Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface Excavation not exc. 30 Cm deep and ave. 15 Cm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 2 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 3 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed. |
| 4 | Removing excavated Material (Soil) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed. |
| 5 | M&L Hardcore of gauge not exc. 63 mm, broken boulders aggregate deposited, spread andlevelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed. |
| 6 | M&L Earth filling under floors or in founda-tions including watering and consolidation, complete all as specified and as directed. |
| 7 | Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15 cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured). |
| 8 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 9 | M&L for RCC Nominal mix type B1 (1:2:4)( 20 mm graded agg) as in foundation, base for column , plinth beam etc complete all as specified and directed |
| 10 | M&L for RCC Nominal mix type B1 (1:2:4) ( 20 mm graded agg) as in column,post etc complete all as specified and directed |
| 11 | M&L for RCC Nominal mix type B1 (1:2:4) ( 20 mm graded agg)as in roof slab supported on wall, beam, landing, desk slab etc complete all as specified and directed |
| 12 | M&L for Nominal mix type B1 (1:2:4) ( 20 mm graded agg)as Lintel/chajja etc complete all as specified and directed |
| 13 | M&L for RCC Nominal mix type B1 (1:2:4) ( 20 mm graded agg)as Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 14 | M&L PCC (1:3:6) type C-1 as in bed block of hold fast using 20 mm stone aggregate etc complete all as specified and as directed. |
| 15 | M&L Cement Concretetype C2(1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, sub base to floors/path/paving/hardstanding etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 16 | M&L Formwork to Sides of Concrete Founda-tions, Footings, bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of foundation and plinth beams and similar work; Square, rectangular or polygonal, vertical or to batter, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 17 | M&L Formwork toSoffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 18 | M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 19 | Use & waste of formwork to side and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, verhangs etc also plays between floors and beams etc complete all as specified and as directed. |
| 20 | Use & waste of formwork to edge of concrete flats, breks in flooors, openings in concrete walls , floors and roofs and sides of RCC/PCC bands in walls, horizontal or loppin and similar work all exceeding 20 cm wide(Where RCC/PCC band in walls spanning and opening , the formwork soffit only shall be paid for under item 7010 of SSR Part-II, complete all as specified and as directed. |
| 21 | M&L Bands, Straps, Supports or Stays for Rain Water, Ventilating Pipes including Bolts, if required, Hooks (Stay), heavy, for Large Gates; Hook and Pintle Hinges, Large Hasps and Staples; Chains; Hand Made Sliding Bolts; Clamps; Holdfasts; Wall Ties; and Similar Small Articles, conforming to Fe-290 Gde E-165, complete all as specified and as directed. |
| 22 | M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 23 | Mild steel bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 24 | M&L Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 25 | S & F powder coated Anodised aluminiumventilator as in lours, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 26 | S&F Wire netting of galvanised steel wire 1.4mm dia , 25mm mesh size fixed with tinned tacks of stainless steel wire staples complete all as specified and as directed. |
| 27 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 28 | M&L Preparing old Steel Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 29 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 30 | M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 31 | M&L Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry width wise across the line of cable in trenches for protection of UG cable including dismantaling of old unservieacble bricks, complete all as specified and as directed. |
| 32 | M&L Rendering 20mm thick in Cement Mortar on fair faces of brick work or concrete surface of wall in two layer, first layer 10 mm thick in cement morter (1:4) and top layer 10mm thickin cement morter (1:4) using water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and as directed. . (NOTE:-WPC shall be measured andpaid separately) |
| 33 | M&L Rendering15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed. |
| 34 | M&L Rendering 15mm thick in Cement Mortar 1:3 (Externally) on Fair Faces of Brick Walls or on Concrete Surfaces including mixing with WPC as per manufacturer\"s instructions, Plastered Surfaces finished Even and Smooth without using extra Cement, complete all as specified and as directed. |
| 35 | M&L Rendering 5 mm thick in patches with CM (1:3) on ceiling Complete all as specefied and directed. |
| 36 | Supply only water proofing compound. Conforming to IS -2645 complete all as specified and as directed. |
