|
| 1 | Material & Labour for light/fan Point wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly upto Ceiling rose/light point complete all as specified and directed. |
| 2 | All as per item No. 1 here in One bell/buzzer point controlled by one bell push complete all as specified and as directed . |
| 3 | All as per item No. 1 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size complete all as specified and directed. |
| 4 | All as per item No. 1 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specifieddirected. |
| 5 | All as per item No. 1 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed FRLSH cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire withPVC boxes complete all as specified. |
| 6 | M&L for Point wiring for one socket outlet 16 Amp on independentboard with 4 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 2.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 7 | S&FSocket outlet 2 in 1, 3 pin, 6 amp flush type |
| 8 | S&FSocket outlet 2 in 1, 3 pin, 6 and 16 amp flush type |
| 9 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 16 Amp, 240 Volts complete all as specified & directed. |
| 10 | Supply and fixing in replacement of ceiling rose, surface bakelite, 65mm x 50mm ,two to three terminals complete all as specified & directed. |
| 11 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified & directed. |
| 12 | S&F bell/buzzer push 5/6 Amp,flush type complete all as specified & as directed. |
| 13 | S&F call bell ding dong electric AC, 240 volt, 50 HZ, surface type complete all as specified & as directed. |
| 14 | Supply and fixing lamp holder, insulated body with back plate suitable batten fitting on wall duly grouted/fixed in solid block wall or on wooden boardcompleteall as specified and directed. |
| 15 | S&F LED lamp 5 Watt, CDL, B-22 cap, (Pin type), 230W, PF not less tha0.85 (min). |
| 16 | S&F LED lamp 9 Watt, Warm White, B-22 cap, (Pin type), 230W, PF not less tha0.85 (min). |
| 17 | S&Frechargeable LED lamp 12/13 Watt, B-22 cap, (Pin type), 230W, PF not less tha0.85 (min). |
| 18 | S&F LED lamp 15 Watt, CDL, B-22 cap, (Pin type T bulb), 230W, PF not less tha0.85 (min). |
| 19 | S&F in replacement LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with three core flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. |
| 20 | S&F in replacement LED tube mirror type with high out put diffuser 4 feet,20 watt 220 V AC decorative one side connection type with driver holder complete all asspecified & directed. |
| 21 | Supply and fixing LED light fitting mirror type 10W (White/warm white) with high out put diffuser 2 feet,220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. |
| 22 | Supply and fixing LED light fitting 1 x 20 Watt (White/warm white) 220 volt AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 23 | Supply and fixing in replacement of LED batten suitable for single or twin LED Retrofit T8 Tubes 20W with integral LED driver including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. |
| 24 | Supply and fixing downlighter round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 25 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 6500K, (White/ warm white)220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 26 | Supply and fixing in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 27 | Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 28 | S & F in replacement of GI brackets for fixing LED building security light fitting fabricated out of GI tubing 32 mm dia, light grade,0.9 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 30 x 4 mm -02 Nos complete for fixing on wallincluding all fixing arrangements such as fastners, bilts, nuts, bolts washers etcincluding making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge |
| 29 | Supply and fix sheet metal enclosures for DBs double door when MCBs to be used 230 volts 4 way 200 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 30 | Supply and fix sheet metal enclosures for DBs double door when MCBs to be used 230 volts 8 way 200 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 31 | Supply and fix sheet metal enclosures for DBs double door when MCBs to be used 230 volts 12 way 200 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 32 | S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 V\"C\" curve complete all as specified and directed. |
| 33 | S&F MCB SP having braking capacity 10KA, 10 Amps, 240 V \"C\" curve complete all as specified and directed. |
| 34 | S&F MCB SP having braking capacity 10KA, 16 Amps, 240 V \"C\" curve complete all as specified and directed. |
| 35 | S&F MCB SP having braking capacity 10KA, 32 Amps, 240 V \"C\" curve complete all as specified and directed. |
| 36 | S&F in replacement of distribution board vertical type TPN 415 Volt for fixing MCB/Isolator as incomer, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed. |
| 37 | S&F in replacement of distribution board vertical type TPN 415 Volt for fixing 4 pole MCCB, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed. |
| 38 | S & F in replacement of MCCB,04 Pole, capacity 63/100 Amps with ultimate breaking capacity 18 KA at 415 volts with Adjustable Thermal & Fixed Magnetic setting conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 39 | S & F in replacement of MCCB,04 Pole, capacity 125 Amps with ultimate breaking capacity 18 KA at 415 volts withAdjustable Thermal & Fixed Magnetic setting conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 40 | S&F metal plug and socket assembly, SPN sheet metal enclouser with a two pin and earth plug and socket complete with one SP, MCB 20Amp \"C\" curve fixed flush to wall/other surface complete all as specified and directed. |
| 41 | Taking down of defective geyser of any capacity from different locations for repair including removing of electric connection, pipe fitting without any damage and refixing the same after repair in same/desired location complete all as specified & directed. Note :- The parts required for repair shall be measured separately under relevent item of Sch \"A\" |
| 42 | S&F copper/SS body inner shell suitable for water storage heater (geyser) of 50 ltr capacity as per sample including taking down old unsv steel/copper tank complete all as specified and as directed |
| 43 | S&F copper/SS body inner shell suitable for water storage heater (geyser) of 25 ltr capacity as per sample including taking down old unsv steel/copper tank complete all as specified and as directed |
| 44 | S&F outer body ofwater storage heater (geyser)of 50/25 ltr capacity as per sample including taking down old unsv outer body complete all as specified and as directed |
| 45 | M&L for glass wool packing required for cover the 25/50 ltrs copper inner shell to avoid the heat conduction including taking out old packing all as specified & directed. |
| 46 | S&F heating coil 1500 Watt in existing storage water heater(Geyser) suitable for 25 Ltrs capacity as per sample all as specified & directed. |
| 47 | S&F heating coil 2000 Watt in existing storage water heater(Geyser) suitable for 25 Ltrs capacity as per sample all as specified & directed. |
| 48 | S&F thermostat range of 30-80 degree, as per site requirement, size as per sample all as specified & directed. |
| 49 | S&F non return valve brass suitable of 15 mm dia including taking down all as specified & directed. |
| 50 | S&F indicator lamp red/green colour suitable for storage water heater any capacityall as specified & directed. |
| 51 | S&F steel pipe connection 45 cm long both end brass suitable for hot water supply and screw down 15 mm GI pipe completeall as specified & directed. |
| 52 | M&L for replacement of 12 x 100 MM bolts grouting in bricks masonary wall with 1:4 CM for mounting geyser all as specified & directed. |
| 53 | S&F geyser base plate front & rear suitable for existing geyser of capacity 25/50 ltrs complete all as specified & directed. |
| 54 | Taking down of defective exhaust fan any capacity/make/model/size from its original locations for repair includingsealing of cable end , dismantling blades, clamps with bush, louvers & motors, refixing the same after repair & assembling complete set in same location etc including testing complete all as specified & directed |
| 55 | M&L for rewinding of exhaust fan 250/300 mm sweep 240 volt AC after dismantling complete motor assay, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/ turn of super enamelled copper wire, heating, varnishing, replacement of unsv bearings/ bushings,and testing complete all as specified and directed. |
| 56 | M&L for rewinding of exhaust fan 450 mm sweep 240 volt AC after dismantling complete motor assay, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/ turn of super enamelled copper wire, heating, varnishing, replacement of unsv bearings/ bushings,and testing complete all as specified and directed. |
| 57 | Supply only ball bearing ofexhaust fan 250/300/4500 mm sweep as per manufacture instruction complete all as specified and directed. |
| 58 | Supply only fan condensor cap 1/1.8/3.15 MFD suitable for exhaust fans 250/300/450 mm sweep. |
| 59 | Supply only louvers suitable for exhaust fans 250/300mm sweep. |
| 60 | Supply only louvers suitable for exhaust fans 450 mm sweep. |
| 61 | S&F exhaust fan motor suitable for exhaust fans 250/300 mm sweep. |
| 62 | S&F exhaust fan motor suitable for exhaust fans 450 mm sweep |
| 63 | S&F in replacement of old unservisableof frame with four legs suitable for 450 mm exhaust fan of smoke grey colour all as directed |
| 64 | S&F in replacement of old unservisableof frame with four legs suitable for 300 mm exhaust fan of smoke grey colour all as directed |
| 65 | S&F in replacement of old unservisableof frame with four legs suitable for 225/230 mm exhaust fan of smoke grey colour all as directed |
| 66 | S&F in replacement of old unservisablebody of with complete cover suitable for 225/230 mm exhaust fan matching with existing colourall as directed |
| 67 | S&F in replacement of old unservisableof fan blade with split pin suitable for 225/230 mm exhaust fanall as directed |
| 68 | S&F in replacement of old unservisableof fan blade with split pin suitable for 300 mm exhaust fan of smoke grey colour all as directed |
| 69 | S&F in replacement of old unservisableof fan blade with split pin suitable for 450 mm exhaust fan of smoke grey colour all as directed |
| 70 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 71 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed FRLSH cable with multistranded copper conductor 4 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipealong with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 4 sqmm earth wire and 2 Run of 4 sqmm cable shall be measured as one run.) |
| 72 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed FRLSH cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipealong with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 6 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.) |
| 73 | Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade,of size 16 sqmm 4 core as per IS 7098 Pt-IIlaid in trenches / ducts / encased in GI pipe / fixed to polecomplete all as directed andspecified. |
| 74 | Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade,of size 16 sqmm 2 core as per IS 7098 Pt-IIlaid in trenches / ducts / encased in GI pipe / fixed to polecomplete all as directed andspecified. |
| 75 | Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade,of size 25 sqmm 4 core as per IS 7098 Pt-IIlaid in trenches / ducts / encased in GI pipe / fixed to polecomplete all as directed andspecified. |
| 76 | Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out in any type of soil complete all as specified and as directed. |
| 77 | Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 78 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 79 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning. |
| 80 | Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm,factory madeof specified make , complete all as specified and directed. |
| 81 | Supply and laying galvanised tube light gradeISI marked of size 40 mm dia incl all fittingsin trenches/fixed on pole/wall/floor or laid in positioncomplete all as specified and directed. |
| 82 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 83 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. |
| 84 | Taking downsub main wiring/ Building service /cable connection of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC. |
| 85 | Supply and fix LED driver 36 W suitable for LED pane 600mmx 600mm, 240 V, 50 Hz, PF>0.9 complete all as specified and directed. |
| 86 | Supply and fix LED driver 18 W suitable for LED pane 600mmx 600mm, 240 V, 50 Hz, PF>0.9 complete all as specified and directed. |
| 87 | Supply and fix capacitor of 2.5/3.15 MFD for all type of fan,cylindrical plastic housing with wire lead mounting,230V, 50 Hz complete all as specified and directed. |
| 88 | Supply and fix fan regulator dimmer type,button control, rotary switch, 240V, 50Hz , 1 Module, 5 step complete all as specified and directed. |