|
| 1 | Material & Labour for in replacement of light/fan Point wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly upto Ceiling rose/light point complete all as specified and directed. |
| 2 | All as per item No. 1 here in before One bell/buzzer point controlled by one bell push complete all as specified and as directed . |
| 3 | All as per item No. 1 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size complete all as specified and directed. |
| 4 | All as per item No. 1 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 5 | All as per item No. 1 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire withPVC boxes complete all as specified. |
| 6 | M&L for Point wiring for one socket outlet 16 Amp on independentboard with 4 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 4 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 7 | S&FSocket outlet 2 in 1, 5 pin, 5amp flush type |
| 8 | S&FSocket outlet 2 in 1, 5 pin, 5 and 15 amp flush type |
| 9 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed. |
| 10 | Supply and fixing in replacement of ceiling rose, surface bakelite, 65mm x 50mm ,two to three terminals complete all as specified & directed. |
| 11 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. |
| 12 | S&F bell/buzzer push 5/6 Amp,flush type complete all as specified & as directed. |
| 13 | S&F call bell ding dong electric AC, 240 volt, 50 HZ, surface type complete all as specified & as directed. |
| 14 | Supply and fixing lamp holder, insulated body with pack plate suitable batten fitting on wall duly grouted/fixed in solid block wall or on wooden boardcompleteall as specified and directed. |
| 15 | Supply & fixing Modular switch 1 way 6A,1 module, 240 Volts complete all as specified & directed. |
| 16 | Supply & fixing Modular switch 1 way 16A,1 module, 240 Volts complete all as specified & directed. |
| 17 | Supply & fixing Modular Socket, 6A - 5 pin combined 2 module, 240 Volts complete all as specified & directed. |
| 18 | Supply & fixing Modular Socket 6A/16A - 5 pin combined 2 module, 240 Volts complete all as specified & directed. |
| 19 | S&F modular White cover plate with frame 03 module |
| 20 | S&F modular White cover plate with frame 04 module |
| 21 | S&F modular White cover plate with frame 06 module |
| 22 | S&F modular White cover plate with frame 08 module |
| 23 | S&F modular Surface mounted plastic flush box 3 module |
| 24 | S&F modular Surface mounted plastic flush box 4 module |
| 25 | S&F modular Surface mounted plastic flush box 6 module |
| 26 | S&F modular Surface mounted plastic flush box 8 module |
| 27 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 28 | Supply and fixing LED light fitting with high out put diffuser 4 feet, 20 watt 220 V AC decorative type with driver holder including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 29 | S&F in replacement LED tube rod with high out put diffuser 4 feet,20 watt 220 V AC decorative one side connection type with driver holder complete all asspecified & directed. |
| 30 | Supply and fixing LED batten, 220V, AC decorative box type with holder suitable for fixing LED tube light 20/22 Watt connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 31 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, (Warm White) 220 V AC with high efficiency PMMA diffuser soft glare free light of colour white/warm white as per requirement at sitecomplete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 32 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, (Cool Day Light) 220 V AC with high efficiency PMMA diffuser soft glare free light of colour white/warm white as per requirement at sitecomplete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 33 | S&F in replacement Downlighter round 18 W (White/Warm White)type & Driver incl integrated electronic driver including taking down old unsv one complete all as specified and directed |
| 34 | S&F in replacement Downlighter surface mounted square 1x1 type 18 W (White/Warm White)type & Driver incl integrated electronic driver including taking down old unsv one complete all as specified and directed |
| 35 | S&F in replacement of new generation energy saving and environmental friendly long life LED building securitylight made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 25 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed. |
| 36 | S&F in replacement LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. |
| 37 | S&F in Decorative Post top for indirect light with IP65protection. Resistant to impact and corrosion. Glare-free and better uniformity of capacity 35 watt with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. |
| 38 | S&F in Decorative Garden Light Pressure die cast powder coated housing with PCdiffuser, Efficient high output LED with IP65 protection of capacity 10 watt (CDL/WW) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. |
| 39 | S&F LED rechargeable lamp 12 Watt, CDL, B-22 cap, (Pin type), 230W, PF not less tha0.85 (min). |
| 40 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 4 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipealong with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 4 sqmm earth wire and 2 Run of 4 sqmm cable shall be measured as one run.) |
| 41 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipealong with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 6 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.) |
| 42 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 43 | Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 8 way 200 Amp rated busbarsingle pole and neutral fixed to wall on PVC board. |
| 44 | Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 4 way 200 Amp rated busbarsingle pole and neutral fixed to wall on PVC board. |
| 45 | Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 4 way 200 Amp rated busbartriple pole and neutral fixed to wall on PVC board. |
| 46 | S&F MCB TPN having braking capacity 10KA, 63 Amps, 240 Vcomplete all as specified and directed. |
| 47 | S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 Vcomplete all as specified and directed. |
| 48 | S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 Vcomplete all as specified and directed. |
| 49 | S & F in replacement of MCCB,04 Pole, capacity 63/100 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 50 | S & F in replacement of MCCB,04 Pole, capacity 125 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 51 | S&F in replacement of distribution board vertical type TPN 415 Volt for fixing 4 pole MCCB, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed. |
| 52 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20A complete all as specified and directed |
| 53 | Taking down of defective geyser of any capacity from different locations for repair including removing of electric connection, pipe fitting without any damage and refixing the same after repair in same/desired location complete all as specified & directed. Note :- The parts required for repair shall be measured separately under relevent item |
| 54 | S&F copper/SS body inner shell suitable for water storage heater (geyser) of 50 ltr capacity as per sample including taking down old unsv steel/copper tank complete all as specified and as directed |
| 55 | S&F outer body ofwater storage heater (geyser)of 50 ltr capacity as per sample including taking down old unsv outer body complete all as specified and as directed |
| 56 | S&F copper/SS body inner shell suitable for water storage heater (geyser) of 25 ltr capacity as per sample including taking down old unsv steel/copper tank complete all as specified and as directed |
| 57 | S&F outer body ofwater storage heater (geyser)of 25 ltr capacity as per sample including taking down old unsv outer body complete all as specified and as directed |
| 58 | M&L for glass wool packing required for cover the 25/50 ltrs copper inner shell to avoid the heat conduction including taking out old packing all as specified & directed. |
| 59 | S&F heating coil 1500 Watt in existing storage water heater(Geyser) suitable for 25 Ltrs capacity all as specified & directed. |
| 60 | S&F heating coil 2000 Watt in existing storage water heater(Geyser) suitable for 25/50 Ltrs capacity all as specified & directed. |
| 61 | S&F thermostat range of 30-80 degree, as per site requirement, size as per sample all as specified & directed. |
| 62 | S&F non return valve brass suitable of 15 mm dia including taking down all as specified & directed. |
| 63 | S&F indicator lamp red/green colour suitable for storage water heater any capacityall as specified & directed. |
| 64 | S&F steel pipe connection 45 cm long both end brass suitable for hot water supply and screw down 15 mm GI pipe completeall as specified & directed. |
| 65 | S&F steel pipe connection 60 cm long both end brass suitable for hot water supply and screw down 15 mm GI pipe completeall as specified & directed. |
| 66 | M&L for replacement of 12 x 100 MM bolts grouting in bricks masonary wall with 1:4 CM for mounting geyser all as specified & directed. |
| 67 | S&F geyser base plate front & rear suitable for existing geyser of capacity 25/50 ltrs complete all as specified & directed. |
| 68 | S & Fincl leakage testing galvanised steel water tubing medium grade 15 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. |
| 69 | S&F Bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge. |
| 70 | Taking down of defective exhaust fan any capacity/make/model/size from its original locations for repair includingsealing of cable end , dismantling blades, clamps with bush, louvers & motors, refixing the same after repair & assembling complete set in same location etc including testing complete all as specified & directed |
| 71 | S&F in repair/replacement of exhaust fan motor suitable for exhaust fan 200 mm sweepplastic body. |
| 72 | S&F in repair/replacement of fan blade suitable for exhaust fan 200 mm sweepplastic body. |
| 73 | S&F in repair/ replacement of old unservisableof frame made with engineering plastic complete suitable for 200 mm exhaust fan plastic body white colour all as directed |
| 74 | Supply only louvers suitable for exhaust fans 225/230 mm sweep. |
| 75 | Supply only louvers suitable for exhaust fans 300mm sweep. |
| 76 | Supply only louvers suitable for exhaust fans 450mm sweep. |
| 77 | S&F in repair/replacement of exhaust fan motor metal body suitable for exhaust fans 300 mm sweep. |
| 78 | S&F in replacement of old unservisableof frame with three/four legs suitable for 300 mm exhaust fan metal body of smoke grey colour all as directed |
| 79 | S&F in replacement of old unservisableof fan blade with split pin suitable for 300 mm exhaust fan of smoke grey colour all as directed |
| 80 | S&F in repair/replacement of exhaust fan motor metal body suitable for exhaust fans 450 mm sweep. |
| 81 | S&F in replacement of old unservisableof frame with three/four legs suitable for 450 mm exhaust fan metal body of smoke grey colour all as directed |
| 82 | S&F in replacement of old unservisableof fan blade with split pin suitable for 450 mm exhaust fan of smoke grey colour all as directed |
| 83 | S&Fin repair/replacement of exhaust fan motor metal body suitable for exhaust fans 225/230 mm sweep |
| 84 | S&F in replacement of old unservisableof frame with three legs suitable for 225/230 mm exhaust fan metal body of smoke grey colour all as directed |
| 85 | S&F in replacement of old unservisableof fan blade with split pin suitable for 225/230 mm exhaust fan metal bodyof smoke grey colour all as directed |
| 86 | Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade,of size 25 sqmm 4 core as per IS 7098 Pt-IIlaid in trenches / ducts / encased in GI pipe / fixed to polecomplete all as directed andspecified. |
| 87 | Description all as per item no 86 above but of size 16 sqmm 2 core |
| 88 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 89 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. |
| 90 | Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out any type of soil complete all as specified and as directed. |
| 91 | Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 92 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 93 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning. |
| 94 | Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm,local made super quality complete all as specified and directed. |
| 95 | Supply and laying galvanised tube light gradeISI marked of size 40 mm dia incl all fittingsin trenches/fixed on pole/wall/floor or laid in positionincluding repairing of demolished cemented portion complete all as specified and directed. |
| 96 | S&F LED Driver suitable for 18W Led light complete all as specified and directed. |
| 97 | S&F LED Driver suitable for 36W Led light complete all as specified and directed. |