| 1 | Dismantling fencing wire mash any type complete all as specified and directed. |
| 2 | Dismantling posts/pillers or struts (Wood, Steel, or RCC) any section, including taking out embedded portion post embeded in concrete and making good disturbed ground complete all as specified and directed. |
| 3 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as specified and directed. |
| 4 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 5 | Excavating in post holes (or similar holes) each n exc0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc50m and making good surface complete all as specified and directed. |
| 6 | M&L PCC 1:3:6 type C2 using 40 mm graded stone aggr as in foundation filling and mass concrete complete all as specified and directed. |
| 7 | S&F Mild steel TMT round bars 10 mm dia and over, cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and bindingwith and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 8 | S&FMS angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conformingcomplete all as specified and directed. |
| 9 | Supply only Mild steel in flat, roundbars, in available lengths quality con-forming to Fe- 290 (Gde E- 165) complete all as specified and directed. |
| 10 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm long but n exc 10 cm & dia of neck 11 to 15mm complete all as specified and directed. |
| 11 | Supply only3.15mm dia GI wire 108x108 mm mesh (chain link fencing) made up to mattresses or cages lapped wired and laid in position including closing and tied withposts properly complete all as specified and directed. |
| 12 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining 10 mm dia steel bar, bolts, etc. including provision of binding wire complete all as specified and directed. |
| 13 | S&Fin repairs Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type or standard rails straining balte, including securing or tying at crassing with provision of Galvanised mils steel wire staple pine etc as directed (each line wire to be mesured) complete all as specified and directed. |
| 14 | S&F Concertina coil reinforced punch (crome razor of blade wire ) with bardbed tap 0.5 mm thick galvanized steel sheet and core wire of dai 2.5 mm high tensile steel wire of concertina coil fencing with punched tape 450 mm dia having 45 nos round per 6m length includind taking out oldwire coplete. |
| 15 | M&Lfor preparation of newsteel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxideprimer and applyinng 2 coats of synthetic enamel paint of approved shade complete all as specified and directed. |
| 16 | M&Lfor preparation of oldsteel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxideprimer and applyinng one coats of synthetic enamel paint of approved shade complete all as specified and directed. |
| 17 | M&L brick work with sub class \"B\" brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 |
| 18 | Description all as per ser item No 17 above, but except bricks |
| 19 | Taking down cement plaster on wallof any description incl racking out joints hacking for key and scrubbing down with water complete. |
| 20 | M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement ) complete |
| 21 | M&L three coat of white wash on newly preparedsurfaces on wall , etccomplete. |
| 22 | M&L three coat of white wash on old surfaces on wall , etccomplete. |
| 23 | M&L Cement concrete inin eight,copings, kneelers, apex stones, bed plates, kerbs (1:2:4) type B-1( 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismi cand other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight,copings, kneelers, apex stones, bed plates, kerbs |
| 24 | M & L forRCC cable route indicator of size 800 x 350 x 50 MM (Top of indicator in semicircle shape) dully marking by synthetic enamelled paint inBlue coulor forMES LT cable1.1 KV and Red colour of MES HT cable 11 KV and also markMES, grouting in PCC making good complete all as directed.Note - Earth work and PCC work to be measured in respective items here- in- before. |
| 25 | M&L Repair to existing brick masonry cable duct, including removal of loose and damaged bricks, dismantling cracked portions, re-building in sub-class ‘B’ bricks in cement mortar 1:6, internal plastering 15 mm thick in CM 1:4, refixing or replacing covers, curing and making good disturbed surfaces, complete all as specified and directed. |
| 26 | M&L for Arranging and operating approved cable route tracing machine including transmitter, receiver and all accessories, with skilled operator and helper, for tracing and identifying the route of existing underground LT / HT electrical cable in connection, including marking the traced route on ground, testing of equipment before use and reporting to Engineer-in-Charge. Excavation, fault locating and cable repair shall not be included. Complete all as directed.Note :The cable route tracing machine for detecting cable route will be arranged by the Contractor |
| 27 | Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6.3mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip 25 mm x 4 mm by means of GI bolts, nuts, check nuts and washers and earth strip protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Cement Earth pit and pit cover, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03.Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desied earth result not found during testing of the same at site. |
| 28 | M&L earth continuity conductorGI of 25 x 4 mm of GI strip fixed by means of bolts, nuts, check nuts and GI washers complete all as specified. |
| 29 | M & L for filling and spreading aggregate using 40 mm grade stone aggregate around 4 pole/ 2 pole structure, LT panels and transformer etc. complete all as specified and directed. |
| 30 | Material and labour in replacement of existing rusted danger notice board with pressed vitreous painted plate fabricated out out of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamp bolts and nuts of approved size 20 X 15 cm size complete all as specified and directed. |
| 31 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for ducts & mass concrete including necessary form work and fair finishing completeall as specified and directed by Engineer-in-charge |
| 32 | Supply, laying, jointing and testing XLPE insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5 core X 50Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed. |
| 33 | Description all as per ser item No 32 above, but size 3.5 core X 35 sqmm |
| 34 | Description all as per ser item No 32 above, but size 4 core X 25 sqmm |
| 35 | Description all as per ser item No 32 above, but size 4 core X 16 sqmm |
| 36 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in hard /dense soil complete all as specified and directed. |
| 37 | Returning filling in including spreading, leveling, Watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 38 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 39 | M & L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 08cm before laying the cable & 15cm after laying the cable complete all as specified and directed. |
| 40 | Material and labour for laying bricks \"B\" class over a cable (Width wise) old laid dried complete all as specified and directed. |
| 41 | Supply and fix in replacement ofautomatic timer switch pole mounted enclosure consisting of ON/OFF switch based on LUX level, power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as directed. Make : SUGAM/-54-18KW3PSUGAM series with NS smart Sensor.Note: (i)Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate.(ii) Provn of glands and lugs shall be deemed to be included in the quoted rate. |
| 42 | Trimming of Tree Branch, girth not exc. 150 mm around OH Electric Lines and cleaning , removing trimmed Branches from Site(s) and stacking as ordered, complete all as specified and as directed. |
| 43 | M&L Cleaning the existing exposed surfaces of steel tubular pole of9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of aluminium paint marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for cement Painting of PCCpole 9.0/11.0 metre long, by applying one coat of cement colour after scraping / brushing and cleaning the rust on pole and street light bracket to painted with one coat of Aluminium paint. Cement colourwill be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from groundlevel will be painted by alternate layer of black and white enameled paint (30 Cms Each)Pole Nos shall be written on pole withblack paint in yellow circle of 150mm dia, complete, all as specified and directed. |