Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 2 | Material and Labour forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in cement mortar1:6 complete all as specified and directed. |
| 3 | All as per Srl item No 2 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 1 shall be reused after necessary cleaning of mortar). |
| 4 | Material and Labour forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, in half brick thick walls and built in cement mortar 1:4 complete all as specified and directed. |
| 5 | Taking down cement plaster on brick or concrete walls, ceiling etc, including racking out joints , hacking for key, scrubbing down with wateretc complete all as specified & directed by EIC . |
| 6 | Material and Labourfor rendering 5mm thick cement plasterin cement mortar (1:3) on concrete surfaces as in ceiling,finished even and smooth without using extra cementcomplete all as specified directed. |
| 7 | Material and Labourfor Rendering 15 mm thick in cement mortar 1:6 on brick or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | Material and Labour15 mm thick cement plaster in cement mortar 1:4mixed with liquid water proofing compound @ of 3%as on other than fair face of brick or concrete surface of walls finished surface faie and evenwithout using extra cement complete all as specified and directed.Note : Supply only water proofing liquid shall be measured and paid separately, complete all as specified directed. |
| 9 | Supply only liquid water proofing compound to mixed with cement mortar etc, complete all as specified directed. |
| 10 | Material and Labourpreparing New plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidonaddiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified upto height of 7.5 mtrs complete all as specified and directed. |
| 11 | Material and Labourpreparing old plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidonaddiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified upto height of 7.5 mtrs complete all as specified and directed. |
| 12 | Material and Labourpreparing New plastered surfaces on walls and applying one coat of primer paint and applying two coats of oil bound distemper over and including 1 mm wall care putty complete all as specified directed. |
| 13 | Material and Labourpreparing Old plastered surfaces comlete removal of existing treatment on walls one coat of primer paint, and applying two coat of oil bound distemper, complete all as specified directed |
| 14 | Material and Labourfor preparation of new plastered ceilingsurfaces and applying two coats of white wash complete all as specified and directed. |
| 15 | Material and Labourfor preparation of Old plastered surfaces complete removal of existing treatment on Ceiling and applying two coats of white wash complete all as specified and directed. |
| 16 | Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) complete all as specified and directed |
| 17 | All as per Srl item No 16 above but size of opening exceeding 1.5 Sqmr but not exceeding 4 Sqm. |
| 18 | Materialand labour in repair factory made Boxtypesteelwindow, ERW hollow P-Section size 60 mmx25mm, double rebated ERW section of 1.25mm thick, comprising of glazedskelton &gauzed shutter of ERW tube P-Section size 50mm x 20mmwith one No openable leaffor each shutter consisting of two Nos Sashbar of T-section 20 x 3 mmwelded to frame with one No verticle mullion of ERW box type T Section of size 60mm x 25mm and FI 2mm thick welded/screwed to frame for fixing of glass including fittings and fixture like as Handle, Tower Bolt, Stopper, Cleat, Pintal hinges, holdfast and guard bars etc as given below all as shown on drg No CEJZ/TD-1020/08 SH 1/3 to 3/3 dated 01 may 2008 complete all as specified and directed as follows:-(a) Hold fast 150mm long of MS flat 12mm x 3mm - 4 Nos per Window(b) Handle of Z section 20mm x 25mm, 100mm long- 01 No per leaf(c) MS tower bolt 150mm long - 02 Nos per leaf(d) Z Section stopper 20mm x 25mm, 100mm long - 01 No per leaf(e) Cleat 55mm long of hollow square 15mm, 0.63mm thick- 01 Nos per leaf(f)MS pintol hinges size 75mmx12mm - 2 Nos per leaf (g) MS guard bar 10mm square bars @10cm c/c fixed horizontly (h) 3mm thick clear glass sheet3 Nos per leaf glazing with oil putty(i)Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in each leafNote :- Including taking down old window including hold fast PCC 1:2:4 type B0 (four No’s for Each window) &required plaster in cement mortar 1:4 and match with existing finish complete all as specified and directed. Painting shall be measured and paid for separately. |
| 19 | Material and labour in repairs Box type steel ventilator made of ERW tube P-section of size 60mmx25mmouterframe ( single rebated), comprisesglazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing ofsheet glassincluding fixture and fittingslike as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD-1019/08 dt 01.05.08 incuding cutting holes complete all as specified and directed as follows.(a) 3mm thick pin headed type glass sheet glazing with oil putty and Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples of appropriate size.Note:- Including taking down old window including hold fast PCC 1:2:4 type B0 (four No’s for Each window) & required plaster in cement mortar 1:4 and match with existing finish complete all as specified and directed. Painting shall be measured and paid for separately. |
| 20 | Supply and fixingPresedsteel frames for doors Size of frame 105 x 60 mm with one or more rebates including necessary fixing lugs hinges lock strike plate, and including packing of PCC 1:2:4 type B0 inside the frame etc complete as specified supplied and directed. |
| 21 | Supply and fixingPresedsteel frames for doors Size of frame 125 x 60 mm with one or more rebates including necessary fixing lugs hinges lock strike plate and including packing of PCC 1:2:4 type B0 inside the frame etc complete as specified supplied and directed. |
| 22 | Material and Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in bed blocks for hold fast & similar work etc incl necessary form work complete all as specified and directed. |
| 23 | Supply and Fixing factory madeIInd class hard wood Glazed and skeleton shutters 35mm thick divided into square, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a) ; supplied and fitted to chowkats complete all as specified and directed. (Wire gauge, glazing and painting shall be measured and paid for separately). |
| 24 | Supply and Fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed |
| 25 | Supply and Fixing in repairs Helical door spring 300mm, ordinary rat tail rod pattern springs, including roller and roller plate fixed to iron chowkats with weilding complete all as specified and directed. |
| 26 | Supply and fixing30 mm thick Flush shutters , solid core construction , with block board core and covered with 0.50 mm thick laminate on both side wood grain texturewith lipping to match, complete all as specified and directed. |
| 27 | Supply and fixingfactory made 35 mm thick, 2nd class hardwood , glazed & Skeleton shutter open rebatedand prepared to receiveglass gauge etc without sash bars) edges of framing plain chamfered or founded, fitted with cut and mitered beads for securing glass etc size of members shutters as specified in SSR Part-I Section 8clause 8.24 (a) complete all as specified and directed. (Wire gauge, glazing and painting shall be measured and paid for separately). |
| 28 | Material and Labour two coats of synthetic enamel painting on wooden surfaces of any description over 10 cm in width or girth not otherwise described over pink primer including prepration of surfaces complete all as specified and directed . |
| 29 | Supply and Fixing 300mm long Aluminium alloy, Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 30 | Supply and Fixing Aluminium, anodised, barrel tower bolts 150mm of extruded section and fixed complete all as specified and directed. |
| 31 | Supply and Fixing 150mm longAluminium handles, cast type anodised complete all as specified and directed. |
| 32 | Supply and Fixing stainless steel butt Hinges, 100mm size, medium weight, cold rolled mild steel complete all as specified and directed. |
| 33 | Hacking out old broken glass fromwooden/ steel window cleaning the surface and removing from the site, thenafter Supply and Fixing clear glass, 3mm thick ordinary quality, in any shape, not exceeding 0.50 sqm in each pane includingand glazing with oil putty/wooden beading as per site requiremnets complete all as specified and directed. |
| 34 | Supply and Fixing clear glass, 3mm thick ordinary quality, in any shape, not exceeding 0.50 sqm in each pane includingand glazing with oil putty complete all as specified and directed. |
| 35 | Supply and fixingsolid PVC door frame of size 50X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification and directed. |
| 36 | Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC \"C\" chanel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheeets for top rail locj rail and bottom rail in either side and as gap insert for top rail and bottom rail, panelling ofg plain colour PVC sheets to be foitted in the MS frame wwelded/sealed to the stiles and rails with solvent cement all as specified and shown on drg,complete all as specified directed. |
| 37 | Supply and Fixing in repairpowder coatedaluminium frame for doors ,windows, ventilators, partition with one or more rebates including joining cleats, rubber neoprene packing for fixing complete all as specified and directed.( Min. thickness of powder coating 50 micron) |
| 38 | Supply and Fixing in repair powder coated aluminium glazedshutter(for doors) Al-section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading. ( Min. thickness of powder coating 50 micron) complete all as specified and directed. |
| 39 | Supply and Fixing in repair Aluminiumpowder coated (of any colour) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified .(Min. thickness of powder coating 50 micron) |
| 40 | Taking down in repair aluminium door shutters of area exc 1 sqm but n.exc 2 sqm each and replacement of necessary jointing cleats glazing clips, rubber packing, anodised aluminium snap beading screws etc and refixing in the same opening complete all as specified and directed.. |
| 41 | All as per item No 40 here in above but area not exc 1 sqm each window shutters. |
| 42 | Supply and Fixing in repair Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading with and incl solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturer scomplete all as specified and directed |
| 43 | Supply and Fixing in repairs door closer hydraulically regulated, (Alminium die cast body) designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weightbetween 61 to 80 Kg and fixed |
| 44 | Supply and Fixing in repair Double actionfloor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloysheet foundation box,main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed make-Godrej |
| 45 | Supply and Fixing in repair Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 150mm. |
| 46 | Supply and Fixing in repair Brass mortice lock, 4 levers, verticle type, size 100 mm, complete all as specified and directed. |
| 47 | Dismantling structural steel work including doors, gates and like complete all as specified and directed. |
| 48 | Dismantling of plain of corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof coveringcomplete all as specified directed. |
| 49 | Supply and fixingpre-painted galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50 mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 50 | Supply and fixingpre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall and vally gutter, fixed with self tapping screws complete all as specified and directed. |
| 51 | Supply and fixingin repairMild steel angle Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates etc.Fe290 Gde E-165,complete all as specified directed. |
| 52 | Material and Labour two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described above priming coat of red oxide including prepration of new surfaces complete all as specified and directed. |
| 53 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified directed. |
| 54 | Material and labour for coloured non skid matt finish ceramic tiles, 7 to 8 mm thick, (square/ rectangular),area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.min floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding screed bed or bedding layer of 15 mm thick cement mortar(1:6) complete all as specified and directed. |
| 55 | All as per item No 60 above but as indado, riser & skirting over & incl 10mm thick rendering in cement mortar 1:3 complete all as specified directed. |
| 56 | Supply and Fixing glazed ceramic coloured designer tiles 450mm x 350mm x 7mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in cement mortar 1:4 on brick surface complete all as specified and directed. Note: Colour and design of tiles as per approval of Engineer-in-charge. |
| 57 | Materialand Labourin repairs for facrory made Boxtypesteelwindowmade ofERW tube P- sectionof size 60 mmx25mm double rebated outer frame,comprises glazedskelton &gauzed shutterof ERW tube P-Section size 50mm x 20mmwith one/two Nos openable leaffor each shutter consisting of two Nos Sashbar of T-section 20 x 3 mmwelded to frame with one No verticle mullion of ERW box type T Section of size 60mm x 25mm and FI 2mm thick welded/screwed to frame for fixing of glass including fittings and fixture like as Handle, Tower Bolt, Stopper, Cleat, Pintal hinges, holdfast etc as given belowall as shown on drg No CEJZ/TD-1020/08Sh 1/3 to 3/3 dt 01 May 2008 complete all as specified and directed.(a) Hold fast 150mm long of 12mm x 3mm MS flat- 4 Nos per Window.(b) Handle of Z section 20mm x 25mm, 100mm long- 01 No per leaf.(c) MS tower bolt 150mm long - 02 Nos/leaf.(d) Z Section stopper 20mm x 25mm, 100mm long - 01 No per leaf.(e) Cleat 55mm long of hollow square 15mmx12mm - 02 Nos per leaf.(f)MS pintol hinges size 75mmx12mm - 2 Nos per leaf Note :- MS guard bars, sheet glass, wire mesh and painting shallbe measured and paid sperately |
| 58 | Material and Labourfor 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 59 | Material and Laboursand filling under floors including watering, well ramming,and consolidation complete all as specified and directed. |
| 60 | Material and Labourfor machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment complete all as specified and directed. (Sand filling beneath shall be measured and paid for separately). |
| 61 | Supply and Fixing in repairs vitreous ChinaSquatting pan \"Orrisa\" pattren size 580x440mm white with integral foot rest and PVC(SWR) \"P\" trap 110/110mm bore including provision of 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve flote handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia complete all as specified and directed. |
| 62 | Supply and Fixing in repairs vitreous China wash basinwhite,flat back size550x400mm including PTMT waste coupling 32mm bore,waste PVC pipe complete,CP brass Pillar Tap 15mm bore of fancy type complete all as specified and directed.. |
| 63 | Supply and Fixing in repairs glass shelve assembly 60cm in oval shape consisting 5.5mm to 8mm thick glass including CP guard railing with double rail complete all as specified and directed. |
| 64 | Supply and Fixing Sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass corner shelf with chromium plated bracket guard and railing complete all as specified and directed. |
| 65 | Supply and Fixing PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 66 | Supply and Fixing Vitrous china urinal partition white of size 310x770mm and fixed to wall terminating about 40cm above floor line with necessary fittings & fixtures etc.complete al as specified and directed. |
| 67 | Supply and Fixing in repairs 15mm bore Concealed type stop cock cast copper alloy CP screweddown high pressure with crutch or butterfly handle complete all as specified and directed. |
| 68 | Supply and Fixing in repairs 15mm bore type anglecock cast copper alloy CP screweddown high pressure with crutch or butterfly handle complete all as specified and directed. |
| 69 | Supply and Fixing in repairs of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass complete all as specified and directed. |
| 70 | Supply and Fixing in repairs Pillar taps 15mm bore, cast copperalloy , with capstan heads, chromium plated , screwed down high pressure , with or without l\"ettered \" \"HOT\" or \"COLD\" with long screwed shanks and fly-nuts , screwed for iron pipe and fixedcomplete all as specified and directed. |
| 71 | Supply and Fixing in repairs PVC wastepipe32mm dia fixed to WHB/Urinals complete all as specified and directed. |
| 72 | Supply and Fixing in repairs 100mm dia CP grating with or without hole type complete all specified and directed. |
| 73 | Supply and Fixing in repairs 600mmx450mm bevelled edge mirror of selected quality glass,mounted on 6mm thick commercial plywood incl all around teak wood beading and fixed to wall complete all as specified and directed. |
| 74 | Supply and Fixing in repairs CP brass towel rail of 20mm dia and 600mm long complete all as specified and directed. |
| 75 | Supply and Fixing in repairs 125mm CP shower rose fancy type with CP arm complete all as specified and directed. |
| 76 | Supply and Fixing 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down complete all as specified and directed. |
| 77 | Supply and Fixing 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down complete all as specified and directed. |
| 78 | Dismantling Brick tiles or terracing tiles, single layer on roofs; Complete all as specified and as directed. |
| 79 | Demolition mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof); Complete all as specified and as directed. |
| 80 | Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding concrete fair finish, roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating; Complete all as specified and as directed. |
| 81 | Material and Labour for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc; Complete all as specified and as directed. |
| 82 | Supply and Fixing (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire roof area with over lapping 100mm to either sides and sealed in after cleaning down the roof by brooms; Complete all as specified and as directed. |
| 83 | Material and Labour for 40mm thick brick tiles, laid on and including 15 mm thick cement mortar 1:6 and joints grouted and pointed flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement; Complete all as specified and as directed. |
| 84 | All as per Srl Item No. 83 here-in-before but except brick tiles. Note:-Old serviceable tiles obtained from dismanteling shall be reused. |
| 85 | Disconnecting existing tanks 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed. |
| 86 | Supply & Fixing in repairs rotational moulded polythene water storage tanks of 500 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore including dismantling old water tank complete all as specified and directed. |
| 87 | Dismantling boarding including frame , any description , fixed in any position with screws complete all as specified and directed. |
| 88 | Material and LabourforProviding and fixing Gypsum board 12 mm thick Seamless calcum silicate in ceilingmade out of 1800x1200 size board of siliceous and calcareous material reinforced with fixed with screw , GI frame work for seameless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws as 450mm centre to centr/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre andas per manufacturers instructions incl preparation of new surfaces & applyingtwo coat of OBD on ceiling over primer coat and preparation of surfaces withchalk whitening complete all as specified and directed. . |
| 89 | Supply and Fixing in repairs 25mm dia stainless steel Curtain rods/ rails,with brackets, stops, rollers, finials, 1 pair of decorative knobs for each curtain rod etc complete all as specified and directed. |
| 90 | Supply and Fixing in repairs PVC (SWR) pipe 75mm dia fixed in wall/floor complete all as specified and directed. |
| 91 | PVC (SWR) pipes single110mm socketed, in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and directed. |
| 92 | Supply and Fixing in repairs 75mm PVC (SWR) bends any radius complete all as specified and directed. |
| 93 | Supply and Fixing in repairs 110mm PVC (SWR) bends any radius complete all as specified and directed. |
| 94 | Takingdown Shutters of any description exc 2 sq. m each (Old rolling shutter) complete all as specified and directed. |
| 95 | Supply and fixing in repair1.25mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated, complete, but gear operated type with bevel gear box and crank handle,etc,complete all as specified directed. |
| 96 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 97 | Material and labour for Polishing rubbingmirror finishtwo coat of oldcut kota stone slab flooringover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete to complete all as specified and as directed |
| 98 | Material and labour for Machine cut kota stone slab flooring20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete to achieve mirror finish laid over & including 20 mm thick screed bed in cement mortar1:6 complete all as specified and as directed. |
| 99 | Material and labour for Machine cut kota stone slab flooring 16-18mm thick in riser of steps skirting dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete to achieve mirror finish laid over & including 10 mm thic screed bed in CM 1:6 complete all as specified and as directed |
| 100 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed |
| 101 | Material and Labour forpoint wiringin existing concealed conduit for following point ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn through and existingPVC concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using CM (1:3) including fixing of switch/socket/regulator/ etc complete all as specified and as directed. Note:1. Switche/socket/regulator/ceiling rose/bell.etc shall be measured and paid for separately.a) For one light /fan/ buzzer point controlled by one 5 Amp switch one way |
| 102 | b).For one three pin socket outlet 5 Amps independent board complete |
| 103 | c) For one three pin 5 Amps socket outlet on the same board with other switches |
| 104 | All a per item No 101 here-in-abovebut with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper multi stranded conductor connecting to common earth dolly complete. |
| 105 | Material and Labour for surface point wiring for following point ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn and including surface PVC conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using CM (1:3) including fixing of switch/socket/regulator/ etc complete all as specified and as directed. Note:1.Switche/socket/regulator/ceiling rose/bell etc shall be measured and paid separatelya) For one light /fan/ buzzer point controlled by one 5 Amp switch one way |
| 106 | b).For one three pin socket outlet 5 Amps independent board complete |
