| 1 | Name of Work: Pradhanmantri Awas Yojna ke Antargat Gram Karari me Nirmit 756 Awason wa Overhead Tank Banaye jane ka Nirman Karya.Note :-(1)- GST Excluded on the aforesaid work. |
| 2 | R.C.C Overhead Tank- Supply of all material labour T&P etc.for complete construction of R.C.C Over head tank of following capacity and stagiing above ground level with main components incluiding cost of soil testing and assuming bearing capacity of soil as 8 MT with supply of design and drawings.All the water retaining components of OHT shall be casted in M-30 concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement coarse sand and stone grit as per I.S 11682 and I.S 456 seismic effects and wind load should be taken into consideration as per I.S 1893 for earthquake resistance and I.S 875 part-III for wind load on structure and incluiding 1M wide RCC staircase 1m wide R.C.C M30 balcony M.S.ladder made of 50x50x6 mm angles section and 20 mm plain M.S bars with hand rails of 20mm medium class G.I p[ipes one aluminium ladder inside the tak from top dome R.C.C. railing with 20mm dia medium class G.I.(in 3 rows) on both sides of stair case supported on 50x50x6mm M.S angle section spaced at intervals not more than 1.5m proper ventilator at top dome in circular shape of 1.2 m dia water level indicator fabricated with sensor connecting to automation lightening conductor as per I.S.S.2309 or its latest amendment of latest electricity rules consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966 C.I. manhole of min 60x60 cm size with locking arrangement supply fixing jointing D.I.D/F pipes of appropriate size with D.D/F special conforming to IS 8329/2000 as vertical pipes for inlet,outlet,overflow and waashout as per latest / relevant I.S specification with all jointing material for proper completion of work,Construction of bed blocks in 1:2:3 PCC with cement ,coarse sand and approved stone grit ,construction of washout / overflow chamber for sluice /butter fly valves as per departmental drawing supply of 200 mm dia PVC pipes as per I.S.- 4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water compound paintings of all concrete surface and steel pipe works with three coats of approved cement and anticorrosive paints.500 KL 14 M Staging (JAL NIGAM SOR.30.00+30.21) |
| 3 | add for 6m staging |
| 4 | Sluice valve - 125 mm dia for washout and overflow(JLN SOR.34.05) |
| 5 | Scour valve 150 mm dia (JLN SOR.34.10) |
| 6 | Pressure release valve 80mm dia (JLN SOR.35.01) |
| 7 | Supply and installation testing of single/doble ball type air valve conforming to latest/relevant I.S. (150 mm dia) (JLN SOR.36.04) |
| 8 | Supply of following sizes (D.I) pipes for rising main distribution system conforming to latest/relevant I.S. 8329/2000 specification with all jointing materials such bas specials conforming to latest /relevant I.S specification,suitable for D.I pipes as per I.S-239/2000 AND IS 8329/2000 or their latest amendment incluiding F.O.R destination and all taxes and insurance etc.with loading ,unloading and careting up to site of work, also incluiding testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches and laying true to alignment and gradient and jointing etc.complete (incluiding testintg of pipes for making up the length but excluiding the cost of trenches).all complete as per instruction of Engineer-in-charge. 125mm dia DI K9 Pipe (JAL NIGAM SOR.32.05) |
| 9 | Provide all material,labour ,T&P etc complete and constructed Bye-pass chamber for pump house (100(L)x1000(W)x1150(H)mm drawing (drawing no. D-3) and as per the specification for civil works given in the bid document,incluiding supply of all materials,labour and T&P etc,complete as per instruction of Engineer -in charge. (JAL NIGAM SOR.29.00) |
| 10 | Sluice valve chamber (masonry Type) - dia upto 200 mm ‐ 1000 (L) x 1200 (W) x 1300 (H) mm (JAL NIGAM SOR.38.01) |
| 11 | Provide all material labour T&P etc,complete and construct pump house size (3.6x3.0x3.0)m Chlorinating room size (2.5x1.8x3.0)m as per departmental type design and drawing (drawing no.D-2) and per the specification for civil work given in the bid document incluiding supply of all material labour and T&P etc complete as per instruction of Engineer-in-charge(JAL NIGAM SOR.27.00). (JAL NIGAM SOR.27.00) |
| 12 | DC/RC Drilling incluiding Hiring Transportation,Erection,Dismantling with loading and unloading of rig and assosiated T&P complete in all respect incluiding required all material labour & T&P etc. DC/RC Drilling up to 100 Mtr. Tube well construction - 600 MMØ (JLN.2.04) |
| 13 | DC/RC Drilling incluiding Hiring Transportation,Erection,Dismantling with loading and unloading of rig and assosiated T&P complete in all respect incluiding required all material labour & T&P etc. DC/RC Drilling up to 100 Mtr. Tube well construction - 500 MMØ (JLN.2.03) |
| 14 | DC/RC Drilling incluiding Hiring Transportation,Erection,Dismantling with loading and unloading of rig and assosiated T&P complete in all respect incluiding required all material labour & T&P etc DC/RC Drilling from 101 Mtr. To 200 Mtr.Deep 500 MMØ (JLN.2.07) |
| 15 | Tube Well Assembly MSERW plain pipe as per IS 4270(A) 100 MMØ (JLN.3.01) |
| 16 | (B) 150 MMØ (JLN.3.02) |
| 17 | (C) 300 MMØ (JLN.3.04) |
| 18 | MSERW Pipe slotted pipe as per IS 8110- 150 MMØ (JLN.3.06) |
| 19 | 150 MMØ MS. Ring made by 150 mm x 12 mm flat (JLN.3.10) |
| 20 | 300 MMØ MS. Ring made by 175 mm x 16 mm flat (JLN.3.12) |
| 21 | MS Bail Plug As pee IS 2800 150 MMØ M.S.Bail Plug (JLN.3.14) |
| 22 | 300 x 150 mm reducer (JLN.3.19) |
| 23 | MSSI Clamp-As per IS 2800 -300 MMØ M.S.S..I Clamp (JLN.3.25) |
| 24 | 300 MMØ tubewell assembly support (JLN.3.29) |
| 25 | MS Well Cap 300 MMØ (JLN.3.33) |
| 26 | Centre guide 150 MMØ TW assembly (JLN.3.34) |
| 27 | Lowering of above assembly with welding of parts complete in all respect with all required material, T&P, labour, etc Lowering up to 100 Mtr. Deep (JA NIGAM SOR.4.00)(A) 150 MMØ MSERW Plane/Slotted Pipe (JLN.4.02) |
| 28 | 300 MMØ MSERW Plane/Slotted Pipe (JLN.4.04) |
| 29 | Lowering of above assembly with welding of parts complete in all respect with all required material, T&P, labour, etc Lowering from 101 Mtr. To 200 Mtr. Deep 150 MMØ MSERW Plane/Slotted Pipe (JLN.4.06) |
| 30 | Supplying and unconsolidated packing of gravel with suitable size (JAL NIGAM SOR.5.0) |
| 31 | Charges of Development of Tube well incluiding transportation dismantling of compressor (JAL NIGAM SOR.6.0)(A) Charges for Development by 250 PSI Compressor per hour (JLN.6.02) |
| 32 | Charges for Development of TW by 1 cusec OP Unit (JLN.6.06) |
| 33 | SITC of energy AC submersible pumping plant incluiding soft starter with submersible flat cable of suitable length ,main piping & vlaves with 8 nos column pipe jointer power wiring chemical earthing ,painting ,wiring of pump house (internal & external) and installation job of pumping plant complete in all respect with all required material,T&P labour etc for following duties in Grid Powered Application. 15 HP (150 mm Dia size Main pipping and valves) (JAL NIGAM SOR.8.0+ 8.04) |
