| 1 | M/L maintenance and servicing of DG Set of any capacity complete by replacing the fuel filter, lubricating oil filter, replacement of air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolantlevel etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories asprescribed by the manufacturer and test for satisfactory running of DG set for two hour minimum at connected load and record shall be made in respect of RPM , oil pressure, oil temprature, coolant temprature, voltage, frequancy, load current, battery charging, fuel consumption & noise leveletc complete all as specidied and directed. Note :-1. Minor spare parts i.e. nut bolt, washer, petroleum jelly deemed to be included in the quoted unit rate of this item. 2. Major spare parts/Oil/Coolant etc will be measured and paid Seprately under respective of schedule \"A\". 3.DHPP will be issued by dept for testing only. |
| 2 | 160 to 320 KVA Capacity |
| 3 | 100 to 125 KVA Capacity |
| 4 | 50 to 75 KVA Capacity (Note : For serial item no 1.01 to 1.03Spares parts required shall be measured and paid separately under respective itms of Schedule as supply only.) |
| 5 | Supply only of following items for DG Sets Capacity of 160 KVA to 320 KVA (Required under Sl item No. 1.02above) :- |
| 6 | Air Filter |
| 7 | Fuel Filter |
| 8 | Lubricating oil filter |
| 9 | Supply only of following items for DG Sets Capacity of100 ot 125 KVA (Required under Sl item No. 1.03above):- |
| 10 | Air Filter |
| 11 | Fuel Filter |
| 12 | Lubricating oil filter |
| 13 | Supply only of following items for DG Sets Capacity of50 to 75 KVA (Required under Sl item No. 1.04above):- |
| 14 | Air Filter |
| 15 | Fuel Filter |
| 16 | Lubricating oil filter |
| 17 | Supply & fixedin repair of Hose pipe set & Clips of water / coolentcooled radiator systemfor following capacities of DG set :- |
| 18 | 50KVA to 75 KVA DG set |
| 19 | 100 KVA to 125 KVA to DG set |
| 20 | 160 KVA to 320 KVA DG set |
| 21 | Supply and fixingof following items for DG Sets Capacity of 160 KVA to 320 KVA |
| 22 | Diesel return pipe |
| 23 | Ignition switch for starting DG set with key. |
| 24 | Diesel Fuel Hose pipe from diesel tank to fuel filter |
| 25 | Fuel injector pipe from fuel pump to Injector |
| 26 | Supply and fixingof following items for DG Sets Capacity of 100 KVA to 125 KVA |
| 27 | Diesel return pipe |
| 28 | Ignition switch for starting DG set with key. |
| 29 | Diesel Fuel Hose pipe from diesel tank to fuel filter |
| 30 | Fuel injector pipe from fuel pump to Injector |
| 31 | Supply and fixingof following items for DG Sets Capacity of 50 KVA to 75 KVA |
| 32 | Diesel return pipe |
| 33 | Ignition switch for starting DG set with key. |
| 34 | Diesel Fuel Hose pipe from diesel tank to fuel filter |
| 35 | Fuel injector pipe from fuel pump to Injector |
| 36 | Disconnection and dismantling the fuel injector pump assembly from its original position, repairing & servicingby cleaning / oiling / servicing of fuel injector pump assembly , removing and replacement fuel injector pump repair kit & fuel pipeincluding calibration complete& refixing the same complete all as specified and directed for following capacities of DG set :- |
| 37 | 160 KVA to 320 KVA DG Set |
| 38 | 100 to 125 KVA KVA Capacity |
| 39 | 50 to 75 KVACapacity |
| 40 | Dismantling and taking down radiator assy from engine of any capacity of repairs etc transporting of the radiator of capacity upto 320 KVA for repair/maintenance of rediator fins with the help of cleaning coil solution and cleaning to the radiator complete and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, repair to the leakage places by means of gas welding and including initial filling up coolant and re fixing after repairs including replacement of worn out nut bolts washers etc and testing complete all as specified and directed |
| 41 | Dismantling the water pump for the DG Set taking out the worn out parts, refixing the water pump after replacing water pump kit set for following capacities of DG set:- |
| 42 | 50 KVA to 75 KVA DG set. |
| 43 | 100 KVA to 125KVA DG set. |
| 44 | 160 KVA to 320KVA DG set. |
| 45 | S&F in repairof RPM meter of upto 320 KVA DG set complete all as specified and directed. |
| 46 | S&F in repair of oil pressure Gaugeof upto 320 KVA DG setcomplete all as specified and directed. |
| 47 | S&F in repair of oil temperatureGauge of upto 320 KVA DG set complete all as specified and directed. |
| 48 | S&F in repair of water temperatureGaugeof upto 320 KVA DG setcomplete all as specified and directed. |
| 49 | Taking out following defective parts from Alternator ofDG sets and supply and fixing new parts including testing of DG set complete all as directed :- |
| 50 | AVR unit complete suitable for 50 KVA to 75 KVA DG Set |
| 51 | AVR unit complete suitable for 100 KVA to 125 KVA DG Set |
| 52 | AVR unit complete suitable for 160 KVA to 320 KVA DG Set |
| 53 | Disconnection and taking out the turbo charger assembly complete from the Engine ofany make of 100 KVA to125 KVA DG Set and taking to workshop, strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory workingcomplete all as specified and directed. |
