| 1 | Demolition of cement concrete (unreinforced) of any description and in any postion not otherwise specifically provided etc (below or above ground level)/sunken floors / roof pading etc and removing debris out side MD land complete all as specified and as directed. |
| 2 | M&L Providing40mm thick cement concrete type B0, 1:2:4 using 12.5 mm graded stone aggregate .as in floors for levelling course and as in padding concrete on roof mixed with WPC of approved make where necessary all as directed. Note: WPC will be measured and paid separately. |
| 3 | M&L for laying 3mm thick APP modified water proofing membrane weighing not less than 3.6 Kg/Sqm, reinforced with non woven polyster matt black finished weighing not less than 100 gm/Sqm having softening point not less than 140 degree celsius longitudinal tensile strength not less than 300 N/Sqm, minimum overlapping 10 cm on either side and 15 cm on ends lap over a coat of bitumen primer @ 0.20 Kg/Sqm and finished with aluminum paint @ 0.10 Ltr/Sqm all as per manufactures instruction and as directedNote : The work shall be carried out by authorised applicators of manufactures. |
| 4 | M & L 20mm thick cement screed in cement mortar 1:3 mixed with liquid water proofing compound FOSROC\"s complast 421 IC @ 130ml per bag of cement including a bonding coat of FOSROC\"s Nito bond AR cement slurry for roof slab/ floor complete all as specified (liquid water proofing compound are measure seperately) |
| 5 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, and removing debris out side MD land complete all as specified and as directed. |
| 6 | Material and labour for rendering 15 mm thick in Cement Mortar 1:4 mixed with liquid water proofing compound as per manufacturers\" instructions on stone masonry surfaces of wall, finished even and smooth without using extra cement completeall as specified and as directed. Note: Liquid water proofing compound shall be measured and paid separately. |
| 7 | Supply only liquidwater proofing compound of approved makecomplete all as specified and as directed. |
| 8 | M & L for Providing, cement concrete 1:3:6,type C-1 (20mm graded aggregates) in bed blocks /parapet walls benching, including weathering, slightly rounded or chamfered angles and throating, all as specified and directed. |
| 9 | S & F in repairs PVC tank cover for 500 /1000 Ltrs capacity complete. |
| 10 | Demolition of brickor stone/ boulder masonary, built in cement mortar and removing debris out side MD land complete all as specified |
| 11 | M&L Precast cement concretetype C1 1:3:6 (Using 20 mm gradedaggregate) block masonrywith solidblocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 12 | M&L Preparing newly plastered surfaces of external walls and applying exterior wall putty of 1 mm thick for smoothness, one coat of exterior wall primer and two coats of Exterior Emulsion anti fungal weather proof paint APEX ULTIMA OF Asian Paint or WEATHER COAT SMOOTHof Berger complete all as per manufacturer instruction as directed. |
| 13 | M&L Preparing old plastered surfaces of external wallsand applying exterior wall putty of 1 mm thick for smoothness, one coat of exterior wall primer and two coats of Exterior Emulsion anti fungal weather proof paint APEX ULTIMA OF Asian Paint or WEATHER COAT SMOOTHof Berger complete all as per manufacturer instruction as directed. |
| 14 | M&LPCC 1:4:8 type D2 with 40mmgraded stone aggregateas in sunken floor/toilet floor /kitchen floor/tank base concrete finished the surfaces even and fair to receive top layer all as specified and as directed. |
| 15 | M&L 100mm thick PCC 1:4:8 type D2 (40 mm graded aggregate) as in floor concrete finished even and rough to receive the top layer all as spcified and as directed. |
| 16 | M&L 75mm thick Plain Cement Concretetype C-1, 1:3:6 (20mm graded stone aggregate)as in floors, plinth protection etc. finished even & fair without using extra cement complete as specified and as directed. |
| 17 | Dismantling existing tanks exc. 250 lit & n. exc. 500 litres capacity, removing off the site complete all as specified and as directed. |
| 18 | Dismantling existing tanks exc. 500 lit & n. exc. 1000 litres capacity, removing off the sitecomplete all as specified and as directed. |
| 19 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position of size exc 500 ltr but n.exc 1000 ltr. |
| 20 | Supply and Fix, 1000 litres capacity triple layered Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks,(Cylindrical vertical with closed top) screwed lid type conformingto IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) complete all as specified and as directed. Make: Sintex/Polycon/Vectus. |
| 21 | Supply and Fix, 500 litres capacity Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, three layered (Cylindrical vertical with closed top) screwed lid type conformingto IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009)etc., complete all as specified and as directed. |
| 22 | S&F 25mm bore, Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed,weight 455 gms complete as specified and as directed. |
| 23 | S&F in Repair 25mm bore, Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete as specified and as directed. |
| 24 | S&F in Repair20mm bore, Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete as specified and as directed. |
| 25 | Taking down steel tubing and connections of 15 mm bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 26 | Taking down steel tubing and connections of 20 mm bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 27 | Taking down steel tubing and connections of 25 mm bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 28 | S&F 15 mm bore Galvanised iron tubing, medium grade, with all fittings laid in trenches, floors or fixed to walls etc complete all as specified and as directed. |
| 29 | S&F 20 mm bore Galvanised iron tubing, medium grade, with all fittings laid in trenches, floors or fixed to walls etc complete all as specified and as directed. |
| 30 | S&F 25 mm bore Galvanised iron tubing, medium grade, with all fittings laid in trenches, floors or fixed to walls etc complete all as specified and as directed. |
| 31 | Refixing of old GI steel tubesand connections after cleaningof 15 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed. |
| 32 | Refixing of old GI steel tubesand connections after cleaningof 20 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed. |
| 33 | Refixing of old GI steel tubesand connections after cleaningof 25 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed. |
| 34 | Cutting chases, pinning in, making good to facings where required & pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; & cutting chases for concealed water tubing or concealed conduit wiring, etc.& making good, cutting not exc 10 cm grithin brick wall |
| 35 | M&L for Plain cement concerte1:2:4 type B1 using 20 mm graded stone aggregate as in benching to chajjas/parapet wallsetc., |
| 36 | Dismantling single layer mangalore pattern or similar tiles in roofing and removing debris out side MD land complete all as specified and as directed. |
| 37 | M&L Roof tiles, Mangalore pattern,interlocking at side joints, laid in cement mortar complete all as specified. |
| 38 | Fixing only roof tiles mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed. |
| 39 | M & L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 |
| 40 | All as per item No. 38 here-in-before but exept tiles |
| 41 | Dismantling battens for tiles, shingles etc of any size including tilting fillets. |
| 42 | S&F for 2nd class hardwoodtile battens clean sawn witrh sectional area exc 15 sqcmbut n exc 25 sqcm at 30 cm centres complete all as specified and directed. |
| 43 | All as per item No. 41 here-in-before but except battens |
| 44 | Dismantling of unframedtimber scantlings 40 sq. cm and over in section, in any position tile battensas in roofing and removing debris out side MD land complete all as specified and as directed. |
| 45 | S&F for 2nd class hard-woodscantlings clean sawn timber framed and fixed as in roof members complete all as specified and directed. |
| 46 | Dismantling boarding, any description, fixed in any position with nails and removing debris out side MD land complete all as specified. |
| 47 | S&F for 20mm thick 2nd class hard wood boarding, supplied and fixed with nails in any situation (except flooring and skirting) complete all as specified and directed. |
| 48 | M & L for preparation of new painted surfaces of wood and wood based materials of any description not other wise described over 10 cm width or girth and applying Two coat of synthetic enamel paint over a pink primer coat complete all as specified and directed. |
| 49 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified. |
| 50 | S&F for 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 275,in pache, all as specified and directed. |
| 51 | Fixing only 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 275 all as specified and directed. |
| 52 | S&F in repairs for pre-painted Galvalume aluminium Zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 53 | Fixing onlypre-painted Galvalume aluminium Zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 54 | S&F in repairs for pre-painted Galvalume aluminium Zinc coating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 55 | Fixing only pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 56 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line overall as fixed along the centre line over fittings and accessories) Note :-Rate for fixing the gutter upto 10mtr height deemed to be included in quoated rate by the contractor. |
| 57 | S & F in repair PVC half rounded gutter dia 250 mm (CL-2) (6 kg/cmsq) all as specified and as directed.Note :-Rate for fixing the gutter upto 12 mtr height deemed to be included in quoated rate by the contractor. |
| 58 | Fixing Only PVC half rounded gutter dia 250mm (CL-2) (6 kg/cmsq)fixed with suitable MS brackets all as specified and as directed.Note :-Rate for fixing the gutter upto 12 mtr height deemed to be included in quoated rate by the contractor. |
| 59 | S & F in repair PVC half rounded gutter dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq)all as specified and as directed. |
| 60 | Fixing Only PVC half rounded gutter dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq)all as specified and as directed |
| 61 | S & F in repair PVC Pipe dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq) fixed with suitable MS brackets vertical surface of wall all as specified and as directed |
| 62 | Fixing Only PVC Pipe dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq) fixed with suitable MS brackets vertical surface of wall all as specified and as directed |
| 63 | S&F in repair PVC bends 160mm dia all as specified and as directed. |
| 64 | S&F in repair PVC bends 250mm dia all as specified and as directed. |
| 65 | S&F in repair 160mm dia PVC half rounded gutter(Single `T\") equal or unequalall as specified and as directed. |
| 66 | S&F in repair 160mm dia PVC endsall as specified and as directed. |
| 67 | S&F in repair 250mm dia PVC half rounded gutter(Single `T\") equal or unequalall as specified and as directed. |
| 68 | S&F in repair 250mm dia PVC endsall as specified and as directed. |
| 69 | S & F in repairs 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches/ walletc complete.(6 Kg/ cm Sq). |
| 70 | Fixing only for 110mm diaPVC (SWR) pipes single socketted, in any length with rubber ring joints, fixed to walls with suitable MS clamps. |
| 71 | S & F in repairs 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches/ wall etc complete .(6 Kg/ cm Sq). |
| 72 | Fixing only for 75mm diaPVC (SWR) pipes single socketted, in any length with rubber ring joints, fixed to walls with suitable MS clamps. |
| 73 | Dismantling of structural steel work including door ,gates, framed truss, rafter,purlins etc |
| 74 | S & F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged intospikes; framed guard bars; barred iron doors ladders framed balusters; walk ways railings ; framework of water tanks and similar work confroming to Fe 410-0 or Fe 310-0 all as specified and directed. |
| 75 | S&F Rolled mild steel works such as in main and cross beams, hip and jack rafters, purlins, angle cleats or other connecting plates, as in rain water gutter clamps etc. conforming to Fe-410-W(Gde E-250) quality-A |
| 76 | M&L steel work in tubularpost,trusses including special shaped washer etc..complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade E-250 all as specified. |
| 77 | M&L forPreparation ofnew/previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. |