| 1 | S&F for 12mm thick sheet glass, to be fixed with UPVC frame alongwith all necessary fittings completeall as specified and directed. |
| 2 | S&F heavy duty double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel complete all as spd and directed. |
| 3 | S&F for stainless steel entrance main glass door pipe pull handle (length 18\", hole to hole size 14\" )with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, with suitable arrangement completeall as specified and directed |
| 4 | Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm(tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge |
| 5 | Material & Labour for complete removal of existing treatment,preparation ofsurfaces of plastered walls and applying Twocoats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. over and includinga coat ofprimer and 1.0 mm thick white wall care putty (premiumquality) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified . |
| 6 | Complete removal of existing treatment and applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over plastered surfaces of walls to prepare the surface even and smooth complete all as specified . . |
| 7 | M&L 4mm thickany colour ACP board (Aluminium composite panel), exterior grade, (approved colour) fixed with aluminium tapperd clip to aluminium frame work all as specified and as directed. |
| 8 | Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for and removal of rubbish off the site complete all as spd and directed. |
| 9 | Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), completeall as specified and directed. |
| 10 | Demolition of brick work built in lime mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr as specified, completeall as specified and directed.. |
| 11 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding, completeall as specified and directed. |
| 12 | M&L for moorum/red bajri filling in pavings, spread and levelling in layers n.exc 15 cm thick including well ramming and watering as required, completeall as specified and directed. |
| 13 | M & L for Cement concrete (1:4:8) Type D2 using 40 mm graded crushed stone aggregates as in foundations, filling and mass-concrete complete all asspecified and directed. |
| 14 | M & L for Cement concrete (1:3:6) Type C2 using 40 mm graded crushed stone aggregates as in foundations, filling and mass-concrete complete all asspecified and directed. |
| 15 | M&L for old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius build in CM 1:4 all as specified as directed. |
| 16 | All as per item No 15.00 mentioned here-in-before but except bricks complete all as specified and directed. |
| 17 | M&L for cement concrete type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) in surface channels and drains for benching complete all as specified and directed. |
| 18 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finish smooth & even with using extra cement complete all as specified and directed. |
| 19 | M&L forforming fair finish drain channelinner girth exc 30 cm but not exc 50 cm in girth in cement concrete using extra cement complete all as specified and directed. |
| 20 | M&L for Providing cement concrete type B-0, 1:2:4 (12.5mm grades aggregate) in window or door cills,lintels, bressumers,steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks,ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc including frames(of any section indicated), with plain fair faces, includingchamfers, weatherings, throat- ing etc. and setting in mortar 1:4 complete with joints to match complete all as spd and directed. |
| 21 | M&Lfor RCC precast cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in cover slab for drain and similar article with plain face set in cement mortar 1:6 complete all as spd and directed |
| 22 | M&L for Providing, cement concrete type B1 1:2:4 (Using 20mm garded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as spd and directed |
| 23 | M & L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all asspecified and directed. |
| 24 | S&F for 600mm bore reinforced concrete pipes, class NP2 , laid and jointed complete all as spd and directed. |
| 25 | Material and labour for cement concrete bed to drain pipe for 600mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 26 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all asspecified and directed. |
| 27 | Removing excavated material exc. 500 m or part thereof beyond 500 m and upto total distance of 1.5 km at a level not exc. 1.5 m above the starting point complete all as specified and as directed. |