| 54 | M&L for replacement of fiexible coupling including coupling nuts, bolts & washers etc and proper alignment complete all as specified and directed at site suitable for DG sets of capacity :- |
| 55 | 160 to 320 KVA Capacity |
| 56 | 100 to 125 KVA Capacity |
| 57 | 50 to 75 KVACapacity |
| 58 | M&L repair/overhauling of self starter 12/24 Volt of any make/Capacity including replacement of minor items such as carbon brushes, nuts blts etc, complete all as specified directed for fully functional of self starter complete. (Note: All additional spares parts as required will be measured and paid separately as supply only) |
| 59 | Supply only spares parts suitable for self starter 12/24 V as mentioned below:- |
| 60 | Field coil |
| 61 | Armature |
| 62 | Clutch assembly |
| 63 | Supply & fix in repairof self starter assembly 24 voltcomplete for 100 KVA to 125 KVA DG set complete |
| 64 | Supply & fix in repairof self starter assembly 12 voltcomplete for 50 KVA to 75 KVA DG set complete |
| 65 | M&L cleaning oil fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings of suitable quantity of OEM recommendation complete all as specified and directed. |
| 66 | S&F in replacement of Battery 12V 140AHcomplete all as specified and directed. |
| 67 | S&F in replacement of Battery 12V 120AHcomplete all as specified and directed. |
| 68 | S&F in replacement of Battery 12V 60AH complete all as specified and directed. |
| 69 | M&L battery lead copper conductor 25 Sqmm multi stranded PVC insulated with suitable terminals at both ends as per site requirement complete all as specified and directed. |
| 70 | Supply and replaced \"V belt\" as per sample for DG sets of capacitycomplete all as specified and directed |
| 71 | 50 to 75 KVACapacity |
| 72 | 100 to 125 KVA Capacity |
| 73 | 160 to 320 KVA Capacity |
| 74 | Dismantling of alternator assembly of DG Setof capacityupto 125 KVA and taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed. |
| 75 | Dismantling of alternator assembly of DG Setof capacityexc 125 KVA but upto 320 KVAand taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed. |
| 76 | Draining out the old u/s oil from the engine of DG set of any capacity cleaning the oil chamber and supply and filling new lubricant GENSET OIL complete all as directed and specified. (Note: Lubricant oil shall be procured from approved make and in sealed container) |
| 77 | Supply and replacement coolant of approved make suitable for DG sets complete all as directed and specified. (Note: Lubricant oil shall be procured from approved make and in sealed container) |
| 78 | M & L for for repair ofDG Control Panel of any description and in any position of capacity DG Set upto 200 KVAincluding checking AC/DC circuits, tightning of all power / control wiring connectionand replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cablesuitable upto 1100 volts confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to makefunctional including testing complete all as specified . |
| 79 | Material and labour for plate earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead 32mm x 6mm strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all surrounded by adequete quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, earth strip encased in 40 mm bore GI medium grade pipe, including providing watering pipe 20 mm bore GI pipe medium grade from bottom of the earth pit to the top of the electrode complete with earth pit in PCC 1:2:4 type B - O using 12 mm graded crushed stone aggregate, earth work and RCC cover Complete all as specified and shown in electrical plate number 3 of SSR part -1, incl dismantlimg of existing earth pit complete all as specified and directed. (Note: GI earth strip upto 7.5 RM from the test point shall be deemed included in quoted unit rate.) |
| 80 | M&L maintenance/repair at LT Control panel including cleaning in side the panel, tightening of all connection complete installed at pump house for centrifugal pump set/ borewell at different places in the area and replacement of spare parts as required during maintenance. (Note: Spare part will be measured and paid seperately under relevent item as supply only) complete upto 75 HP motor pump set (once in a month) with FASD starter and MCCB. |
| 81 | Material and labour for removing old paint by paint removers or burning offby blow lamps and cleaning with scrapers, any number of coats, any width or girth from the existing suction/ delivery pipe line including headers of any size and applying of painting to existing surcface by using spray gunwith one coat of red oxide and two coat of synthetic enamel paints on existing suction/ delivery pipe lines, including Headers of any size using Blue/Red/Black colour as per site requirement complete all as specified and as directed. |
| 82 | S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 350 Amp with breaking capacity 36 KA complete all as specified and directed |
