| 1 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | All as per serial item No. 1.00 here-in-before but depth exceeding 1.5m and not exceeding 3m complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. |
| 4 | Removing excavated soil/material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and as directed. |
| 5 | Supply and fixing steel tubular pole, swaged type, 11 metre long, type 410 SP-55, with mild steel base plate, finial taper plug, bolts, nuts & screws including drilling of necessary holes, with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint over a coat of aluminium red oxide primer to remaining portion of pole and marking pole number in letters & figures of size not less than 8cm height including taking out old unserviceable steel tubular pole complete all as specified and as directed.Note :- (i) Excavation, earthwork, including taking out old pole from foundation and refilling after erection of pole and disposal of soil shall be deemed to be included in the unit rate quoted for this item. (ii) PCC in foundation & coping shall be measured and paid for separately. |
| 6 | Supply and fixing steel tubular pole, swaged type, 9 metre long, type 410 SP-31, with mild steel base plate, finial taper plug, bolts, nuts & screws including drilling of necessary holes, with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint over a coat of aluminium red oxide primer to remaining portion of pole and marking pole number in letters & figures of size not less than 8cm height including taking out old unserviceable steel tubular pole complete all as specified and as directed.Note :- (i) Excavation, earthwork, including taking out old pole from foundation and refilling after erection of pole and disposal of soil shall be deemed to be included in the unit rate quoted for this item. (ii) PCC in foundation & coping shall be measured and paid for separately. |
| 7 | S&F Stay assembly complete with 20mm dia, 2000mm long GI stay rod, with threaded ends and GI nuts, two number thimbles, MS galvanized clamps made out of 40mmx6mm flat iron including MS galvanized nuts, bolts and washers, 300mm x 300mm x 6mm MS galvanized stay plate, stay bow, galvanized stay strand 7/4 mm including shackle insulator and stay clamp, with & including painting of exposed MS work with two coats of aluminium paint over a coat of red oxide zinc chromate primer, all as shown in electrical plate No 1 of MES Schedule Part-I, including taking out old unserviceable stay assembly, complete all as specified and as directed.Note : Excavation & earthwork and PCC shall be measured & paid for separately under respective items of this Schedule. |
| 8 | Dismantling of PCC HT pole of any description complete all as specified and as directed. Note: Excavation and earth work including taking out pole from foundation and refilling after erection and disposal of soil and rubbish shall be deemed to be included in the quoted unit rate for this item and shall not be measured measured separately. |
| 9 | M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations of poles, filling, mass concrete and similar works, complete all as specified and as directed.Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. |
| 10 | M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundations of stay assembly, filling, mass concrete and similar works, complete all as specified and as directed. |
| 11 | Supply and fixing HDPE DWC pipe inner dia 63mm and outer dia 77mm confirming to IS-16205 for 25Sqmm to 70 Sqmm cable protection in trenches complete all as specified and as directed. |
| 12 | Supply and fixing HDPE DWC pipe inner dia103mm and outer dia 120mm confirming to IS-16205 for 95Sqmm to 240 Sqmm cable protection in trenches complete all as specified and as directed. |
| 13 | Supply, laying, jointing and testing HT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium stranded conductor 11000 Volt (Earthed) grade of cross sectional area 95 Sqmm, 3 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc, including dismantling & taking out old unserviceable HT cable, complete all as specified and as directed.Notes :- (i) DWC protection pipe, GI protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 14 | All as per serial item No 13.00 here-in-before but of size 120 Sqmm 3 Core complete all as specified and as directed. |
| 15 | All as per serial item No 13.00 here-in-before but of size 185 Sqmm 3 Core complete all as specified and as directed. |
| 16 | All as per serial item No 13.00 here-in-before but of size 240 Sqmm 3 Core complete all as specified and as directed. |
| 17 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 18 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 19 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 20 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified & as directed. |
| 21 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 22 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 23 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified and as directed. |
| 24 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified and as directed. |
| 25 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified and as directed. |
| 26 | Taking down / taking out old unserviceable burnt / punctured / faulty aluminium / HT 11 KV Pilca cable / XLPE (cross linked polyethylene) cable of size 95 sqmm to 240 sqmm, 3 core laid in trenches/ducts, through pipe, under floors or roads crossing/ Path/ drains/ along poles etc and relaying / refixing the same after rectification of defect including cutting making jointing complete all as specified and as directed.Notes :- (i) Excavation & earth work and cable jointing kit shall be measured & paid for separately.(ii) Old serviceable brick / precast PCC cable cover shall be reused and rates quoted shall deemed to included for the same. |
| 27 | M&L for Boring of holes of road, pavement, hard standing, etc by trench less technology using necessary machine / manually without disturbing the top surface suitable for passing the GI protection pipe / cables, complete all as specified and as directed. |
| 28 | M&L for Galvanized iron tubing, 80mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains/Path/under floor, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cableincluding taking down old unserviceable protection pipe with clamps complete all as specified and as directed.Note :- Excavation & earthwork shall be measured & paid for separately. |
| 29 | M&L for Galvanized iron tubing, 150mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cableincluding taking down old unserviceable protection pipe with clamps complete all as specified and as directed.Note :- Excavation & earthwork shall be measured & paid for separately. |
| 30 | M&L for ascertaining / pin pointing the fault in faulty 11 KV HT cables by using HT cable fault locator machine, removing the fault and testing HT cable at 22 KV complete all as specified and as directed.Note :- Excavation & earth work and cable jointing kit shall be measured & paid for separately. |
| 31 | S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on 11 KV HT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/type/capacity, complete all as specified and as directed.Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv)Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code. |
| 32 | Dismantling of steel tubular HT pole of any description complete all as specified and as directed. Note: Excavation and earth work including taking out pole from foundation and refilling after erection and disposal of soil and rubbish shall be deemed to be included in the quoted unit rate for this item and shall not be measured measured separately. |
| 33 | S&F in replacement of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts, in any shape or size for 11 KV over head structure with & including two coats of aluminium paint over a coat of red oxide zinc chrome primer, complete all as specified and as directed. Notes :-(i) Size, section and shape of steel sections shall be as directed. (ii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect. |
| 34 | S&F Switch air break, gang operated outdoor, Vertical operatedtype, HT 11 KV, Triple pole, 200 Amps, 3 insulator per phase, rotating vertical type, with fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 25mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for vertical mounting, fixed in repairs, complete all as specified and as directed. |
| 35 | S&F Switch air break, gang operated outdoor, Horizontal operatedtype, HT 11 KV, Triple pole, 400 Amps, 3 insulator per phase, tilting/rocking horizontal type, with fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 25mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontal mounting, fixed in repairs, complete all as specified and as directed. |
| 36 | S&F Drop out expulsion fuse assembly with fuse carrier, triple pole, HT 11000 Volts, 200 Amps, outdoor type (having two Nos post insulator mounted on MS channel for each pole) and jumpers with conductors line taps, clamps, colour coated HT sleeves and fitting, fixed in repairs, complete all as specified and as directed. |
| 37 | Repair to existing switch air break, gang operated outdoor, vertical / horizontal mechanically operatedtype, HT 11 KV, 200 to 400 Amp, Triple pole by cleaning of moving / static contacts with tetrachloride solution, scrapping and making smooth to existing spot points of the contacts by emery paper, providing grease on moving contacts, mechanical torque joint, tightening of canopy with drop out fuse assembly set (three contacts in each GOD switch) to make the GOD switch fully & smoothly functional, complete all as specified and as directed. |
| 38 | S&F in replacement of GOD switch insulator, HT 11 KV, Post type insulator conforming to IS, fixed, complete all as specified and as directed. |
| 39 | S&F in replacement of copper Male contact jaw suitable for 200/400 Amps capacity vertical / horizontal operated GOD switch 11 KV, fixed, complete all as specified and as directed. |
| 40 | S&F in replacement of copper Female contact with all necessary fittings suitable for 200/400 Amps capacity vertical / horizontal operated 11 KV GOD switch, fixed, complete all as specified and as directed. |
| 41 | S&F in replacement of 11 KV Jumper with rabbit conductor with proper cramping of aluminium lug of appropriate size and fixing with PG clamp to 11 KV bus and fixing to GOD with proper nut, bolts, washer arrangement complete all as specified and as directed. |
| 42 | S&F Lightning arresters HT 11 KV 65 kilo Amp Non linear expulsion type transmission class with standard fittings confirming to IS-3070 (Part-I) 1985, fixed in repairs, complete all as specified and as directed. |
| 43 | S&F galvanized mild steel Disc insulator (Tongue and Clevis type) strain hardware fitting with three bolted tension clamp and one cross arm clamp suitable for ACSR Rabbit conductor of 11 KV over head line, fixed in repairs, complete all as specified and as directed. |
| 44 | S&F in replacement of PG Clamp for ACSR Dog conductor, fixed, complete all as specified and as directed. |
| 45 | S&F in replacement of PG Clamp for ACSR Rabbit conductor, fixed, complete all as specified and as directed. |
| 46 | S&F Pin type insulator, porcelain, vitreous, white, brown or green for working pressure 11000 Volts, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, including dismantling & taking down old unserviceable insulator, complete all as specified and as directed. |
| 47 | S&F Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 90mm x 140 mm and clearance hole 25.5 mm, including dismantling & taking down old unserviceable insulator, complete all as specified and as directed. |
| 48 | S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified and as directed. |
| 49 | M&L for Galvanized iron strip 32mm x 6mm buried in ground, including drilling, bending, nuts, bolts and washers, fixed in repairs, complete all as specified and as directed.Note : Excavation & earthwork shall be measured & paid for separately under respective items of this Schedule. |
| 50 | M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized iron earth wire 4mm dia as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and other end of earth wire connected to transformer / GOD / Panel / equipment body / test point, GI earth wire encased in and including 15mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. |
| 51 | M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing.Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. |
| 52 | M&L for 40mm graded crushed stone aggregate, deposited, spread and leveled in layers not exc 15 cm thick, rammed to a true surface, under 2/4 pole structure and around the 2/4 pole structure & outdoor electrical installations, complete all as specified and as directed. |
| 53 | Tightening of existing loose stay wire of stay assembly with suitable tension including providing nuts, bolts, washers and repair to other wire, un-winded stay wire etc, complete all as specified and as directed |
| 54 | S&F Danger notice plate of size 25cm x 20cm x 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour for HT 11000 Volts and fixed with suitable MS clamps made out of flat iron 25x3mm, bolts and nuts of approved size, fixed in repairs, complete all as specified and as directed. |
| 55 | Re-straining/re-stringing/tightening of existing HT 11 KV over head Aluminium Conductor Steel Reinforced (ACSR) and GI earth wire of any size/type upto permissible sag in between existing span carefully without damaging other components such as insulators etc of HT distribution system with & including repair to broken conductor where required and replacement of binding wire with new 2mm dia aluminium binding wire complete all as specified and as directed. Note :- Unit for measurement and payment for this item “Each span” is comprising of 3 Nos ACSR conductors and one GI earth wire between two adjacent poles in line. |
| 56 | Re-straining/re-stringing/tightening of existing over head GI earth continuous wire of any size with/without hangers on HT Poles in between existing span carefully without damaging other components such as insulators etc of HT distribution system with & including replacement of GI binding wire of suitable size complete all as specified and as directed. Note :- Unit for measurement and payment for this item “Each span” is comprising of one GI earth wire between two adjacent poles in line. |
| 57 | Cutting/trimming/pruning of tree branches coming across electric power head lines HT 11 KV feeder, cleaning the span and making the feeder free from 3 metre clearance alround from the external conductors and removing cut tree branches from road and the same from site and depositing at places more than 500 metre the cantt area complete all as directed.Note :Unit for measurement and payment for this item is “Each span” irrespective of number of conductors in over head line. |
| 58 | M&L for painting to PCC HT pole 11 / 12 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.50 metre height from top of PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height including preparation of old surfaces for painting complete all as specified and as directed. |
| 59 | M&L for painting to Steel tubular pole for streel light feeder / steel tubular HT pole 11/12 metre long upto the top surface of pole with two coats of aluminium anti corrosive paint of first quality and two coats of synthetic enamel paint in alternate black and yellow strips 30cm each upto 1.50 metre height from top of PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height including preparation of old surfaces for painting complete all as specified & as directed. |
| 60 | Surface dressing not exc 15cm deep in soft/loose soil and clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) surrounding Transformers, LT Panels, 02 Pole structures, 04 Pole Structures, 11 KV structure etc at various sub stations / E&M installations and removing rubbish upto a distance exc 200m & not exc 250m outside the periphery of the area under clearance complete all as specified and as directed. |
| 61 | M&L for cable route indicator made of Jodhpur stone of finished size 90cm x 20cm x 8cm with round top and all finished surfaces duly marked with ‘HT’ lettering of size 6cm x 6cm engraved on two sides of the stone and letters painted with thick synthetic enamel paint of red colour complete all as specified and as directed.Notes :(i) These shall be fixed along the route of cable at 30 meter interval & on every turning & cable joint as directed. (ii) PCC and earth work for fixing cable route indicator shall be measured & paid for separately under respective items of this Schedule. |