealent as specified by the manufacturer .Fix masking tap to prevent edges of joints becoming dirty due to spillage of polyurethane sealent at the time of pouring.The Part -A and Part-B of the polyurethane sealentBostic seal N Flex 2k must be mixed thoughly for three minutes with slow speed stirrer until the material is completely mixed. The mixed sealent may be loaded into an approprite sealent gun and apply to the Sealing slot so that the finished level of the seal is recessed below the trafficked surface all as specified by the manufacturer ,complete all as specified and directed by Engineer-in- Charge . |
| 46 | Sheet glass 4 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane including fixing with glass pins to hold glass in position in andincluding Hacking out old broken glass panes of any thickness, size ,quality or description from wooden frames/steel frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads ,complete all as specified and directed by Engineer-in- Charge.Note:- No extra payment for replacment of damaged woodenbeads required for glazing glass in wooden window. |
| 47 | Fibre glass reinforced translucent (Plycorbonate) plain sheeting of 2 mm thick fixing in windows/ ventilators not exceeding 0.50 Sqm in each pane including fixing pins and other arrangements to hold sheet in position in andincluding Hacking out old broken glass panes of any thickness, size ,quality or description from wooden frames/steel frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads upto and including 21 metre height ,complete all as specified and directed by Engineer-in- Charge. |
| 48 | Preparation of new or previously untreated steel surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint over prevously primed surfaces,complete all as specified and directed by the Engineer in Charge. |
| 49 | Preparation of old painted steel or Iron surfacesover 10cm width or grith not otherwise described and applying one coat synthetic enamel paint ,complete all as specified and directed by Engineer-in-Charge. |
| 50 | Notes for items where works are required to be executed at Height more than one Storey Height :. (i) Contractor shall hire/arrangethe Big size doublescaffoldinghydra machine with working plateform for fabrication /fixing of hanger door and other allied itemsfrom height more than one storey upto 26.5 metre height . (ii) All safety measures for the safety of workmen shall be ensured by the contractor. Contractor shall arrange/provide the safety life jackets for all concerned Trademen, labour and supervisor deployed at site. (iii) Insurance of workers shall also be got done by the contractor before execution of these items. (iv) Contractor shall also provide at site the necessary precautionary sign boards and Flags.(v) All arrangements shall be made to comply the rules/regulations of the airfield authorities.(vi) The quoted rates of all items shall deemed to be included for above provisions and noting extra shall be admissible on this account. |
| 51 | Note :Schedule of creditto be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse. |