| Sl. No. | Item Description |
| 1 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. |
| 2 | Removing excavated materials, soil to a distance exceeding 250 m but not exceeding 500 m depositing where directed at a level 1.5 m above starting point complete all as specified and directed. |
| 3 | Rolling and consolidating formation surfaces in cutting using exceeding 8 tonne and not exceeding 12 tonne power roller complete all as specified and directed. |
| 4 | Providing, laying and compacting 150 mm thick (compacted thickness)Granular Sub Base Course (GSB) grading as per Grade III as specified Table 900-1 of MORTH specifications for road and bridge works, 2013, in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag, or combination thereof as per the grading required. The materials are mechanically mixed, spread and levelling on the subgrade by using motor grader of adequate capacity, rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density at least 98% of the Maximum Dry Density. Consolidating to required gradient with finished surface tolerances as per table 900-1 of MORTH specifications for Road and Bridge works, 2013 complete all as specified and directed. |
| 5 | Supplying and laying of 75 mm thick (compacted thickness) WMM laid grading as per Table 400-13 of MORTH specifications for Road and Bridge works 2013 manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and consolidating to required gradient and camber complete all as specified tolerance to be as per Table 900-1 of MORTH specifications for Road and Bridge works 2013 complete all as specified and directed. |
| 6 | M&L for pre-cast cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified and directed. |
| 7 | M&L for rendering 15 mm thick cement plasterin cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brick-work, finished fair and even complete all as specified and directed. |
| 8 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 9 | Demolition of brickwork or stone/ boulder/lateritemasonry, built in cement mortar including all quoins, arches, pillars, etc, andremoving rubbish outside MD land complete all as specified and as directed. |
| 10 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level)complete all as specified and directed |
| 11 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m as directed by Engineer-incharge. |
| 12 | M&L for PCC 1:4:8, Type D2 (using 40mm graded stone aggregate) as in foundation, filling mass concrete complete all as specified and directed. |
| 13 | Returning and filling in, including spreading, leveling, watering and well ramming in layers not exceeding25 cm thick with soil obtained from excavation complete all as specified and directed. |
| 14 | M&L for lateritestone masonry, regular coursed, exceeding 10 cm in width built in cement mortar 1:6complete all as specified and as directed. |
| 15 | M&L for PCC 1:3:6, type C2 using 40mm graded stone aggregate as in surface channels and drainscomplete all as specified and directed. |
| 16 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/ stopped ends etc complete all as specified and directed. |
| 17 | Taking down of cement or cement lime plaster, any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 18 | M&L for rendering 15 mm thick cement plasterin cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brick-work, finishedeven and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for rendering 10 mm thick cement plasterin cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick-work, finishedeven and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping, benching, bands,seismic and other similar bands, including weathering, slightly rounded or chamfered angles and throating etc including necessary form work complete all as specified and directed. |
| 21 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 22 | Demolition of cement concrete (reinforced) of any description and in any positionnot otherwise specifically provided for complete all as specified and directed. |
| 23 | M&L for reinforced cement concrete (nominal mix) 1:1.5:3 type A-1 (using 20mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 24 | M&L for reinforced cement concrete (nominal mix) 1:1.5:3 type A-1 (using 20mm graded stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 25 | S&F steel TMT bars10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 26 | S&F steel TMT bars5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | M&L use and waste of timber as in formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for fair finished flat concrete surfaces complete all as specified and directed |
| 28 | M&L for use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions in square, rectangular and polygonal shape to rough finished surfaces of concrete complete all as specified and directed |
| 29 | S& F mild steel work in framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed |
| 30 | M&L preparation of new surfaces or previously untreated surfaces of steel and iron work of any description over 10 cm width or girth with applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer etc complete all as specified and directed. |
| 31 | S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)complete all as specified and directed. |
| 32 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out in hard/ dense soil complete all as specified and directed. |
| 33 | M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 34 | M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 35 | M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 36 | M&L for use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions in square, rectangular and polygonal shape to fair finished surfaces of concrete complete all as specified and directed |
| 37 | M&L for use and waste of Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc to fair finished surfaces of concrete complete all as specified and directed |
| 38 | M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 39 | M&L for use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat rough finished surfaces of concrete complete all as specified and directed. |
| 40 | M&L for rendering in two layers 10mm thick with cement mortar 1:6 as under coat and 10 mm thick with cement mortar 1:4 as finishing coat, finishing coat mixed with water proofing compound @ 3% by the weight of cement on stone masonry surfaces or surface other than fair face of brick-work on external surfaces of wall, finishing the surface fair and even complete all as specified and directed. Note: Water proofing compound will be measured and paid separately. |
| 41 | M&L for rendering 10 mm thick cement plaster on ceiling in cement mortar 1:3, finished evenand smooth without using extra cementcomplete all as specified and directed. |
| 42 | Supply only integral water proofingcompoundcomplete all as specified and directed. |
| 43 | M&Lforpreparationofnewplasteredwall surface withtwocoatsofdistemper oil emulsion overacoatofprimer complete all asspecifiedanddirected |
| 44 | M&Lforpreparationofnewplastered ceiling surface withtwocoatsofdistemper oil emulsion overacoatofprimer complete all asspecifiedanddirected. |
| 45 | Spreading and levelling in layers not exc. 25 cm thick including well ramming including watering as required complete all asspecifiedanddirected. |
| 46 | M&Lfor Hardcore of gauge not exceeding 63 mm using broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 47 | M&L for 100 mm thick plaincementconcrete1:4:8 TypeD2( using40 mm gradedstoneaggregate)asinsubbase complete all as specified and directed |
| 48 | M&L for joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed. |
| 49 | M&L for joint free Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10 mm thick screed bed in cement mortar 1:3 on stone/brick masonry surfaces, complete all as specified and directed. |
| 50 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixing in opening as per specification & drawing complete all as specified and directed. |
| 51 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 52 | S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 53 | S&F 150 mm (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 54 | S&F 150 mm size aluminium handles, cast type, anodised complete all as specified and directed. |
| 55 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 56 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 57 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty/ joining cleats, glazing clips, rubber neoprene packingin square not exceeding 0.50 sqm in each pane complete all as specified and directed. |
| 58 | M&L for 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 59 | S&F aluminium (Die-cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 60 | S&F vitreous China squatting pan, \"Orissa\" pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and directed. |
| 61 | S&F Vitreous China wash basin, white, flat back, size 550x400mm including brackets or erecting stand, waste pipe, etc. complete all as specified and directed. |
| 62 | S&F flushing cistern, low level, 10 Litres capacity, PVC white, valveless syphonic action type,with inlet, ball valve, float and handle including brackets for support, low or high density PVC flush pipe, complete all as specified and directed. |
| 63 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 64 | S&F Pillar tap, size 15 mm bore dia, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 65 | S&F Bib taps, size 15 mm bore dia, cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 66 | S&F Angle valves, 15 mm bore dia, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, screwed for iron pipe complete all as specified and directed. |
| 67 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 68 | S&F looking mirror, size 600mmx450mm, bevelled edge, selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 69 | S&F Soap dish, vitreous China white, approximate size 160x 160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 70 | S&F aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 71 | S&F 20 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 including all fittings such as bends, elbows, Tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs etc. fixed complete to walls, ceilings or in floors etc., complete all as specified and directed. |
| 72 | M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and directed. |
| 73 | S&F 75 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, laid in trenches or in floors complete all as specified and directed. |
| 74 | S&F 75 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 75 | S&F PVC (SWR) floor trap, outlet 75 mm dia,plain with grating including jointing with solvent cement complete all as specified and directed. |
| 76 | S&F 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, laid in trenches or in floors complete all as specified and directed. |
| 77 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 78 | M&L for Graniteslab or tiles 18mm to 20mm thick as in counter top of WHB or cooking platforms or similar works, (of any type) machine cut, bedded in cement mortar 1:4 including pointing in white cementand marble dust (1:2) with admixture of pigment to match with shade of granite stone including grinding and polishing complete all as specified and directed. |
| 79 | M&L for providing 75 mm thick plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection finished even and fairwithout using extra cement including necessary form work complete all as specified and directed. |
| 80 | S&F Rotational moulded polyethylene water storage tanks 1000 Ltr capacity, white (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I as directed by Engineer in charge complete all as specified and directed. |
| 81 | S&F Ball valves 20 mm bore dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and directed. |
| 82 | M&L for water proofing treatment of RCC roof with APP modified prefabricated five layer membrane of 4 mm thick and weight not less than 4.00 Kg per Sqm reinforced with non woven polyester matt reinforcement 160 gm/ Sqm (Weighing not less than 160 gm/ Sqm) over a solvent based bitumen primer, Shalitex primer @ 0.20 Kg per Sqm of same manufacturer\"s conforming to IS 3384-1986. Membrane shall be laid by torch application including minimum 7.50 cm side overlap and 10 cm end lap and painting over APP membrane sheet with aluminium bituminous paint @ 0.10 Ltr/ Sqm. All cracks in roof shall be filled with cement putty using suitable bonding agent (Shalocrete 42) before laying cement plaster complete all as specified and directed. |
| 83 | M&L for 25 - 40 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in padding on roof, benching & filleting complete all as specified and directed. |
| 84 | M&L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 mixed with water proofing compound @ 3% by the weight of cement for laying floor finishes complete all as specified and directed. |
| 85 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 86 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 87 | S&F rolled mild steel structural work in rectangular/tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 88 | M&L for precast cement concrete 1:2:4, type B1 (using 20mm graded aggregate) in cover slab and setting in Cement Mortar 1:6, match the joints complete all as specified and directed |
| 89 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½round or ¾ section) in cement concrete 1:2:4, type B1 using 20mm graded stone aggregate, smooth finished and reforming benching as required for internal dia of pipe 150/160mm ball complete all as specified and directed. |
| 90 | M&L for PVC (SWR) pipe 160mm bore single socketed in any length with rubber rings joints or jointed with solvent cement, laid in trenches or in floors complete all as specified and directed. |
| 91 | M&L PCC (1:4:8) type D2 (using 40mm stone aggregate) concrete bed to drain pipe 160 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 92 | Supply, erection, connecting, testing and commissioning of LLDPE modular septic tank of capacity 5500 Ltrs, 2.50 mtr length and 2.20 mtr height with 160 mm dia inlet, outlet pipes vent shaft, plastic manhole cover, etc. designed to carry sewage and sullage water for 30 users including PCC 1:4:8 type D2 foundation/ bed concrete, filling water and back filling with approved earth, make the pipes connections and providing plastic cover slab filled with concrete as per manufacturer\"s instructions etc. complete all as specified and directed. |
| 93 | Excavating in post holes (or similar holes) in hard/ dense soil each not exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering, and removing surplus soil to a distance not exc 50 m and making good surface complete all as specified and directed. |
| 94 | M&L for coloured & polished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors with grey pigment cement and pigments including 20mm thick screed bed in CM 1:4 complete all specified and directed. |
| 95 | Material and labour for laying XLPE insulated, PVC innersheathed, extruded PVC outer sheathed, LT underground cable, armoured with glavanised wire, heavy duty electric cable with stranded aluminium conductor of cross-sectional area 2 core 10 sqmm, 1100 volts grade, as per IS 7098 (Part 1) 1988, laid in trench, fixed on wall/ pole drawn through pipe etc includingof provision of lugs & testing, complete all as specified and directed. |
| 96 | Excavating in trenches in soft/ loose soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables, pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed. |
| 97 | Removing excavated soil material from site to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr from the starting point complete all as specified and directed. |
| 98 | Supply and spreading red soil as earth cushioning to cable by using IS sieve to separate the composite particle/ roots etc. and refilling in trenches and compacted in layers to form a solid bed covering to cable complete all as specified and directed. |
| 99 | Supply and lay in trenches burnt brick sub-class \"B\" of old size for of UG cable protection complete all as specified and directed. |
| 100 | M&L for 40 mm bore medium grade GI tube with all fittings laid along the pole/ in trenches/ under road or floor complete all as specified and directed. |
| 101 | M&L for cutting of road/ hard surfaces for laying LT cables through pipes of any size not exceeding the depth from ground level 35 cm and making good surface as per existing complete all as specified and directed. |
| 102 | S&F 25 mm bore UPVC gate valve/ ball valve with handle complete all as specified and directed. |
| 103 | Cutting existing 40 or 50 mm bore steel tubing for alterations or additions and inserting new tees, branches, etc and connection to 40/ 50 mm bore steel pipe/ valve (Each cut measured) complete all as specified and directed. |
| 104 | M&L for road/ PCC/ chequered tile/ hard surface cutting for laying pipes of any size and making good surface as per existing complete all as specified and directed. |
| 105 | S&F 25 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 including fittings such as bends, elbows, Tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs etc fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 106 | M&L for point wiring complete for one light/ fan/ light/ S/S point controlled by one switch with 1.50 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded, copper conductor concealed in wall through PVC conduit medium grade and conduit accessories of suitable size with modular metal flush boxes of suitable size & modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and directed.Note: Cost of modular metal flush boxes concealed in wall with suitable white cover plate for mounting switches/ sockets, regulators, bell push etc and cost of cutting chases & making good to disturbed surface with cement mortar, if required any shall be deemed to be included in the quoted rate. |
| 107 | All as per SI item No. 106.00 here-in-before, but for one socket outlet, 3 pin 16 Amp on independent board with 4.00 Sqmm FRLS cable and 4.00 sqmm cable earth continuity wire complete all as specified and directed. |
| 108 | S&F modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed. |
| 109 | S&F modular socket 6A/16A - 2/3 pin combined 2 module, flush type complete all as specified and directed. |
| 110 | S&F double door MCB SPN distribution board with steel sheet powder coated DB 4 Ways with 200 amps rated bus bar suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 complete including and making good the disturbed surfaces of walls, floors filling up of holes, plastering, whitewashing/ distempering etc matching to the existing all as specified and directed. |
| 111 | Supply and fixing MCB SPN 32 Amp rating 240V, 10KA \"C\" curve complete all as specified and directed. |
| 112 | S&F MCB SP 6-32Amps breaking capacity 10 KA\"B\" series 240 volts 50 Hz complete all as specified and directed. |
| 113 | S&F modular socket, 6A - 2/3 pin combined 2 module, flush type complete all as specified and directed. |
| 114 | S&F modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed. |
| 115 | S&F ceiling rose, 3 terminals PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 116 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 117 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cabl e of suitable size from ceiling rose complete all as specified and directed. |
| 118 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 119 | S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |