| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Clearing jungleincludinguprootingof rank vegetation,grass,brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 4 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 8 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 12 | Foundations,footings,basesof columns,etc.formass concrete |
| 13 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 14 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 15 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 16 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 17 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking withpushandpull operationcomplete,including thecost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 18 | 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 19 | Providing and fixing ball bearing for rolling shutters. |
| 20 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 21 | G.I. pipes |
| 22 | 12 mm cement plaster of mix: |
| 23 | 1:4(1 cement: 4 fine sand) |
| 24 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 25 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 26 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 27 | Two or more coats on new work |
| 28 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 29 | 80 mm nominal bore |
| 30 | Supplying pig lead at site of work. |
| 31 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : |
| 32 | 100 mm diameteri) Class I |
| 33 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equalavent(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping aluminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 34 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets accessories 0.50 mm (+0.05 %) total coated thickness, with aluminium Zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. |
| 35 | Ridges plain (500 - 600mm) |