| 1 | M&Lfor servicingof split type AC 1/1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc. & Rectification of water leakage problem due to formation of Ice, leakage of refrigerantkeepingthe AC unit in satisfactory working condition after necessary servicing complete all specified and directed by Engineer-in-Charge. |
| 2 | S&F in repairs Running capacitor 2.5 to 10 MFD. (Make:- Epcos/ Usha/ Keltron.) |
| 3 | S&F in repairs Running capacitor 36 to 50 MFD. (Make:- Epcos/ Usha/ Keltron.) |
| 4 | S&F in repairs Starting capacitor 80 -120 MFD. (Make:- Epcos/ Usha/ Keltron.) |
| 5 | S&F in repairs artic board universal Remote control compatible for split AC of Cap 1.5/2.0 TR of any make and model as per site requirement as directed by Engr-in-Charge. |
| 6 | Supply & fixing in repairs of suctionand discharge valve set 15mm (5/8\"\") and 10mm (3/8\") for Split AC 2 TR capacity complete all as directed by Engr-in-Charge. |
| 7 | Supply & fixing in repairs ofsuctionand discharge valve set6mm (1/4\"\") and 12mm (1/2\"\")for Split AC 1.5 capacity complete all as directed by Engr-in-Charge. |
| 8 | Supply & fixing in repairs of capillary tube for Split/ Windowtype AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. |
| 9 | Supply & fixing in repairs of capillary filter for Split/ Windowtype AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. |
| 10 | Disconnecting the unserviceable PCB compatible from Inverter/non-inverterSplit type AC of capacity 1.5/ 2 TR and refixing after necessary repair for satisfactory functioning of the AC unit complete allas specified and directed by Engineer-in-charge. |
| 11 | Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the split type Air Conditioner of Cap 1.5 Ton,of any make any type from any locationandSupply , Installingand testing of new sealed unit compressoralong with test certificate from manufacturer includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc&Charging of Gas R-22/R-32/R-410a and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) |
| 12 | Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the split type Air Conditioner of Cap 2 Ton,of any make any type from any locationandSupply , Installingand testing of new sealed unit compressoralong with test certificate from manufacturer includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc&Charging of Gas R-22/R-32/R-410a and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) |
| 13 | Supply & fixing in repair copper wounded Indoor Air blower motor with blade of existing Split AC 1.5/2 TR capacity complete all as specified & as directed. Make-AUE/Speed King/Cool Master. |
| 14 | Supply & fixing in repairs of copper wounded condenser fan motor with blade of existing Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) |
| 15 | Disconnecting the mains and taking out the unserviceable condenser coilof split type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make :- As per existing sample) |
| 16 | Supply & fixing in repairs of evaporator/cooling coil for split type Air Conditioner of capacity 1.5/ 2TRof existing make and size complete all as specified & as directed by Engr-in-Charge. |
| 17 | Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including, copper condenser coil, fan motor, chassis, base plate, including initial charging of gas complete all as specified & as directed by Engr-in-Charge. (Make:- Bluestar/Hitachi/Voltas) |
| 18 | Supply and fixing in repairs of 2TR capacity split type Air Conditioner outdoor kit including, copper condenser coil, fan motor, chassis, base plate, including initial charging of gas complete all as specified & as directed by Engr-in-Charge. (Make:- Bluestar/Hitachi/Voltas) |
| 19 | Taking down unserviceable indoor unit of split type AC of any make andsupply & fixing new indoor unit complete kit suitable for 1.5 TRcapacity including remote complete all as directed by Engr-in-Charge.(Make:- Bluestar/Hitachi/Voltas) |
| 20 | Taking down unserviceable indoor unit of split type AC of any make andsupply & fixing new indoor unit complete kit suitable for 2 TRcapacity including remote complete all as directed by Engr-in-Charge.(Make:- Bluestar/Hitachi/Voltas) |
| 21 | Supply & fixing heavy duty copper pipe 12 mm (1/2\") dia/ bore complete includingnitrile rubber insulation, brazing, welding, nuts,bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 22 | Supply & fixing heavy duty copper pipe6mm (1/4\") dia/ bore complete includingnitrile rubber insulation, brazing, welding, nuts,bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 23 | Supply & fixing heavy duty copper pipe15mm (5/8\") dia/ bore complete includingnitrile rubber insulation, brazing, welding, nuts,bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 24 | Supply & fixing heavy duty copper pipe 10mm (3/8\") dia/ bore complete includingnitrile rubber insulation, brazing, welding, nuts,bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 25 | Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitable for Split AC of capacity from 1.5 to 2.0 TR all as specified and directed by Engineer-in-charge. |
| 26 | M&L for replacement of PVC pipe 20mm dia heavy duty with all fittings (bend, elbow, tee) etc including fixing with clamp on wall or floor for AC drain pipe with drain cap complete as directed.Make Astral / Prince and equivalent. |
| 27 | S&F of Air filter sheet for 2.0/ 1.5/1.0 Ton AC including taking down old U/S one complete all as specified and directed by Engr-in-Charge. |
| 28 | Supply and fillingrefrigerant gas R-22/R-32/R-404a/R-407c/410a in window /Split Type AC unit of capacity 1.5/2 TR andin compressors of Cold storage units of any capacity as per OEM specification including detecting the leakage of gasat any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.Make : Mefron/Floron/Refron. Note :- The rates quoted by the contractor for topping up/ filling of refrigerant gas shall deemed to include leakage detection, rectification of leakage by brazing, nitrogen pressure testing, etc. |
| 29 | Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 2.0 TR all as specified as directed by Engineer in-charge. |
| 30 | Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal cross sectional area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequate size with all fittings and casing capingaccessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) {Notes :-(i) Two runs of cable with one run of earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} |
| 31 | Supply and fix in repairs single pole andneutral enclouser with a two pin andearth plug and socketcomplete with and including one MCB single pole 20 Amps complete all as specified and directed. |
| 32 | Supply and fix in repairs MCB SP 6-32 amp rating 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.Make: Indo Asian/ L&T/Crompton Greaves/Havells |
| 33 | Servicing of air curtains, single phase, 240V by checking all electrical connection, blower, motor oiling greasing and replacement of u/s wire, lugs, bushes, rubber pads, bearing etc. all as directed by Engr-in-charge. |
| 34 | Fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through wallwith connected accessories such as mounting bracket with fasteners, copper tubing & elect power cord cable from indoor to out door unit and drain water pipe etcas per site requirement all as specified and directed. |
| 35 | S&F Heavy duty stand for air conditioner outdoor condensing unit as per existing make model complete with nut, bolt & washer complete all as specified and directed by Engineer-in-Charge. |
| 36 | S&F in repairs FRLSH round PVC insulated multistranded copper conductor cable Three core of size 2.5 Sqmm complete as directed. Make - Havells/Finolex/Plaza |
| 37 | Supply and fixing in repairs new PCB suitable for LG (Dual inverter)/Hitachi/Voltas/Panasonic of any make for indoor/outdoor units of inverter ACs of capacity 1.5/2 TR complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L for disconnecting the unserviceable DC condenser fan motor with blade of outdoor units and Supply, fixing & testing for proper functioning of existing LG (Dual inverter)/Hitachi/Voltas/Panasonic make Inverter ACs of capacity 1.5/2 TR |
| 39 | M&L for Scrapping of old painted surface area of condensing unit of Split/window type AC 1.0/1.5 /2.0 ton capacity dusting cleaning thoroughly and spray painting with two coats of synthetic enamelled paint over a coat of red oxide primer to match with the existing colour complete all as directed by Engr-in-Charge. Note : one job include painting of one condensing unit of split/window tye ac all as specified and directed by Engr-in-charge. |
| 40 | M&L for taking out existing unserviceable scroll compressorand replace with new compressorsuitable for working on380-415V 3 phase , 50Hz, LR : 87A, having lubricant : PVE / 1.6 L suitable for R-407C refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make-Danfoss scroll compressors Model No- HLP072T4LC6 or equivalent. |
| 41 | M&L for taking out existing unserviceable scroll compressor and replace with new compressorsuitable for working on220-240V 1 phase , 50Hz,suitable for R-22 refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make-EMERSON Copeland scroll compressors Model No- CR22K6M-PF1-111DM or equivalent. |
| 42 | M&L for taking out existing unserviceable scroll compressorand replace with new compressorsuitable for working on380-415V 3 phase , 50Hz, suitable for R-404a refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make-Danfoss scroll compressors Model No- ZB21KQE-TFD-524/ZF15KQE-TFD 551 or equivalent. |
| 43 | M&L for replacement of unserviceable blower motor3 Phase, 415 V, 50 HZ, 0.75-1 HP 1400 RPM, S1 duty, Frame-80of air cooled AC plant (5.5 TR) as per existing make, model and type complete all as directed by Engr-in-charge. |
| 44 | S&F in replacement of blower belt of AHU / Compressor belts as per existing model and type ISI marked including re-alignment of the motor and blower if required for proper tension of belts as directed by Engr-in-charge. |
| 45 | M&L for replacement of unserviceable fan motor with blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) as per existing make, model and type complete all as directed by Engr-in-charge. |
| 46 | Supply and filling/topping up refrigerant gas R-22/R134a/R-404A/R-407C/410A/R-507/R-513A in scroll compressors of package type AC plants of any capacity as per OEM specification including detecting the leakage of gasat any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.Make : Mefron/Floron/Refron. Note :- The rates quoted by the contractor for topping up/ filling of refrigerant gas shall deemed to include leakage detection, rectification of leakage by brazing, nitrogen pressure testing, etc. |
| 47 | M&L for Servicing outdoor units & ducting of air cooled central/ Package type AC plant5.5 TRthrough OEM service Engineer having min 5 yrs. experience by cleaning of cooling coil by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of blower motor, etc. complete as specified by OEM and directed by Engr-in-charge. Make of installed plant- Blue Star |
| 48 | Labour only for servicing of Main Electric Panel board / Control panel board of Central / Package type AC Plant by cleaning the panel with blower, replacement of unserviceable burntwire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unserviceable item (taken as supply only) as directed by Engr-in-charge.Note : -(i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately under relevant items of BOQ at supply only rates.(ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in rate quoted against this item. |
| 49 | Supply only the following for above items (Make- Hager/Legrand/C&S/L&T/Merlin Gerin) |
| 50 | Supply only MCB 6-32 Amp SP C series |
| 51 | Supply only MCBTPN 40 to 63Amp C series |
| 52 | Supply only MCBTPN 10 to 32 Amp C series |
| 53 | Supply only Add on Auxiliary contact block (MNX A-2 /MNX A-1/TA1-DN22) |
| 54 | Supply only Voltage selector switch |
| 55 | Supply only Voltage monitoring relay (240 Un) |
| 56 | Supply only Digital panel meter (current,voltage,temperature) |
| 57 | Supply only Electronic Timers 110 / 240 / 360 / 415Volts 50 Hz for(3-10/ 9-30/36-120 Sec) |
| 58 | Supply onlyR / Y /B Phase / On / Trip indicating lamps (as per colour code) |
| 59 | Supply onlyContactor MNX9 |
| 60 | Supply onlyMCCB 32A 3 pole with extended rom |
| 61 | Supply onlyMCCB 63A 4 Pole |
| 62 | Supply only MCCB 100A 4 Polewith extended rom |
