| 1 | Material & Labour for light/Fan Point wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 2 | All as per item No. 1 here in before but for one 3 pin socket outlet 5/6 Amps three pin controlled by one switch on independent board complete all as specifieddirected. |
| 3 | All as per item No. 1 here in before One 3 pin socket outlet, 5/6 Amps on the same board with other switches, with cables 1.5sq. mm size complete all as specified and directed. |
| 4 | All as per item No. 1 here in before but for one 5 pin socket outlet 15/16 Amp and 5/6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire withPVC boxes complete all as specified. |
| 5 | All as per item No. 1 here in beforeone light point controlled by two two-way switch 5/6 Amp complete all as specified and as directed . |
| 6 | All as per item No. 1 here in beforeone bell/buzzer point controlled by one bell push complete all as specified and as directed . |
| 7 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5/6 Amp, 240 Volts complete all as specified & directed. |
| 8 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 15/16 Amp, 240 Volts complete all as specified & directed. |
| 9 | S&FSocket outlet2 in 1, 5 pin, 5/6amp flush type |
| 10 | S&FSocket outlet 2 in 1, 5 pin, 5/6 and 15/16 amp flush type |
| 11 | S&F Switch socket combination outlet 2 in 1, 5 pin, 5/6 and 15/16 Amp flush type universal complete all as specified and directed. |
| 12 | S&F Switch socket combination outlet2 in 1, 5 pin, 5/6 Amp flush type universal |
| 13 | Switch socket combination box type 5 pin 5/6 Amp |
| 14 | Switch socket combinationbox type 5 pin 6/16A |
| 15 | Supply and fixing in replacement of ceiling rose, surface bakelite, 65mm x 50mm ,two to three terminals complete all as specified & directed. |
| 16 | S&F bell/buzzer push 5/6 Amp,flush type complete all as specified & as directed. |
| 17 | S&F call bell ding dong electric AC, 240 volt, 50 HZ, surface type complete all as specified & as directed. |
| 18 | Supply & fixing Modular switch 1 way 6A,1 module, 240 Volts complete all as specified & directed. |
| 19 | Supply & fixing Modular switch 1 way 16A,1 module, 240 Volts complete all as specified & directed. |
| 20 | Supply & fixing Modular Socket, 6A - 5 pin combined 2 module, 240 Volts complete all as specified & directed. |
| 21 | Supply & fixing Modular Socket 6A/16A - 5 pin combined 2 module, 240 Volts complete all as specified & directed. |
| 22 | S&F modular White cover plate with frame 02 module |
| 23 | S&F modular White cover plate with frame 03 module |
| 24 | S&F modular White cover plate with frame 06 module |
| 25 | S&F modular Metal flush box 1/2 module |
| 26 | S&F modular Metal flush box 3 module |
| 27 | S&F modular Metal flush box 6 module |
| 28 | Supply and fixing LED light fitting 4 feet (Cool White) 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 29 | Supply and fixing LED light fitting ( Warm White ) 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 30 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 31 | S&F in replacement LED tube rod 4 feet,20 watt 220 V AC Complete all asspecified & directed. |
| 32 | Supply and fixing of batten suitable for fixing LED lights 20 Watt,220V, ACwith holderconnecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 33 | S&F Downlighter round 18 W (White/Warm White) recess mounting type & Driver incl integrated electronic driver including taking down old unsv one complete all as specified and directed |
| 34 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, (Cool White) Surface mounting type with high efficiency PMMA diffuser soft glare free light of colour white/warm white as per requirement at site complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 35 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, (Warm White) 220 V AC Surface mounting type with high efficiency PMMA diffuser soft glare free light of colour white/warm white as per requirement at site complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 36 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, (Cool White) 220 V AC recessed mounting type with high efficiency PMMA diffuser soft glare free light of colour white/warm white as per requirement at site complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 37 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, (Warm White) 220 V AC recessed mounting type with high efficiency PMMA diffuser soft glare free light of colour white/warm white as per requirement at site complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 38 | S&FLED lamp 5 Watt, 230W, B-22, PF not less tha0.85 (min). |
| 39 | S&FLED lamp 9 Watt, Cool White/Warm White,230W, B-22 , PF not less tha0.85 (min). |
| 40 | S&F LED lamp 12 Watt, Cool White/Warm White, 230W, B-22 ,PF not less tha0.85 (min). |
| 41 | S&F of new generation energy saving and environmental friendly long life LED building securitylight made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete all as specified and directed. |
| 42 | S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. |
| 43 | S&F in repair Supply and fixing post top lantern LED type 20watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lampcomplete all as specified and directed. |
| 44 | S&F decorative garden light pressure die cast powder coated housing with PC diffuser efficient high output LED with IP 65 protecton of capacity 10 watt (CDL/WW) with all accessories and including connection up with twin core twisted with flexible copper conductor cable suitable size of 230 volts 50 Hz complete all as specified and directed. |
| 45 | Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade,of size 25 sqmm 4 core as per IS 7098 Pt-IIlaid in trenches / ducts / encased in GI pipe / fixed to polecomplete all as directed andspecified. |
| 46 | Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade,of size 16 sqmm 4 core as per IS 7098 Pt-IIlaid in trenches / ducts / encased in GI pipe / fixed to polecomplete all as directed andspecified. |
| 47 | S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 16 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections . |
| 48 | Description all as per item No. 45 above but one twin core cable flat or circular of size 10 sqmm |
| 49 | Description all as per item No. 45 above but one twin core cable flat or circular of size 6 sqmm |
| 50 | Description all as per item No. 45 above but one twin core cable flat or circular of size 4 sqmm |
| 51 | Supply and fix sheet metal enclosures for DBs double door when MCBs to be used 230 volts 4 way 100 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 52 | Supply and fix sheet metal enclosures for DBs double doorwhen MCBs to be used 230 volts 8 way 200 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 53 | Supply and fix sheet metal enclosures for DBs double doorwhen MCBs to be used 230 volts 12 way 200 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 54 | S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 Vcomplete all as specified and directed. |
| 55 | S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 Vcomplete all as specified and directed. |
| 56 | S&F MCB TPN 63 Amps 240 Vcomplete all as specified and directed. |
| 57 | S&F MCB TP 40 Amps 240 Vcomplete all as specified and directed. |
| 58 | S & F in replacement of MCCB,04 Pole, capacity 63/100 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 59 | S & F in replacement of MCCB,04 Pole, capacity 125 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 60 | S & F in replacement of MCCB,04 Pole, capacity 160 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 61 | MCCBDB\"s VTPNtype double door in wall / nitchwhen MCBB\"s ,to be used Fourpole and neutral, 8way,415 Volt withrated Bus bar ,Suitable for Flush Mounting and Surface Mounting with 160 Amps Copper Bus bar for each phase and 2 Neutral bar, 2 Earth bar,and Cable ties for cable managent,Fully insulated busbar and shrouded Neutral bar ,improved Panassembly for ease of installation ,Prefitted masking sheet, Reversible Door for IP 43 &IP 54 DB\"s with provisionfor DPX3 160 MCCBasincomer, andTPN /SPN/DP/SPout going. Complete all as specified and directed.IP :54 Protection |
| 62 | Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out in any type of soil complete all as specified and as directed. |
| 63 | Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 64 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 65 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning. |
| 66 | Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm,factory madeof specified make , complete all as specified and directed. |
| 67 | Supply and laying galvanised tube light gradeISI marked of size 40 mm dia incl all fittingsin trenches/fixed on pole/wall/floor or laid in positionincluding repairing of demolished cemented portion complete all as specified and directed. |
| 68 | Supply and fix in replacement electronic meters Single phasetemper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. |
| 69 | Taking down of defective geyser of any capacity from different locations for repair including removing of electric connection, pipe fitting without any damage and refixing the same after repair in same/desired location complete all as specified & directed. Note :- The parts required for repair shall be measured separately under relevent item of Sch \"A\" |
| 70 | S&F copper/SS body inner shell suitable for water storage heater (geyser) of 25 ltr capacity as per sample including taking down old unsv steel/copper tank complete all as specified and as directed |
| 71 | S&F outer body ofwater storage heater (geyser)of 25 ltr capacity as per sample including taking down old unsv outer body complete all as specified and as directed |
| 72 | M&L for glass wool packing required for cover the 25ltrs copper inner shell to avoid the heat conduction including taking out old packing all as specified & directed. |
| 73 | S&F heating coil 2000/1500 Watt (Round/Trinangle type) in existing storage water heater(Geyser) suitable for 25 Ltrs capacity all as specified & directed. |
| 74 | S&F thermostat range of 30-80 degree, as per site requirement, size as per sample all as specified & directed. |
| 75 | S&F non return valve brass suitable of 15 mm dia including taking down all as specified & directed. |
| 76 | S&F steel pipe connection 60 cm long both end brass suitable for hot water supply and screw down 15 mm GI pipe completeall as specified & directed. |
| 77 | M&L for replacement of 12 x 100 MM bolts grouting in bricks masonary wall with 1:4 CM for mounting geyser all as specified & directed. |
| 78 | M&L base plate suitable for hanging of Geyser of capacity 25 ltr |
| 79 | Taking down of defective exhaust fan any capacity/make/model/size from its original locations for repair includingsealing of cable end , dismantling blades, clamps with bush, louvers & motors, refixing the same after repair & assembling complete set in same location etc including testing complete all as specified & directed |
| 80 | M&L for rewinding of exhaust fan motor 150/225/230/250 mm sweep 240 volt AC after dismantling complete motor assay, bearning, bushings, removal of burnt copper wire, cleaning of core inserting proper insulating paper in slots winding with copper wire as per existing gauge and assemble complete set complete all as specified and directed |
| 81 | M&L for rewinding of exhaust fan motor 300/450 mm sweep 240 volt AC after dismantling complete motor assay, bearning, bushings, removal of burnt copper wire, cleaning of core inserting proper insulating paper in slots winding with copper wire as per existing gauge and assemble complete set complete all as specified and directed |
| 82 | S&F in repair/replacementfan blade suitable for exhaust fan 150/225/230/250 mm sweep Metal/plastic body . |
| 83 | S&F in repair/replacementfan blade suitable for exhaust fan 300/450 mm sweep Metal body . |
| 84 | S&F in repair/replacementball bearing of exhaust fan of 150/225/230/250 mm sweep as per existing type complete all as specified and directed |
| 85 | S&F in repair/replacementball bearing of exhaust fan of 300/450 mm sweep as per existing type complete all as specified and directed |
| 86 | S&F in repair/replacement capacitor of cap 1/1.5/3.15 MFD sutitable forexhaust fan of 150/225/230/250/300/450 mm sweep as per existing type complete all as specified and directed |
| 87 | S&F in repair/replacement of exhaust fan motor suitable for exhaust fans 150/225/230/250 mm sweep plastic/Metal body. |
| 88 | S&F in repair/replacement of exhaust fan motor suitable for exhaust fans 300/450 mm sweep Metal body. |
| 89 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 90 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 4 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipealong with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 4 sqmm earth wire and 2 Run of 4 sqmm cable shall be measured as one run.) |
| 91 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipealong with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 6 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.) |