| 1 | Excavation in trenches not exc 1.5 metres wide and not exc1.5 metres deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required level all as specified and as directed by Engineer-in-Charge |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick all as specified and directed by Eng. In Charge |
| 3 | Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point as directed by Engr-in-Charge. |
| 4 | Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines includingPCC (1:2:4) type B-2(with 40 mm graded aggregate) in foundations,filling and mass concrete complete including making good the existing surface complete all as specified and directed. |
| 5 | Supply, layingjointing, testingDIpipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenchesincluding providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ.Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.Note3:- DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV\"s, MTC & e-way bill will produced by contractor during payment of 1st RAR as material laying at site.Note4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.Note5:- Layout plan for laying of DI pipe shall be given by EIC in writing.Note6 :- Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates.) |
| 6 | 100 mm bore |
| 7 | 150 mmbore |
| 8 | Material and labour for Cast iron bends, tapers any type any radius and angle, Tee pieces single branch `Y\" junction, double branch, cross (both all sockets or socket and spigot or flanged) collars, cast Iron connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia borecomplete all as specified and directed by Engineer-in-Charge. |
| 9 | Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y\" junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 150 mm dia bore complete as specified and directed by Engineer-in-Charge. |
| 10 | Material and labour for Rubber Gasket Joint (Tyton Joint) including jointingmaterial for DI/CI pipe of following size/bore :- |
| 11 | 100mm bore |
| 12 | 150mmbore |
| 13 | Supply and fixing dia of neck 11 to 15 mm Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cm long but n. exc 10 cm long complete all as specified and directed |
| 14 | Supply, Laying, Jointing, Welding, Testing and Commisioning of MS Pipe (Heavy Class \"C\") as per IS:1239 of following size laid in trenches or in Horizontal/Vertical/Inclined position or laying in floors for connection of suction/delivery line including taking out the old unserviceable pipes complete all as specified and as directed. (Notes : MS Flanges and Fabrication work shall be measured and paid separately.) |
| 15 | 80 mm bore |
| 16 | 100 mm bore |
| 17 | 150 mm bore |
| 18 | 200 mm bore |
| 19 | Supply& Fixing in replacement MS Flange of following sizes, 16 mm thick, duly welded on ends of MS pipe including necessary cutting to existing MS pipe or in new MS pipe with flange joint including nuts, bolts, washers and rubber gaskets complete all as specified and as directed . |
| 20 | 80 mm bore |
| 21 | 100 mm bore |
| 22 | 150 mm bore |
| 23 | 200 mm bore |
| 24 | M&L for making hole of size 200/150/100 mm with the help of gas cutter and electric driver cutterin MS pipe of size 200 to 450 mm for connection the Pipe line of size 200/150/100 mm bore. |
| 25 | Taking down cement plaster or cement lime plaster on PCC/Stonesurface/brick surfaces including raking out joints hacking for keyscrubbing down with water etc all as directed . |
| 26 | Rendering 15 mm thick in CM (1:4) on fair faces of brickwork or concrete surfacesfinished even & smooth. |
| 27 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc. |
| 28 | M&L Brick work with sub class \"B\" old size bricks bricks straight or cured on plan exceeding 6 m mean radius built in cement mortar 1:6 |
| 29 | Demolition and dismantling concrete in ground floors and pavings n exc 15 cm thickness below or above ground level. |
| 30 | M & L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed |
| 31 | Hacking out old broken glass any thickness, size, quality or description from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads including S&F 3 mm thick plain sheet glass ordinary quality in square not exceeding 0.5 complete all as specified and as directed |
| 32 | M&L for coloured Glazed ceramic tiles in vertical surfaces of size 300mm x 200mm,7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed |
| 33 | Supply and fixing &installation in replacement ofperforated MS cable tray of size 350x50x2mm including horizontal and vertical bends, prepared hanging systemand other accessories including painting of cable tray ofcomplete all as specified and as directed |
| 34 | M&L for fabrication(welding work ) of MS Header/ any size upto 300mmMS pipeat various pump house site for connection of pipe , arresting leakges on header complete all as specified and as directed |
| 35 | M&L Machine pressed precast concrete coloured paver block rubberised moulded interlocking paverblocks any shape and size in replacement confirming to IS 15658-2006 of 60 mm thick, M-35 Grade with grey cement and pigments, over 40 mm & including thick sand cushioning complete all as specified and as directed. |
| 36 | M&L for spread fine river sand in trenches complete all as specified and as directed. |
| 37 | M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and as directed |
| 38 | Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 500 ltrs capacity, trippple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified an as directed. Note: For Pump Priming purpose in pump house. |
| 39 | Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 1000 ltrs capacity, trippple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified an as directed.Note: For Pump Priming purpose in pump house. |
| 40 | Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 2000 ltrs capacity, trippple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified an as directed. Note: For Pump Priming purpose in pump house. |
| 41 | M & L in replacement ofProviding and filling post/framework of stainless steel, grade 304 pipes including braces of stainless steel, plates, angle, flats, tubular sections etc including cutting, hoisting fixing with argon welding, bright finish, buffing polishing etc complete with necessary holes, nuts, bolts, caps and anchor plates of stainless steel as per design provided by Engineer-in-Charge |
| 42 | Manufacturing, supplying and installationin replacement offull cube poly carbonate micro prismatic type retro reflective boards conforming to XI of ASTM, made of 4mm thick substrate of aluminum composite panel having 0.50mm thick skin of aluminum both side.The front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type XI of ASTM with coloured scheme, including subject matter, message (bi-lingual), symbol and borders etc as per IRC 67-2001.The aluminum composite panel shall be suitably fixed on top, bottom and sides of stainless steel frame work as per directions of Engineer-in Charge.Retro reflective tape shall be of brand : 3M, Avery Denni & the contractor would be required to submit tax paid vouchers of retro reflective tapes used in the work of approved makes.Note:- Design/pattern shall be approved by GE |
| 43 | Supplying and fixingin replacement water meter level indicator, electronic type, for over head water tank , reservoir, comprising of ten stage magnetic sensor concealed in stainless steel tube of required length, multicore cable & features of alarm on low and high levels with indications to make itfully serviceable/ functional at site complete all as specified and as directed. |
| 44 | Supplying and fixingin replacement water meter level indicator, electronic type, for over head water tank , reservoir, comprising of five stage magnetic sensor concealed in stainless steel tube of required length, multicore cable & features of alarm on low and high levels with indications to make itfully serviceable/ functional at site complete all as specified and as directed. |
| 45 | Supply and fixing in replacementmild steel work for manhole cover, stair case steps, pit chamber cover , doors/gate, fencing on boundary etcmade of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, including drilling holes, notching for wire etc flat iron filletsincluding weling work all necessary drilling, bolting or rivetting , PCC work etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers, steps etc complete all as specified and as directed. |
| 46 | S&F Energy savingLED Flood light 50 Watt environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting including taking down unsv complete all as specified and as directed at site. |
| 47 | S&F LED Flood light fitting 100 wattenergy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting etc complete fixed bracket & suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from flood light to fittings connector including taking down unsv complete all as specified and directed. |
| 48 | S&F LED Flood light fitting 120 wattenergy saving environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting including taking down unsv complete all as specified and as directed at site. |
| 49 | S&F LED Flood light fitting 150 wattenergy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lightingincluding taking down unsv complete all as specified and as directed at site. |
| 50 | S&F street light fitting 60 watt LED, energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07including taking down unsv complete all as specified and as directed |
| 51 | S&F in replacement of 100W LED street light made up of die cast aluminium housing with hight efficient LED as lightning source with toughened glass having IP66 protection and impact resistance of Ik 07 with inluding all fitting such as suitable cableincluding taking down unsv complete all as specified and as directed |
| 52 | S&F Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.2 mtr long bend to an angle of 120 degree with 02 Nos mild steel clamp 50mm x 50mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer incl dismantling taking down unsv complete all as specified and directed. |
| 53 | Supply and fix in replacement of MS clamp (suitable for holding street light bracket on steel pole)made out of 40 mm wide 6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia-3 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps complete all as specified and directed. |
| 54 | Supply and fix in Replacement of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuityconductor connected to earth plate by means of GI light bolt nuts, check nuts and washers ofincluding providing earth wire protection pipe GI light grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore GI pipe medium grade with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0using MS TMT 8mm dia @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed. |
| 55 | M&L for fixing in replacement of galvanised iron strip of size 32 x 6 mm for earth continuity from test point to aluminium conductors above for inter connections including brazing for joints copper/brass nuts, bolys/ washers with insulators for necessary fixing on wall/trenches etc complete, all as specified and directed. |
| 56 | S & F first aid kit suitable for water supply installations having metal cabinet of suitable size front size openable and first aid symbol and words \"FIRST AID KIT\"marked on the front lid and mounting on wall with suitable fastners complete all as specified and directed by Engineer-In-Charge comprising with following items:-(a) Burn cream-1 (b) Antiseptic cream 10g- 2(c) Antiseptic Lotion 100 ml -1(d) Antiseptic Band Aid - 10 (e) Tweezer-SS 7 cm-1 (f) Antiseptic wipes-10(g) Abosrbent cotton 20gms-1(h) Sterile dressing medium -3(i) Sterile dressing large -3(j) Haemostatic absorbable sponge -1 (k) Hand santizer 100ml-2 (l) Dusting powder 10g-1-2 (m) Pain Gel cream-1(n) Cotton Tape 1.25x 1mt-1 (o) Scissors 5.5\"\" tough cut-1(p) Torch light with battery-01 (q) Instant cool pack 50g-2 (r) Breathing mask-02 (s) Gloves Examination-2 , (t) Aspirin tablet 75 mg -10 (u) Paracetamol tablet 500 mg-10 (v) Plastic glass-1(w) Digital Infrared Thermometer of make complete all as specified and directed by Engineer in Charge. |
| 57 | S & F illuminated display board with name of water supply installations of size 1.25mx0.2mx0.9m (LXBXH) with flex of light blue (MES Colour ) colour of letters shall be white, outer side fabrication bordered with aluminium angle frame of 25mmx25mmx3mm thick, inner side fabricated with 12mm MS square bar, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 nos 30mmx4mm thick MS Flat of 2m length welded to GI Pipe and nut bolt and washer with display board not less than 3m and PCC 1:2:4 type B1 for foundation including all internal wiring s and illuminated with LED 40W Tubelight fittings 01 Nos SMC/FRP junction box 140mmx140mmx95mm inner dimension including its fixing arrangement and written letters in capital, size of letters proportion with overall size of baord complete all as specified and as directed . Note (i) Before manufacturing boards drawing and design of board including colour of board shall be approved by Engr-in-Charge (ii) Each board display name shall be given seperately. |
| 58 | S & F illuminated display board with detailed schematic diagram of water supply installations including source, tanks of all capacity, suction line, discharge line, NRVs, Sluice valves etc in colored of size 1.25mx0.2mx0.9m (LXBXH) on flex, outerside fabrication bordered with aluminium angle frame of 25mmx25mmx3mm thick, innerside febricated with 12mm MS square bar,including all internal wiring s and illuminated with LED 40W Tubelight fittings 01 Nos SMC/FRP junction box 140mmx140mmx95mm inner dimensionincluding its fixing arrangementon wall or as directed by Engg-in-charge, complete all as specified and as directed . Note (i) Before manufacturing boards drawing and design of board including colour of board shall be approved by Engr-in-Charge (ii) Each board display name shall be given seperately |
| 59 | Supply and fixing of Acrylic sheet of desired size for water bodies pipeline layout diagram for Manekshaw Centre with fixing arrangement. The representative of contractor will visit the site and take details of the water bodies pipeline layout plan in total for manekshaw centre, complete all as specified and directed by Engg-in-Charge. Note (i) Before manufacturing boards, design and size of board including colour of board shall be approved by Engr-in-Charge |
| 60 | Supply and fixing of Acrylic sheet of desired size for Fire Fighting system diagram ( including Hydrants, pipeline, sprinkler, hosebox, hosereel etc) for Manekshaw Centre with fixing arrangement. The representative of contractor will visit the site and take details of the fire fighting system in total for every floor of the building at manekshaw centre, complete all as specified and directed by Engg-in-Charge. Note (i) Before manufacturing boards, design and size of board including colour of board shall be approved by Engr-in-Charge |
| 61 | S&F in replacement of shock treatment chart in multi languages i.e english and hindi of size 2 x1 Sqm in wooden base with proper frame and arrangement to fix, complete all as specified and directed by engineer in charge. |
| 62 | Supply, fixing, testing and commissioning in replacementof 1100 Volts grade \"Heavy duty\" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 10 Sqmm nominal cross sectional area 4 core with suitable glands and lugs as per site requirement confirming to IS specifications, complete all as specified and directed . |
| 63 | Supply and fixing in replacement of PVC copper cable of size 2.5 sqmm x 4 core with suitable glands and lugs as per site requirement confirming to IS specifications, complete all as specified and directed . |
| 64 | Supply and fixing of No Entry Authorized Personnel Only Sign Board of rectangular shape in ACP sheet with white colour base and letters in red colour including its fixing arrangement and letters writtenin capital, size of letters proportion with overall size of baord complete all as specified and as directed . Note:- Before manufacturing boards, design of board including colour of board shall be approved by Engr-in-Charge |
| 65 | Supply and fixing of Notice cum display board for water supply installations with Heavy-Duty Aluminium Frame of size 2x1 metre Pin-up Surface (Red/Green), Soft Board Core with ABS Corners, complete all as specified and as directed . |
| 66 | Supply only water testing kit for water supply installations, complete all as specified and as directed . |
| 67 | Supply and fixing of Acrylic sheet of desired size to write the details such as type of equipment, SM No, MES No, Capacity, Cost, Date of Installation, Do\"s and Don\"ts at Water supply installation etc. with blue colour base and letters in white colour including its fixing arrangement and letters writtenin capital, size of letters proportion with overall size of baord complete all as specified and as directed. Note:- Before manufacturing boards, design and size of board including colour of board shall be approved by Engr-in-Charge |
| 68 | Supply, fixing, jointing & testing in replacement ofpresure gauge with 100mm dial, 0-14 kgs rating all as specifieddirected by Engineer-in-Charge. |
| 69 | Supply, fixing, jointing & testing in replacement of presure switches IPS 100 or approved equivalent including making connection with the control panel and the presure vessel complete in all respects the electric continuity is maintained between contacts NC and COM under normal conditions the contacts changeover to No & COM on rise of presure to preset valve all as including taking out of unserviceable presure switches complete all as specified and directed. |
| 70 | M&L for Disconnection of mechanical/electrical and water connection of the centrifugal pump and diesel driven motor of capacity of 90 KVA from base plateincluding transportation to and fro upto workshop and carefully opening for replacement of bushes, mechanical seal, ball bearing rubber gasket nut and bolt fixing the require new parts (parts such as shaft impeller, coupling, mechanical seal and bearing shall be supplied under relevant item of schedule) fuel tank should be replaced as available on site with new fuel tank and complete re-fixing its in original position and making good all mechanical/electrical and water connection and tesing complete all as specified. Note : Rate including transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation and testing and commisioning. Add fuel tank replacement |
| 71 | Supply only shaft suitable for centrifugal pumps of capacity of 90 KVA |
| 72 | Supply only GM impeller suitable for centrifugal pumps of capacity of 90 KVA |
| 73 | Supply only MS Coupling suitable for centrifugal pumps of capacity of 90 KVA |
| 74 | Supply only Bearing suitable for centrifugal pumps of capacity of 90 KVA |
| 75 | Supply only Mechanical Seal for centrifugal pumps of capacity of 90 KVA |
| 76 | Material & labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSHPVC insulated, unsheathed copper conductor cable in and including PVC casing -n-caping of any size/dia, medium grade fixed on surface of wall complete incl all PVC accessories / fittings, brass screws, washers etc, incl providing 3mm thick plastic laminated sheet top cover for mounting switches/ sockets on boards with suitable size sunk boxes or with PVC gang boxes as per site requirements and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly including taking down and making good the disturbed surfaces with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed for the followings :- |
| 77 | One light /Exhaust fan point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed. |
| 78 | One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed. |
| 79 | One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed. |
| 80 | All as per serial item No 64 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed. |
| 81 | Supply & fixing switch piano flush type, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge |
| 82 | Supply & fixing switch piano flush type,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge |
| 83 | Supply & fixing of socket outlet 3 pin, 06 Amps and 3 pin16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed by Engr-in-Charge |
| 84 | Supply & fixing of socket outlet 3 pin, 06 Amps 240 volts complete all as specified & directed by Engr-in-Charge |
| 85 | Material and labour for sub main wiring with 2x6 Sqmm nominal cross sectional area (two single core cable of 6 Sqmm for Phase and neutral + 01 single core cable of 4.0 Sqmm for earth wire), FRLSH, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing, including taking down complete all as specified & directed. |
| 86 | Supply and fixing in replacement of sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge. |
| 87 | S & F in replacement of MCB, SP, AC, 240 volts \"B\" series capacity of 06 to 32 Amps, 10kA and making connections with suitable thimble complete all as specified & directed. |
| 88 | S & F in replacement ofMCB, DP (Double Pole), AC, 240 volts, B series capacity 20 Amps to 32 Amps10kA and making connections with suitable thimble complete all as specified & directed. |
| 89 | Supply & fixing in replacement to existing LED tube light batten fitting 20W, (single Side Connection) including LED Rod including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 90 | Material and labour for painting two coat of synthetic enamelpaint over a coat of red oxide primer as per existing pattern or scheme, on pipe lines including preparation of surfaces by scratching and removing the rust completeall as specified and directed. |
| 91 | S & F in repair of BLDC motor 1200mm ceiling fan ( including replacement of unserviceable parts i.e. hanging rod ,re-winding, wire, damaged blades etc.) complete all as specified & directed. |
| 92 | S& F in repair of heavy duty industrial Exhaust fan 450mm size ( including replacement of unserviceable parts i.e. re-winding, wire, damaged frame/blades etc.) complete all as specified & directed. |
| 93 | Supply and fix in replacement to existing post top light fitting with LED 40 wattpost top light fitting AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and 20 watt LED lamp all as specified and directed by Engr-in-Charge. |
| 94 | S&F in replacement Bollard LED light 1x10 watt, die cast aluminium cylindrical pipe with cover clear acrylic cylinder, housing the lamp holder, reflector assembly, Dust-proof and water resistant as approved by Engg-in-Charge, complete all as specified and directed by Engr-in-Charge. Note -:Necessary PCC work using 1:2:4 type B1 for foundation incl mounting the entire frame shall be carried out as directed, Cost for the entire job shall be deemed to be included in the quoted rate of item itself. |
| 95 | Material and labour for PCC (1:3:6) type C-2 (using 20 mm graded stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge. |
| 96 | Material and labour for Brick work with sub class \"B\" bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site all as specified and as directed at site by the Engr-in-Charge. |
| 97 | Supply and fixing in replacement of PVC copper cable multitstranded of size 10 sqmm x 1 core with suitable glands and lugs as per site requirement confirming to IS specifications, complete all as specified and directed . |
| 98 | Supply and fixing in replacement of PVC copper multitstranded cable of size 16 sqmm x 1 core with suitable glands and lugs as per site requirement confirming to IS specifications, complete all as specified and directed . |
| 99 | Supply and fixing in replacement of PVC copper multitstranded cable of size 25 sqmm x1 core with suitable glands and lugs as per site requirement confirming to IS specifications, complete all as specified and directed . |
| 100 | S & F in replacement of UPVC pipe of 50mm dia complete all as specified & directed. |
| 101 | S & F in replacement of UPVC pipe of 80mm dia complete all as specified & directed. |
| 102 | Material and Labour for machine cut kota stone slab flooring 40-50 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed. |
| 103 | S & F in replacement of Chequer plate steel solid trench cover of4mm thickness & suitable size as per existing trench complete all as specified & directed. |
| 104 | S & F in replacement of FRP grating trench cover of suitable size as per existing trench complete all as specified & directed. |
| 105 | Supply, fixing, testing and commissioning in replacementof 1100 Volts grade \"Heavy duty\" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 06 Sqmm nominal cross sectional area 2 core with suitable glands and lugs as per site requirement confirming to IS specifications, complete all as specified and directed . |
| 106 | An amount of Rs 2,11,996.50 shall be deducted from BOQ on account of schedule of credit |