| 107 | c) For one three pin 5 Amps socket outlet on the same board with other switches |
| 108 | All a per item No 105 here-in-abovebut with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper solid conductor connecting to common earth dolly complete. |
| 109 | Supply and fixing Modular switch flush type one way 6 Amp, 230 volts complete all as specified and directed. |
| 110 | Supply and fixing Modular socket 6 Amp 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 111 | Supply and fixing Modular switch flush type one way 16 Amp, 230 volts complete all as specified and directed. |
| 112 | Supply and fixing Modular socket 6 /16 Amp 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 113 | Supply and fixing ceiling rose 65X50 mmthree terminals complete all as specified and directed. |
| 114 | Supply and fixingLamp holder bakellite type with black plate suitable for batten fitting complete all as specified and directed. |
| 115 | Supply and fixing Modular stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd heavy duty 230 voltscomplete all as specified and dircted. |
| 116 | Supply and fixingin replacement sheet metal enlosure DBs double door factory made flush fixed complete with 200 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified and directed. |
| 117 | Supply and fixing in replacement MCB single pole 6 to 32 Amps all as specified and directed. |
| 118 | Supply and fixing in replacement MCB DP 40 Amps 240V, 10 KA, complete all as specified and as directed |
| 119 | Supply and fix, in replacement Fresh Air fan of size 250mm, Plastic body 1200RPM, electrically driven, 230volts, 50Hz, single phase, AC supply, copper wounddynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3\" long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to fan all as specified and directed. Note: Making suitable opening for fixing air fan as required shall be deemed included in the quoted rate of item. |
| 120 | Supply and fix, in replacement Exhaust fan of size 450 mm, Heavy duty 1200RPM, electrically driven, 240volts, 50Hz, single phase, AC supply, copper wounddynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3\" long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to exhaust fan for giving connectioncomplete all as specified and directed. Note: Making suitable opening for fixing exhaust fan as required shall be deemed included in the quoted rate of item. (Old reteieved item shal be deposited in store yard of AGE EM) |
| 121 | Supply and fix in replacement LED tube light 20 watt, (4\" long), 6500K, wall mounted, E-lite LED curve with high lumen batten with efficacy not less than of 100 lumens, with integrated electronic driver complete with all accessories complete all as specified and directed. |
| 122 | Supply and fixing in replacement 1100 volts grade heavy duty PVC cable insulated aluminium conductor served with inner sheating of PVC tape and over all PVCsheathed in service connection stranded conductor flatr 6 sqmm 2 core cable allas specified and directed.cted and specified |
| 123 | Supply and fixing Iin replacement LED street light fitting powder coated pressure die cast alminium compact High power LED street light with heat resistant toughened glass for 25 watt with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Devicebracket made out of GI Pipe 40mm medium grade 1.2 mtr long made to shape with fixing clamps of MS Flat 40x6mm nuts bolts Complete all as specified and directed. |
| 124 | Supply and fixing in replacement, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor on surface FRLS PVC insulated and unsheathed cable drawn inexisting non metalic PVC rigid conduit medium grade of suitable size with all standared fitting ,including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , complete all as specified and directed.Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cableshall be measured as one unit/ one running meter. |
| 125 | Material and Labourin replacement Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 m distance from earth pit) and testing on completion including necessary excavation and earth work complete all as specified and directed.. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe, funnel, wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the water- ing pipe,bends,elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing notless than 4 Kg/Sqm. |
| 126 | Supply, Install, testing in replacement and commissioning LT Distribution Panel (CPRI approved) cubicle type, Double door, IP-65, Outdoor type, factory fabricated pre-wired made out of 3.15mm thick CRCA MS sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in Loukle construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubical shall have frame work at bottom of MS channel MC 100 fixed to the top of platform.The platform for LT panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400mm below ground level constructed with brick (sub class \"B) work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50cm thick over bricks padestal with adequate opening for entry of cable complete as per manufacturers recommendation & directed by Engineer-in-Charge. A detacheable gland plate of thickness not less than 3mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated, front & back opening type, and fixing 2 Nos danger notice plate to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- |
| 127 | Incoming :-(i) Aluminium TPN bus bar strip of rating 200 Amps fixed on epoxy insulator -04 Nos.(ii) MCCB 4pole 100 A alongwith spreader terminal with adjustable thermal magnetic setting-01 No(iii) Multifunction digital meter to measure voltage, current, KWH, PF,Amp with CT\"s set with suitable size.-01 No(iv)Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 setOutgoing:-(i) MCCB 4pole 63A, A alongwith spreader terminal with adjustable thermal magnetic setting-01 No(ii) MCCB 4pole 40 A, A alongwith spreader terminal with adjustable thermal magnetic setting-01 No(iii) Multifunction digital meter to measure voltage, current, KWH, PF,Amp with CT\"s set with suitable size.-02 Nos(iv) Star delta starter suitable for 3 Phase motor 20 HP capacity with electronic timer , timing range 3 to 60 sec, 415 Volts, AC -01 No including Single phase preventer -01 No, Thermal overload relay, 20 to 32 Amps , 415 Volts with tripping indicator-01 No, Auto level Sensor -01 No and Selector switch -01 Nos(v) Star delta starter suitable for 3 Phase motor 10 HP capacity with electronic timer , timing range 3 to 60 sec, 415 Volts, AC -01 No including Single phase preventer -01 Nos, Thermal overload relay, 10 to 16 Amps , 415 Volts with tripping indicator-01 No, Auto level Sensor -01 No and Selector switch -01 No.Notes: (i) LT panel board shall be type tested from CPRI.(ii) SLD Diagram for LT Panel will be got aproved from GE before placing the order & final diagram will be fixed on the front& rear door.(iii) Rate for above factors shall be deemed to be including in rate quoted(iv) A copy of valid CPRI type test report to be enclosed while obtaining approval of GE.(v) Necessary disconnection from old exiting LT Panel & connection for new LT panels shall be deemed to be including in rate quoted. |
| 128 | Supply, Install, testing in replacement and commissioning LT Distribution Panel (CPRI approved) cubicle type, Double door, IP-65, Outdoor type, factory fabricated pre-wired made out of 3.15mm thick CRCA MS sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in Loukle construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubical shall have frame work at bottom of MS channel MC 100 fixed to the top of platform.The platform for LT panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400mm below ground level constructed with brick (sub class \"B) work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50cm thick over bricks padestal with adequate opening for entry of cable complete as per manufacturers recommendation & directed by Engineer-in-Charge. A detacheable gland plate of thickness not less than 3mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated, front & back opening type, and fixing 2 Nos danger notice plate to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- |
| 129 | Incoming :-(i) Aluminium TPN bus bar strip of rating 200 Amps fixed on epoxy insulator -04 Nos.(ii) MCCB 4pole 63 A alongwith spreader terminal with adjustable thermal magnetic setting-01 No(iii) Multifunction digital meter to measure voltage, current, KWH, PF,Amp with CT\"s set with suitable size.-01 No(iv)Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 setOutgoing:-(i) MCCB 4pole 40 A, alongwith spreader terminal with adjustable thermal magnetic setting-02 Nos(ii)Multifunction digital meter to measure voltage, current, KWH, PF,Amp with CT\"s set with suitable size.-02 Nos(iii) Star delta starter suitable for 3 Phase motor 10 HP capacity with electronic timer , timing range 3 to 60 sec, 415 Volts, AC -02 Nos including Single phase preventer -02 Nos, Thermal overload relay, 10 to 16 Amps , 415 Volts with tripping indicator 10 HP -02 Nos, Auto level sensor -02 Nos and Selector switch -02 NosNotes: (i) LT panel board shall be type tested from CPRI.(ii) SLD Diagram forPanel will be got aproved from GE before placing the order & final diagram will be fixed on the front & rear door.(iii) Rate for above factors shall be deemed to be including in rate quoted(iv) A copy of valid CPRI type test report to be enclosed while obtaining approval of GE.(v) Necessary disconnection from old exiting LT Panel & connection for new LT panels shall be deemed to be including in rate quoted. |
| 130 | Supply, Install, testing in replacement and commissioning LT Distribution Panel (CPRI approved) cubicle type, Double door, IP-65, Outdoor type, factory fabricated pre-wired made out of 3.15mm thick CRCA MS sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in Loukle construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubical shall have frame work at bottom of MS channel MC 100 fixed to the top of platform.The platform for LT panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400mm below ground level constructed with brick (sub class \"B) work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50cm thick over bricks padestal with adequate opening for entry of cable complete as per manufacturers recommendation & directed by Engineer-in-Charge. A detacheable gland plate of thickness not less than 3mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated, front & back opening type, and fixing 2 Nos danger notice plate to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- |
| 131 | Incoming :-(i) Aluminium TPN bus bar strip of rating 200 Amps fixed on epoxy insulator -04 Nos.(ii) MCCB 4pole 160 A alongwith spreader terminal with adjustable thermal magnetic setting-01 No(iii) Multifunction digital meter to measure voltage, current, KWH, PF,Amp with CT\"s set with suitable size.-01 No(iv)Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 setOutgoing:-(i) MCCB 4 pole 100 A, alongwith spreader terminal with adjustable thermal magnetic setting-01 No(ii) MCCB 4 pole 63 A, alongwith spreader terminal with adjustable thermal magnetic setting-01 No(iii) Multifunction digital meter to measure voltage, current, KWH, PF,Amp with CT\"s set with suitable size.-02 Nos(iv) Star delta starter suitable for 3 Phase motor 20 HP capacity with electronic timer , timing range 3 to 60 sec, 415 Volts, AC -02 Nos including Single phase preventer -02 Nos, Thermal overload relay, 10 to 16 Amps , 415 Volts with tripping indicator-01 No, Auto level sensor -02 Nos and Selector switch -02 NosNotes: (i)Manufacturer of LT pannel shall be approved byCPRI.(ii) SLD Diagram for LT Panel will be got aproved from GE before placing the order & final diagram will be fixed on the front & rear door.(iii) Rate for above factors shall be deemed to be including in rate quoted(iv)Necessary disconnection from old exiting LT Panel & connection for new LT panels shall be deemed to be including in rate quoted. |
| 132 | Supply and fixing in replacement of submersible PVC insulated 4 sqmm, 6 core copper cable HR 120 deg C ,1100 volts confirming IS 694:1990, complete all as specified and directed. |
| 133 | Supply and fixing in replacement of submersible PVC insulated 6 sqmm, 6 core copper cable HR 120 deg C ,1100 volts confirming IS 694:1990, complete all as specified and directed. |
| 134 | Supply, laying and testing in replacement Ductile Iron Pressure Pipes with flanged type of 150mm bore class K-9 centrifugally cast conforming to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and including flangedjoints as per required at site, including dismantling & taking out the old unserviceable water supply pipeline any type from the trenches; Complete all as specified .Note:- (a) The DI fittings if any shall be measured and paid separately under relevant items.(b) Excavation & other earth work shall be measured and paid separately under relevant items. |
| 135 | Supply, laying and testing in replacement Ductile Iron Pressure Pipes flanged type of 100mm bore class K-9 centrifugally cast conforming to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and includingflangedjoints as per required at site, including dismantling & taking out the old unserviceable water supply pipe line any type from the trenches; Complete all as specified and as directed.Note:- (a) The DI fittings if anyshall be measured and paid for separately under relevant items.(b) Excavation & other earth work shall be measured and paid separately under relevant items. |
| 136 | Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried verticallyin ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed.Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted.ii) Excavation and earth work in any type of soil shall be deemed to be included in rates. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail