| 1 | Demolition of reinforced cement Concrete of any description and in any position nototherwise specifically provided. (reinforcement cut as required to facilitate demolition) |
| 2 | M&L for dismantling brickwork or stone/ boulder masonry, built in built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 3 | M/L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter Rough finished surface of concrete.(Flat) |
| 4 | M/L for RCC (Reinforced cement concrete) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like M20 & 20mm graded aggregate. |
| 5 | S&F of TMT Bars 10 mm dia and over cut to length,bent to shape required, including cranking bending spirally for hooping for columns, hooking each, binding with and including mild steel wire(annealed) n.less than 0.9mm dia or securing with clips. |
| 6 | M&L for Brick work with sub class \"B\" bricks,straight or curved on plan exc 6.0m mean radius built in cement mortar 1:4. |
| 7 | M&L for applying neat cement slurry&rendering 15mm thick cement plaster 1:4 on wall& surface to be finished even & smooth. |
| 8 | M&L Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, Brushing neat cement slurry with 3.0kg of cement per sq. metre &rendering 20 mm thick cement plaster 1:4 on wall& surface to be finished even & smooth (without using extra lime or cement). |
| 9 | M&L taking down loose ceiling cement plaster including raking out joint hacking ,scrubbing down with water, Dubbing out average 10mm thick on irregular face of walls (when specifically ordered in writing) In 1:6 cement plaster.brushing neat cement slurry with 3.0 kg of cement per Sq.m & Rendering 15mm thick on fair faces of brick work or concrete surfaces of 1:3 cement mortar in ceiling.rendering is to be finished even and smooth (without using extra lime or cement. |
| 10 | M&L for preparation of surface of new plastered wall and Chalk whiting, on plastered surfaces, preparatory to distempering etc. |
| 11 | M&L for 3mm thick wall care putty on wall (Make: asian, JK,Birla) |
| 12 | M&L for preparing the new surfaces, apply plasticemulsion two coat Surfaces of any description over 10cm girth or width, not otherwise described (Asian paints/ Nerolac, Berger) as approved by EIC in exterior grades. |
| 13 | M&L for preparing old surfaces of steel apply two coats of syntheticenamel paint (ordinary/ tint), not otherwise descri-bed, over 10cm width or girth on steel based surface.Make: (Apcolite of Asian paints, Dulux Gloss of ICI Paints, Goodlass of Nerolac) Shade as approved by EIC at the time of execution. |
| 14 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, Brushing neat cement slurry with 3.0kg of cement per sq. metre and Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes (1:4). |
| 15 | Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3. |
| 16 | M&L for cement concreteType B, 1:2:4( M15), 12.5mm graded aggregate. |
| 17 | Labour charges for fixing framed work such as grills, gratings etc with ends of bars souldered and/or riveted or forgedinto spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk way, railings, framework of water tankand similar work confirming to Fe.290.Gde-E-165 |
| 18 | Removing building materials etc. to a distance of 5 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination.(0.62 cum =One load) |
| 19 | Taking down old tarfelt & cleaning the bitinumen surface by wire brushing, washing down & disposing the pealed off tarfelt muck, removing grass, small trees with uprooting etc. from roof. |
| 20 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of acoat of bitumen primer for bitumen membrane @ 0.40 litre/sqm of the same manufactures as membrane of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer ofmembrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through theauthorised applicator of the manufacturer of membrane Make- STP,IWL,TATA. |