| 1 | Excavation in trenches not exc 1.5m in wide and not exc 1.5 m in depth and getting out in hard/dense soil for laying of cables all as specified and directed. |
| 2 | Returning, filling in, including spreading , levelling, watering and well ramming in layers not exc 25cm in soft / disintegrated rock complete all as directed. |
| 3 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as directed. |
| 4 | Materials and Labour Cutting /boreing of existing road / path , hardstanding etc forlayingout cable with suitable GIpipe medium grade to proteat cableand making good the disturbed road top surfaces withcement concrete any type, suitable depth and finishedcomplete all as directed by Engineer-in-Charge. |
| 5 | M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of pole etc including form work complete all as specified and directed. |
| 6 | M&L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all as specified and directed. |
| 7 | S&F energy efficient warm white LEDbollard outdoor garden light 10 watt height 800mmIP-65rated inverted pyramid Tripod type fitting with soft 360 degree light distribution.All necessary wiring , clamps, nut and bolts mounting accessories etc all as specified and directedby Engineer-in-Charge.Make- Crompton/Philips/Luker or Equivalent. |
| 8 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 10 Sqmm4 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 9 | Supply & laying DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc.,with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed |
| 10 | S & F hot pressure moulded SMC Junction box ISI marked, with hinges suitable hosing for MCB SP including fixing mechanical nut bolts washer clamps etc complete to be fixed on the poles,PCC copping etc all as specifed and as directed at site.Make- Sintex/Hensel or equivalent. |
| 11 | M&L for submain wiring fortwo single core PVC insulated unsheathed , 1100 Volts grade, copper cable 1.5 Sqmm multistranded conductor and drawing through and including rigid PVCconduit of suitable sizebut not less than 20mm dia with conduit accessories etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade,cable 1.5 Sqmm copperconductor fixed to poles with saddles and screws and all as specified and as directed Note :- One run of PVC conduit, consist of two runs of cable1.5 Sqmm and one run of earth wire 1.5 Sqmm shall be measured and paid as one unit. |
| 12 | Material and labour for earthing complete with Glavnised iron plate 60x60 cm x 6 mm thick electrode buried directly in ground (earth pit no less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtrs below normal ground level connected to glavnasied earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers all as shown in electrical plate no. 5 connected to earth test point and provn of GI pipe 20 mm dia medium grade for watering, GI pipe 40 mm dia light grade for earth strip protectionall as specified and including excavation, earth workprovn ofearth pit, pit cover, CI funnel, wire mesh etccomplete and testing on completion. |
| 13 | S & F Street light timer switch panel box for security light,to be fixed on wall range 6W to 12W confirming to IS/IEC 60947-1 provided with protection degree IP 54, Extrended with brand coil, with FRLS internal wiring, inbuildshort circuitprotection,Class H insulation all as specified and as directed by the Engr-in-Charge.Make- Indo Asian/Havells/L&T or Equivalent. |