| 37 | M & L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.09 sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of surface over screed Bed or Bedding Layer 15mm thick in Cement Mortar 1:6complete all as specified and directed |
| 38 | S&F Coloured Glazed ceramic tiles 450 x 300 mm x8mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm screeding in Cement mortar 1:4 complete all as specified and directed. |
| 39 | M&L Preparing new Surfaces of Walls andapplying Two Coats of DistemperOil Emulsionover a coat of primer andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 40 | M&L Preparing new plastered surfaces of wall and appplying two coats of acrylic exterior weather coat over acoat of primer withdamp proof care andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and evenas per manufacturer instrcution and applied by approved applicatorcomplete all as specified and directed. |
| 41 | S&F Figured Glass 4.0mm thick, Pin Head / frosted type and glazing with Wooden Beads or Oil Putty in Square or Rectangular, not exc. 0.50 Sqm, complete all as specified and as directed. |
| 42 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as per specified and as directed. |
| 43 | S&F Solid PVCdoor frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, complete all as specified and as directed. |
| 44 | S&F Aluminium anodised barrel tower bolts of extruded section 200 mm long and fixed with screws complete all as specified and as directed. |
| 45 | S&F 150mm long aluminium handle, cast type, anodised complete all as specified and directed. |
| 46 | S&F 100 mm Butt hinges medium weight cold rolled mild steel and fixed with SS screw complete all as specified and as directed. |
| 47 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer\"s instructions, complete all as specified and as directed :-(a) Preparing and cleaning of fully drysurface as per IS:3067-1966.(b) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.50 Litre per Sqm.(c) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.60 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. |
| 48 | S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a pair of Cast Iron Brackets duly painted including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed. |
| 49 | S&F 600mmx450mm bevelled edge mirror of selected quality glass mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass, screws and cup washers complete all as specified and as directed. |
| 50 | S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 1000 Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipe including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. |
| 51 | S&F PTMT Ball Valve 20mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed as in repair, complete all as specified and as directed. |
| 52 | S&F 20 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions, complete as all specified and as directed. |
| 53 | S&F 15 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions, complete as all specified and as directed. |
| 54 | S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with \"p\" or \"s\" trap front or back inletincluding fixing Bolts with and (excluding 10 litre capacity low levelFlushing Cistern)and providing 32mm dia PVC flush pipe including plastic water closet seat with flat botton cover (coloured) fixed with mild steel chromium plated or aluminium hinging device and making good disturbed Surfaces in Cement Mortar 1:3 and fixed, complete all as specified and as directed. |
| 55 | Supply and fix, bowel urinal flat back of size 465 x 355 x 265mm (minimum), white, with grating and union for discharge pipe, (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinals against wall in cement mortar (1:2) securing urinals to plugs with and including 60 mm brass screws and pointing around urinals back in cement complete all as specified and as directed. |
| 56 | S&F White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float and Handleincluding Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed. |
| 57 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and as directed. |
| 58 | S & F Towel Rail 600mm long of chromium plated brass metal fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all specified and as directed.. |
| 59 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed. |
| 60 | S&F Angular Stop Cock 15 mm dia (bore), cast copper alloy, fancy type, chromium plated, screwed down, high pressure,with wall flange screwed for Iron Pipes or Brass Ferrule and fixed, complete all as specified and directed. |
| 61 | Supply and fix, 15 mm bore bib taps(not less than 400 gm), cast copper alloy,cromium plated, fancy type, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 62 | S&F 15mm dia Central hole for Hot and Cold water supply basin mixer, brass chromium plated screwed down for iron pipes,including necessary fittings etc as in repair , complete all as specified and as directed. |
| 63 | S & F 15mm dia GI pipe medium grade, fixed in walls for supporting to false ceilings complete all as specified and as directed. |
| 64 | S & F 20mm dia GI pipe medium grade, fixed in walls for supporting to false ceilings complete all as specified and as directed. |
| 65 | Supply & fixing 25 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar andconnection including fittinglike socket /Union/Tee/Reducer Nipple etc complete all as per specified and directed. |
| 66 | S & F 40mm dia GI pipe medium grade, fixed in walls for supporting to false ceilings complete all as specified and as directed. |
| 67 | S&F Pipes galvanized,50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified. |
| 68 | Supply & fixing 50 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar andconnection including fittinglike socket /Union/Tee/Reducer Nipple etc complete all as per specified and directed. |
| 69 | S&F 25 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions, complete as all specified and as directed. |
| 70 | S&F 50 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions, complete as all specified and as directed. |
| 71 | Supply and fix, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 72 | Supply and fix, 110 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 73 | S& F 75 mm dia PVC (SWR) bends any radius fixed in any position, complete all as specified and directed |
| 74 | S& F 110 mm dia PVC (SWR) bends any radius fixed in any position, complete all as specified and directed |
| 75 | M&L for supply, laying, jointing and testing salt glazed stone ware drain pipe, grade \"A\" 150mm bore (internal dia) laid in trenches on concrete bed to required slope jointed and tested complete all as specified and directed.(Note:- Excavation/earth work and concrete bed shall be measured and paid for separately) |
| 76 | M&L plain cement Concrete 1:3:6 type C2(Using 40mm graded agg) for concrete bed to drain pipes of 150mm bore, under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed by Engineer-in-Charge |
| 77 | S &F chequered cement concrete coloured tiles (glossy finish) 20cm x 20cm x 25 mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment over Screed Bed or Bedding Layer 15mm thick in Cement Mortar 1:6,complete all as specified and directed. |
| 78 | M&L Pre polishedkerb stone factorymade fabricated of any pattern and design & size M-25 grade cement concrete inposition to required line, level and curvature with cement mortar 1:3 including making joints with or without groves (Thickness of joint except at sharp curve shall not be more than 5mm) including making drainage opening wherever required complete all as specified and as directed. |
| 79 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, complete all as spcified and directed. |
| 80 | M&L Preparing new surface of brick / concrete/ stone surface (road kerb stone)of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat ofPrimer, complete all as specified and as directed. |
| 81 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(ii) cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. |
| 82 | All as per item No. 81 above but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and as directed. |
| 83 | All as per item No. 81 above but for 5 Amps socket point on the same board controlled by one switch. |
| 84 | M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one wayswitch using4.0 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, suitable for metal flush box, modular cover plate with frame of suitable size of 3M and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed. |
| 85 | S&F Modular switch flush type, 6 Amp, one way ,1 module complete all as specified and as directed. |
| 86 | S&F Modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and as directed. |
| 87 | S&F Modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and as directed. |
| 88 | S&F Modular switch 1 way 16A, 1 moduleupply and fix Modular switch one way 16 Amp complete all as specified and as directed. |
| 89 | S&Fceiling rose surface backelitethree terminals complete all as specified and as directed. |
| 90 | Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed. |
| 91 | Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed. |
| 92 | Supply and fixing modular metal flush box 3 modules complete all as specified and as directed. |
| 93 | Supply and fixing modular metal flush box 6 modules complete all as specified and as directed. |
| 94 | Supply and fix LED tube light fitting of 18 W with tube (4 Ft) 240 V Wall mounted LED batten polycarbonate houseing and integrated electronic driver with high efficient LEDs 18 Watt with acessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories internally pre-wired and inclg connection complete all as specified and as directed. |
| 95 | Supply and fix LED tube light fitting of 9W with tube (2 Ft) 240 V Wall mounted LED batten polycarbonate houseing and integrated electronic driver with high efficient LEDs 18 Watt with acessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories internally pre-wired and inclg connection complete all as specified and as directed. |
| 96 | S&F LED fittings with lamps of 30 watts for bldg security light IP 66 power Coated pressure die cast aluminium compact high power LED street light with compact size & rough design 32 mm GIBendincludingtaking down old unserviceable one complete all as specified and as directed. |
| 97 | Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and as directed. |
| 98 | Supply and fixed MCB SP,6 to 32 Amps, \"C\" series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. |
| 99 | Supply and fixed MCB SPN 6-32 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. |
| 100 | M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. |
| 101 | M&L Earthing complete with GI pipe electrode, 40mm bore, medium grade, 2.5m length burried directly in ground vertically with top edge not less than 1.25 m below ground level connected to galvanised iron earth strip 32x6 mm by means of bolts, nuts,check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steelbars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 4 of MES Schedule Part I and testing complete inclduing taking down old one complete all as specified and as directed. |
| 102 | S & F ventilating exhaust fan300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size, complete all as specified and as directed. |
| 103 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed. |
| 104 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core. Note:1. Excavation and earth work will be measured and paid seperately. |
| 105 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm, 3.5 core. Note:1. Excavation and earth work will be measured and paid seperately. |
| 106 | S&F Air termination aluminium single pointed rod 12 mm dia, 300 mm long including takuing down old one complete all as specified and directed. |
| 107 | Supply and fix aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip complete all as specified and as directed. |
| 108 | S&F GI strip of size 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including takuing down old one complete all as specified and directed. |
| 109 | Supply , install, testing and commissioning of floor mounted LT outdoor panel board AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessoriestotally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick with CPRI Approved CRCA steel sheet of suitable Size with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , completeall as specified and directed:-BUSBAR :-(a) Copper bus bar 200 Amps , supported on non hygroscopic fibres and brass screws for mounting -04 NosINCOMER (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 80 Amps with Fixed thermal and Fixed magnetic setting - 01 NoINDICATING DEVICES :- (a) Supply and fixing LED Indicating lamps for Main Supplyindicating R, Y, B - 03 Nos(b) Supply and fixing Digital Ampere Meter 31/2 digit display , incl CT having CTR 80/5 - 01 Nos & Digital Voltmeter 0-500 Volts , SIF 96 - 01 NosOUTGOING FEEDERS :- (a)Supply and fixing MCCB of 4pole , 415volts of capacity 63 ampswith breaking capacity of 16 KAFixed thermal and fixed magnetic setting - 02 No (b) Supply and fixing automatic star delta strater for 15 HP- 02 Nos |
| 110 | S&F Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw including takuing down old one complete all as specified and directed. |
| 111 | Supply, fixing testing and commisioining of Monoblock booster pump set suitable for 415 V, 3 phase system having discharge capacity 750 LPM at 40 mtr head of 15 HP/11 KW, with chrome steel impeller, electric driven 415 V, TP complete all as per specified and directed. |
| 112 | M&L DI pipe of 100 mm bore with spigot and socket end rubber gas cate joint(titon) centrifugally cast class k-7 conforming to IS 8329-2000 laid in trenches/ on surface/ over masonry pillar and connection to new position, Cost of joint included in the qoted rate, complete all as specified and as directed. |
| 113 | Supply, Installing and testing cast iron sluice valve, 150 mm bore class PN-1.6, ISI marked conforming to IS-14846 complete with flanged ends duly drilled, brass spindle, CI gate with brass rings and iron wheel head including dismantling unserviceable sluice valve and removing from site of work complete all as specified and as directed. |
| 114 | Supply, Installing and testing cast iron sluice valve, 100 mm bore class PN-1.6, ISI marked conforming to IS-14846 complete with flanged ends duly drilled, brass spindle, CI gate with brass rings and iron wheel head including dismantling unserviceable sluice valve and removing from site of work complete all as specified and as directed. |
| 115 | S&F 100mm bore Cast iron non return valvedouble flanged (class-\"B) high pressure conforming to IS-5312 ete with nuts, bolts & washer gaskets etc including taking down the old unserviceable one complete all as specified and directed. |
| 116 | S&F CI /DI bends (any type radious & angle) tapers any type (strain out bend) increasingdecerising or double socket etc Tee pieces (single branch) junction double brash cross collars (flanged or socket & spigot suitable for upto 150mm DI/CI pipe after taking out the old unserviceable one complete all as specifed and directed. |
| 117 | NOTES:1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule \"A\" notes for details. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail