| 1 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth for foundation, cesspits, manholes laying of cables/ pipes etc. and getting out in any type of soil complete all as specified and direcetd. |
| 2 | M&L for PCC 1:4:8 type D-2 using (40mm fraded aggregate) in foundation, filling and mass concrete, complete all as specified and direcetd. |
| 3 | M&L for Reinforcement cement concrete (Design mix) type B-1 (1:2:4) (20mm graded stone aggregate) as in foundations, footings of columns etc complete all as specified and direcetd. |
| 4 | All as per Srl item No. 3.00 above but for columns complete all as specified and direcetd. |
| 5 | All as per Srl item No. 3.00 above but for plinth beam, Roof beams and lintels/ Chajjas complete all as specified and direcetd. |
| 6 | M&L for MS TMT bars 10mm dia and over out to length, bent to shape required, including cranking, bending including necessary welding as required & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with the clips complete all as specified and direcetd. |
| 7 | M&L for MS TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending including necessary welding as required & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with the clips complete all as specified and direcetd. |
| 8 | All as per Srl item No. 7.00 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders/ tempreture bar etc including other works, complete all as specified and direcetd. |
| 9 | Use and waste form work to sides of concrete foudations, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or tobatte for flat and rough finished surfaces of concrete complete all as specified and direcetd. |
| 10 | Use and waste form work to sides of columns, pillars posts struts for flat and rough finished surfaces of concrete complete all as specified and direcetd. |
| 11 | Use and waste form work to sides of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for flat and rough finished surfaces of concrete complete all as specified and direcetd. |
| 12 | Returning filling in including speading, leveling, watering and well ramming in layer complete all as specified and direcetd. |
| 13 | M&L for removal of excavated Soil to a distance n exc 50m and depositing where, complete all as specified and direcetd. |
| 14 | S&F Steel work in tubular trusses (Square/ rectanguler) including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1239 Part-1 and 2 grade St.-240, complete all as specified and direcetd. |
| 15 | S&F of rolled mild structural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and direcetd. |
| 16 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachmentconforming to Fe 410-W (Gde-E-250) quality-A. etc. complete all as specified and direcetd. |
| 17 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in widht or girth and applying two coats of synthetic enamel paint over a coat red oxide, zinc chrome primer complete all as specified and direcetd. |
| 18 | S&F Mild steel screw bolts (machine made) with hexagonal/ square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 22.5cm & n exc 30cm long dia of shank 16 to 20mm.etc. complete as directed. (Contractor will take due care for its threads and rusting by applying grease and cotton waste). |
| 19 | S&F pre painted galvalume aluminum zinc coating GI based crrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws/ J hooks including flat iron wind ties complete all as specified and direcetd. |
| 20 | S&F pre painted galvalume aluminum zinc coating GI based Plane steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws/ J hooks including flat iron wind ties complete all as specified and direcetd. |
| 21 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 using modular size bricks complete all as specified and direcetd. |
| 22 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in half brick thick walls in CM 1:6 using modular size bricks complete all as specified and direcetd. |
| 23 | M&L for 15mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even and smooth without using extra cement, complete all as specified and direcetd. |
| 24 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete surfaces finished even and smooth without using extra cement, incl provn of chicken wire mesh of 100mm width to the RCC & Bk wall joints all as specified incl mixing with water proofing compound as per manufacturers instruction complete all as specified and direcetd. (Note:- WPC shall be measured and paid separately). |
| 25 | Supply only liquid water proofing compound complete all as specified and direcetd. |
| 26 | M&L for preparation of new surfaces of plastered of walls and applying two coat of distemper oil emulsion incl priming the surface and incl one coat of wall putty complete all as specified and direcetd. |
| 27 | M&L for newly plastered surfaces and applying two coat of Premium Acrylic smooth exterior paint and including priming coat of exterior primer and incl one coat of wall putty complete all as specified and direcetd. (Note : Rate shall be included for necessary scaffolding and safety measures where required at site and painting will be done by brush/ spray/ roller). |
| 28 | S&F Pressed steel door frame for single door, size 105 x 60 x 1mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, holdfast (size 25mm x 3mm) of length 30 cm) etc., including Cutting holes in brick walls built in cement mortor for inserting holdfasts and making good dismantled portion in cement mortor 1:3 or cement concrete 1:2:4 Type B-1, depth of embedded portion of holdfasts exc. Half brick but not exc. One brick from the face of the jamb intl the wall complete all as specified and direcetd. |
| 29 | M&L for PCC 1:2:4 type B0 (12.5mm graded) aggregate for filling in pressed steel door framed complete all as specified and direcetd. |
| 30 | M&L for Steel door including projecting type hinges, steel handle, locking system, complete, with glazing bars, dovetailed or welded complete all as specified and direcetd. |
| 31 | S&F of Powder coated aluminum threetrack sliding shutters consisting two Glazed shutters and one guazed shutters (with wire mesh), each shutter width one half of the length of window with the following specifications and making good the adjacent surfaces with brick work and plaster as required at site:-(i) Three way track for sliding shutters of cross section 91.80mm x 31.75mm x 1.30mm thick.(ii) Sliding shutter frame of cross section 40 x 18 x 1.30mm.(iii) Aluminium glazing strip of size 18.2 x 16.66mm.(iv) 4 to 5mm thick float glass superior quality make Modi float for two shutters.(v) IDPE rubber gasket for fixing glass.(vi) Locking cleat concealed per shutter - 01 No.(vii) Two nos sliding rollers per shutter.(viii) Rubber shock absorber 03 No per shutter.(ix) Aluminium wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm for one shutter.(x) Fixing screws for frame with wall - 06 No per window. |
| 32 | S&F of Steel rolling shutters, 1mm thick lathing, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:push pull or manual type, complete all as specified and direcetd. |
| 33 | S&F of Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and direcetd. |
| 34 | M&L for 4mm thick sheet glass, ordinary quality and glazing with oil putty and fitted in wooden/ steel window in square n exc 0.5 Sqm in each pane. complete all as specified and direcetd. |
| 35 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed. |
| 36 | S&F of Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and direcetd. |
| 37 | M&L for broken stone or boulders hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a floor/ true surface complete all as specified and direcetd. |
| 38 | M&L for 100mm thick PCC type D-2 1:4:8 (40mm graded stone aggt) in sub base of floor complete all as specified and directed. |
| 39 | M&L for 50mm thick PCC type B-2 1:2:4 (20mm graded stone aggt) in top layer of floor to be finished even and smooth with using extra cement complete all as specified and directed. |
| 40 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 41 | All as per Srl item No. 40.00 above but on vertical surfaces such as skirting incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed. |
| 42 | M&L for PCC 75mm thick type C-2 (1:3:6) (using 40mm graded stone aggregate) in plinth protection, joints should be filled with bitumen primer etc, complete all as specified and direcetd. |
| 43 | M&L for Treating the top surface of the filled earth @ 5.00 ltr of emulsion per Sqm of surface area with ATT complete all as specified and direcetd. |
| 44 | M&L for Treating the soil along with internal periphery of room at the rate of 2.25 litre of emulsion per metre of surface area with ATT complete all as specified and direcetd. |
| 45 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and direcetd. |
| 46 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and direcetd. |
| 47 | S&F of PVC rain water gutter having size of 150mm dia pipe and fixed at walls/ roof purlins with help of MS bracket at spacing of 1000mm including PVC reducer of 150 to 110mm dia for water collection at the ends at any height and inclusive of scaffolding complete all as specified and direcetd. |
| 48 | S&F of 110mm dia PVC pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls with clamps complete all as specified and directed. (Note : Rate of necessary scaffolding upto any height will be included in quated rate) |
| 49 | M&L for point wiring (concealed type) complete with FRLSH PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and including cutting/ chasing on brick wall not exc. 10 cm girth (excluding ceiling surface) and supply and fixing PVC conduit pipe medium grade of nominal size 20mm dia along with modular flush box with earth dolly dully, covered with modular white cover plate with inner frame sutaible for modular switchs/ sockets and blank plate of suitable size with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and treated surface with complete all as specified and directed and suitable for the following:- |
| 50 | (i)One light point or one fan point controlled by one, 1- way switch |
| 51 | (ii)One 3/5 pin socket modular outlet, 6 Amp on the same board with other switches |
| 52 | (iii)One 3/5 pin, 5/6 Amp socket outlet point on independent board controlled by one, one way 5/6 Amp switch |
| 53 | All as per Srl item No. 49 here in before but point wiring using 2.5 Sqmm FRLSH PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet, suitable for 16 Amps “independent board”. |
| 54 | Supply & fixing ISI marked modular switch flush button type, single pole, one way, 6 Amps, 240 volts for point wiring complete all as specified and directed. |
| 55 | Supply & fixing modular socket out let 6 pin, 6 Amps flush type for point wiring complete all as specified and directed. . |
| 56 | S&F switch modular type 15A, 1 module complete all as specified and directed. |
| 57 | S&F socket modular type multipurpose 6/16 A, 2 module complete all as specified and directed. |
| 58 | Supply & fixing ceiling rose 3 pin/ PVC/ polycarbonate, isolated body with colour ring for fan point wiring complete all as specified and directed. |
| 59 | Supply and fixing exhaust fan,steel body AC single phase. 230V of size 300m sweep with, blades, and frame and louvers and complete all as specified and directed. |
| 60 | Supply and fixing building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket for street light made out of 40mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/ wall with and including 50 x 6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete. |
| 61 | Supply & fixing batten/ angle holder with colour ring for light point complete all as specified and directed. |
| 62 | Supply, fixing, connecting & testing FTL fitting with high lumen LED batten tube light of 18 Watt having 2100 lumen output with integral/in built driver along with fixture complete all as specified and directed. |
| 63 | M&L for Earthing complete with GI earth plate electrode 600 x 600 x 6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/ loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR Part-1 and connected to the earth point and testing complete all as specified and directed. |
| 64 | Supply & fixing DB with single phase & neutral MCB Distribution Box of 8 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed. |
| 65 | Supply & fixing MCB SP 6-32 Amps 230 Volts,10KA \"B\" series complete all as specified and directed. |
| 66 | S&F MCB single pole & Neutral, 32 Amps rating, 240 volts, \"C\" series, 10 KA breaking capacity & making connection complete all as specified and directed. |
| 67 | S&F MCCB VTPN DB 4 Way (F1+12) double door with 200 Amps rated bus bar, 430 volts, 50 Hz including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc and making good of disturbed surface to match with existing colour of wall complete all as specified and directed. |
| 68 | S&F MCCB 4 Pole, 415 voltsin the existing panel/ location and connection with using aluminum lugs complete all as specified and directed for 63 Amp ratin,16 KA breaking capacity |
| 69 | M&L for sub main wiring with 02 runs of 4 Sqmm main wire along with 01 run of 04 Sqmm earth wire with FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core, 1100 Volts grade along with FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands) in green colour as continuous earth wire conforming to IS 694 with latest amendments and ISI marked, PVC concealed (medium grade) and making incoming/ outgoing electric connections by using required size copper lugs/ thimbles, making good to disturbed surface to match with existingcomplete all as specified and directed. Note:- Two run of main copper conductor, one run of earth wire and one run of pvc conduit shall be mearured as one unit length. |
| 70 | S&F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed. |
| 71 | Supply and fixing ceiling fans complet with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specfied and directed. |
| 72 | Supply & laying 25Sqmm 3.5 core cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable & wrapping pvc tape over XLPE insulation cable and testing complete all as directed. (Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid seperately) |
| 73 | M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed. Note:- Punned thickness 18 cm shall be measured only. |
| 74 | Supply and laying sub class \"B\" bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed. |