Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | (A) CIVIL WORKS, 1)-EARTHWORKS:- Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or softsoil |
| 3 | Excavation for foundation upto 1.5 m depthincludingsortingoutandstackingofuseful materials anddisposing off the excavated stuff upto 50 Meter lead. (B)Dense or Hard soil |
| 4 | Excavation for foundation fordepth from1.5 mto3.0 mincludingsortingoutand stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A)Looseorsoft soil |
| 5 | Excavation for foundation fordepth from1.5 mto3.0 mincludingsortingoutandstacking of useful materials anddisposing offtheexcavatedstuff upto50Meterlead. (B)Dense or Hard soil |
| 6 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each dispositedlayer by ramming and watering |
| 7 | Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete. |
| 8 | 2)- CONCRETE WORKS:- Providing and laying cementconcrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum- i)- All works upto plinth level |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cumii)-i All works above plinth levelupto floor V level |
| 11 | Providing Primary TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) Upto and above plinth level. |
| 12 | Providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes (A) 10mm to 16mm dia bar |
| 13 | 3)- FORMWORK:- Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. |
| 14 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceilingnotexceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth. |
| 15 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceilingnotexceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (I)Edgesofslabsand Breaks in floors and walls. (upto 10 ton) |
| 16 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceilingnotexceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns Pillars Posts and struts. (1) Square Rectangular Polygonal in plan. |
| 17 | 4)- MASONARY WORK:- Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B)Conventional.Extra for brick work in superstructure above plinth level upto floor two level (B)Conventional |
| 18 | Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional |
| 19 | FINISHING:-20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3(1-cement: 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement: 1-sand) etc. complete. |
| 20 | FINISHING:- 20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3(1-cement: 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement: 1-sand) etc. complete. (SINGLE FINAL COAT ONLY) |
| 21 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 22 | MISCELLANEOUS WORKS:- Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 23 | Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (A) In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like |
| 24 | TAXI WAY LINK 52M LENGTH GATE Providing and fixiProviding and laying taxiway linking works for motorized MS gate including foundation, civil and electrical components for a total length of 52 meters, comprising excavation in all types of soil, PCC/RCC foundation as per approved drawings, supply and installation of embedded MS gate base plates and anchor bolts, construction of plinth, cable trenching with RCC/HDPE ducts, backfilling and compaction, providing earthing, laying of power and control cables, termination, testing and commissioning of electrical connections for motorized MS gate, including all materials, labour, tools, testing, alignment, finishing and complete in all respects as per specifications, drawings and directions of Engineer-in-Charge. |
| 25 | 4)-WOOD WORK AND JOINERY:- Providingwoodworkin frames of Doors, windows cleare storywindowsand othersimilar works wrought,framede and fixed in position. (A) Indian Teak Wood (upto 10 ton) |
| 26 | Providing and fixing 35 mm thick shutters for Doors, windows and clearstory windows including blackenamelled M.S. butt hinges with necessary screws. (A) Indian teak wood. (i)Fully Panelled. (upto 10 ton) |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. For fixed portion |
| 28 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 30 | Providing and fiixng of Door Stopper of SS 304 Grade as directed by Engineer-in-charge. |
| 31 | Providing and fiixng of Door closer as directed by Engineer-in-charge. |
| 32 | Providing and fiixng of dead lock of SS 304 Grade as directed by Engineer-in-charge. |
| 33 | Providing and fiixng of Pull Handle of SS 304 Grade as directed by Engineer-in-charge. |
| 34 | Providing and fiixng of Mortise Lock of SS 304 Grade as directed by Engineer-in-charge. |
| 35 | 5)-FLOOR FINISHES:- Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab upto 0.50 sqm |
| 36 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. |
| 37 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 38 | P & L 24\" x 24\" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskid (upto 10 ton) |
| 39 | Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry |
| 40 | Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick |
| 41 | 6)- ROOFING AND CEILING WORKS:- Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation . The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size |
| 42 | Providing corrugated G.I. sheet of class-3 roofing fixed with glavanished iron J or L Hooks, Bolts and nuts 8mm diameter with bitumen and G.I. limpet washer or G.I. limpet washer. filled with white lead complete excluding the cost of purlins, Rafters and Trusses.(1) 0.80 mm thick sheet. |
