| 1 | M&L for replacement of existing water level indicator in UG Sump/Semi UG Sump of any size , capacity and height by Float and board types level Guage using rope, ball valve, pully, necessary support , PCC , display board , indicator/ pointer , necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed. |
| 2 | M&L for replacement of existing water level indicator OHT of any size , capacity and height by Float and board types level Guage using rope, ball valve, pully, necessary support , PCC , display board , indicator/ pointer , necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed. |
| 3 | M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enamelled spray painting after scrapping / cleaning complete all as directed . |
| 4 | S&F in repair to digital type water level indicator system comprising digital display unit, sensor cable assembly, and stem insertion mechanism for accurate sensing and indication of water level in sump water reservoir. Work includes laying of PVC sheathed / PVC insulated copper conductor cable of size 0.5 Sqmm, 3 core from sensor to display unit if damaged, including PVC conduit, flexible for proper protection and routing of cable replacement of sensor, display unit if unserviceable. The unit shall be suitable for operation on 230 Volts, single-phase AC supply and shall be tested on completion to ensure proper functional performance, complete all as specified and as directed.Note: Cost of all spare parts, accessories, fittings, consumables and associated materials required for completion of the job shall be deemed to be included in the quoted rate |
| 5 | S&F in repair to digital type water level indicator system comprising digital display unit, sensor cable assembly, and stem insertion mechanism for accurate sensing and indication of water level in sump water reservoir. Work includes laying of PVC sheathed / PVC insulated copper conductor cable of size 0.5 Sqmm, 3 core from sensor to display unit if damaged, including PVC conduit, flexible for proper protection and routing of cable replacement of sensor, display unit if unserviceable. The unit shall be suitable for operation on 230 Volts, single-phase AC supply and shall be tested on completion to ensure proper functional performance, complete all as specified and as directed.Note: Cost of all spare parts, accessories, fittings, consumables and associated materials required for completion of the job shall be deemed to be included in the quoted rate |
| 6 | Description all as per ser item No 5 above but for of inside UG sump reservoir capacity of 200000 gallons . |
| 7 | Description all as per ser item No 5 above but for of inside UG sump reservoir capacity of 150000 gallons . |
| 8 | Description all as per ser item No 5 above but for over inside UG Sump/Semi UG sump reservoir of capacity 100000 gallons |
| 9 | Description all as per ser item No 5 above but for of inside UG/Semi UG sump reservoir capacity 50000gallons .. |
| 10 | Description all as per ser item No 5 above but for of inside UG/Semi UG Sump reservoir capacity of 25000 gallons |
| 11 | Description all as per ser item No 5 above but for of inside UG/Semi UG Sump of capacityaround 10000-15000 gallans . |
| 12 | Description all as per ser item No 5 above but for of inside overhead reservoir capacity 200000 gallons . |
| 13 | Description all as per ser item No 5 above but for of inside overhead reservoir capacity 100000 gallons . |
| 14 | Description all as per ser item No 5 above but for of inside overhead reservoir capacity 50000 gallons. |
| 15 | Description all as per ser item No 5 above but for of inside overhead reservoir capacity 40000gallons. |
| 16 | Description all as per ser item No 5 above but for of inside overhead reservoir of capacity25000 gallons . |
| 17 | Description all as per ser item No 5 above but for of inside overhead reservoir capacity 20000 - 24999gallons |
| 18 | Testing & checking the Quality of waterfor determining the following parameter pH, Turbidity, Colour & Odour, Total Dissolved Solids (TDS), Total Hardness, Calcium & Magnesium, Chlorides, Nitrates, Iron, Fluoride, Alkalinity, and other parameters as per IS 10500 potable water limits.Bacteriological (Microbiological) testing shall include Total Coliform Count, Faecal Coliform/E. Coli, as per applicable standards.as per IS: 10500-2012 and submit the test report from Govt Laboratory complete all as specified and as directed by Engr-in-Charge.Note: The testing and checking of Quality of water shall be executed once in 30 days or otherwise specified by Engineer-in-Charge. |
