| 1 | Taking down carefully existing point wiring of any type (i.e on wooden batten, surface conduit, casing capping or concealed conduit except existingconduit) complete for light, fan, socket or power point with fittingSupply and fixing ixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawal plug, screw etc including removing materials from site for taking credit of unserviceable items and re-fixing the serviceable items as per schedule and making good disturbed surface of walls, floors etc, complete all as specified and directed.Note : (i) The existing conduit of concealed wiring will not be removed from site and same will be reused for point wiring under respective item hereunder.(ii) The qty of serviceable/ unserviceable items will be ascertained by the BOO detailed by GE and serviceable items (such as LED fittings/LED tube and bulb /ceiling/ Exhaust Fans and geysers, electric meters) will be refixed under respective item hereunder and unserviceable items such as switches, sockets, ceiling rose, holders, brackets, bulkhead fittings, LED fittings, MCB DBs, sunken boxes andfixtures etc. shall be issued to contractor under schedule of credit all as specified and directed. |
| 2 | Matrial & Labour for point wiring with 1.5 sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through existing metallic/ rigid PVC concealed conduit including replacement of pressed steel teRunning Meterinalmounting box , for mounting fittinglike modular switches, sockets, andfixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm sizecopper conductor cable green in colour as a earth wire and connected to common earth dolly complete all as specified and directed, Note : Cost of Metal boxes and modular accessories like cover plates internal outer shall be deemed to be included in quoted rate) |
| 3 | (a)Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push. |
| 4 | (b)One light point controlled by two Nos of two way switch. |
| 5 | (c) One socket outet point 5 amps on the same board. |
| 6 | (d) One socket outet point 5 amps on the independent board. |
| 7 | All as Ser item 2 here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet. |
| 8 | Matrial & Labour for point wiring with 1.5 sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings andbrass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed.Note : Cost of Metal boxes and modular accessories like cover plates internal outer shall be deemed to be included in quoted rate) |
| 9 | (a)Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push. |
| 10 | (b)One light point controlled by two Nos of two way switch. |
| 11 | (c) One socket outet point 5 amps on the same board. |
| 12 | (d) One socket outet point 5 amps on the independent board. |
| 13 | All as Ser item 8 here in before but with 2.5 sq mm wire and earth wire (green colour) of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet. |
| 14 | Material and labour for modular surface point wiring for followingpoint controlled by one switch (using red black, green colour wires as colour coding) complete with 1.5 sqmm (nominal cross section area) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volts (ISI marked) drawn and including surface PVC Conduit with all fitting and accessories i.e pipe bend, pipe hook, elbow junction boxes etc including pressed steel powder coated sunken teRunning Meterinal box suitable for modular switch socket (min 50 mm deep and 1.6 mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plates) suitable for fixing the modular switches /sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi standard copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls .ceiling /floor etc by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and directed by Engr-in-Charge. Note :. Switch /socket/regulator shall be measured and paid separately |
| 15 | (a) For one light/fan/buzzer point controlled by one 5 Amp swtich one way |
| 16 | (b) For one three pin sockets outlet 5 Amps independent board completed |
| 17 | (c) For one three pin 5 Amps sockets outlet on the same board completed with other switches |
| 18 | (d) For one light point controlled by two way swtich |
| 19 | (e) All as serial item No 14 here in before but 2.5 sqmm for 3 pin 15 Apr modular type socket outlet complete all as specified and directed by Engr-in-Charge |
| 20 | Supply and Fixing Modular switch 6 Amp 1 way 1 module size complete all as specified and as directed . |
| 21 | Supply & Fixing of Modular switch 6 Amp 2 way 1 module size complete all as specified and as directed. |
| 22 | Supply and Fixing Modular switch 16 Amp 1 way with indicator 1 module size complete all as specified and as directed. |
| 23 | Supply and Fixing Modular socket shuttered 6 Amp 2/3 pin combined 2 module size complete all as specified and as directed . |
| 24 | Supply and Fixing Modular socket 16 Amp multipurpose type 2 module sizecomplete all as specified and as directed. |
| 25 | Supply and Fixing Modular Fan regulator step type 120 watts 2 Module size complete all as specified and as directed. |
| 26 | Supply and Fixing Modular bell switch 6 Amp1 module size complete all as specified and as directed. |
| 27 | Supply and Fixing Ceiling rose, surfacebakelite 3 teRunning Meterinal, 240 volts, 5 Amps with back plate of 3 mm thickbakelite, laminated hylem sheet of appropriate size, complete ,all as specified. |
| 28 | Supply and fixing Lamp holderbattan type, PVC/Polycarbonate type with back plate suitable for batten fittings including presto plastic board for resting to holder complete all as directed |
| 29 | Supply and fixingin repair replacementMCB single pole, 240 volts,63 Amp, rupturing capacity 10 kA, ‘C’ curve type complete all as specified and directed. |
| 30 | Supply and fixing of single phase call bell ‘DING DONG’, AC 230 volts single pole fixed over and including pressed steel sunk box of size 175 X 100 mm duly covered with 3 mm thick bakelite sheet complete all as specified and directed. |
| 31 | Supply and fixingMCB single pole, 240 volts, 6 to 32 Amp, rupturing capacity 10 kA, ‘C’ curve type complete all as specified and directed. |
| 32 | Supply and fixingMCB single pole, 240 volts, 40 Amp, rupturing capacity 10 kA, ‘B’ curve type complete all as specified and directed. |
| 33 | Supply and fixingMCB SPN, 240 volts, 32 Amp to 40 Amp, rupturing capacity 10 kA, ‘C’ curve type complete all as specified and directed. |
| 34 | Supply and fixingMCB TPN, 415 volts, 63 Amp, rupturing capacity 10 kA, ‘C’ curve type complete all as specified and directed. |
| 35 | Supply and fixingsheet metal enclosure for DB’s (Double door type), single pole and neutral, 12ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wallwith IP-43 and IK-09 protection complete all as specified and directed. |
| 36 | Supply and fixingsheet metal enclosure for DB’s (Double door type), single pole and neutral, 4ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wallwith IP-43 and IK-09 protection complete all as specified and directed. (for Offrs Servant qtrs) |
| 37 | Supply and fixingsheet metal enclosure for DB’s (Double door type), triple pole and neutral, 6 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wallwith IP-43 and IK-09 protection complete all as specified and directed. (for Offrs Md Accn) |
| 38 | Supply and fixingsheet metal enclosure for DB’s (Double door type), triple pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wallwith IP-43 and IK-09 protection complete all as specified and directed. (for Offrs Md Accn) |
| 39 | Supply and fixing sub main wiring with 4 runs of 6.0 sqmm single core, multi-stranded PVC insulated, FRLS unsheathed cable 1100 Volts grade with copper conductor drawn through and including concealed non metalic PVC conduit, medium grade, ISI marked, suitable size with conduit fittings and accessories concealed in wall/ceiling/floor including 1 runs of 6.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly incl taking down old unsv one from site complete all as directed (For Offrs Md Accns)NOTE: Four runs of 6.0 sqmm copper cable and oneruns of 6.0 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length |
| 40 | All as per ser item No. 39 above but for sub main wiring with 2 run of 6.0 sqmm & 1 run of 6.0 sqmm as earth wireNOTE: Two runs of 6.0 sqmm copper cable and one run of 6.0 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length (for JCOs/ORs Md Accn) |
| 41 | All as per ser item No. 39 above but for sub main wiring with 2 run of 4.0 sqmm & 1 run of 4.0 sqmm as earth wireNOTE: Two runs of 4.0 sqmm copper cable and one run of 4.0 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length (For AC & Geysers) |
| 42 | All as per ser item No. 39 above but for sub main wiring with 2 run of 2.5 sqmm & 1 run of 2.5 sqmm as earth wireNOTE: Two runs of 2.5 sqmm copper cable and one run of 2.5 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length (For Offrs Servant qtrs) |
| 43 | Matrial & Labourfor wiring with one run single core FRLS Wire, 1100 volt grade, PVC insulated and unsheathed cable with stranded copper conductor 1.5 sqmm (for inverter) drawn into existing PVC conduit with all accessories fixed concealed complete all as specified and directed.NOTE: (a)One run of 1.5 sqmm PVC FRLS multi stranded copper cable wire with seperate colour coding for inverter should be used, no extra cost will be paid in this account. |
| 44 | Supply and fixingCITY 2 Decorative wall light fixture made up of Polycarbonate type insulated body with back place, suitable for retrofit LED lamp B22 base including LED lamp 9 Watts complete all as specified and directed. |
| 45 | Supply and fixing in replacement of LED tube light fitting 10 Watts, four feet LED PRIDE PLUS NEO for all purpose surface and wall mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, prewired including connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. |
| 46 | Supply and fixing in replacement of LED tube light fitting 20 Watts, four feet LED PRIDE ESSENTIAL for all purpose surface and wall mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, prewired including connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. |
| 47 | Supply and fixing LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 48 | Supply and fix in replacement of security light fitting LED 25 Watt withaluminum pressure dia cast housing with touched glass cover IP-66 protectionIncludingsuitable size GI Bracketand accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting teRunning Meterinal including taking down oldsecurity light fittingall as specified and as directed. |
| 49 | Supply, install & testing in repair /replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 250mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan including cutting hole suitable for fixing exhaust fan complete all as specified and directed Note : The retrieved item /material will be handed to over to users /or deposit to E/M store yard |
| 50 | Supply, install & testing in repair /replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 200 mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan including cutting hole suitable for fixing exhaust fan complete all as specified and directed Note : The retrieved item /material will be handed to over to users /or deposit to E/M store yard |
| 51 | Supply, install & testing in repair /replacementexhaust fan, heavy duty, steel body AC single Phase, 230V of size 300mm sweep, with blades and frame and louvers complete fixed to wall with suitable MS bolts, grouted to wall including connecting up with & including 3 core flexible copper conductor cable from ceiling rose to exhaust fan complete all as specified and directed Note : The retrieved item /material will be handed to over to users /or deposit to E/M store yard |
| 52 | Supply and fixing sheet steel metal enclosure single pole & neutral with a 2 pin and earth plug and socket complete with one single pole MCB SP 20 Amp, 240 volts complete all as specified and directed. |
| 53 | Matrial & Labour for loadline distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and veRunning Meterin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, completeincl taking down old unsv one from site complete all as directed |
| 54 | All as per ser item No. 53 above but for VTPN 6 way, 415 volts |
| 55 | Supply and fixing MCCB triple pole and neutral (four pole) 100 Amps, 415 volts, 50 Hz, having theRunning Meteral setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 kA including making incoming and outgoing connections completeincl taking down old unsv one from site complete all as directed |
| 56 | All as per ser item No.55 above but for MCCB 4P, 63 Amps, 16 kA, 415 volts |
| 57 | Matrial & Labourfor earthing complete in repair/replacementwith galvanised earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below noRunning Meteral ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed.Note: - (i)Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately.(ii)On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. |
| 58 | Supply and fixing Casing /Caping 25 mm dia including connection complete all as specified and directed. |
| 59 | Supply and fixing Casing /Caping 20 mm dia including connection complete all as specified and directed. |
| 60 | Supply and fixing of switch piano flush button single pole two-ways 5 Ampere complete all as specified and directed. Make |
| 61 | Supply and fixing of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed. |
| 62 | Supply and fixing of switch piano flush button single pole one-way 15 Ampere complete all as specified and directed.Make Anchor/Havells/SSK |
| 63 | Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed. Make Anchor/Havells/SSK |
| 64 | Supply and fixing in replacement of Bell multi music type 5 Amp,230 Voltscomplete all as specified and directed. Make Anchor/Havells/SSK |
| 65 | Supply and fixing in replacement of remote control Bell multi music type 5 Amp,230 Voltscomplete all as specified and directed. (For officer & Offices) |
| 66 | Supply and fixing in repair /replacement of recessed mounted2\"x 2\" LED luminaire 30 W,6500 K with CRCA housing and with its ultra brite LED provide unifoRunning Meter light distribution which make it best in class proposition for modern work spaces. Suitable for aRunning Meterstrong/grid ceiling , an additional mounting frame is required for gypsum/POP ceiling installation . |
| 67 | Supply and fixingin repair /replacement of recessed mounted2\"x 2\" LED luminaire 30 W,4500 K (Yellow type) with CRCA housing and with its ultra brite LED provide unifoRunning Meter light distribution which make it best in class proposition for modern work spaces. Suitable for aRunning Meterstrong/grid ceiling , an additional mounting frame is required for gypsum/POP ceiling installation . |
| 68 | Supply and fixingin repair /replacementof ceiling light (circular type/rectangular/square type) of cap 18 Watt of 6500 K 230 Volt, 50 Hz complete all as specified and directed . |
| 69 | Supply and fixingin repair /replacementof ceiling light (circular type/rectangular/square type) of cap 15 Watt of 6500 K 230 Volt, 50 Hz complete all as specified and directed. |
| 70 | Supply and fixingin repair /replacementof ceiling light (circular type/rectangular/square type) of cap 12 Watt of 6500 K 230 Volt, 50 Hz complete all as specified and directed . |
| 71 | Supply and fixingin repair /replacementof Garden light(LED) Dom type (or as per sample)15 Watt of 6500 K 230 Volt, 50 Hz complete all as specified and directed. |
| 72 | Supply and fixingin repair /replacementof Garden light(LED) Dom type (or as per sample)15 Watt of 4500 K 230 Volt, 50 Hz complete all as specified and directed. |
| 73 | Supply and fixing in repair/replacment swtich socket combination outlet 2 in 1 ,3pin, 16 Amp flush type ,AC 220 volts ,50 Hz ccomplete all as specified and directed |
| 74 | Supply and fixing in repair/replacment swtich socket combination outlet 2 in 1 ,3pin, 6 Amp flush type ,AC 220 volts ,50 Hz ccomplete all as specified and directed . |
| 75 | Supply and fixing in repair/replacment Wall fan of plastic body single phase,AC 220 volts ,50 Hz 450 mm sweep and1200 rpm complete all as specified and directed. |
| 76 | Supply and fixing in repair/replacment two MCB box of plastic body to cover the MCB\"s as SPN complete all as specified and directed . |
| 77 | Supply and fixing in repair/replacment 1100 volt grade heavy duty cable PVC insulated standard conductor served with inner sheathing of PVC Tabe and overall PVC sheathed in service connection of size 4 sqmm twin core cableflat /circular typecomplete all as specified and directed |
| 78 | Supply and fixing in repair/replacment 1100 volt grade heavy duty cable PVC insulated standard conductor served with inner sheathing of PVC Tabe and overall PVC sheathed in service connection of size 6 sqmm twin core cableflat /circular typecomplete all as specified and directed. |
| 79 | Supply and fixing in repair/replacment 1100 volt grade heavy duty cable PVC insulated standard conductor served with inner sheathing of PVC Tabe and overall PVC sheathed in service connection of size 10sqmm twin core cableflat /circular typecomplete all as specified and directed. |
| 80 | Supply and fixing in repair/replacment post top lanternlan 25 W Mini Post Top LED Lamp 4000 K complete all as specified and directed . |
| 81 | Supply and fixing in repair/replacment pillar gate light fitting25 W Mini Post Top LED Lamp 4000 K complete all as specified and directed. |
| 82 | Supply and fixing in repair/replacment 6K IP66 Waterproof LED Flood Light of cap 50 watt ,240 volts , 50 Hz complete all as specified and directed. |
| 83 | Supply and fixing in repair/replacment mirror light LED of 12 Watt fancy type (or as per sample) ,240 volts , 50 Hz complete all as specified and directed by Engr-in-Charge. |
| 84 | Supply and fixingin repair/replacment universal driver for building LED Security light of capacity 25 Watt 220 Volts, 50 Hz , Single phase suitable for outdoor street light complete all as specified and directed |
| 85 | Supply and fixingin repair/replacment universal driver for building LED Security light of capacity 45Watt 220 Volts, 50 Hz , Single phase suitable for outdoor street light complete all as specified and directed |
| 86 | Supply and fixingin repair/replacment universal driver for building LED Security light of capacity 60 Watt 220 Volts, 50 Hz , Single phase suitable for outdoor street light complete all as specified and directed |
| 87 | Supply and fixingin repair/replacment universal driverfor building LED Security light of capacity 90Watt 220 Volts, 50 Hz , Single phase suitable for outdoor street light complete all as specified and directed |
| 88 | Supply and fixing in repair/replacmentdriver for 2x2 (600x600 mm) Ceiling /Recess type lightuniversal LED driver suitable for 36 Watt ,220 Volts, 50 Hz, Input voltage 100-250 V AC, 50 MA cut off voltage 300 Volts out put voltage 28-HOVOC 1200 MAcomplete all as specified and directed. |
| 89 | Supply and fixing in replacmentcapacitor of cap 2.5 MFD single phase 220 Volt, 50 Hz suitable for 1200/1400 mm sweep of ceiling fans complete all as specified and directed . |
| 90 | Supply and fixing in replacmentcopper twisted flexible wire of size 23/0076, 220 Volts complete all as specified and directed. |