| 1 | Mannual Rescue and Operation Rescue of water supply installation with all connected equipments, electric driven pump set, 10,000 Gph, supply lines and machineries (as listed herein under) and internal and external electrification, external water supply system, sumps, overhead reservoirs, service tanks, etc with one operator / technicianoperation for 02 shifts/per day, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge.Location: Thane(a) Pumping set centrifugal type of capacity 12 litres/sec with 38 m head with electrically driven induction motor 15HP, 3 phase- 02 No. (b) Chemical dozing plant with injection assembly booster pump with induction motor of 1.5HP, 3 phase - 01 No. (c) Vertical type pressure filter of capacity 1000 glns/hr including blower unit with induction motor 5HP, 3 phase - 01No (d) LT electric control panel with all accessories and components - 02 NosNote : (a) In case any operator is missing or absent from duty, a penalty of Rs 650/- per shift shall be recovered from any of dues of the contractor and the Engr-in-Charge decision shall be final and binding on this account.(b)The operator shall keep the paints, machineries and valve chamber surrounding area clean and tidy.(c) Contractor shall provide uniform and necessary tools required by the men employed by him.(d) Contractor shall submit the details of payments and wages for staffs employed through Aadhar link bank account Nos for payment purpose.(e) Painting of the equipments of pumps as required and existing to be done once in a year as per the directions given by the Engineer in Charge. |
| 2 | Mannual Rescue and Operation Rescue for following installations,with all connected equipments and machinaries as detailed here in under with one operator/mechanic,operation in 03 Shifts,including sundays and holidays including routine maintenance checks,tests etc. and upkeeping the installation complete all as specified and directed. Location :- HQ 31 WEU Thane . (i) ist shift-0600 to 1400 hrs (ii) 1400 Hrs to 2200 Hrs (iii) 2200 to 0600 hrs The details of operation of installations comprising the following items/Machinery/Fittings:- (i) Operating DG Set 250 KVA-01 Nos (ii) Operating DG Set 320 KVA - 01 Nos (iii) Operating DG Set 200 KVA-01 Nos(iv) Operating DG Set 125 KVA - 01 Nos Note : (a) In case any operator is missing or absent from duty, a penalty of Rs 650/- per shift shall be recovered from any of dues of the contractor and the Engr-in-Charge decision shall be final and binding on this account.(b)The operator shall keep the paints, machineries and valve chamber surrounding area clean and tidy.(c) Contractor shall provide uniform and necessary tools required by the men employed by him.(d) Contractor shall submit the details of payments and wages for staffs employed through Aadhar link bank account Nos for payment purpose.(e) Painting of the equipments of pumps as required and existing to be done once in a year as per the directions given by the Engineer in Charge. |
| 3 | Manual Rescue and operation Rescue of water supply installation with all connected equipments, electric driven pump set, 20,000 Gph, supply lines and machineries (as listed herein under) and internal and external electrification, external water supply system, sumps, overhead reservoirs, service tanks, etc with one operator / technicianoperation for (01 No/Shift) for 02 shifts, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge.Location : Mahul(i)1stshift-0600 hrs to 1400 hrs(ii)2nd shift - 1400 hrs to 2200 hrsMachineries:(a) Pumping set 25HP - 02No. (b) Pumping set 20HP - 02No. (c) Pumping set 5HP - 02Nos. (d) Electric control panel - 02No Note: - Anymalfunctioning noticed duringthe entire contract period on account of negligence of the operaters , the cost of Repair /replacement of defective parts shall be recoveredfrom any dues from the contractor. Decision of the Eng - in Charge on this subject shall be final and binding |
| 4 | M & L in replacement of PVC Service Water Tank including tank nipple, bends, sockets complete all fitting required at site all including taking down the existing tanks as specified and directed by Engineer-in-Charge of 500 Ltrs capacity. |
| 5 | -Ditto- all as per item No 4.01 above but 1000 Ltrs capacity. |
| 6 | -Ditto- all as per item No 4.02 above but 2000 Ltrs capacity. |
| 7 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in hard/dense soil for laying of under ground cable all as specified and directed by the engineer-in-charge. |
| 8 | Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms all as specified and directed by the engineer-in-charge. |
| 9 | Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point all as specified and directed by the engineer-in-charge. |
| 10 | Taking up or down steel water tubing of upto 50 mm bore and connections including cleaning and setting a side for refixing, etc complete all as specified and directed by the engineer-in-charge. |
| 11 | Supplying, laying, connecting and testing of GI tubing med gde of 25 mm dia with and including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions,etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge. |
| 12 | -Ditto- all as per item No 9.00 above but 40 mm dia. |
| 13 | -Ditto- all as per item No 9.00 above but 50 mm dia. |
| 14 | -Ditto- all as per item No 9.00 above but 80 mm dia. |
| 15 | -Ditto- all as per item No 9.00 above but 100 mm dia. |
| 16 | M & L for servicing ofCentrifugal pump setof capacity 25 HP by opening end covers, greasing the bearings, replacing worn out nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush and painting one coat ofsynthetic enamel paint, including writing/marking in 1\" size letters SM & MES No. for the following capacity of pumps:- |
| 17 | All as per Item No 10.00 above but Pump set 20 HP |
| 18 | All as per Item No 10.00 above but Pump set 15 HP |
| 19 | All as per Item No 10.00 above butPump set 10 HP |
| 20 | All as per Item No 10.00 above but Pump set 5HP |
| 21 | Supply and fix in replacement of old unserviceable Cast iron tank coverwith MS strip /flat iron framework with all necessary fixing and locking arrangement nuts,bolts all as per BMC standards any required alteration to the tank for fixing ofnew CI covers all as specified and directed by the Engineer -in-Chief ofsizes:- 508mm dia. (weight of tank cover not less than 12 Kgs) |
| 22 | M&L for rewinding of electric motor 3 phase 50 Hz 415 volt for 25 HP capacity complete all as directed and specified.(a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc.,(b) Transporting electric motor including loading/ unloading upto wksp and back to site.(c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing onload. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA. (e) Replacement of winding terminal plate with brass stus,/nut, bolt washer.NOTE: Quoted rates shall be deemed to include one year warranty formotors after rewinding and commissioning. |
| 23 | All as per Item No 12.00 For Motor 20 HP Cap |
| 24 | All as per Item No 12.00 For Motor 15 HP Cap |
| 25 | All as per Item No 12.00 For Motor 10 HP Cap |
| 26 | All as per item No 12.00 for Motor 7.5/5 HP capNOTE: Quoted rates shall be deemed to include one year warranty formotors after rewinding and commissioning. |
| 27 | S&F the following component in existing LT PanelBoards including disconnecting and taking down at different locations all as directed :-Voltmeter Digital type ,0-500 Volts of size 96x96mm. |
| 28 | All as per item No 13.00 but Ammeter Digital type of 400 amps capacity of size96X96mm. |
| 29 | Selector switch for voltmeter / Ammeter. |
| 30 | Phase indicating lamp neon type complete with holder assy RYB |
| 31 | CT coils any capacity. |
| 32 | Supply and adding Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containerscomplete all as specified and as directed.Brands having pan india availability, acceptability& being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. Note-: The chemical shall be brought in three lot and period to be procured only before previous batch completed. |
| 33 | Drilling and taping cast iron water mains (in position) for branch connections 15 mm bore of the internal dia. |
| 34 | -Ditto- all as per item No 18.00 above but 20mm bore |
| 35 | Taking up or down steel water tubing 15 mm bore and connections includingcleaning for re-fixing or removal. |
| 36 | -Ditto- all as per item No 19.00 above but 20mm bore |
| 37 | -Ditto- all as per item No 19.00 above but 25mm bore |
| 38 | -Ditto- all as per item No 19.00 above but 40mm bore |
| 39 | -Ditto- all as per item No 19.00 above but 50mm bore |
| 40 | M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting (if required) from any position / location as listed hereinunder and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete al as specified and as directed by the Engineer-In-Charge.(a) Induction motors 25 HP/20 HP - 06 Nos.(b) Electric motors 10/7.5 HP - 03 No.(c) Sluice valve 100 mm dia. - 06 Nos.(d) Sluice valve 80 mm dia. - 06 Nos.(e) Electric Panel Board - 04 Nos |
| 41 | M&L for cleaning of over head reservoir of 20000 gal capacity by draining out water removing sludge, alge-fungi growth from walls/floor, roof by rubbing with wire brush and disinfecting the reservoir with bleaching powder, draining out and making reservoir totally clean all as specified and directed. |
| 42 | M & L for cleaning RCC/PVC Service Tanks upto 500 Itr capacity by draining out entire water, removing sludge, mud etc, cleaning the ceilings from spider webs, mud accumulations etc., with water jets etc., brushing/rubbing with wire/nylon brush/mop to remove all algae /fungal growth and moss etc. entirely from walls, floors, etc. washing clean with fresh water by using water jets and then again washing and treating with anti-bacterial agents, disinfectants and bleaching powder, as required at site and writing in paint of approved font of size \"Date of Cleaning\" and \"Capacity of sumps cleaning off the surrounding complete all as specified and directed by the Engineer-in-charge following capacities: |
| 43 | All as per item No 22.00 above but 501 Ltrs to 1,000 Ltrs pacity |
| 44 | All as per item No 22.00 above but 1001 Ltr to 2.000 Ltrs capacity |
| 45 | All as per item No 22.00 above but 2001 Ltrs to 5,000 Ltrs capacity. |
| 46 | Supply, fabrication, and installation of a stainless steel display board measuring 4 x 3ft, made from high-quality 304/316 stainless steel with a polished or brushed finish The Each board will be securely mounted on two poles, complete with RCC foundation to ensure stability and durability. All necessary foxing accessories, hardware, and installation works are included. The display surface may be engraved, printed, or etched as per requirement. Installation will be carried out with proper leveling, alignment, and finishing complete all as specified and as directed. Location: TS Mahul |
| 47 | Supply, install, in repair! renewal of Residential Silencer of approved make, suitable for 625 KVA DG set, complete with MS Class-B exhaust piping system comprising flanges. Each bellows, and all required fixing accessories and hardware. The work shall include dismantling and removal of the existing silencer, fabrication and erection of associated exhaust piping with proper supports, vibration isolators, gaskets, nuts, bolts, clamps, welding, and alignment. Exhaust pipes shall be insulated with 75 mm thick Mineral Wool (density 50 kg/m\"), wrapped in chicken mesh, and clad with 26-gauge aluminium sheet, including provision of all MS epoxy-painted structural supports. The scope shall further include testing for leakage, application of one coat of primer with two coats of anti-corrosive paint on all fabricated parts, DG set and commissioning the complete exhaust system in fully functional condition, all as directed by the Engineer-in-Charge Location: TS Mahul |
| 48 | S & F foot valve of 150 mm bore, in cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge. |
| 49 | M&L for dismantling existing unserviceable sluice valve and supply and fix new sluice valve ISI marked IS-14846 PN 1.6 with iron operating wheel, flanged type rubber gasket, nut, bolts, washers, including any addition alteration. Fixing of new sluice valve of size 100 mm bore. |
| 50 | All as per item No 26.00 above but of 80 mm bore. |
| 51 | M & L for valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including dosmantling the existing valve chambercomplete all as specified and directed by EIC. |
| 52 | Supply, lay/fix, connect and testing steel water tubing, 25 MM medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to wall/ceiling or laid in trenches/floors including taking up/down existy tubinging and connections complete all as specified and directed by the Engineer-in-Charge. |
| 53 | All as per item No 28.00 above but of 40 mm bore. |
| 54 | All as per item No 28.00 above but of 50 mm bore. |
| 55 | All as per item No 28.00 above but of 80mm bore. |
| 56 | All as per item No 28.00 above but of 100mm bore. |
| 57 | Supply, lay/fix, connect and testing UPVC water tubing, 25 MM,with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked and fixed to wall/ceiling or laid in trenches/floors including taking up/down existing tubinging and connections complete all as specified and directed by the Engineer-in-Charge. |
| 58 | S&F in repairs GM gate valve ISI marked IS-778 screwed down for iron pipeof size 50mm.Make;- Leader/Neeta/ Guru including any addition/alteration and fittings like union, check nut etc |
| 59 | All as per item No. 30.00 above but of size 40mm dia. |
| 60 | All as per item No. 30.00 above but of size 25mm dia. |
| 61 | Excavation in trenches not exc 1.5M wide /n.exc 10 Sqm on plan and not exc 1.5M in depth for laying GI pipe etc and getting out in soft soil. |
| 62 | Returning, filling, including spreading leveling, watering and well ramming in layers not exc 25cm in soil. |
| 63 | Removing excavated Soill not exc 50Mand depositing where directed at a level not exc 1.5M above the starting point all as specified & directed. |
| 64 | M&L for cement concrete in foundation, filling and mass concrete (1:4:8) type D2 using 40mm graded stone aggregate |
| 65 | Replacement of unserviceable ball (float) valve , supply and fix new brass ball valves 25 mm bore, high pressure with polythene float and fly nutscomplete screwed to iron/ GI pipe or brass ferrule including necessary CI fitting such as nipple check nut, reducer elbow sockets etc as required for the following size. |
| 66 | All as per item No 35.00 but 40 mm bore |
| 67 | All as per item No 35.00 but 50 mm bore |