| 1 | Supply, laying, Jointing connecting in replacement of LT UG cable XLPEinsulated,PVC bedded galvanised steel strip or wirearmoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches/ on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers including taking down old LT UG cable complete all as specified and directed. |
| 2 | All as per item No. 1.00 above but for 06 Sqmm 2 Core complete all as specified and directed. |
| 3 | All as per item No. 1.00 above but for 16 Sqmm 4 Core complete all as specified and directed. |
| 4 | All as per item No. 1.00 above but for 25 Sqmm 4 Core complete all as specified and directed. |
| 5 | All as per item No. 1.00 above but for 35 Sqmm 3.5 Core complete all as specified and directed. |
| 6 | All as per item No. 1.00 above but for 50 Sqmm 3.5 Core complete all as specified and directed. |
| 7 | All as per item No. 1.00 above but for 70 Sqmm 3.5 Core complete all as specified and directed. |
| 8 | All as per item No. 1.00 above but for 95 Sqmm 3.5 Core complete all as specified and directed. |
| 9 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 10 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed.Note: Thickness of sand cushion after punning down will be measured and paid. |
| 11 | Supply and laying wellburntsub class‘B’ bricks( designated 75) locally available best quality, laid dryin trenches forprotection of underground cable complete all as specified and directed. |
| 12 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and directed. |
| 13 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and directed. |
| 14 | Supply and laying in replacement of GI tube light grade as in cable protection pipe including all fittings & taking down / taking out from trenchcomplete all as specified and directed for the following sizes :- |
| 15 | 25 mm bore |
| 16 | 40 mm bore |
| 17 | 80 mm bore |
| 18 | Supply and layingof DWC Double wall corrugated Duct Pipe as cable protection pipe in trench/wall/pole including all fittings complete all as specified and directed for the following sizes (OD X ID) :- |
| 19 | Size 40 X 32 mm |
| 20 | Size 63 X 50 mm |
| 21 | Size 75 X 63 mm |
| 22 | Material and labour for cuttingof road/ hard standingn exc 20cm widthandn exc 60cm in depth for laying ofcable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1to match with existing surfacecomplete all as specified and directed. |
| 23 | Supply and fix in replacement of 170 Watt LED flood light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP65 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including surface mounting using adjustable MS cradle of thickness 5 mm provided with the fixture including taking down existing unserviceable flood light fitting of any description complete all as specified and directed.Note :- LM 79test report, LM 80 report with minimum 9000 hrs testing to support 50K life TTC and dirver NABL accreditated report shall be submitted before execution of work. |
| 24 | All as per Item No.17.00 but of 210 Watt LED flood light fitting complete all as specified and directed. |
| 25 | Supply and fix in replacement of LED Post top light fitting 40 Watt , made in die-cast aluminum housing with decorative clear opal acrylic diffuser, IP 65 protection, spun aluminum powder coated canopy, low power Warm White (WW) LEDs connected in series and parallel combination with better heat dissipation arrangement with LED color temperature- 3000K ±300K, Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 5KV complete suitable for up to 60mm OD pipe entry with fixing bolts including taking down existing unserviceable post top light of any description complete all as specified and directed Note :- LM 79test report, LM 80 report with minimum 9000 hrs testing to support 50K life TTC and dirver NABL accreditated report shall be submitted before execution of work. |
| 26 | Supply and fixing, in replacementLED street light fitting70/75Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 27 | Supply, fixing and testing in replacement automatic Nature switch of capacity 3 KW single phase for street light complete with high and low voltage and overload protection, degree of protection confirm to 1P-55 AC, SP complete with MCB and power contactor fixed on pole with 25 X 3mm MS strip clamp including provision of 6 sqmm 3 core cable for connection complete all as specified and directed.Make - Kakatiya Energy system Model SWADEEP |
| 28 | Supply and fixin replacement of bracket for street light fittings made out GI pipe of lightgrade 1.2 m long 40 mm pipe each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primerincluding taking down old unserviceable bracket of any shape and size complete all as specified and directed. |
| 29 | S&F in replacement ofIP65/IP66 Thermoplastic Polycarbonate cable Junction box for street lights; size not less than 250mm x 250mm x 160 mmsuitable for cable dimensions of size10 to25 sq mm, with 25 sqmm terminal of 32 Amps rating for three phase & neutral mounted on din railwith locking arrangement fixed to PSC/Steel Poles by means of suitable size of clamps made of MS flat 20 x 4mm - 2 Nos with nut, bolts & double washers andincluding provn for fixing 01 No. single pole, MCB, 10 amps,10KA, ‘B’ series with ON/OFF flap complete all as specified and directed. |
| 30 | Supply, install, testing and commisioning in replacement of U/S all in one integrated LED solar light hybrid typeconsists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, microwave sensor,inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Solar street light with IP65 ingress protection having a system wattage of with 50Wp high efficiency monocrystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, >23.4 Ah Lithium Ferro Phosphate(LiFePO4) battery with proper battery management system. LED lumen efficacy shall be greater than 140lm/W and LED driver should have >90% efficiency. Typical correlated colour temperature should be 5700K with CRI>70. It should have microwave sensor based movement detection and dim level adjustment to effectively extend the working time. AIO should be onsite configurable via a handheld remote. The luminaire should be housed in IK 08 impact resistance certified aluminum with polycarbonate lens cover. The luminaire shall have a specially designed adjustable pole mounting piece for optimal light distribution. LED Wattage not >=35 Watts and Lumens not<=5000 Lumens, with 5 Years OEM Service warranty, and replacement of unserviceable lights of any type and capacity and including necessary civil work and incl GI pipe Bracket of suitable dia pipe bend to shape of approx length 1.5 Mtr incl 2 no. MS Clamp of flat iron of suitable size complete with nut, bolt, washers complete all as specified and directed. |
| 31 | Supply and fix in replacement 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 200 Amps complete all as specified and directed. |
| 32 | S&F in replacement MCCB 3 pole, 415 V, adjustable type 25 to 100 Amp with breaking capacity 16 KA complete all as specified anddirected. |
| 33 | S&F in replacement MCCB 3 pole, 415 V, adjustable type 125 Amp with breaking capacity 16 KA complete all as specified anddirected. |
| 34 | S&F in replacement MCCB 4 pole, 415 V, adjustable type 160 Amp with breaking capacity 36 KA complete all as specified anddirected. |
| 35 | S&F in replacement MCCB 4 pole, 415 V, adjustable type 200 Amp with breaking capacity 36 KA complete all as specified anddirected. |
| 36 | S&F in replacement MCCB 4 pole, 415 V, adjustable type 250 Amp with breaking capacity 36 KA complete all as specified anddirected. |
| 37 | M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed.Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. |
| 38 | Design, supplying, installing, testing and commissioning LT Outdoor type, double door IP - 65 type panel board factory fabricated cubicaltype weather andvermin proof with locking arrangement made out of MS CRCA sheet 3.15 mm thick suitable size of channel for base complete with aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting MCCBs,metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixed on angle iron frame with appropriate size and thickness angle iron duly marked the incoming & alloutgoing controls and comprising with the following duly CPRI Approved.Incomer - MCCB 4P 600A 50kA-1No, Out going:-MCCB 4P 200A 35kA-3No,MCCB 4P 160A 25kA -02 Nos, MCCB 4P 100A 25kA -02 Nos MCCB TP 63 A, 25 KA-01 No, 04 Nosmain aluminium Bus Bar shall be of 1.5 times of Incomer, all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-300) with ASS-1No, Current transformer of rating 300/5A-1No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, PCC foundation complete all as specified and directed. |
| 39 | Design, supplying, installing, testing and commissioning LT Outdoor type, double door IP - 65 type panel board factory fabricated cubicaltype weather andvermin proof with locking arrangement made out of MS CRCA sheet 3.15 mm thick suitable size of channel for base complete with aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting MCCBs,metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixed on angle iron frame with appropriate size and thickness angle iron duly marked the incoming & alloutgoing controls and comprising with the following duly CPRI Approved.-Incomer- Incomer - MCCB 4P 350A 36kA-1No, Out going:-MCCB 4P 250A 25kA-1No,MCCB 4P 160A 25kA -02 Nos, MCCB 4P 100A 25kA -01 Nos MCCB TP 63 A, 25 KA-01 No, 04 Nosmain aluminum Bus Bar shall be of 1.5 times of Incomer , all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-300) with ASS-1No, Current transformer of rating 300/5A-1No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, PCC foundation complete all as specified and directed. |
| 40 | Design, supplying, installing, testing and commissioning LT Outdoor type, double door IP - 65 type panel board factory fabricated cubicaltype weather andvermin proof with locking arrangement made out of MS CRCA sheet 3.15 mm thick suitable size of channel for base complete with aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting MCCBs,metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixed on angle iron frame with appropriate size and thickness angle iron duly marked the incoming & alloutgoing controls and comprising with the following duly CPRI Approved-Incomer- Incomer - MCCB 4P 250A 36kA-1No, Out going:-MCCB 4P 200A 25kA-1No,MCCB 4P 160A 25kA -01 Nos, MCCB 4P 100A 25kA -02 Nos MCB TPN 63 A, 10 KA-01 No, 04 Nosmain aluminum Bus Bar shall be of 1.5 times of Incomer , all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-300) with ASS-1No, Current transformer of rating 300/5A-1No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, PCC foundation complete all as specified and directed. |
| 41 | Design, supplying, installing, testing and commissioning LT Outdoor type, double door IP - 65 type panel board factory fabricated cubicaltype weather andvermin proof with locking arrangement made out of MS CRCA sheet 3.15 mm thick suitable size of channel for base complete with aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting MCCBs,metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixed on angle iron frame with appropriate size and thickness angle iron duly marked the incoming & alloutgoing controls and comprising with the following duly CPRI Approved-Incomer- Incomer - MCCB 4P 200A 36kA-1No, Out going:-MCCB 4P 160A 25kA-1No,MCCB 4P 100A 25kA -02 Nos, MCB TPN 63 A, 10 KA-01 No, 04 Nos main aluminum Bus Bar shall be of 1.5 times of Incomer , all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-300) with ASS-1No, Current transformer of rating 300/5A-1No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, PCC foundation complete all as specified and directed.. |
| 42 | Design, supplying, installing, testing and commissioning LT Outdoor type, double door IP-65 type panel board factory fabricated cubicaltype weather and vermin proof with locking arrangement made out of MS CRCA sheet 3.15 mm thick suitable size of channel for base complete with aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting MCCBs,metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixed on angle iron frame with appropriate size and thickness angle iron duly marked the incoming & alloutgoing controls and comprising with the following duly CPRI Approved.Incomer - MCCB 4P 160A 36kA-1No, Out going:-MCCB 4P 100A 25kA-1No,MCB TPN 63 A, 10 KA-01 No, 04 Nos main aluminum Bus Bar shall be of 1.5 times of Incomer , all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-300) with ASS-1No, Current transformer of rating 300/5A-1No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, PCC foundation complete all as specified and directed. |
| 43 | Design, supplying, installing, testing and commissioning LT Outdoor type, double door IP - 65 type panel board factory fabricated cubicaltype weather andvermin proof with locking arrangement made out of MS CRCA sheet 3.15 mm thick suitable size of channel for base complete with aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting MCCBs,metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixed on angle iron frame which is made out of 50 x 50 x 6 mm thick angle iron duly marked the incoming & alloutgoing controls and comprising with the following duly CPRI Approved-Incomer- MCCB 4P 250A 36kA-1No, Out going:-MCCB 4P 100A 25kA-1No, , MCB TPN 63 A, 10 KA-01 No, 04 Nosmain aluminum bus bar. Bus Bar shall be of 1.5 times of Incomer , all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Microprocessor based threephase phase electronic 01 No.Digital Ammeter (0-300) with ASS-1No, Current transformer of rating 300/5A-1No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, PCC foundation complete all as specified and directed. |
| 44 | Design, supplying, installing, testing and commissioning LT Outdoor type, double door IP-65 type Feeder Pillar Box board factory fabricated cubicaltype weather and vermin proof with locking arrangement made out of MS CRCA sheet 3.15 mm thick suitable size of channel for base complete with aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting MCCBs,metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixed on angle iron frame with appropriate size and thickness angle iron duly marked the incoming & alloutgoing controls and comprising with the following duly CPRI Approved.Incomer - MCCB 4P 100A 36kA-1No,main aluminum Bus Bar shall be of 1.5 times of Incomer , all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-300) with ASS-1No, Current transformer of rating 300/5A-1No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, PCC foundation complete all as specified and directed. |
| 45 | Total in Figures |
| 46 | Quoted Amount in Words |