| 19 | Supply and Testing of following water testing solution :- |
| 20 | Supply and testing of OT solution for chlorine test (500 ml each) |
| 21 | Supply and testing of Iron Test solution (3 btls X 500 ml each) |
| 22 | S & F First Aid Kit ( With all medical items inside pre fitted Lock/ Mountable Metal Cabinet with size 36 cms L x 26 cm W x 12 cm D. Note: The followings medical items shall be available inside the First Aid box.a) Small Size Sterilized Dressing- 12 Nos b) Medium Size Sterilized Dressing- 8 Nos c) Large Size Sterilized Dressing- 8 Nos d) Large Size Burn Dressing- 6 Nos e) Antiseptic Solution 100 ml-1 Nof) Scissor-1g) Adhesive Tape 1/2-2 Nosh) Sterilized Eye Pad- 8 Nosj) Aspirin Tablets- 30 Nosk) Burn Ointment 15 gm- 1 Nosl) Eye wash cup- 1 Nosm) Snakebite lancet-1 Nosn) Small Size Sterilized Dressing- 12 Nos o) Medium Size Sterilized Dressing- 8 Nos p) Large Size Sterilized Dressing- 8 Nos q) Large Size Burn Dressing- 6 Nos r) Antiseptic Solution 100 ml-1 Nos) Scissor-1t) Adhesive Tape 1/2-2 Nosu) Sterilized Eye Pad- 8 Nosv Aspirin Tablets- 30 Nosk) Burn Ointment 15 gm- 1 Nosl) Eye wash cup- 1 Nosm) Snakebite lancet-1 Nos |
| 23 | S&F, including fabrication installation of Electrical Shock Treatment Chart in 450 GSM Backlit Printing framed inside top cover glass of size 3\"x2\" fixed with the help of supporting clamps/ nuts& blots fitted to wall with Iron base frame which includes strip lighting along outer periphery all as directed by Engr-in-Charge. (Sample is available with AGE E/M Office). |
| 24 | Supply, installation, testing and commissioning of LED-based Aviation Obstruction Light suitable for mounting on overhead water tank, of 10 Watt (low-intensity Type-A) , complete with high-brightness red LED beacon, UV-resistant polycarbonate/glass dome, weatherproof corrosion-resistant housing (minimum IP-65 protection), integrated LED driver, surge protection device, and heavy-duty mounting bracket. The unit shall operate on 230 Volts single-phase AC supply, and shall conform to relevant DGCA/ICAO guidelines for low-intensity obstruction lighting. Work includes all necessary wiring using suitable copper conductor cable, providing PVC /flexible conduit, clamps, fasteners, earthing connections and testing on completion, complete all as specified and directed.Make : Crompton/Bajaj/HavellsNote : Copper wire and cross arm used will be measured and paid seperately. |
| 25 | Supply,laying,jointing,testing andcommissioningPVC tape/Extruded innersheathedCopper unarmoured service wire, 650/1100 volts grade cross sectional area1.5 sqmm 3 core connectedwith lugs in PVC Conduit, clamps, fasteners connectedby cramping toolsall as specified and directed at site. |
| 26 | M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thickpacked layer of charcoal dust and common salt filled in alternate layers and electrode connections by usingGalvanised earth strip 32x6mmconnected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth wireand GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover,test point etc. |
| 27 | S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers,with saddles, clamps, poles at 1m intervals, complete all as specified and directed. |
| 28 | Material & Labour for earthing continuity conductor or main earthing lead fixed to wall of OHT or buried in ground or dawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25 x 4 mm Aluminium strip forconnection. |
| 29 | S&F air termination single pointed aluminium rod 12 mm dia 300 mm long with suitable nut, bolts, screws, washers & complete all as specified by Eng-in-Charge. |
| 30 | S&F of medium grade GI tubing 40 mm bore for fixing of air termination single pointed aluminium rod with necessary clamps, nuts, bolts and washers including silver painting over the surfaces of all rusted metallic surfacescomplete all as specified and directed. |
| 31 | S&F porcelain insulators of size 75 mm height and 25 mm width for fixing of aluminium and GI strip with suitable nut, bolts and washerscomplete all as specified and directed. |
| 32 | M&L for test pointterminal block made of gun metal or phosphores bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8 mm dia 25 mm longhex head screw complete all as specified and directed. |
| 33 | M&L mild steel as in cross arms bracing supports clamps and back planes fabricated from structural steel section including nut, bolts washers welding welding drilling holes for bolts in any shape and size as indicated or directedand inclusive of one proimer coat one undercoat one finishing coat of aluminium paint complete. paint complete to support the cables all as specified. |
| 34 | Supply and fixing in replacement of DI D/ F Gate valve (Soft Sealed) Resilient Seated Soft Sealing gate valves(Sluice valves) with body bonnet of ductile cast iron of grade GGG-40/ SG- 400/ 15 or GGG-50/ SG-500/ 7 or equivalent grade as per IS 3896 - Part 2- 1985 and subsequent revisions, Wedge fully rubber lined with EPDM Food grade quality and Seals of NBR and the valve should be vacuum tight and 100 % leak proof with face to face dimension as per BS 5163-89/ IS 14846-2000/ DIN 3202 F 4. and Valves should be electrostatic powder coating both inside and outside pocket less body passage class PN 1.6 including all jointing materials (Gasket , Nut bolts etc) connecting and testing complete all as specified and directed. Note : OLD SERVICEABLE VALVES TO BE DEPOSITED TO AGE E/M RANCHI STORE |
| 35 | 100 mm Dia |
| 36 | 150 mm Dia |
| 37 | Supply of chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill ( dia 2.5\" +0.5\") for disinfection of drinking water with arrangement for control release of disinfectant in water, suitable for operation through disong system. Make : Declibac (Type Stequa 411 AE)/ Equivalent.Note : The product media should have heavy metal contaminants below detachable limits and must pass the accute toxicity test (Confirm to non toxicity for mammalian cells ) and safe for human helath safety point. |
| 38 | Material and labour for dismantling and taking down defective chemical dozing system (complete assembly) from the mounting assembly for carrying out necessary repair etc including reassembling and fixing in position on the mounting arrangement including making necessary electrical/water/chemical hose connection complete making the system functional all as specified and directed by engineer Incharge. Note: Spare parts will be measured and paid seperately under respective items. |
| 39 | Replacement and fixing of roller assembly complete all as specified and directed. Make : Declibac, RMCO or other equivalent makes as approval by GE. |
| 40 | Replacement and fixing of # 7pump tube complete all as specified and directed. Make : Declibac, RMCO or other equivalent makes as approval by GE. |
| 41 | Replacement and fixing of injection check valve 3/8\"complete all as specified and directed. Make : Declibac , RMCO or other equivalent makes as approval by GE. |
| 42 | M&L Hi strength granular chlorination chemical based with CIAS (Corrosion inhibitor & Anti scalant) to be ratified by E-inC\"s Branch , Dry, Free flowing consistent white granules (or powder) and without hard lumps or impurities should not induce substances beyond acceptable limit as given in IS:10500:2012 in treated and disinfectant water, high strength granular chlorine having 65 % - 70 % chlorine content by mass packed in 45 Kgs non returnable PVC sealed container, 5-10% moisture content , upto 4% calcium hydroxideupto 15% sodium chloridesuitable for treatment of drinking water and swimming pool ( Much more stable than chlorine gas, bleaching power and sodium hypochlorite) all as specified and directed. |
| 43 | Cutting anxious green growth/ vegetation growth for cleaning out the area around OHT ans UG SUmp at ground level by cutting out roots, un wanted plants bushes and removal of the same by surface excavation not exceeding 30 cm deep average 15 cm complete |
| 44 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specially provided for |
| 45 | M & L for RCC (1:2:4) type B-1using 20 mm graded stone aggregateas in slab supported on wall ,Chajjas,deck slab Shelves/tank stagingetc. |
| 46 | Use & waste frame workto sides and soffits of floor or roof slab, chajjas not exc 200 mm thick (Horizontal or sloping) rough finished complete. |
| 47 | M & L Mild steel bars 10mm diaTMT Bars and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 48 | Demolition of brick wk masonry built in cement mortar incldg all quoins arches pillars etc |
| 49 | M&L brick work with sub class ‘B’ old sized bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 |
| 50 | M&L Providing, cement concrete type B0 1:2:4 (12.5 mm graded aggreate)as in coping etc similar work complete. |
| 51 | M&L rendering 10mm thick in CM 1:6 on fair faces of brick work , finished even and smooth without using extra cement. |
| 52 | M&L rendering 15mm thick in CM 1:4 on fair faces of brick work , finished even and smoothwithout using extra cement. |
| 53 | M & L preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete. |
| 54 | M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resisteance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade ( Company Depot tinted) with silicon additives @ 1.43 litre /10 sqm over and including priming coat of exterior primer appplied @ 0.90 litre /10sqm over a coat of wall putty on new plastered wall surfaces incl preparation. |
| 55 | S&F framed work such as grills, gratings etc. With ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming Fe 290, Gde -E -165 |
| 56 | M&Lfor preparation of new steel surafces of any description not otherwise described, over 10 cm width or girth, priming with a coat of red oxide primer and applyinng 2 coats of synthetic enamel paint of approved shade all as specified and directeed by EIC |
| 57 | M&L, applying one coats of synthetic enamel paintincluding preparation of old steel surfaces of any description over 10cm width or girth not otherwise described. |
| 58 | Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete. |
| 59 | S&F for Roof trusses (framed), trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc completeFe 410-W(Gde E-250) quality-A. |
| 60 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges as in roof covering complete. |
| 61 | S&F prepainted galvalume aluminium zink coating GI based corrugated/ semi - corrugated steel sheet 0.50mm thick of an colour having tensile strengthof 550 Mpa as in roof covering fixed with coach screw as per manufacturers instrution complete. |
| 62 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall and ridge,fixed with self tapping srews complete. |
| 63 | Taking down chowkats or frame with shutters (without taking off shutters from the frames) but Exc 1.5 and n. Exc 4 Sqm each |
| 64 | Powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 65 | Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified |
| 66 | S&F 5.50 mm thick plain sheet glass, area exc 0.5 sqm in each pane and fixed to aluminium frame work etc complete. |
| 67 | S&F 4 lever aluminium mortice lock vertical type size 65 mm long complete. |
| 68 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed. |
| 69 | S & F Aluminium die cost body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed |
| 70 | S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixibng bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as directed. |
| 71 | S & F Floor door stopper of aluminium alloy body and tongue, anodized, with hand drawn steel spring fixed in door, overall length of cover plate 150 mm |
| 72 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steelection made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of rame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately).Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 73 | S&F Aluminium anodised barrel tower bolts of extruded section and fixed 200 mm long. |
| 74 | S&F 4.0 mm thick plain sheet glass, area exc 0.5 sqm in each pane and fixed to aluminium frame work etc complete. |
| 75 | S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staples in repairs. |
| 76 | Dismantling of wall and ceiling board any thickness/description including cover fillet. |
| 77 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer\"scomplete all as specified. |
| 78 | M&L 4mm thicknon asbestos fibre cement designer building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping. |
| 79 | S&F PVC False Ceiling consisting of 600mm x 600mm, 5mm thick Plain embossed PVC sheet of Density 600 Kg/ Cum manufacturedby an ISO-900-2015 certified company, used as panel insert in a frame work made using aluminum “T” section of sizes 1” x 1” (25mmx25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2’x2’ (600mmx600mm). The aluminum framework to be supported from the ceiling with the help of ‘J’ hook and 6mm GI wire and 6mm MS rods of required sizes as directed to maintain proper level etc. The aluminum framework to be supported on side wall with the use of aluminum “L” section of size 1”x1” (25mmx25mm) angles etc complete as per direction of Engineer-in-Charge, manufacturer’s specification. |
| 80 | Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing ) removing serviciable tile to store & rubbish off the permisses. |
| 81 | M&L, 15mm thick screed bed or bedding layer of mortar in CM (1:6) for lying floor finishes and surface fair and even. |
| 82 | M&L double charged Vitrified ceramic tiles light shade 8 to 10 mm thick (square/rectangular) area of each tile notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete. |
| 83 | Description all as per ser item No 66 but as in verticle surface or skirting complete. |
| 84 | M&L, 10mm thick rendering as screed bed or bedding layer of mortar in CM (1:4) for lying tiles on vertical surface finishes. |