| 1 | Supplying, erecting, testing and commissioning ofOut Door type 1000KVA capacity Copper wound Distribution Transformer 11 KV /433V with off Load Tap switch,Buchholzrelay,windingtemperature indicator, oil temperature indicator, marshalling box with wiring , magnetic oil level indicator andtaps ,with +5% to -5% steps of 2.5% with HT and LT cable end boxes including all standard accessories as per latest IS standardand as per Technical Specification. |
| 2 | Design, fabrication, supplying, testing and commissioning of outdoor Panel board made out of 16/18-gauge CRCA sheet powder coated, 3ph & N, 440volts, 50Hz, with 800A, 50KA, FP, MDO Air Circuit Breaker with Microprocessor based – 1 No, Under Voltage Release – 1 No, LTPB – 1 No., RYB Indicator (LED) – 1 Set, CT Ratio: 800/5A – 3 Nos., 6A FP MCB – 2 Nos., Multi-Function Meter – 1no, Trivector Meter-1 No., 50x10mm copper bus bar with heat shrinkable colour sleeves, RYB indicator, installation and coupling to the existing panel and inter wiring and making suitable foundation etc. complete and as per Technical Specification. |
| 3 | Design, Fabrication, Supplying, testing and Commissioning of Free standing Floor mounting Outdoor LT Control Panel board made out of 3ph, & N, 440 volts, 50Hz, with 1.5mm thickness AISI 304 Grade Stainless steelwith a) 630A, 50kA, 415V, Four Pole MCCB - 1 No. b) 250A, 35kA, 4P MCCB – 8 Nos.c) 200A, 35kA, 4P MCCB – 4 Nos.d) 40A,10kA, 4P MCCB-10 Nos.e) RYB Indicator – 1 set f) CT-400/5A - 3Nos.g) 6A, SP MCB - 2 Nos. h) Analog Voltmeter 0-500V + Selector Switch – 1 No.i) Analog Ammeter 0-400A + Selector Switch – 1 No.j) Multi-function meter - 1 No. 40X10mm copper bus bar with heat shrinkable color sleeves, internal wiring and making suitable foundation etc. complete. (Approximate Dimension:2000mm (H) x 3000mm (W) x 500mm (D) |
| 4 | Design, Fabrication, Supplying, testing and Commissioning of Free standing Floor mounting Outdoor LT Control Panel board made out of 3ph, & N, 440 volts, 50Hz, with 1.5mm thickness AISI 304 Grade Stainless steelwith a) 630A, 50kA, 415V, Four Pole MCCB -1 No. b) 250A, 35kA, 4P MCCB – 6 Nos.c) RYB Indicator – 1 set d) CT-400/5A - 3 Nos.e) 6A, SP MCB - 2 Nos. f) Analog Voltmeter 0-500V + Selector Switch – 1 No.g) Analog Ammeter 0-400A + Selector Switch – 1 No.h) Multi-function meter - 1 No. 50X10mm copper bus bar with heat shrinkable color sleeves, internal wiring and making suitable foundation etc. complete. (Approximate Dimension:1800mm (H) x 2500mm (W) x 500mm (D) |
| 5 | Design, Fabrication, Supplying, testing and Commissioning ofWall mounted Distribution Panelmade out of3ph, & N, 440 volts, 50Hz, with 1.5mm thickness AISI 304 Grade Stainless steelwith a) 200A, 25Ka, 415V, FourPole MCCB - 1 No. b) 63A, C-type, 10ka 4P MCB - 08 Nos. c) 25sqmm CBT cable connectors - 50 Nos. d) Din Rail - 2mtrs.e) 25x10mm copper bus bar -1.5 Mtrs, with heat shrinkable color sleeves, internal wiring using 4sqmm copper wires and wiring complete. Etc. Approximate Dimension : 600mm(W) X 600mm(H) X200mm(D) |
| 6 | Supplying, testing and CommissioningofWall mounted3ph, & N, 440 volts, 50Hz, 6-WayTPNDistribution Board and Complete wiring witha) 40A 10kA, 415V, FourPoleMCB - 1 No. b) 25A 10kA, SP MCB - 8 Nos.c) 20A 10kA, SP MCB - 8 Nos. |
| 7 | Providing MS stand made of angular frame size 3.5 mtrs Length x 2.3 mtrs width and made of 50mmx50mm, 6mm thickness with suitable angular legs and red oxide paint with two coats of Black paint and Complete job. |
| 8 | Providing MS stand made of angular frame size 2.3 mtrs Length x 2 mtrs width and made of 50mmx50mm, 6mm thickness with suitable angular legs and red oxide paint with two coats of Black paint and Complete job |
| 9 | Supplying, fixing and wiring earth electrode for grounding conduits, IC cutouts and other equipments on the meter board using 50mm dia, 2.90mm thick GI pipe 2.5 mtr long with GI funnel with mesh and suitable size reducer fixed on the top of electrode and 600X600X3 mm GI plate. The funnel should be enclosed in a cc chamber of 400 x 400 x 400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber.As per latest IS standards, technical specifications. |