| 43 | Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1- cement :4-sand) |
| 44 | 8)-PAINTING WORK:- Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 45 | Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. |
| 46 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 47 | 9)-MISCELLANEOUS WORKS:-Providing and fixing Toilet cubical made up of thermosetting resign treated high pressure ,self- supporting decorative compact laminates with permanently incorporate anti-bacterial agents during manufacturing . Compact board should be resistance to water immersion through permissible increase on thickness and mass <0.60% and board density >1.35kg/cm3 and fulfilled the criteria of FSC and green guard gold certification and manufactured under EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant ,Scratch resistant ,Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS- 476/97 and EN438-6 with classification of BS1D0 standard. Pilaster to be supported with SS(grade316)adjustablefoot and intermediate panels will attached to the wall withthe help ofapproved SS (grade316) channels and all requiredhardware, made up of stainless steel asThe top fitting should consist of SS round top rail which will get fixed with pilaster, with SS panel tube holder ,SS corner bend (connected with top rail ) will be use in corner of cubical in absence of brick wall, SS wall fixing is used only on the wall which will hold the SS top rail. All screw will of 304 grade in SS with stain finish. All pilasters are supported by SS bottom cladding . The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 150 mm.Finish and colour of Toilet cubical should be approved under guidance of engineer-in- charge.• Toilet cubical with standard dimension of 2025 mm(H) x 900mm(W) x 1500mm(Depth), which includes 600mm door size width• Toilet cubical I- shape(front partition) with standard dimension of 2025mm(H) x 900mm (W) |
| 48 | Providing & fixing Urinal Modesty Panels made of 12 mm thick compact laminated board of approved texture/shade having standard dimension of 1200 mm Height x 450 -500 mm Width and made as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard and should be heat, bacteria, water, chemical, scratch and impact resistant . The product should have Green Guard Certificate. Including all accessories as per approval and direction of Engineer- in-Charge .Modesty panels will be fixed to the wall at an height of 500-600mm from the floor with 304 grade SS right angle bracket, 34 grade SS Screws with satin finish & Wall Plugs.The work includes all accessories, machineries, tools etc., complete as per direction of Engineer- in- charge. |
| 49 | 10)-WATERPROOFING :-A)-RAFT/FOOTING :- Supplying and installing minimum 1.2mm thick self-adhesive HDPE membrane, having puncture resistance of >800N (as per ASTM E 154) and hydrostatic head resistance not less than 60m head of water (ASTM D 5385).The system should be fully bonded to the RCC and consists of highly resilient HDPE film, a pressure sensitive -adhesive layer which is covered by a weather proof protective layer .The membrane shall have minimum of 75mm side and end laps which shall be sealed with double sided adhesive tape. The size of the membrane should not be less than 2.4Mtr. x 20 Mtr. to minimize the joints. No Protection Required for Fully Bonded HDPE Membrane Allowing Faster Constructions. The entire waterproofing treatment should be guaranteed by the principal manufacturer as a system, for ten years and the work should be executed as per manufacturer commendations, all in accordance to technical specification as per the direction of Engineer-In-Charge. |
| 50 | B)- TOILETS/SUNKEN TOILETMinor cleaning work, removal of loose concrete and filling cracks and making angle fillets all around the periphery with polymer modified mortar using SBR latex. Supplying & applying 2 coats of Acrylic cementitious coating with an elongation of >40%@ 0.6-0.7 sq mtr per kg in two coats in the sunken areas & extending it up to 300 mm above the finished floor level achieving a uniform thickness of 1.0mm . This includes laying of a 150mm wide strip of an open woven glass fiber mesh over the angle fillets on the 1st coat while it is still wet Supplying & laying a protective plaster in 15mm thickness in Sand Cement mortar(1:4) admixed withSBR Latex mixed compound, all in accordance to techincal specification as per the direction of Engineer-In-Charge. |
| 51 | C)-TERRACESupplying and apply single component cold applied polyurethane elastomeric membrane, having solid content 90% as per ASTM C836,elongation at break of 400% ASTM D-612, hardness 75 shoreA, as per ASTM D2240 @1 kg/m2, brush applied waterproofing coating,Providing & Laying a protection layer of 200 gsm geo-textile membrane with an overlap of 50mm over the waterproofing membrane. |
| 52 | Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like |
| 53 | STAMPING TABLESupplying and placing Stamping Table, comprising of 18mm thick Particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes , 30x30 mm framework of salwood, laminate of approved make fixed over particle board at all sides by using adhesive of approved quality, at top lipping to be made at edges with 100mm high deep drawer at front with channels and hardware.,, all complete as per design/drawing in the direction of Engineer- in-Charge. |
