| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 2 | 3 x 1.5 sq.mm |
| 3 | 3 x 2.5 sq.mm |
| 4 | 3 x 4 sq.mm |
| 5 | 3 x 6 sq.mm |
| 6 | Supplying and fixing following size/modules GI box along with modular base and cover plate for modular switches in recess etc as reqd |
| 7 | 3 Module (100mmX75mm) |
| 8 | 6 Module (200mmX75mm) |
| 9 | 8 Module (125mmX125mm) |
| 10 | 12 Module (200mmX150mm) |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 12 | 5/6 amps switch |
| 13 | 3 pin 5/6 amps socket outlet |
| 14 | 15 /16 amps switch |
| 15 | 6 pin 15/16 amp socket outlet |
| 16 | Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \"C\" curve including connections, painting etc. as required. |
| 17 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 18 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 19 | Group C |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 21 | Group C |
| 22 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 23 | S/F of 25mm x5 mm G.I strip on surface or in recess i/c making connection as reqd |
| 24 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 25 | Supplying and fixing of Heavy duty PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 26 | 25 mm dia |
| 27 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | 8 way (4 + 24), Double door |
| 29 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) |
| 30 | 12 way , Double Door |
| 31 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of single pole MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 32 | Single pole |
| 33 | Double pole |
| 34 | Three pole and neutral |
| 35 | Supplying and fixing 2 module stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd. |
| 36 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 37 | 63 A |
| 38 | Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB),having aensitivity current 100 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required |
| 39 | 40 A |
| 40 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 41 | 4x16 sqmm+ 2x6 sqmm |
| 42 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 43 | Supply, Installation, testing and commissioning of pre-wired, double box type fitting with two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 44 | SITC of 12 inch heavy duty, AC, single phase 230 Volt,50 HZ, 1350 RPM, steel body exhaust fan in existing opening,i/c making good the damage, cable connectionetc etc. as reqd |
| 45 | Supplying and Fixing of snap-on DLP trunking of size 105mm x 50 mm with cover and including accessories such as cover, Flat angle, end caps, internal/external angle support etc. on the wall/surface complete all as requied. |
| 46 | Supply, Installation, testing and commissioning of pre-wired, 150 watt, flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP66 protection, 130lm/w, 220-240 V, 50 Hzon existig street light pole/wall including all accessories and connection etc.as required..Philips Make, Cat No.BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent model of Thorn/Trilux |
| 47 | Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site. |