| 34 | Pressure Transmitter (JAL NIGAM SOR.9.0) |
| 35 | Check Valve PN 1.0 DPCV dia 100 mm |
| 36 | Electrically operatedD.I Sluice Valve Metal PN 1.0 dia 100 mm (JAL NIGAM SOR.10.01) |
| 37 | Logging of Borehole by Electric logging (JAL NIGAM SOR.4.17) |
| 38 | Dismantling Joint PN 1.0 dia 100 |
| 39 | CE/UL Certified Electromagnetic flow meters 100 mm (JAL NIGAM SOR.51.02) |
| 40 | Radar type Level transmitter (JAL NIGAM SOR.52.0) |
| 41 | Providing and installation hydrostatic level sensor at all tubewell pumping system including all accessories etc. complete in all respect as per instructions of Engineer ‐in –charge (JAL NIGAM SOR.11.0) |
| 42 | Electronic type chlorinating dosing system (1W+1S) with LPH capacity 4kg/cm2 working pressure with 200 litres tank valves pipes with all required accessories. (JAL NIGAM SOR.13.0) |
| 43 | Turbidity & Chlorine analyzer. |
| 44 | Installation of suitable capacity simple T.W. automation system to control operation of the pumping plant with respect to high/low water level in OHT with RTU panel, 7\" HMI screen, surge device including enrgy meter inside the pump house with arrangement for communication of data with GSM and GPRS system to show required parameters including all accessories etc. complete in all respect as per instructions of Engineer ‐in –charge. (JAL NIGAM SOR.43.0) |
| 45 | Complete cabling for tubewell incluiding all power and controlcables of all equipment at pumphouse and OHT. (JAL NIGAM SOR.53.0) |
| 46 | Control Panel - control panel for all power equipments with I P 54 protection |
| 47 | Air valve chamber(350 (L)x 350 (w)x 500(H) mm (JAL NIGAM SOR.38.04) |
| 48 | Scour valve chamber 1000(L) x 1200 (w) x 1300(H) mm (JAL NIGAM SOR.38.05) |
| 49 | PRV Valve chamber 1000(L) x 1200 (w) x 1300(H) mm (JAL NIGAM SOR.38.06) |
| 50 | Supply of underground sluice valve type fire hydrant consisting of 80 mm dia sluice valve 80 mm dia tail piece 80 mm dia duck foot bend and 80mm dia standard makes iron coupling with cap and etc,complete conforming to latest /relevant I.S. specification incluiding all taxes and insurance up to site of work lowering them into the trenches fixing in position and jointing them with pipelines and testing etc.complete(including as per instruction of Engineer-in-charge. (JAL NIGAM SOR.37.00) |
| 51 | Fire Hydrant chamber (750(L)x450(W)x1000(H) mm. (JAL NIGAM SOR.38.03) |
| 52 | Supply installation testing and commissioning of electric driven terrace pump suitable for automatic operatrion and consisting of following complete in all respects as required:(Terrace pump) (PWD.SOR.(18.04) |
| 53 | As in item no.(251) above but excavation in soil mixed with moorum/shingle/kankar requiring the use of special T&P such as pickaxes ,sabbals etc. SOR.252) |
| 54 | Cement concrete with 4 cm (1.5\") gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T & P etc. required for proper completion of the work. SOR NO. 281 (2022) |
| 55 | RCC work with cement approved coarse sand 2 cm (3/4\") gauge approved stone ballast in the proportion of 1:2:4 in lintels of door and windows excluding supply of reinforcement and its binding but including its fixing in binding the same with 24 B.W.G.G.I binding wire and icluding necessary centering and shuttring etc and also including supply of all materials,labours T&P etc required for proper completion of the workl binding wire cost being included. ) SOR No-283 (2022) |
| 56 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (SOR No-504 2022) Please Enable Macros to View BoQ information |