| 10 | Supplying, fixing and wiring earth electrode for grounding conduits, IC cutouts and other equipment’s on the meter board using 50mm dia, 2.90mm thick GI pipe 2.5 mtr long with GI funnel with mesh and suitable size reducer fixed on the top of electrode and 600X600X3 mm Copper plate. The funnel should be enclosed in a cc chamber of 400 x 400 x 400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber.As per latest IS standards, technical specifications. |
| 11 | Supplying and running of GI/Cu strips for grounding connections using necessary fixing materials like insulators, welding, painting, nut/bolts/screws etc., as required as per latest IS standards, technical specifications. (Exposed earthing strips should be properly insulated).a) 50 x 6 mm Cu Strip |
| 12 | Supplying and running of GI/Cu strips for grounding connections using necessary fixing materials like insulators, welding, painting, nut/bolts/screws etc., as required as per latest IS standards, technical specifications. (Exposed earthing strips should be properly insulated).a) 40 X 6 mm GI Strip |
| 13 | Installation, Testing and Commissioning Wall mounting Split Air Conditioner units with allied works for one Indoor and one outdoor unit is to be mounted on suitable Iron angle supports with all necessaries materials like Foam, Wrapping tape, White cement etc. as a compete job. |
| 14 | Supplying of 1.1 KV LT Aluminum UG cable XLPE insulated, PVC extruded inner sheath armoured UG LT cable as per IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms as per IS-3975 3.5 core x 240 sq.mm |
| 15 | Supplying of 1.1 KV LTAluminium UG cable XLPE insulated, PVC extruded inner sheath armoured UG LT cable as per IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity14 Ohms/Kms as per IS-39753.5 core x 120 sq.mm |
| 16 | Supplying of 1.1 KV LT Aluminium UG cable XLPE insulated, PVC extruded inner sheath armoured UG LT cable as per IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms as per IS-3975 3.5 core x 95 sq.mm |
| 17 | Supplying of 1.1 KV LT Aluminium UG cable XLPE insulated, PVC extruded inner sheath armoured UG LT cable as per IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms as per IS-3975 4 core x 35 sq.mm |
| 18 | Labour charges for laying of 1.1 KV class XLPE LT UG Cables in existing trench/GI pipe/Stoneware pipe/on pole/on concrete wall as required 3.5C x 240 sq.mm |
| 19 | Labour charges for laying of 1.1 KV class XLPE LT UG Cables in existing trench/GI pipe/Stoneware pipe/on pole/on concrete wall as required3.5C x 120 sq.mm |
| 20 | Labour charges for laying of 1.1 KV class XLPE LT UG Cables in existing trench/GI pipe/Stoneware pipe/on pole/on concrete wall as required 3.5C x 95 sq.mm |
| 21 | Labour charges for laying of 1.1 KV class XLPE LT UG Cables in existing trench/GI pipe/Stoneware pipe/on pole/on concrete wall as required 4C x 35 sq.mm |
| 22 | Supplying and making end termination with glands, lugs of LT cables. 3.5C x 240 sq.mm |
| 23 | Supplying and making end termination with glands, lugs of LT cables.3.5C x 120 sq.mm |
| 24 | Supplying and making end termination with glands, lugs of LT cables.3.5C x 95 sq.mm |
| 25 | Supplying and making end termination with glands, lugs of LT cables. 3.5C x 35 sq.mm |
| 26 | Supplying and wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694: confirming to latest amendments.2.5 sq.mm |
| 27 | Supplying and wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694: confirming to latest amendments.4 sq.mm |
| 28 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage up to 1100 Volts as per IS-694:19904C x 2.5 sq.mm |
| 29 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 50 mm |
| 30 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm |
| 31 | Supplying and fixing of 4KVA Electronic Voltage stabilizers for the 1.5 Ton Air Conditioner.Working Range: 170V -270V AC, 50Hz.Time Delay: 3Min. ± 20Secs. ITDSCapacity: 12 Amps. |
| 32 | Supplying and fixing of 5KVA Electronic Voltage stabilizers for the 2 Ton Air Conditioner.Working Range: 170V -270V AC, 50Hz.Time Delay: 3Min. ± 20Secs. ITDSCapacity: 15 Amps |
| 33 | Supplying and fixing of heavy duty MS Wall mounting brackets for Outdoor Split Air Conditioner units with painting and required items as a complete job. |
| 34 | Supply and fixing of 25A Metal socket set of2 pole earth plug and socket. The entire plug and socket shall be mounted in a thermoplastic/power coated metal box and wired completely. |
| 35 | Supplying and fixing of DP 2 way enclosure box flush mounting using with provision for fixing suitable type Capacity MCB’s DP with power coated painting. |
| 36 | Supplying and fixing of 3/4” heavy duty PVC drain pipe with required elbows/Tee/bend/ saddles etc. as a complete job. |
| 37 | Supplying and laying of 5/8” Air Conditioner copper pipe with nitrile rubber insulation. |
| 38 | Supplying and laying of 3/8” Air Conditioner copper pipe with nitrile rubber insulation. |
| 39 | Supplying and fixing miniature circuit breakers on existing MCB distribution board using necessary fixing materials and ‘C’ type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.20 Amps DP |
| 40 | Supplying and fixing miniature circuit breakers on existing MCB distribution board using necessary fixing materials and ‘C’ type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 25 Amps DP |
| 41 | Core Cutting |
| 42 | Digging of trench of 0.6 x 0.5 m wide refilling the trench to the required ground level and consolidating etc. complete.Hard soil |
| 43 | Cutting of Road surface for cable trenches and disposing of the excavated earth, as directed including Barricading, then refilling the cable.Tar Road |
| 44 | Supplying and laying of RCC pipe NP3 for culverts including pointing ends and fixing collars with cement mortar 1:2 including cost of materials, labour, curing HOM complete as per specifications. No. KSRB 1000, 2300. 300 mm dia |
| 45 | Providing and laying in position plain cement concrete of mix 1:2:4 with cement @240kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.459 cum, machine mixed, concrete laid in laers not exceeding 15 cms. Thick, well compacted, for coping including cost of all materials, labour, HOM, curing complete as per specifications. No. KBS 4.1, 4.2 |
| 46 | Earthing - Supplying, fixing and wiring earth electrode for panel using 40 mm dia, 2.90 mm thick GI pipe 2.5 Mtr long with funnel with mesh and suitable size reducer fixed on the top of the Electrode. The funnel should be enclosed in a CC chamber of 400x400x400 mm with cast iron cover. The electrode shall have staggered holes of 12mm dia and the electrode covered 150mm all-round with alternate layers of salt and char coal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts |
| 47 | Supplying and running GI strip for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip |
| 48 | Releasing 70 sqmm of 1.1 KV LT Aluminium UG cable XLPE insulated, PVC extruded inner sheath armoured UG LT cable and making new end termination with glands, lugs of LT cables. 70 sq.mm |
| 49 | Releasing of 120Sqmm 1.1 KV LT Aluminium UG cable XLPE insulated, PVC extruded inner sheath armoured UG LT cable and making new end termination with glands, lugs of LT cables.120 sq.mm |
| 50 | Releasing of 400Sqmm 1.1 KV LT Aluminium UG cable XLPE insulated, PVC extruded inner sheath armoured UG LT cable and making new end termination with glands, lugs of LT cables400 sq.mm |
| 51 | Releasing of existing Panel Board with 500KVA Transformer and shifted to ESD-I. |
| 52 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Note: The dismantled steel bars shall be taken away by the Contractor and the cost of salvage materials shall be deducted from the bill. |
| 53 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge-In cement mortar. |
| 54 | Earth workexcavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such similar works in all kinds of soils, as per drawing and technicalspecifications, including setting out,shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting &stacking the selectedstuff for reuse in a radius of50 m and lift upto 1.5 m including cost of labour, tools & other appurtenances required to complete the work -Depth exceeding 1.5m, but not exceeding 3 m. |
| 55 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. |
| 56 | Providing and laying in position Cement Concrete (M10) for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-Including the Formwork Charges. |
| 57 | Providing and laying in position Cement Concrete for all Foundation works. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -Including the Formwork Charges. |
| 58 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. All other type of structures. |
| 59 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. |
| 60 | Painting Two Coats on New Concrete Surfaces; Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. |