| 83 | S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 250 Amp with breaking capacity 36 KA.complete all as specified and directed |
| 84 | S&F in replacement moulded case circuit breakers 3 Pole 415 Volt adjustable type 200 Amp with breaking capacity 36 KA. complete all as specified and directed |
| 85 | S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 160 Amp with breaking capacity 36 KA. complete all as specified and directed |
| 86 | S&F in replacement moulded case circuit breakers 3 pole 125 Amps having breaking capcity16 KA at 415 volts. complete all as specified and directed |
| 87 | Supply & Fixing in replacement MCCB 100 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed. |
| 88 | Supply & Fixing in replacement MCCB 63 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed. |
| 89 | S&F in replacement offload changeover switch 4 pole 100 Amps in sheet enclosure compete all as specified and directed |
| 90 | S&F in replacement offload changeover switch 4 pole 250 Amps in sheet enclosure compete all as specified and directed |
| 91 | S&F in replacement offload changeover switch 4 pole 320 Amps sheet enclosure compete all as specified and directed |
| 92 | S&F in replacement offload changeover switch 4 pole 400 Amps sheet enclosure compete all as specified and directed |
| 93 | S&F in replacement 3 pole power contactor ML-3, 28-42 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed |
| 94 | S&F in replacement 3 pole power contactor ML-02, 20-32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed |
| 95 | S&F in replacement 3 pole power contactor ML-1.5, 25 Ampssuitable for fixing in existing panel complete all as specified and directed |
| 96 | S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD complete all as specified and directed |
| 97 | S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-2 FASD complete all as specified and directed |
| 98 | Supply and fixingin replacement of fully automatic star delta starter type ML-3 complete all as specified and directed |
| 99 | M&L in replacement of single phase preventor type VSP-II complete all as specified and directed |
| 100 | S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Analog Type complete all as specified and directed |
| 101 | S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mmAnalog Type complete all as specified and directed |
| 102 | S & F in replacement of Voltmeter selector switch 3 pole 415 Volts, Complete all as specified and directed |
| 103 | S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Digital Type complete all as specified and directed |
| 104 | S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mmDigital Type complete all as specified and directed |
| 105 | S & F in replacement of single phase indicator lamp LED type assembly as per site requirement complete. |
| 106 | M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 1.5 Sq mm complete all as specified and directed |
| 107 | M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 2.5 Sq mm complete all as specified and directed |
| 108 | S&F in replacement of thermal over load relay typeML-1.5 relay range 10-16 Amps complete all as specified and directed |
| 109 | S&F in replacement of thermal over load relay typeML-2 relay range 20-32 Amps complete all as specified and directed |
| 110 | Material and labour for painting to existing surcface of NRV,sluice valves/Strainers valves of capacity 80 mm to 150 mm by using spray gunwith one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below complete all as specified and directed. (Note: color shades are as under:-NRV colour - Black, Sluice Valve colour - Black) |
| 111 | Supply, Installation, commissioning and testing of Retrofitting of emission contro device/Equipements omn DG Set of 200 KVA of any make alternator having a minimum specified particulate matter capturing efficiency of at least of 75% in 5 mode D2 cycle, reduction efficiency of CO, HC and PM 2.5 & 10.Notes :- (i) System to be robust enough for cold start and startup oil emission such that there is no impecton overall maintenance cycle timelines. (ii) Operating back pressure limit to be < 3.3 KPa at Rated Load. (iii) Maintenace cycle to be 5-6 months or 500 Hrs whichever is earlier. (iv) Noise levels to be within CPCB guidelines without silencer. (v) Passive regeneration to be achieved with max 10% duty cycle above 25% load. (vi) Overall power consumption to be lower than 1% of DG Rated Power. (vii) The Emission control device /Equipement must be tested over an ISO -8178 5 mode D2 Cycle for equivelent KVA rating at any of the CPCB coliance Govt approved laboratories . |
| 112 | Supply, Installation, commissioning and testing of Retrofitting of emission contro device/Equipements omn DG Set of 380 KVA of any make alternator having a minimum specified particulate matter capturing efficiency of at least of 75% in 5 mode D2 cycle, reduction efficiency of CO, HC and PM 2.5 & 10.Notes :- (i) System to be robust enough for cold start and startup oil emission such that there is no impecton overall maintenance cycle timelines. (ii) Operating back pressure limit to be < 3.3 KPa at Rated Load. (iii) Maintenace cycle to be 5-6 months or 500 Hrs whichever is earlier. (iv) Noise levels to be within CPCB guidelines without silencer. (v) Passive regeneration to be achieved with max 10% duty cycle above 25% load. (vi) Overall power consumption to be lower than 1% of DG Rated Power. (vii) The Emission control device /Equipement must be tested over an ISO -8178 5 mode D2 Cycle for equivelent KVA rating at any of the CPCB coliance Govt approved laboratories . |
| 113 | Supply,Installation testing and commissioning in replacement of Factory made LT panel board outdoor type, dust & Vermin proof fabricated out of 3.15 mm thick CRCA sheet fixed with Angle iron frame of size 40x40x5mm duly powder coated complete using lugs,and glands of cable connection and having epoxy coated aluminium bus bar 04 wire system of 300 Amp capacity mounted on epoxy insulators, prewired with suitable size of PVC insulated multi strand copper conductor cable having independent enclosure for incoming and outgoing electrical connection and cable gland at bottom for incoming and outgoing and locking arrangement on front side including providing danger notice plate marked skull & boons by higlighting paint and dismantling & taking out old U/S existing LT panel of any description deposited to MES Store Yard including following fittings and fixtures as mentioned below:-INCOMING:-(a)MCCB 400 Amp, Four pole, 415 Volts, 50 HZ 36 KA -01 No. (b)LED indicating lamps for main supply indicating R, Y, B - 01 Set.(c)Voltmeter 0-500 volts digital type with selector switch -01 No.(d)Current transformer having ratio 300/5, 15 VA - 01 Set. (e)Ammeter 0 to 300 amps digital type with selector switch - 01 No. OUTGOING :- (a) MCCB 160 Amp, Four pole, 415 Volts, 50 HZ 16 KA - 04 No(c) Soft startersuitable for 40 HP Centrifugal Pump Set 75A208 to 690V including cooling arrangement for soft starter complete - 03 Nos(e) Digital Ampere meter 0-50 Amp with selector switch 3 PhasesuitableCT ratio 50/5- 14 No..(f) Timer switch series FM /1 quardz, type -QT (Daily) supply -240 Volt AC 50/60 Hz - 12 No |
| 114 | Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front side415 Volts, 3 phase, 50 Hz having copper bus bar of capacity 630 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit currentwith stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc.The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated and suitable to accommodate and supply and fixing ofthe following complete all as specified and directed :Incoming :-(a)MCCB 400 Amp, 4 pole, 415 Volts, 50 HZ 36 KA -01 Nos.(b) Changeover Switches 4 pole 415 volts 400 Amps - 01 No Outgoing :-(a) MCCB 100 Amp, Three pole, 415 Volts, 50 HZ 25 KA -03 Nos.(b) MCCB 160 Amp, Three pole, 415 Volts, 50 HZ 25 KA -01 Nos.(c) MCCB 63 Amp, 4 pole, 415 Volts, 50 HZ 16 KA -01 Nos.(d) Soft startersuitable for 40 HP Centrifugal Pump Set 75A208 to 690V including cooling arrangement for soft starter complete - 03 Nos.(e) Soft starterSuitable for 75 HP Centrifugal Pump 140A208 to 690Vincluding cooling arrangement for soft starter complete- 01 No.(d) Digital Voltmeter 96x96 Sqmm 0-500 Volts with selector switch - 05 Nos(e) Digital Ampere meter 0-200 Amp 3 Phase, 96x96 Sqmm with CT ratio 200/5 - 05 Nos (f)Indicator lamp LED type of(R,Y,B) set of 12 No |
| 115 | Design, fabricate, supply, install, test and commissioning of factory made wall mountedsheet metal enclosure alongwith MCCB 400 Amps 4 pole 415 Volts Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front . |
| 116 | Supply,Installation testing and commissioning in replacement of Factory made LT panel board outdoor type, dust & Vermin proof fabricated out of 3.15 mm thick CRCA sheet fixed with Angle iron frame of size 40x40x5mm duly powder coated complete using lugs,and glands of cable connection and having epoxy coated aluminium bus bar 04 wire system of 300 Amp capacity mounted on epoxy insulators, prewired with suitable size of PVC insulated multi strand copper conductor cable having independent enclosure for incoming and outgoing electrical connection and cable gland at bottom for incoming and outgoing and locking arrangement on front side including providing danger notice plate marked skull & boons by higlighting paint and dismantling & taking out old U/S existing LT panel of any description deposited to MES Store Yard including following fittings and fixtures as mentioned below:- INCOMING:-(a)MCCB 630 Amp, Four pole, 415 Volts, 50 HZ 36 KA -01 No. (b)LED indicating lamps for main supply indicating R, Y, B - 01 Set.(c)Voltmeter 0-500 volts digital type with selector switch -01 No.(d)Current transformer having ratio 300/5, 15 VA - 01 Set. (e)Ammeter 0 to 300 amps digital type with selector switch - 01 No. (f) Off load Changeover 630 Amps 4 pole-01 OUTGOING :-(a) MCCB 160 Amp, Four pole, 415 Volts, 50 HZ 16 KA - 02 No |
| 117 | An amount of Rs 1,01,517.00 shall be deducted from BOQ on account of schedule of credit |