| 54 | STAMPING STANDSupplying and placing Stamping stand, comprising of 18mm thick Particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes , 30x30 mm framework of salwood, 4mm veneer board of approved make fixed over particle board at top and all around of stamping stand by using adhesive of approved quality,, all complete as per design/drawing in the direction of Engineer-in-Charge. |
| 55 | FRISKING BOOTHSupplying and placing Frisking Booth, comprising of 18mm thick Particle board at all sides of cabin of approved make confirming to IS code 3087:2005 or other relevant IS codes , 50x50 mm framework of salwood, 4mm veneer board of approved make fixed over particle board on both sides of the booth by using of adhesive of approved quality, stainless steel rod of 20mm dia fixed at top of rare and front ends of cabin with curtains, all complete as per design/drawing in the direction of Engineer-in-Charge. |
| 56 | INFORMATION DESKProviding and fixing in position Information Desk, comprising of 12mm thick plywood of approved makes, confirming to IS 303 : 1989 or other relevant IS codes, framing of salwood, solid acrylic surface is fixed over plywood by using adhesive of approved quality at countertop, sides of desk as shown in the drawing including all necessary cutouts for electrical, fixtures, fittings etc. all complete as per the direction of the Engineer-In-Charge. Overall approx. Size 1500(L) x 1500(B) x 2400(H) mm |
| 57 | BOARDING PASS COUNTER:-Providing and fixing in position boarding pass counter, comprising of 12mm thick plywood of approved makes, confirming to IS 303 : 1989 or other relevant IS codes, 30x30 mm framework of salwood, 4mm veneer is fixed over plywood by using adhesive of approved quality at countertop, sides of desk as shown in the drawing including all necessary cutouts for electrical, fixtures, fittings etc. all complete as per the direction of the Engineer-In-Charge. Overall approx. Size 1000(L) x 875(B) x 1080(H) mm |
| 58 | LUGGAGE TABLESupplying and placing Luggage Table, comprising of 18mm thick particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes over 30x30mm framework of salwood, 40 x 40 mm wooden table legs, beveled at edges. all complete as per design/drawing in the direction of Engineer-in-Charge. i-Overall approx. size 750(L) x 1525(B) x height as per x ray machine height |
| 59 | LUGGAGE TABLESupplying and placing Luggage Table, comprising of 18mm thick particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes over 30x30mm framework of salwood, 40 x 40 mm wooden table legs, beveled at edges. all complete as per design/drawingin the direction of Engineer-in-Charge.ii-Overall approx. size 900(L) x 600(B) x height as per x ray machine height |
| 60 | VIP LOUNGE Furniture Jinerio 3strSupplying and placing in position 3 Seater sofa of the following specifications.Upholstery : Microfibre with Polyester Laminate Frame Material : Kiln dried wood Seat Foam : Slab stock foam with recron layer. Also bonded foam used as a supporting material beneath slab stock. Foam Density : 34 kg/ cubic m. Back Foam : Slab stock foam with recron fill at back and arms. Foam Density : 34 kg/cubic m. Webbing Material : S- spring along with nylon strips. The overall dimension of the sofa shall be 2110 mm(W) x 935 mm (D) X 890mm (H).The upholstery is made of fabric. The seat and backrest is filled with recron. The frame is made up of tropical wooden. |
| 61 | Jinerio 2strSupplying and placing in position 2 Seater sofa of the following specifications.Upholstery : Microfibre with Polyester Laminate Frame Material : Kiln dried wood Seat Foam : Slab stock foam with recron layer. Also bonded foam used as a supporting material beneath slab stock. Foam Density : 34 kg/ cubic m. Back Foam : Slab stock foam with recron fill at back and arms. Foam Density : 34 kg/cubic m. Webbing Material : S- spring along with nylon strips. The overall dimension of the sofa shall be 1560 mm(W) x 935 mm (D) X 890mm (H).The upholstery is made of fabric. The seat and backrest is filled with recron. The frame is made up of tropical Wooden. |
| 62 | Mackenzie 1 strsize1 seater-107cm(w)*101cm(d)*103cm(h)*51cm(sh) Upholstery : Fab leather. A fabric which gives a leather feel• Thickness of upholstery: 1 mm• Shade:1 seater - Dark Brown and blue 2 seater + storage – Dark Brown 2 seater – Dark Brown• Mechanism :Manual with there level reclining in metal• Frame : Material- Solid wood Moisture Content : 12%• Foam Density : Seat : 32 kg/ cubic meter Back : 28 kg/ cubic meter |
| 63 | Gayle Centre TableSupplying & placing in position oval shaped centre table of dimensions 1100 x 600 x 395.Tempered Glass Top with 8mm thickness. UV disc attached to the base with transparentglue. Base material is made of fibreglass reinforced plastic. Load bearing capacity : 40 Kg. Colour to be black. |
| 64 | Vegas Corner TableOverall Size including top cornice:Width (a)- DIA450-mm .Thickness (b)- 9 mm.Height (c)- 520 mm. D – 450mm Material : Temper glass ,thickness:9mm ;coating:chrome |
| 65 | Supply of 30.5M Flag mast. Mast shaft shall be in three sections, hot dip galvanised and suitable for wind velocity as per IS 875.Mast shall be suitable for Indian Tri Color Flag Size 30Ft X 20Ft.System for Raising Lowering of Flag It shall have double drum winch, 6 mm dia Galvanised wire rope and integral power tool for the raising and lowering of Flag.Supply of system with 3C x2.5sqmm Cu armoured cable for aviation light. PU painting of High mast shaft with a coating of etch primer, and PU Paint. |
| 66 | Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates. |
| 67 | Supply of Aviation Lamp Single Dome Obstruction light.1 nos. LED AOL per mast |
| 68 | Supply of 5M high hot dip galvanised octagonal pole suitable to mount 2 nos.flood light fitting at top. |
| 69 | Supply of national flag of size 30Ft X 20Ft in 100% knitted Polyester (140gsm), with reinforced super-strong nylon webbing on all 3 sides & rope/toggle sleeve. |
| 70 | ERECTION PARTErection of the Flag Mast with the help of suitable equipments and assembly of operating system and Flag supplied by you. |
| 71 | 2-CONCRETE:- Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (more than 10 ton) |
| 72 | Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 350 Kg/Cum.“Excess/ less cement used as per design mix is payable/recoverable separately). (All work above plinth level upto floor V level) |
| 73 | 4-FLOORING:- Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge With granite stone of colour black, cherry/ruby red of area |
| 74 | A)-CIVILWORK,1)-EARTHWORK:- Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or softsoil |
| 75 | Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B)Dense or Hard soil |
| 76 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each dispositedlayer by ramming and watering |
| 77 | Add extra for Disposing off the excavated stuff of above items for lead of(A)50 m to 100 m |
| 78 | Add extra for Disposing off the excavated stuff of above items for lead of(A)100 m to 200 m |
| 79 | Add extra for Disposing off the excavated stuff of above items for lead of(A)200 m to 300 m |
| 80 | Add extra for Disposing off the excavated stuff of above items for lead of(A)300 m to 400 m |
| 81 | Add extra for Disposing off the excavated stuff of above items for lead of(A)400 m to 500 m |
| 82 | 2)-CONCRETE:- Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth |
| 83 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum i-All works upto plinth level |
| 84 | (B)-ELECTRICAL INTERNAL,1-Wiring:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 85 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 86 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 87 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 88 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVCinsulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. |
| 89 | 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. |
| 90 | 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire |
| 91 | 2x10 sq. mm + 1x6 sq. mm earth wire |
| 92 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 93 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 94 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet (near equipment point) and 25 A modular SP MCB, “C” curve (at accessible point) including connections, painting etc. as required. |
| 95 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or c utting the wall and making good the same in case of recessed conduit as required. a- 20 mm |
| 96 | 25 mm |
| 97 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75 mm x 75 mm) (For Telephone, Data, TV Outlets) |
| 98 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 99 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 100 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair |
| 101 | 2 Pair |
| 102 | 4 Pair |
| 103 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 104 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 105 | 2)-Fans and Fittings:- Supply, Installation, Testing and Commissioning of following fittings on the existing point with making connection with 1.5 sqmm FRLS Copper conductor single core cable i/c earthing etc. As required.Note: All LED Fixtures shall have power factor ≥0.90 (For item No 1 to 5)Supply of Surface/recess type LED (direct/indirect) of 595 x 595 mm size with aesthetically designed extruded aluminium housing & injection molded PC component diffuser with efficacy better than 120 Lumen/watt (minimum total lumen delivered package 4800), with CCT=3000/4000/5000 K,PF>0.95,THD<10% & with Driver having efficiency >85% .Service life of 50,000 hrs @ L 70 etc complete as required. (Driver complaince IEC 62384,IEC 61547,IEC 61347-2-13,EMI-CISPR15) |
| 106 | Supply of Surface/recess type LED downlighter neutral white (4000 K) with LED having pressure die cast aluminium hang body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50000 hrs having system lumen output better than 1000 lumens and efficacy better than 100 lumen/ watt(fixture design for meeting LG-7 Guideline) with CRI>80, Reverse Polarity and Surge Protection upto 3 kV& Driver efficiency> 90%,PF>0.98,THD<5% (Driver complaince IEC 62384,IEC 61547,IEC 61347-2-13,EMI-CISPR15) etc. complete as reqd. |
| 107 | 1200/1400 mm sweep BLDC ceiling fan providing minimum air delivery of 270 Cu Mtr/Minute with power consumption not more than 42 watts at the speed of 270 RPM,service value greater than 7, complete in all respect Powder coated Aluminium die cast body & blades(minimum 1 mm thick aluminium leaf), Power factor not less than 0.90 including providing 6 key remote alongwith necessary down rod of standard length (upto 30cms) |
| 108 | 900 mm sweep BLDC ceiling fan providing minimum air delivery of 270 Cu Mtr/Minute with power consumption not more than 42 watts at the speed of 270 RPM,service value greater than 7, complete in all respect Powder coated Aluminium die cast body & blades(minimum 1 mm thick aluminium leaf), Power factor not less than 0.90 including providing 6 key remotealongwith necessary down rod of standard length (upto 30cms) |
| 109 | Supply ,Installation , testing ,Commissioning AC Exhaust Fan 300mm (12\") Sweep (Light Duty).All complete complying with relevant standard specification and as directed by the departmental officers. |
| 110 | 10W Mirror Light |
| 111 | 70W LED DOWN LIGHTER SURFACE MOUNTED |
| 112 | 3)- Distribution Boards:- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Double door |
| 113 | 6 way, Double door |
| 114 | 8 way, Double door |
| 115 | 12 way , Double door |
| 116 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door SPN MCBDB |
| 117 | For 8 way, Double door SPN MCBDB |
| 118 | For 12 way, Double door SPN MCBDB |
| 119 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 120 | Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required.40 Amp |
| 121 | Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.40 Amp |
| 122 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 123 | (C)-Electrical External,1) Main External Lighting:-Supply, Installation, Testing and Commissioning of cubicle type LT panel, IP55, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system fabricated in compartmentalized modular design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars for high conductivity, DMC/SMC bus bar supports,with short circuit withstand capacity of 35 KA for 1 sec, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main bus bar to switchgears and from switchgear output to cable termination in cable alley with required size of AL conductors / bus bars and control wiring with 2.5 sqmm PVC insulated copper conductor cable (FRLS), cable alleys, cable gland plates in two half, i/c providing following switchgears / accessories as per specifications.INCOMER2 Nos. 160 Amp, 4P Moulded Case Circuit Breaker (Ics = Icu = 35 KA) with thermal magnetic based release with built in O/L & S/C release & CBCT with E/F module or with earth fault relay protection with Individual LED for fault indication for each fault.1 No. Automatic Transfer Switch (ATS) 160 Amp 4 Pole for 415V, 50hz supplyIncomer shall have the following items: Intelligent Multifuntion Meter ( with Voltage, Current & Frequency) with selector switch and one set of 3 nos. CTs of ratio 160/5A , Class I accuracy and 15 VA burden- 1set. 3 Nos. Indication lamp OFF/ON/TRIPwith 2 amp back up MCB. BUSBARS: TPN aluminium bus bars of minimum 200 Amps capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25 KA for 1 sec. OUTGOING: Five (5) Nos. 63 Amp4P MCCB (25kA), Main External Lighting Panel- described as above |
| 124 | External Feeder Pillar: (Weather proof type) IP-55 (Double Door)INCOMER1 Nos. 63 Amp, 4P Moulded Case Circuit Breaker (Ics = Icu = 25 KA) with thermal magnetic based release with built in O/L & S/C release & CBCT with E/F module or with earth fault relay protection with Individual LED for fault indication for each fault.1 Nos. 40 Amp TPN MCB 10kA .1 Nos. 63 Amp 4 Pole MCB 10kA .1 Nos. 70 Amp 4 Pole Contactor and 1 Nos. Timer for Automatic Operation.Intelligent Multifuntion Meter (with Voltage & Current) with selector switch and one set of 3 nos. CTs of ratio 60/5A , Class 1 accuracy and 10 VA burden- 1set.2 Nos.phase indicating LED lamps each with 2 amp back up MCB. 2 Nos. Indication lamp OFF/ON/TRIP with 2 amp back up MCB. BUSBARSTPN aluminium bus bars of minimum 100 Amps capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25 KA for 1 sec.OUTGOING25 Amp 4P MCB(10kA) - 5 Sets25 Amp DP MCB(10kA) -12 Sets10 Amp SPN MCB (10 KA)- 8 Sets |
| 125 | Lighting FixtureSupply , Installation, Testing & commissioning of the followings:-Post top (Gate Light) luminaire with system wattage 27W. The luminaire shall be with BIS certification for Luminaire on 3.0M GI Pole. |
| 126 | Street Light luminaire with system wattage 65W.The luminaire shall be with BIS certification for Luminaire. |
| 127 | LED BOLLARD with system wattage 8-11W & high level of durability with high impact resistance.The luminaire shall be with BIS certification for Luminaire. |
| 128 | LED Spike light with high level of durability with high impact resistance. The luminaire shall be with BIS certification for Luminaire. |
| 129 | Poles - Supply & Erection of 7.5 Mtr. high (above Ground) GI OCTAGONAL street light pole alongwith bracket and all accessories in reinforced cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation of size 40x40x150 cm, including excavation and refilling, positioning of template & foundation bolts (supplied with pole to match with pole base plate) & providing and fixing of DWC HDPE pipe of size 50 mm dia (2 pieces of min. 0.75 m length) in the foundation for loop-in-loop-out of the cable to the pole i/ccableterminationetc complete as required. (For street Light Single Arms) |
| 130 | 2)- LT CABLE AND TERMINATION- SSupplying & laying one number XLPE insulated PVC sheathed Aluminium/Cu Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI/Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in airetc. as requred. 3.5 core, 50sq.mm. |
| 131 | 3.5 core,35sq.mm. |
| 132 | 3.5 core,25sq.mm. |
| 133 | 4 core,10 sq.mm. Cu |
| 134 | 4 core,6 sq.mm. Cu |
| 135 | 4 core,4 sq.mm. Cu |
| 136 | 3 core,6 sq.mm. Cu |
| 137 | 3 core,2.5 sq.mm. Cu |
| 138 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.3.5 core,50sq.mm. |
| 139 | 3.5 core,35sq.mm. |
| 140 | 3.5 core,25sq.mm. |
| 141 | 4 core,10 sq.mm. Cu |
| 142 | 4 core,6 sq.mm. Cu |
| 143 | 4 core,4 sq.mm. Cu |
| 144 | 3 core,6 sq.mm. Cu |
| 145 | 3 core,2.5 sq.mm. Cu |
| 146 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150mm dia RCC pipe |
| 147 | 3)-EARTHING SYSTEM- Supply, installation, testing and commissioning of followings :- Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. |
| 148 | Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 149 | Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: 25 x 6 mm strip |
| 150 | 6 SWG wire |
| 151 | D)-Plumbing -1-SANITARY FIXTURE & FITTINGS:- Supplying, Installation, Testing and Commissioning white vitreous china wall mounting water closet of approved shape including seat cover, and fittings, nuts, bolts and gasket etc complete including cutting and making good the wall wherever required. |
| 152 | Supplying, Installation, Testing and Commissioning of twin flush concealed cistern with knob and frame and fittings, nuts, bolts and gasket etc complete including cutting and making good the wall wherever required. |
| 153 | Supplying, Installation, Testing and Commissioning Table top wash basin with C.I. brackets with waste of standard pattern with waste fitting, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 480x300mm. |
| 154 | Supplying, Installation, Testing and CommissioningC.P. Pillar cock with aerator including cutting and making good the wall wherever required. |
| 155 | Supplying, Installation, Testing and Commissioning white vitreous battery based infrared sensor operated urinal of approx. size 360 x 330 x 740 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 156 | Supplying, Installation, Testing and Commissioning urinal partition of size 90x320x720 mm deep. including cutting and making good the wall wherever required. |
| 157 | Supplying, Installation, Testing and CommissioningC.P. Bottle Trapincluding cutting and making good the wall wherever required. |
| 158 | Supplying, Installation, Testing and Commissioning ofsurface mounted satin-finish type 304 stainless steel jumbo roll toilet tissue dispenser complete. |
| 159 | Providing, fixing, Testing and Commissioning of CP brass two waybib cock with wall flange including, necessary flange, cutting and making good he walls / floors wherever required complete. |
| 160 | Providing and fixing health faucet with 1 m ss braided hose pipe and swivel hook including all fittings complete. |
| 161 | Supplying, Installation, Testing and Commissioning bright polish stainless steel surface mounted dual coat hookscomplete. |
| 162 | Supplying, Installation, Testing and Commissioning of Towel Ring fixedwith CP brass screw complete. |
| 163 | Providing, fixing, Testing and Commissioning surface mounted soap dispenser with horizantal tank , corriosion resistant valve dispense and 1.2 litre capacity soap refill window including cutting and making good the wall wherever required. |
| 164 | Providing, fixing, Testing and Commissioning bib cock with wall flange and areator of approved quality colour and makeincluding cutting and making good the wall wherever required. |
| 165 | Supplying, Installation, Testing and Commissioning 5mm thick glass mirror including cutting and making good the wall wherever required. |
| 166 | Supplying, Installation, Testing and Commissioning of Jet speed hand dryer, 1750 Watt Power, Auto turn off including cutting and making good the wall wherever required. |
| 167 | Supplying, Installation, Testing and CommissioningC.P. angle cock with wall flange including cutting and making good the wall wherever required. |
| 168 | Supplying, Installation, Testing and Commissioningpolyamid connection pipe including cutting and making good the wall wherever required. |
| 169 | Supplying, Installation, Testing and Commissioning of Cruse set including EWC (European type water closet) size 710 X 370X 810mm with cistern, soft close seat cover, flush fittings, wash basin( 510 x 400mm ), lever arm faucet for ease of operation, 2 nos. wall mounted grab bar, 1 no. wall mounted hinged hand rail fixed to wall with brackets including cutting and making good the wall and floors as required. . (IN SPECIAL NEEDS RANGE) (Divyang Toilet) |
| 170 | Supplying, Installation, Testing and Commissioning of classic series surface mounted sanitary bin with satin finish stainless steel.Door has key lock. Self-closing panel covers disposal opening.Removable,leak proof,4.5 L Plastic bin. including cutting and making good the wall wherever required. (in ladies toilet) |
| 171 | Supplying, Installation, Testing and Commissioning of surface mounted sanitary disposal bag dispenser with satin finish stainless steel. Equipped with concealed locking device. Concealed wall plate 0.8 mm (22-gauge) type 304 stainless steel. Hold one pack of 25 two ply plastic bags. including cutting and making good the wall wherever required. (in ladies toilet) |
| 172 | Supplying, Installation, Testing and Commissioning of surface mounted satin finish type 304 stainless steel, Trimline recessed paper towel dispanser,leak proof waste bin, hand dryer complete as required. |
| 173 | Supplying, Installation, Testing and Commissioning of Water cooler made of pure Stainlesssteel body, without rusting , without corrosion. including externallly mounted thermostat to make it easy to set water temperature, wth extra large SS wate tray prevent spalashing and ensures fast drainage of water , aoto cut facilitie , over load compressor protection, electricl supply internal wiring etc. to complete the work. |
| 174 | Providing, fixing, Testing and Commissioning automatic Aerosol Dispenser with wooden cleats and C.P. brass screws including cutting and making good the wall wherever required |
| 175 | 2)- SOIL, WASTE & VENT100 mm dia-Hubless Centrifugally cast (Spun) ironpipes epoxy coated inside and outside IS:15905 |
| 176 | Providing and bend of required degree with access door, insertion rubber washer 3mm thick , bolt and nut complete 100mm dia - Hubless Centrifugally cast (Spun) ironpipes epoxy coated inside and outsideIS:15905 |
| 177 | Providing and fixing plain bend required degree 100 mm dia -Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outsideIS:15905 |
| 178 | Providing and fixing plain bend required degree 75 mm dia - Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outsideIS:15905 |
| 179 | Providing and fixing double equal plain junction of required degree100x100x100x100mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905 |
| 180 | 75x75x75x75mm-Hubless Centrifugally cast (Spun) ironpipes epoxy coated inside and outside IS:15905 |
| 181 | Providing and fixing single equial plain junction of required degree100x100x100mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905 |
| 182 | 75x75x75mm-Hubless Centrifugally cast (Spun) ironpipes epoxy coated inside and outside IS:15905 |
| 183 | Providing and fixing shielded coupling for hubless centrifugally cast iron pipe i-150mm dia - SS- 304 grade coupling with EPDM rubber gasket |
| 184 | 100mm dia -SS- 304 grade coupling with EPDM rubber gasket |
| 185 | Providing and fixing single unequial plain junction of required degree150x150x100mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905 |
| 186 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling andfloor. (internal work). a)-32mm dianominal bore |
| 187 | 40mm dianominal bore |
| 188 | 50mm dianominal bore |
| 189 | providing and Fixing trap of self cleansing design with screw down or hing grating with or without arm completeincluding cost of cutting and making good walls and floors 100 mm dia inlet and 100mm dia outlet-Hubless Centrifugally cast (Spun) ironpipes epoxy coated inside and outside IS:15905 |
| 190 | Providing and fixing cast bronze cleanout plug brass screws, male threaded joint with G.I socket coupled to CI hubless pipe including jointing etc. complete in all respects.100 mm dia |
| 191 | Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32, 40 0r 50 mm size fabricated from 100 mm dia G.I. Pipes (Medium class)and welded G.I. Sockets, fixed to C.I. Trap with lead caulked joint and set in cement concrete as per standard drawing etc. complete in all respect. |
| 192 | Providing and fixing SS grating of approved quality and colour. Circular type 124 mm nominal dia with 25 mm waste hole. |
| 193 | 3-RAIN WATER- Providing, fixing, jointing and testing in position the following UPVC pipes confirming to IS:4985 of 6 Kg / Sq.cm for drainage system cut to required length including all necessary fittings and specials such as bends, junction, offset, access pipe (plain or door) and vent cowl fixing wall / ceiling level supported by GI clamps, hangers, etc.. and making good the same complete as required. (For Rain Water).110mm diameter |
| 194 | Making Khurra 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C sheet 1m x 1m x 400 microm, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edage and making and finishing the outlet complete. |
| 195 | 4-INTERNAL WATER SUPPLY-Providing and fixing concealed center point to wall ceiling & floor CPVC(SDR13.5)PIPEhavingNationalSanitationFoundation(NSF)sealforpotablewaterof following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [Bl 20 mm.Internal work - Concealed Pipe a-15mm nominal outer dia. Pipes. |
| 196 | 20mm nominal outer dia. Pipes. |
| 197 | 25mm nominal outer dia. Pipes. |
| 198 | 32mm nominal outer dia. Pipes. |
| 199 | 40mm nominal outer dia. Pipes. |
| 200 | 50mm nominal outer dia. Pipes. |
| 201 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(A) 15mm (upto 10 ton) (internal work).Internal work - Exposed on wall 15mm (a) nominal outer dia. Pipes. |
| 202 | 20mm (B) nominal outer dia. Pipes. |
| 203 | 25mm (C) nominal outer dia. Pipes. |
| 204 | 32mm (D) nominal outer dia. Pipes. |
| 205 | 40mm (E) nominal outer dia. Pipes. |
| 206 | 50mm (F) nominal outer dia. Pipes. |
| 207 | Providing & fixing brass stop cock of approved quality . 15mmdia nominal bore |
| 208 | 20mmdia nominal bore |
| 209 | Providing and fixing gunmetal gate valve with CI wheel of approved quality (Screwed end) a- 25mm nominal bore |
| 210 | 20mm nominal bore |
| 211 | Providing & fixing Auto Air vent for water supply risers, suitable for pressure not less than 15 Kg/Sq.cm. 25 mm dia |
| 212 | 5-SEWERAGE & DRAINAGE SYESTEM- Providing and laying (to level or slopes) and jointing with stiff mixture of Cement Mortar in proportion 1:1 Seit glazed stoneware pipes including testing of pipes and joints complete.150 mm (B) diameter (upto 10 ton) |
| 213 | Providing and laying Cement concrete 1:5:10 (1-Cement: 5-Fine sand :10-Graded stone aggregate 40mm nominal size) bedding for stoneware pipes of following internal diameters with necessary formwork and curing complete.(B) 150mm dia.(166mm Ave.bed thickness) 150mm dia SWpipe (B) |
| 214 | Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside} with standard weight.(i} Square mouth traps. 150x100 mm size P type(upto 10 ton} |
| 215 | Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement: 3-coarse sand :6- Brick bats 40 + 50mm size) inside plastering15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4- stone aggregate 20mm nominal size) finished smooth complete including curing and testing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strengthnotlessthan 35Kg./ Sq.cm. in Cement Mortar 1:5(1- Cement: 5-Coarse sand) (1) Atypedepth0.90 |
| 216 | (I) Extraratefor constructing B.B. masonry forevery additional depth of O.lM. or Part thereof over itemNo.24.27 (I) for depth from 0.9M to 1.5M. |
| 217 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 218 | Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.150 mm diameter |
| 219 | Constructing Brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating wih frame complete. (upto 10 ton) |
| 220 | Boring with hydraulic piling rigs with power Units, providing and installing cast - in situ piles of 400mm diameter and length below plinth beam in M-30 Cement Concerete, to carry asafe working load not less than specified, exculuding cost of steel reinforcement and Concretebut including the cost of boring and the length of the pile in plinth beam etc. all complete. (length of pile for payment shall be measured upto the bottom of plinth beam). |
| 221 | Water FountainProviding and fixing water fountain of OASIS Model VERSAFILLER P8SBFSLY including in all respect and as per direction of EIC |
| 222 | Mezzanine Floor AHU CoverProviding and Fixing of 1 mm thick Alluminium sheet with framing for the AHU cover including in all respect and as per direction of EIC |
| 223 | Providing and fixing aluminium perforated jali made out of aluminium sheet of approved make and quality, minimum thickness 1.6 mm (or as specified), with uniform perforation pattern as approved by Engineer-in-Charge, including cutting tProviding and fixing aluminium perforated jali made out of aluminium sheet of approved make and quality, minimum thickness 1.6 mm (or as specified), with uniform perforation pattern as approved by Engineer-in-Charge, including cutting to required size, bending, edge finishing, drilling, and fixing in position on aluminium / MS frame or wall with SS screws / aluminium rivets, including necessary supports, clamps, fasteners, backing plates, and all complete as per CPWD specifications, architectural drawings and directions of Engineer-in-Charge.o required size, bending, edge finishing, drilling, and fixing in position on aluminium / MS frame or wall with SS screws / aluminium rivets, including necessary supports, clamps, fasteners, backing plates, and all complete as per CPWD specifications, architectural drawings and directions of Engineer-in-Charge. |
| 224 | Providing and fixing false ceiling at all height including providing and fixing of frame workmade of special sections, power pressed from M.S. sheets and galvanized with zinc coatingof 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre,one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm diabolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required lengthwith nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I.channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which theceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm eachhaving lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicularto G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high havingflanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the helpof rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, includingfixing of gypsum board to ceiling section and perimeter channel with the help of dry wallscrews of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish oftapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of jointand two coats of primer suitable for board, all as per manufacturer’s specification and alsoincluding the cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specification anddirection of the Engineer in Charge but excluding the cost of painting with :12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Boardwith BIS certification marks) |
| 225 | Providing, fabricating and supplying and fixing panels of aluminium composite panelcladding in pan shape in metalic colour of approved shades made out of 4mm thickaluminium composite panel material consisting of 3mm thick FR grade mineral coresandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium compositepanel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon basedfluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service)coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats,weather silicone sealant, backer rods etc |
| 226 | Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 finesand) including testing of joints etc. complete |
| 227 | Providing New Electricity 1000KVA HT Connection including Service Line Charges, Security Deposit, Test Report Charges etc. at Terminal Building, Daman Airport. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail