Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking downfor servicingof split type AC 1.5TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if requiredand keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 2 | Repairs/Servicing Air Conditioner 2.0 Ton Capacity, Window type at Site of any Make and any type by replacing unserviceable Parts (like Compressor and other Minor Parts viz Capilary Tube, Machine Screws, Washer, Rubber Bush, etc) from the Machine including Charging of Refrigerant Gas after vacuuming and leak testing, brazing the suction/discharge tubes where required and cleaning of Condensing Unit to achieve proper Cooling effect, checking of Electrical Circuit of machine and repair where necessary by replacing proper size PVC insulated Wires and cleaning of AC using air blower as directed, commissioning & Testing, complete all as specified and directed.NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 3 | Taking downfor servicingofWindow type AC 1.5TRCapacityincluding cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 4 | Taking downfor servicingofWindow type AC 2.0 TR Capacity including cleaning of cooling coil, air filters,condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 5 | S&F in repair, starting relay for 1.5 TR compressor all as specified and directed. |
| 6 | S&F in repair, starting relay for 2 TR compressor all as specified and directed. |
| 7 | S&F in repair, over load protector for 1.5 TR compressor all as specified and directed. |
| 8 | S&F in repair, over load protector for 2TR compressor all as specified and directed. |
| 9 | S&F in repair, Thermostate switch for 1.5 TRsplit/window type AC all as specified and directed. |
| 10 | S&F in repair, Thermostate switch for2 TR split/Window type AC all as specified and directed. |
| 11 | S&F in repair, of Starting capacitor 80-100 Mfd capacity in metal containerall as specified and directed. |
| 12 | S&F in repair, of Starting capacitor 120-150 Mfd capacity in metal containerall as specified and directed. |
| 13 | S&F in repair, of running capacitor 36 Mfd capacity in metal container pin type all as specified and directed. |
| 14 | S&F in repair, of running capacitor 50±4 Mfd capacity in metal container pin type all as specified and directed. |
| 15 | S&F in repair, of running capacitor 50±6 Mfd capacity in metal container pin type all as specified and directed. |
| 16 | S&F in repair, Running capacitor 10 mfd metal body pin type complete all as specified and directed |
| 17 | S&F in repair, Running capacitor 6 mfd metal body pin type complete all as specified and directed |
| 18 | S&F in repair, Running capacitor 4 mfd metal body pin type complete all as specified and directed |
| 19 | S&F in repair, Running capacitor 2.5 mfd metal body pin type complete all as specified and directed |
| 20 | S&F in repair, suction copper pipe line heavy duty 1/2\"\" diaand flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed. |
| 21 | S&F in repair, discharge copper pipe line heavy duty 1/4\" diaand flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed. |
| 22 | S&F in repair, discharge copper pipe line heavy duty 5/8\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed. |
| 23 | S&F in repair, discharge copper pipe line heavy duty 3/8\" diaand flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed. |
| 24 | S&F in repair, discharge copper pipe line heavy duty 3/4\" diaand flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed. |
| 25 | S&F in repair, PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed. |
| 26 | S&F Foam insulation for copper tubing of size 1/2\"\" dia complete all as specifed and directed. |
| 27 | S&F Foam insulation for copper tubing of size 5/8\"\" dia complete all as specifed and directed. |
| 28 | S&F Foam insulation for copper tubing of size 1/4\"\" dia complete all as specifed and directed. |
| 29 | S&F Foam insulation for copper tubing of size 3/8\"\" dia complete all as specifed and directed. |
| 30 | S&F Foam insulation for copper tubing of size 3/4\"\" dia complete all as specifed and directed. |
| 31 | S&F in repair, condensing copper coil unit of split type AC of 1.5 TR capacity complete all as specified and directed. |
| 32 | S&F in repair, condensing coppercoil unit of split type AC of 2 TR capacity complete all as specified and directed. |
| 33 | S&F in repair, blower motor of 1.5 TR split AC (indoor unit) of existing manufacturer of AC. Make of AC Carrier/Voltas /Blue star complete all as specified and directed. |
| 34 | S&F in repair, blower motor of 2 TR split AC (indoor unit) of existing manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung complete all as specified and directed. |
| 35 | Dismantling of burnt condensor motor of 1.5 TR split AC (Outdoor unit) and rewinding & refixingcondensormotor at same position including replacement of bearing bushing complete. Make of AC Carrier/Voltas /Blue star complete all as specified and directed. |
| 36 | Dismantling of burnt condensor motor of 2 TR split AC (Outdoor unit) and rewinding & refixing condensor motor at same position including replacement of bearing bushing complete. Make of AC Carrier/Voltas /Blue star/LG/Samsungas per sample complete all as specified and directed. |
| 37 | Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and supply & fixing swing motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung complete all as specified and directed. |
| 38 | Dismantling of burnt swing motor of2 TR split AC (indoor unit) and supply & fixing swing motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung complete all as specified and directed. |
| 39 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 typein required quatity complete all as specified and directed. |
| 40 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-134 typein required quatity complete all as specified and directed. |
| 41 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-410 typein required quatity complete all as specified and directed. |
| 42 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 typein required quatity complete all as specified and directed. |
| 43 | Supply and chargingthe ACunit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quatity complete all as specified and directed. |
| 44 | Supply and fixed in repairs ofsuction valve size 1/2\" complete all as specified and directed . |
| 45 | Supply and fixed in repairs of discharge valve size 1/4\" complete all as specified and directed. |
| 46 | Supply and fixed in repairs ofsuction valve size 5/8\" complete all as specified and directed . |
| 47 | Supply and fixed in repairs of discharge valve size 3/8\" complete all as specified and directed. |
| 48 | Dismantling of un-serviceable cooling coil unitany type any size of indoor unit of split type Air Conditioner of capacity 1.5 TRby cutting the suction line and discharge line, and providing new cooling copper coil unit of indoor unit (of same capacity), including testing on completion complete all as directed |
| 49 | Dismantling of un-serviceable cooling coil any type any size of indoor unit of split type Air Conditioner of capacity 2.0 TRby cutting the suction line and discharge line, and providing new cooling copper coil of indoor unit (of same capacity),including testing on completion complete all as directed |
| 50 | M&L for carrying out pressure leak test of split ACs 1.5 / 2.0 TRcapacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at sitecomplete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule |
| 51 | M&L for carrying out pressure leak test of split ACs 2.0 TRcapacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at sitecomplete all as specified and directed.Note : Cost of Nitrogen gas will be paid under respective schedule |
| 52 | M&L carrying out pressure leak test of 1.5 TR windowAC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule |
| 53 | M&L carrying out pressure leak test of 2.0 TR windowAC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule |
| 54 | Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 55 | Dismantling of defective worn out wiring of indoor unit of split AC of capacity 2 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 56 | Supply and fixing in repairs front grillfor window AC of 1.5 TR /2TR of existing make complete all as specified and directed. |
| 57 | S&FPVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all as specified and as directed. |
| 58 | S&F Bottom tray of 1.5 ton /2 ton capacity window type AC made out of 14 SWG mild steel sheet Including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 59 | Taking out existing out door unit of split type Air Conditioner including refrigerant lines and electrical connections (of capacity 1.5 TR / 2.0 TR) and re-fixing atnew location as directedalongwith fixing arrangement with nuts and bolts complete all as directed (Note :- Excess requirement of refrigerant pipe line, AC outdoor metalic stand ,electric connection cable , drain pipe topping up of refrigerant gas shall be measured and paid separately under relevant item of this schedule) |
| 60 | Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing atnew location alongwith fixing arrangement with screwed on wooden gutkaon wall surface and making good the disturbed surfaces complete all as directed (Note :- Excess requirement of refrigerant pipe line, electric connection cable ,drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule) |
| 61 | S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 tonreciprocating compressor by removing of old burnt compressor andfixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitorsetc. complete all as specified and as directed.Note :- Charging of gas refrigerant will be paid and measured separately |
| 62 | All as per item No 61 here in before but 2 TR capacity reciprocating compressor |
| 63 | All as per item No 61 here in before but 1.5 TR capacity rotary type compressor |
| 64 | All as per item No 61 here in before but 2 TR capacity rotary compressor |
| 65 | S&F Condenser fan blade suitable for 1.5 TR capacity Split type Air Conditionerincluding taking out old one complete all as specified and as directed. |
| 66 | S&F Condenser fan blade suitable for 2.0 TR capacity Split type Air Conditionerincluding taking out old one complete all as specified and as directed. |
| 67 | S&F Roller runner, suitable for 1.5 TRcapacity Split type Air Conditionerincluding taking out old one complete all as specified and as directed. |
| 68 | S&F Roller runner, suitable for2.0 TRcapacity Split type Air Conditionerincluding taking out old one complete all as specified and as directed. |
| 69 | Taking down indoor unit of 1.5 TRcapacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed (Note:-The repair of indoor motor, filters and roller runnerto be measured and paid separately under relevant item ) |
| 70 | Taking down indoor unit of 2.0 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed (Note:-The repair of indoor motor, filters and roller runnerto be measured and paid separately under relevant item ) |
| 71 | S&F in replacement of AC Outdoor metallic stand for fixing out door unit complete all as specified and as directed. |
| 72 | Taking down unserviceable blower motor base (2mm thick Mild Steel Sheet) of 1.5 TR/2TR capacity split AC and supply and fixing new blower motor base by welding / fixing by nut and boltrefixing the blower motor after completing the base and aligning the motorcomplete as directed |
| 73 | S&F Compressor sealed unit ofWindow type Air Conditioner of capacity 1.5 TR reciprocating typeby removing of old burnt compressor andfixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes complete all as directed |
| 74 | All as per item No 73 here in before but 2.0 TR capacity reciprocating compressor. |
| 75 | All as per item No 73 here in before but 1.5 TR capacity rotary type . |
| 76 | All as per item No 73 here in before but 2.0 TR capacity rotary compressor. |
| 77 | S&FCooling coil condenser unit of Window type Air Conditioner of capacity 1.5/2.0 TR including providing connections and fixing in proper position including taking down old unserviceable one complete all as directed |
| 78 | Taking downunserviceable blower motor of existing make/model ofwindow type Air Conditioner 1.5 TRand refixing in proper position after rewinding and repair including providing all connections, complete all as directed |
| 79 | Taking downunserviceable blower motor of existing make/model ofwindow type Air Conditioner2.0 TR and refixing in proper position after rewinding and repair including providing all connections, complete all as directed |
| 80 | S&F in repair, Blower motor fan blade of existing make/model ofwindow type Air Conditioner1.5 TRincluding providing all connections, in proper position complete all as directed |
| 81 | S&F in repair, Blower motor fan blade of existing make/model ofwindow type Air Conditioner2 TRincluding providing all connections, in proper position complete all as directed |
| 82 | S&F in repair,Runner of existing make/model ofWindow type Air Conditioner1.5 TR including providing all connections, in proper position complete all as directed |
| 83 | S&F in repairRunner of existing make/model ofWindow type Air Conditioner2 TR including providing all connections, in proper position complete all as directed |
| 84 | Taking down window type Air Conditioner, shifting and installation of same at other location within two Km radius including cutting and opening of existingbrick work and making good dismantled portion in cement mortar 1:3 as required ( exc. Half Brick but not exc. one brick thick Walls) and finishing the surfaces as per existing finishes, removing debries from the site complete all as specified and as directed. |
| 85 | M&L Cutting openings, through brick wall (one brick thick) for fixing of window type Air Conditioner, providing second class hard wood frame (sectional size not less than 50mmx50mm),providing 2 coats of syntheic enamel paint over a coat of primer, on wooden frame, size as per AC modelincluding fair finish of side walls in cement mortar (1:6) and finishing the surfaces as per existing finishes, removing debries from the site complete all as specified and as directed. |
| 86 | S&F Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed. |
| 87 | Supply and fix power contactor 2 pole, coil voltage 230Volts of capacity 25 Amps Complete all as specified and directed:- |
| 88 | Supply and fix power contactor 3 pole, coil voltage 415 Volts of capacity32 Amps Complete all as specified and as directed:- |
| 89 | Supply and Fix Timer single phase analogue type 230 volts complete all as specified and directed. |
| 90 | Supply and fix remote control hand setfor 2.0TR capacity split AC complete all as specified and as directed. |
| 91 | Supply and fix remote control hand setfor 1.5TR capacity split AC complete all as specified and as directed. |
| 92 | Supply and fix remote control hand setmake suitable for 2.0TR capacity window type AC complete all as specified and as directed. |
| 93 | Supply and fix remote control hand set suitable for 1.5 TR capacity window type AC complete all as specified and as directed. |
| 94 | M&L for servicing including cleaning of condenser coil fins with mild detergent, cleaning of indoor unitand descaling of condensor coil forVertical type3 phase Air Conditioner, of any make/capacity after taking down the outdoor unit and refixing in the existing location or any where and replacement of insulation of suction & discharge line complete all as specified and as directed. |
| 95 | S&F PCB kit complete for Verticaltype Air Conditionerof any make and capacity complete all as specified and as directed. |
| 96 | Taking downunserviceable Condensor motor of existing make/model of Vertical type Air Conditioner 2.5/3.5/4.5TR (Outdoor) and refixing in proper position after rewinding and repair including providing all connections, complete all as directed |
| 97 | Taking downunserviceable blower motor of existing make/model ofVertical type Air Conditioner 2.5/3.5/4.5 TR (Indoor) and supply and fixing in proper position including providing all connections, complete all as directed |
| 98 | Dismantling of defective condensing unit of Vertical type AC of 2.5 TR capacity and supply & fixing new condensing unit complete with condensing copper coil, complete all as specified and directed. |
| 99 | Dismantling of defective refrigerator of any make and capacityincluding transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/replacement of defective accessories/components and testing complete all as directed |
| 100 | Supply & Fix Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 165/180 ltrs complete all as specified and directed |
| 101 | Supply & Fix Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 280/310 ltrs complete all as specified and directed |
| 102 | Supply & Fix Thermostat defrost type switch suitable for refrigerator of capacity 165/220/310 ltrs complete all as specified and directed |
| 103 | Supply & Fix PTC Relay with overload suitable for refrigerator of capacity 165/190/200 ltrscomplete all as specified and directed |
| 104 | Supply & Fix PTC relay with overload suitable for refrigerator of capacity 250/286/310 Ltr complete all as specified and directed |
| 105 | Supply & Fix Capillary tube of size 0.36mm dia for any type/size refrigerator complete all as specified and directed |
| 106 | Supply & Fix Copper pencil strainers of size 4\" long double mouth complete all as specified and directed |
| 107 | Supply & Fix PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types complete all as specified and directed |
| 108 | Supply & FixBimetal2 wire/3wire /4 wire complete all as specified and directed |
| 109 | Supply & Fix Forst free fan motor SP 230 volts complete all as specified and directed |
| 110 | Supply & Fix Sensor for cooling coil complete all as specified and directed |
| 111 | Supply & FixPCBtimer of refrigerator 180-310ltrsrequired as per site complete all as specified and directed |
| 112 | Supply & Fix Condenser coil for 165 to 200 Ltrs complete all as specified and directed |
| 113 | Supply & Fix Condenser coil for 250 to 310 Ltrs complete all as specified and directed |
| 114 | S&F ofheating coil including fixing accessories suitable for 250/286/310 ltrscomplete all as specified and directed |
| 115 | Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directedfor Regrigerator of Capaicty 165/180 Ltrs complete all as specified and directed Note:-Re- Charging of gas will be measured and paid separetely |
| 116 | Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directedfor Refrigerator of Capaicty 285/310 Ltrs complete all as specified and directed Note:-Re- Charging of gas will be measured and paid separetely |
| 117 | Dismantling of defective water cooler storage type of 40/80/120/150 ltrs capacityincluding transportation to workshop and backfor thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed. |
| 118 | Supply & Fix Aluminium fan blade for blower motor for water cooler of capacity 40/80/120/150 ltrs complete all as specified and directed |
| 119 | Supply & Fix PCB and Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120/150 ltrs complete all as specified and directed |
| 120 | Supply & Fix Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120/150 ltrs complete all as specified and directed |
| 121 | Supply & Fix Relay for water cooler type suitable for water cooler storage cooling capacity 40/80 /120/150ltrs/hrs complete all as specified and directed |
| 122 | Supply & Fix Over load protector for compressor suitable for water cooler of capacity 40/80120/150 Ltrs complete all as specified and directed |
| 123 | Supply & Fix Self closing bib tap/push tap 15mm dia chromium plated steel suitable for water cooler 40/80/150/120 ltr/hrs capacity complete all as specified and directed |
| 124 | Supply & Fix PVC connection pipe high density 15mm dia 300mm long including jublee clamps for inner connection from tank outlet to tap. |
| 125 | Supply & Fix 15 mm dia PVC connection pipe 450 mm long complete with PVC union at both end complete all as specified and directed |
| 126 | Supply & Fix 15 mm dia Float valve PVC complete with all accessories complete all as specified and directed |
| 127 | Supply & Fix new compressor suitable for 40/40 ltr/hrs storage capacity including testing complete all as specified and directedNote:- (Recharging of gas will be measured and paid separately). |
| 128 | Supply & Fix new compressor suitable for 40/80 ltr/hrs storage capacity including testing complete all as specified and directed. Note:-(Recharging of gas will be measured and paid separately). |
| 129 | Supply & Fix new compressor suitable for 120 ltr/hrs storage capacity including testing complete all as specified and directed Note:-(Recharging of gas will be measured and paid separately). |
| 130 | Supply & Fix new compressor suitable for 150 ltr/hrs storage capacity including testing completeall as specified and directed.Note:-(Recharging of gas will be measured and paid separately). |
| 131 | Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testingsuitable for water cooler any make or type completeall as specified and directed. |
| 132 | Dismantling of defective deep freezer including transportation to workshop and back of any capacity, sizeand type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed |
| 133 | Supply & Fix new deep freedgecompressor for storage capacity of 400 ltrs deep freezer including testingall as specified and directed . Note:-(Recharging of gas will be measured and paid separately). |
| 134 | Supply & Fix new deep freedgecompressor for storage capacity of 500 ltrs deep freezer including testingall as specified and directed.Note:- (Recharging of gas will be measured and paid separately). |
| 135 | Supply & Fix Relay for deep freezer of any size/capacity complete all as specified and directed |
| 136 | Supply & Fix Overload for compressor of deep freezer of any size/capacity complete all as specified and directed |
| 137 | Supply & Fix Thermostate for deep freezer complete al as specified and directed |
| 138 | Supply & Fix 4\" condenser fan motor 240 volt complete all as specified and directed |
| 139 | Dismantling of defective worn out wiring of Outdoor unit of split AC of capacity 1.5 TR inverter typeincluding unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 140 | Dismantling of defective worn out wiring of Indoor unit of split AC of capacity 1.5 TR inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 141 | Dismantling of defective worn out wiring of Outdoor unit of split AC of capacity 2.0 TR inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 142 | Dismantling of defective worn out wiring of Indoor unit of split AC of capacity 2.0 TR inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 143 | Taking down unserviceable inverter Outdoor Condensor motor of 1.5 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed |
| 144 | Taking down unserviceable inverter indoor blower motor of 1.5 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed |
| 145 | Taking down unserviceable inverter Outdoor Condensor motor of 2.0 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed |
| 146 | Taking down unserviceable inverter indoor blower motor of 2.0 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed |
| 147 | Taking down unserviceable inverter compressor and S&F Compressor sealed unit for Inverter Split type Air Conditioner of capacity 1.5 ton inverter compressor by removing of old burnt compressor andfixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitorsetc. complete all as directed |
| 148 | Taking down unserviceable inverter compressor and S&F Compressor sealed unit for Inverter Split type Air Conditioner of capacity 2.0 ton inverter compressor by removing of old burnt compressor andfixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitorsetc. complete all as directed |
| 149 | Dismantling of defective worn out wiring ofRefrigerator of capacity 310 Ltr inverter typeincluding unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 150 | Dismantling of defective worn out wiring ofRefrigerator of capacity 180-250Ltr inverter typeincluding unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plateto suit /match the existing system complete all as specified and directed. |
| 151 | Dismantling and taking down carefully for Repair/ servicing of 3 phase, 415 V, 19 KW, 30 Kgs Capacity of Fully automatic Industrial Front loading WASHING MACHINE with Model No LME 30 of Make STEFAB INDIA LIMITED alongwith control panel duly disconnected the electrical and mechanical connections, for cleaning and servicing including necessary repair/maintenance by greasing welding works wherever required, cleaning of moving parts and inner perforated moving drun, tightening nuts and bolts and necessary electrical connections including testing complete for making it completely functional and replacement of damaged unserviceable spares as required and as directed.NOTE :(i) Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 152 | Supply only Reversing timer Complete all as directed |
| 153 | Supply onlySolenoid valve diaphram Complete all as directed |
| 154 | Supply onlyDrain valve solenoid Complete all as directed |
| 155 | Supply only Flange coupling with coupling tyre Complete all as directed |
| 156 | Supply only V Belt Complete all as directed |
| 157 | Supply only Temp controller cum indicator Complete all as directed |
| 158 | Supply only Selector switch Complete all as directed |
| 159 | Supply only Water valve Complete all as directed |
| 160 | Supply only Indicator lamp Complete all as directed |
| 161 | Supply only Contactor 16 Amps Complete all as directed |
| 162 | Supply only Citation Complete all as directed |
| 163 | Supply only Over load relay coil Complete all as directed |
| 164 | Supply only Over load protector 3.8 to 6.0 Amps Complete all as directed |
| 165 | Supply only MS Nut bolts big Complete all as directed |
| 166 | Supply only MS Nut bolts small Complete all as directed |
| 167 | Supply only Door Switch assembly Complete all as directed |
| 168 | Supply only PVC transparent water level pipe with check Nuts Complete all as directed |
| 169 | Dismantling and taking down carefully for Repair/ servicing of 3 phase, 415 V, 19 KW, 30 Kgs Capacity of industrial HYDRO EXTRACTORwith Model No HX 30of Make STEFAB INDIA LIMITED alongwith control panel duly disconnected the electrical and mechanical connections, for cleaning and servicing including necessary repair/maintenance by greasing welding works wherever required, cleaning of moving parts and inner perforated moving drun, tightening nuts and bolts and necessary electrical connections including testing complete for making it completely functional and replacement of damaged unserviceable spares as required and as directedNOTE :(i) Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 170 | Supply only\"V\" Belt, Complete all as directed |
| 171 | Supply only Clutch Spring Complete all as directed |
| 172 | Supply only Oil Seal Complete all as directed |
| 173 | Supply only Break Lining with rivets Complete all as directed |
| 174 | Supply only Suspension rod with Nut Complete all as directed |
| 175 | Supply only Spring of Suspension rod Complete all as directed |
| 176 | Dismantling and taking down carefully for Repair/ servicing of 3 phase, 415 V, 19 KW, 30 Kgs Capacity of industrial DRYING TUMBLER with Model No LME 30 of Make STEFAB INDIA LIMITED alongwith control panel duly disconnected the electrical and mechanical connections, for cleaning and servicing including necessary repair/maintenance by greasing welding works wherever required, cleaning of moving parts and inner perforated moving drun, tightening nuts and bolts and necessary electrical connections including testing complete for making it completely functional and replacement of damaged unserviceable spares as required and as directedNOTE :(i) Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 177 | Supply only Temp controller cum indicator for item No 176 here-in-above Complete all as directed |
| 178 | Supply only Reversing timer for item No 176 here-in-above Complete all as directed |
| 179 | Supply only Contactor 16 A Complete all as directed |
| 180 | Supply only Thermo couple Complete all as directed |
| 181 | Supply only Over load relay Complete all as directed |
| 182 | Supply only Inlet valve Complete all as directed |
| 183 | Supply only Outlet valve Complete all as directed |
| 184 | Supply only \"V\" Belts Complete all as directed |
| 185 | Supply only Steam trap Complete all as directed |
| 186 | Supply only Indicating lamp Complete all as directed |
| 187 | Opening carefully of Voltage stabiliser of capacity 5 KVA, removing the old U/S, rewinding of the current transformerwith stranded super enamelled copper winding wireas per existing size/gauge repairing the same with minor parts as required to make it functional complete all as specified and directed |
| 188 | All as per item No- 187 above but Voltage stabiliser of capacity 3KVA |
| 189 | All as per item No- 187 above but Voltage stabiliser of capacity 2.0 KVA |
| 190 | All as per item No- 187 above but Voltage stabiliser of capacity 1.0 KVA |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail