| 1 | Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | M&L for 75mm thick PCC (1:3:6) type C-2 (using 40 mm graded crushed stone agg) in plinth protection path/hardstanding/drain bed/ jhura bed finished cement concrete surfaces fair and even including forming construction joint filled with CM (1:6) complete all as specified and as directed. |
| 3 | Demolition of Stone slabs and tiles of any description or thickness laid dry or dry and pointed in floors, aprons etc complete all as specified and as directed. |
| 4 | M&L for Lacquer coated coloured chequered cement concrete tiles 300 x 300mm x 25mm thick set, jointed and pointed in neat slurry in floors and steps with grey cement and pigments over and incl 15mm thick screed bed or bedding layer of motar for laying floor finishes in cement plaster (1:4) complete all as specified and as directed. |
| 5 | M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and as directed. |
| 6 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 7 | Taking down cement plaster on brick or stone walls or concrete surface, includingracking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick in CM (1:4) on stone masonry, finished even & fair without using extra cement complete all as specified and as directed. |
| 9 | Dismantling old PGI/CGI sheeting of any gaugethickness, including Nainital. Sikkim or similar pattern roof/facia etc complete all as specified and as directed. |
| 10 | S&F of 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in roof coveringfixed with self tapping screws as in roofcomplete all as specified and as directed. |
| 11 | S&F of 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley, eaves, etc fixed with self tapping screwscomplete all as specified and as directed. |
| 12 | S&F in repairs of Hollow Rolled sections as in main and cross beams, hip and jack rafters; purlins where connectedto common rafters and running rails and guides for sliding doors; fixedwithangle cleats or other connecting plates confirming to Fe-290 (Gde E165)complete all as specified and as directed. |
| 13 | Demolition of concrete of any description and in any position not otherwise specially provided for complete all as specified and as directed. |
| 14 | M&L for PCC (1:3:6), type C-2 (using 20mm graded crushed stone agreegate) as in retaining walls etccomplete all as specified and as directed. |
| 15 | M&L for PCC(1:3:6),type C-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 16 | M&L for PCC(1:3:6),type C-1 (using 20mm graded crushed stone aggregate) as in copingcomplete all as specified and as directed. |
| 17 | Use & waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better in rough finished surfaces complete all as specified and as directed. |
| 18 | M&L for Mild steel TMT bars 10mmdia and over cut to length,bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than0.9 mm dia or securing with clips.complete all as specified and as directed. |
| 19 | M&L for Mild steel TMT bars6mm to 8mmdia and over cut to length,bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than0.9 mm dia or securing with clips complete all as specified and as directed. |
| 20 | M&L for RCC (nominal mix) type B1 (1:2:4) using 20 mm graded stone aggregate as in RCC bandcomplete all as specified and as directed. |
| 21 | Demolition of brickwork or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars, etc but exclusing ashlar facings, dressed stoneswork and precast concrete articles complete all as specified and as directed. |
| 22 | M&L for stone walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) including brought up to courses complete all as specified and as directed. |
| 23 | All as per srl item No 22.00here-in-above but except stone complete all as specified and as directed.NOTE:- Stone boulders obtained from srl item No 21.00 here-in-above shall be reused. |
| 24 | Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and as directed.NOTE:- Stone boulders obtained from srl item No 21.00 here-in-abpve shall be reused. |