| 63 | Supply onlySingle phase preventer suitable for 3 HP to 15 HP Monoblock pump sets (Make Minilic) |
| 64 | Material and labour for taking out unserviceable burnt electric motor of (Monoblock pump set / Blower / condenser / cooling tower) 2 HP single / three Phase and rewinding the sameby removing the burn out copper coil cleaning the motor and winding with super enamel copper wire of same gauge & turns including varnishing, providing new insulation sheet, heating the winding including replacement of unserviceable both endbearings, bush of existing size etc reqd at site, refixing to its original place and testing after repair complete all as specified and directed by Engr in charge. Note: Rates for transportation from site to workshop & return shall be deemed to be included in quoted rates. |
| 65 | M&L for submain wiring alongwith PVC insulation FRLS with standared copper conductor single core cable of size 2x6.0 Sqmm + 1x6.0 Sqmm as in earth continity earth wire ISI markeddrawnthrough and incl PVC casing and caping as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Shall run of PVC wire and one run of earth wire with one run of conduit shall be measured and paid as one unit length.) |
| 66 | M&L for replacement ofRefrigerant hermetic drier filter (1 - 5.5 TR) as per existing model & typeMakeincludingbrazing and making leak proof complete all as reqd at site & directed by Engr in Charge |
| 67 | M&L for replacement of single phase Axial fan motor 220V, 50 Hz, 0.42A, 90W, 1350 RPM CE certified weather proof cooling coil motor suitable for cold storage 0 to -18o C.Make- Osaka Shoji Kaisha Ltd / HI cool |
| 68 | M&L for replacement of unserviceable digital controller model No BSL52 of Blue Star suitable for cold storage 1/1.8 Ton cap having -2o to -10o C temp rangecomplete with sensor & control wiring.Make- Blue Star |
| 69 | M&L for replacement of Existing unserviceable digital cold room temp controller model CCR-2052with MCB of Sub Zero suitable for cold storage 1.8 Ton cap having -0 to -18 oC temp rangecomplete with sensor & control wiringMake - Sub Zero |
| 70 | M&L for replacement unserviceableof SS hinges of cold storage unit as per existing type & modelcomplete as required at site & directed by Engr in Charge.Note: Two no\"s of SS hinges for bottom and top measured as one unit. i.e., \"Each Set\" |
| 71 | M&L for replacement of unserviceable door stopper of cold storage as per existing type & model complete all as specified & directed |
| 72 | Replacement of unserviceable HP / LP cut outsasper model & type including cutting, brazing complete as specified & directed by Engr in Charge |
| 73 | M&L for Servicing Indoor & outdoor units of cold storage through OEM service Engineer having min 5 yrs experience by cleaning of cooling coil by using with water spray jet. chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of blower motor, etc. complete as specified by OEM and directed by Engr-in-charge. Make of installed plant- Blue Star |
| 74 | M&L for Scrapping of old painted surface area of condensing unit of package type AC plants capacity (5.5 - 7.0 TR) dusting cleaning thoroughly and spray painting with two coats of synthetic enameled paint over a coat of red oxide primer to match with the existing colour complete all as directed by Engr-in-Charge. Note : one job include painting of one condensing unit of ac plant/package type/cold storage all as specified and directed by engr-in-charge. |
| 75 | M&L for replacement of unserviceable fan motor with blade of outdoor condenser unit of cold storage upto 2 TR as per existing make, model and type complete all as directed by Engr-in-charge. |
| 76 | M&L for replacement of unserviceable condenser coil of outdoor unit of cold storage upto 2 TR as per existing make, model and type complete all as directed by Engr-in-charge. |
| 77 | M&L for repair replacement of solenoid valve/coil 230V 50hz, 12W 22VA as per existing make, model and type complete all as directed by Engr-in-charge. |
| 78 | Schedule of Credit (Minus) Rs.36720.00NOTE: Bidder shall insert credit amount of Rs. 36720.00 as ratein Green field under Col-13. |