Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | (B/R PORTION)Demolition of Brick work / stone masonry built in cement mortar and removing the debris from MD land complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 4 | Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 5 | M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in1:4 cement mortar complete all as specified and directed. |
| 6 | M &L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified. |
| 7 | M&L RCC (nominal mix) type B1 1:2:4 (20 mm graded stone aggregate) using cills, steps, plinth courses, string course, coping and other similar bands etc complete all as specified. |
| 8 | M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1: 6finished fair & even & smooth without using extra cement, all as specified and directed. |
| 9 | M&L rendering 10 mm thick on fair faces of brick work/ concrete on ceiling surfaces in CM 1.3, finished fair & even & smooth without using extra cement complete all as specified and directed. |
| 10 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly . ) |
| 11 | Supply only integral water proofing compound all as specified and as directed. |
| 12 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. all as specified. |
| 13 | M&L 1.00 mm thick Plain, black, mild steel sheeting, in wall cladding, steel gates,in ridges, hips, valley gutters, drip and straight flashings and similar work cut to size, holes punch headed screws clout nails or rivets and fixed to woodor steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angle etc are required complete all as specified and directed. |
| 14 | Material and labour for providing Plain Cement Concrete(1:5:10) type E2 using 40mm graded aggregate as in sub base of floor all as specified and directed |
| 15 | M&L for Vitrified Ceramic tiles 8 to10 mm thick light shade (of square shape) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer or mortar 15 mm thick for laying floor finishes in CM 1:4 all as specifed and directed. |
| 16 | All as per item no 15 but using as skirting/dado including screed bed10 mm thick for wall tiling etc. in CM 1:3. |
| 17 | M&L non skid ceramic coloured digital tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles, including screed bed or bedding layer or mortar 15 mm thick for laying floor finishes in CM 1:4 all as specified and directed. |
| 18 | M&L for Glazed ceramic tiles in vertical surface 450X 300X 7/600x 300x 7mm thick as on vertical surfaces such as wall, dado, skirting etcset and jointed in neat cement slurry and pointed in colour cement to match including screed bed10 mm thick for wall tiling etc. in CM 1:3. complete all as specified. |
| 19 | Dismantling of 100mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and directed. |
| 20 | Dismantling of 150mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and directed. |
| 21 | S&F 100 mm bore cast iron (sand cast) soil and wastein any length with or without ears, with cement joints, fixed to walls complete all as specified. |
| 22 | S&F 150 mm bore cast iron (sand cast) soil and wastein any length with or without ears, with cement joints, fixed to walls complete all as specified and directed. |
| 23 | S&F 100 mm bore cast iron (sand cast) soil and waste in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 24 | S&F 100 mm dia Cl branch pieces complete all as specified and directed. |
| 25 | S&F 100 mm dia Cl bend complete all as specified and directed. |
| 26 | S&F 100 mm dia Cl branch pieces with ovel access door complete all as specified. |
| 27 | S&F 100 mm dia Cl bend with ovel access door complete all as specified. |
| 28 | S&F 100 mm dia Cl sanitary connection socket to fit WC outlet complete all as specified. |
| 29 | S&F for cast iron floor trap/nahani trap with grating including jointing to waste pipes in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate, 100mm dia outlet complete all as specified. |
| 30 | S&F 150 mm bore Cl (sand cast) bend any radius, diminishing pieces or tapers complete all as specified. |
| 31 | S&F 150 mm dia Cl (sand cast) branch, with or without ears, complete all as specified. |
| 32 | S&F stack clamps out of 50 mm dia by 5 mm flat iron and 16 mm dia round iron stay. including bolts and nuts and securing ends of stays to wall or roof of 100 mm dia of pipes complete all as specified and directed. |
| 33 | All as per item No 32 but 150 mm dia of pipes. |
| 34 | Taking up or down 15 mm bore steel tubing and including cleaning for refixing or removal to store complete all as directed. |
| 35 | Taking up or down 20 mm bore steel tubing and including cleaning for refixing or removal to store complete all as directed. |
| 36 | Taking up or down 25 mm bore steel tubing and including cleaning for refixing or removal to store complete all as directed. |
| 37 | S&F steel tubing water tubing medium grade, galvanised with all fittings of 15 mm bore and fixed to wall and ceiling or laid in floors complete all as specified and directed. |
| 38 | All as peritem no 37 above but fixing only. |
| 39 | S&F steel tubing water tubing medium grade, galvanised with all fittings of 20 mm bore and fixed to wall and ceiling or laid in floors complete all as specified and directed. |
| 40 | all as item no 39 above but fixing only. |
| 41 | S&F steel tubing water tubing medium grade, galvanised with all fittings of 25 mm bore and fixed to wall and ceiling or laid in floors complete all as specified and directed. |
| 42 | All as per item no41 above but fixing only. |
| 43 | S&F in repairs 15 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/20mm - 210gms/25mm-455gms/40mm - 690 gms) complete all as specified and directed. |
| 44 | S&F in repair vitreous china wash down water closet pedestal pan white excluding flushing cistern and flush pipes complete make Cera/Parryware (Slimline)/Hindware all as specified and as directed. |
| 45 | S&F in repairfor plastic water closet seat cover colour/ white, closed pattern with flat bottom and MS CPor aluminium hinging device complete all as specified and directed. |
| 46 | S&F in repair vitreous china wash hand basin white size 550x400 mm including bracket but excluding taps, waste pipes, chain and plug etc complete all as specified. |
| 47 | S&F in repairs PVC flushing cistern push button / handle type of 10 Itr capacity coloured complete with all fitting fixed to with WC including PVC flush pipes, brackets etc complete all as specified and directed. |
| 48 | S&F in repairs vitreous china urinal, full stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including PTMT urinal spreader, coupling, 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 49 | S&F PVC connection 450mm long of PTMT 15 mm bore ocomplete all as specified and directed. |
| 50 | S&F looking mirror 600 x 450mm of selected quality glass mounted on 6mm commerical ply or AC building board with aluminium frame around and fixed to wooden plugs with CP brass screws all as directed. |
| 51 | S&F looking mirror with size n exc 0.5 of selected quality glass mounted on 6mm commerical ply or desired pattern andfixed as specified and directed. |
| 52 | S&F looking mirror with size exc 0.5 and n exc 2 sqm of selected quality glass mounted on 6mm commerical ply or desired pattern andfixed as specified and directed. |
| 53 | S&F in repair chromium plated fancy type Soap dish holder complete all as specified and directed.Make:Cat No ACN-1131N of make Jaguar or equivalent make specified in tender. |
| 54 | S&F in repair chromium plated flap toilet paper holdercomplete all as specified and directed. Make:Cat No. CPA-16 of Make Prayag or equivalent make specified in tender. |
| 55 | S&F in repair 15mm bore angle valves, fancy type chromium plated with long shank and cup (Concealed type), complete all as specified and directed |
| 56 | S&F in repair PVC waste pipe 32 mm dia, 800-900 mm length complete all as specified and directed.Make: Cat no PTA-62of Make- Prayag or equivalent make specified in tender. |
| 57 | S&F in Repair chromium plated ABS body health faucet with 1 mtr tube and hook complete all as specified and directed.Make: Cat No CPHF-2 of Make Prayagor equivalent make specified in tender. |
| 58 | S&F in repair Brass chromium plated Grating of Size 102 mm dia with waste hole complete all as specified and directed. Make:Cat no PFT-24 of Make Prayag oor equivalent make specified in tender. |
| 59 | S&F in repair Brass chromium plated Grating of Size 102 mm dia complete all as specified and directed. Make: Cat no PFT-23 of Make Prayag or equivalent make specified in tender. |
| 60 | S&F in repair chromium plated 15 mm bore two way bib cock all as directed. (MAKE : JAGUAR, Cat no. LYR-38041/ PARRYWARE or equivalent make specified in tender. |
| 61 | S&F floor Mounted coupled closet white(Cat no C0232/86 Closet (P-190)), Regular seat cover (E8299 Regular), Cistern set including dual flush fittngs complete all as specified and directed. (Cat no C0765) of Make Parryware or equivalent make specified in tender. |
| 62 | S&F Pillar Cock Auto Closing System with 65mm Extension Body of Brasscomplete all as specified and directed.(MAKE : JAGUAR, Cat no. RS-031L65/ or equivalent make specified in tender. |
| 63 | S&F in repair Brass pillar taps fancy type chromium plated swan neck complete all as specified and directed |
| 64 | S&F in repair self closers pillar taps fancy type chromium plated brass complete all as specified and directed |
| 65 | S&F in repair Bib taps with aerator fancy type chromium plated Brasscomplete all as specified and directed.Cat No G4880A1 of Make Parryware or equivalent make specified in tender. |
| 66 | S&F brass chromium plated tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified |
| 67 | S&F towel ring fancy type chromium plated complete all as specified and directed Cat No T-6904A1 of Make Parryware or equivalent make specified in tender. |
| 68 | S&F in repair 15mm bore Urinal Valve Auto Closing System with Built-in Control Cock & Wall Flange. fancy type chromium plated complete all as specified and directed. Cat No PRS-077 of Make Jaquaror equivalent make specified in tender. |
| 69 | S&F in repair chromium plated brass bottle trap 12 inch (Project) with complete arrangement etc of Cat No CPBT-2 of Make Prayag/or equivalent make specified in tender. |
| 70 | M & L for preparation of new surfaces of walls and applying two coat of Oil Bound Distemper over a coat of alkali resistant primer and 1 mm thick wall care putty , all as specified and directed |
| 71 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 72 | Ditto as item no 71 but on steel surfaces. |
| 73 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed. |
| 74 | M&L for preparation of old decorated plastered surfaces or un-plastered surfaces of wall and applying coat of white wash complete. all as specified and directed. |
| 75 | Ditto as per item no 74 above but ceiling. |
| 76 | M&L for preparation of old decorated plastered surfaces or un-plastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed |
| 77 | Ditto as per item No 76 above but on ceiling |
| 78 | M&L for preparation of old painted steel & iron surfaces of any description over 10 cm width or girth and applying one coat of aluminium paint complete all as specified and as directed. |
| 79 | M&L for preparation of new steel and iron surfaces of any description, n. exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 80 | M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 81 | M&L for cleaning of roofs by getting out growing vegetations / grass & brooming down with removing it out of MD land premises of including repainng to damaged surface of roof by applying two coats of tartaric acid over two coats of CM (1:3) with mixed with 3% WPC & sealed with 85/25 hot blown grade bitumen complete in patch not exceeding 2.0 Sqm each including necessary form work, complete all as directed by Engineer in Charge. |
| 82 | M&L for repairing of damaged portion of mouth at tarrace / roof surface of rain water pipe by cleaning and repairing to mouth of RWP by using CM (1:3) with mix with liquid WPC & sealed with 85/25 hot blown grade bitumen complete to make joint of rain water pipe and roof suface fully leak proof complete all as directed by Engineer in Charge. |
| 83 | Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area not exceeding 1.5 sqm each and removing from the site complete all as specified and directed. |
| 84 | Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 sqm each and not exceeding 4 sqm removing from the site complete all as specified and directed. |
| 85 | Taking down shutters of any description area not exceeding 1 sqm each removing from the site complete all as specified and directed. |
| 86 | Taking down shutters of any description area exceeding 1.00 sqm and not exceeding 2.00 Sqm each and removing from the site complete all as specified and directed. |
| 87 | Taking down shutters of any description area exceeding 2.00 sqm each removing from the site complete all as specified and directed. |
| 88 | M&L for Second class hardwood plain solid straight chowkats and frames wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified. |
| 89 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 90 | Supply and fixing 30mm thick flush shutters, solid core construction, with block board core and plywood face panels. commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match. complete all as specified and directed |
| 91 | Supply and fixing 30mm thick flush shutters, solid core construction, with block board core and plywood face panels. commercial type on both sides and both face is covered with decorative face veneer with lipping/frame to match. complete all as specified and directed. |
| 92 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 93 | S&F Butt Hinges medium weight cold rolled stainless steel 100mm long complete all as specified |
| 94 | S&F Butt Hinges medium weight cold rolled stainless steel 75mm long complete all as specified |
| 95 | S&F aluminum anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed |
| 96 | S&F aluminum anodised barrel tower bolts of extruded section 200mm long complete all as specified and as directed |
| 97 | S&F Aluminum anodised bow handle fabricated type extruded section of 150mm long complete all as directed |
| 98 | S&F Aluminum anodised bow handle fabricated type extruded section of 125mm long complete all as directed |
| 99 | S&F Aluminum aodised sliding door bolts of 250mm long with hasp and staple(bolt type) and fixing clips of sheets cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 100 | S&F Aluminum aodised sliding door bolts of 300mm long with hasp and staple(bolt type) and fixing clips of sheets cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 101 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all as specified |
| 102 | Supply and fixing in repairs 150mm extruded brass handles, cast type, polished bright complete all as specified and as directed. |
| 103 | S&F in repair powder coated Z type aluminum handle/american handle/round handle suitable for aluminum windows/door. all as directed. |
| 104 | Taking down aluminum frame with shutters of any description nexc 1.50 sqm each. complete all as specified. |
| 105 | Taking down aluminum frame with shutters of any description exc 1.50 but n.exc 2.0 sqm each, complete all as specified. |
| 106 | Taking down aluminum shutters of any description exc 1.0 but n.exc 2.0 sqm each. complete all as specified. |
| 107 | S&F anodised aluminum frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 108 | S&F anodised aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws, etc. complete all as specified. |
| 109 | S&F anodised aluminium window and ventilator shutters, side hung type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150mm long (01 No) hinges type B-21 100 mm long (2 No) suitable handles etc. complete all as specified. |
| 110 | Supply and fixing in repairs aluminium (die cast) body door closer hydraulically regulated designation No 3. universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed |
| 111 | Supply and fixed in repairs double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheed foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed |
| 112 | S&F in repair 150 mm over all length of cover plate of floor door stopper of Brass or Polished Iron body and tongue, anodised with hard drawn steel spring fixed in floor. |
| 113 | M&L for repair to steel window/door/gate including necessary welding, riveting, Easing, drilling, greasing Taking down replacement of unserviceable hinging device, handles, making them in serviceable condition and re-fixing in same opening complete all as specified and directed. |
| 114 | M&L for sheet glass 4.80mm thick ordinary quality obscured or frosted on one side and glazing with oil putty in square exec 0.5 Sqm in each pane complete all as specified and as directed. |
| 115 | M&L solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, all as specified and directed. |
| 116 | M&L 0.9 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instructions complete all as specified |
| 117 | Supply and fixing Mortice lock vertical type (chrome including handles and connected items) 100mm, 6 levers as in repair complete all as specified and as directed. (Make Godrej Model No-8194 or equivalent model in other approved makes) |
| 118 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, wooden flooring of any thickness including cover fillets complete all as specified |
| 119 | M&L anodised aluminium snap grid with powder coated frame work for false ceiling of size 605x605 mm including 4 mm dia Gl (upto 1200mm length) hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of Gl flat 40x3 mm size 60 mm long and expansion hold fasteners 12 5mm dia 40 mm long complete all as specified |
| 120 | All as per item No 119 but fixing only. |
| 121 | M&L 4mm non asbestos fibre cement building boards flat, fixed or laid/inserted to timber/Gl/aluminium frame work with screws complete and applying two coats of Oil bound distemper over a coat of primer complete all as specifed |
| 122 | S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed |
| 123 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed |
| 124 | Supply and fixing PVC decorative beading of 5mm thick moulded /designed for PVC wall panneling inclusive of fixing complete all as specified and directed. |
| 125 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., forming bottom surfaces to required slope/gradient where pipe are laid and getting out in any type of soil complete all as specified and directed. |
| 126 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed. |
| 127 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 128 | Taking up / down GI of size 50 mm bore, water tubing and connection from trenches/ walls / floors (of any location) for replacement / re-use in old / new location as directed by the Engr-in-Charge. (Note: Necessary earthwork, if any , will be measured and paid separately under relevant items) |
| 129 | All as per Item No.128 above but of size 40 mm bore |
| 130 | All as per Item No.128 above but of size 25 mm bore |
| 131 | All as per Item No.128 above but of size 20 mm bore |
| 132 | All as per Item No.128 above but of size 15 mm bore |
| 133 | S&F, in repair 15 mm bore steel water tubing, medium grade, ISI marked, galvanized, including all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., laid in trenches or fixed to walls and ceilings or concealed in walls, ducts/ceilingsor laid in floors complete all as specified and directed. |
| 134 | All as per item No 133 above but 20mm bore of pipe. |
| 135 | All as per item No 133 above but 25mm bore of pipe. |
| 136 | All as per item No 133 above but 40mm bore of pipe. |
| 137 | All as per item No 133 above but 50mm bore of pipe. |
| 138 | S&F in repairs, 20mm dia Gun metal, globe or gate valves with iron wheel head, ISI marked screwed both ends for iron/GI pipe and fixed complete all as specified and as directed. |
| 139 | All as per item No 138 above but 25mm dia globe or gate valve. |
| 140 | All as per item No 138 above but 40mm dia globe or gate valve. |
| 141 | All as per item No 138 above but 50mm dia globe or gate valve. |
| 142 | Construction of valve chamber of size750x750x750 mm internal size suitable for housing sluice valve / gate valve etc with PCC 1:4:8 type D2 for foundation 15mm thick with an offset of 5 cm on all sides, brick work in CM 1:4 230mm thickrenderingin CM 1:4, 15mm thick, 5 cm thick & 230mm wide PCC 1:2:4 type B1 coping over brick work all around including provision of MS angle iron frame 25 x 25 x 3mm embedded in concrete with suitable hinges3mm thick MS sheet cover and locking arrangements including two coats of synthetic enamel paint over a coat of red oxide metal primer on exposed steel surfaces including demolition of existing damaged valve chamber and necessary excavation & earth work etc all as specified and directed. |
| 143 | Taking up / down unserviceable / rust valve pit cover and frame / support or platform etc of any size/thickness and supply, fabrication and fixing of framed brackets, made of mild steel plate/ flat / angle iron (of required size), cut to shape and size, as in valve pit cover/ frame / support or platform including necessarybending / welding etc as required and applying two coats of black bituminous paint over a coat of red oxide zinc chrome primer complete all as directed by the Engr-in-Charge. |
| 144 | Cutting of road/hard standing not exc 30cm in wich and not exc 60cm in depth for removal/laying of water tubing including returning filling and making good the disturbed surfaces using PCC 1:2:4 type B1 using 20mm graded stone aggregate on top 100mm layer and fair fininshing the surface without using any extra cement all as specified and directed. |
| 145 | Taking down carefullyexisting aluminium/copper point wiring on battenor in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making goodthe disturbedsurfaces of walls, Floors, ceilings etc to match with existingall as specified and directed. |
| 146 | M & L for concealed type point wiring with 1.50 sqmm (noninal area) FRLSH insulated and unsheathed muld stranded copper conductor cable 1100 Volts grade,single core,laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/celling including muld steel terminal boxes 1.25 mm thick conforming to IS - 5133(Part -I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked ) for mounting switches/ regulator / bell push etc including 1.50 Sqmm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade,single core, earth continuity conductor connected to common earth dolly, for one light point / bell point/ ceiling fan / exhaust fan point cotrolled by one way switch complete all as specified and directed. |
| 147 | All as per item No 146 above but one light/fan point controlled by one switch |
| 148 | S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed. |
| 149 | S & F Modular Blank plate, 1 module complete all as specified and directed. |
| 150 | S & F Modular type White cover plate with frame 3 module complete all as specified and directed. |
| 151 | S & F Modular type Metal Flush box 3 module complete all as specified and directed. |
| 152 | S&F Ceiling rosethree terminals polycarbonate , isolated body completeall as specified and directed. |
| 153 | Supply and fixingin reapirLED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 154 | S & F LED decorative Wall lightsfitting 4 W x 2, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cableE-14 LED 4w X2 complete all as specifide and directed. Make: PHILIPS 32033/11/66 Aquafit wall light(Chrome and Metal,12W)-DCor equivalent make specified in tender . |
| 155 | S & Fceiling fans in repair complete with all accessories 230 volt single phase 1200mm sweep with down rod any size , canopy, fan blades and accessories, BEE 5 Star Rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed. |
| 156 | Supply & fixing in repair wall mountedfans 230 volts singlephaseoscillating 450 mm sweep including all Fixing accessories for fixing at Wall complete all asspecified and directed by Engr-in-Charge. |
| 157 | Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation. |
| 158 | M & L for sub main wiringwith 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through & including PVC conduit of suitable size in Surface/concealed all as directed. |
| 159 | Taking down of Old MCB DB any type any size including MCBs etccomplete all as specified and directed. |
| 160 | S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 amps rated bus bar complete all as specified and directed. |
| 161 | S & F MCB \"C\" curve single pole neutral , 32 Amps with breaking capacity 10kA,complete all as specified and directed.Make: Cat no.408617 of Legrand or equivalent make specified in tender . |
| 162 | S & F MCB \"C\" series single pole 5 to 32 Amps, breaking capacity 10KA. Cat No. 408587, Make: Legrand or equivalent make specified in tender . |
| 163 | M&L for dismantling the split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton in various location, shifting to MES Yard for repair/replacement of unserviceable spares and servicing, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and painting the outer cabinet by enamel paint and sticking a sticker mentioning “the MES Number and reassembling, testing, checking and shifted to existing location/new location as directed, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare partsIncluding replacing of starting capacitor, running capacitor, over load protection relay , compressor, condensing coilmeasured & paid separately).Make: VOLTAS/HITHACHI/BLUE STAR/SUMSUNG/LG |
| 164 | Supply & Fix new compressor seal unit of suitable capacity/model in the unit properly for 1.5 TR split type AC all as specified and directed. |
| 165 | Supply & Fix new compressor seal unit of suitable capacity/model in the unit properly for 2 TR split type AC all as specified and directed |
| 166 | Supply & charge ofrefrigerant gasR-22/R-140a/R-32 complete all as specified and directed. |
| 167 | Supply & charge ofrefrigerant gas 134A complete all as specified and directed. |
| 168 | M&L for replacement of capillary tube and stainer for split AC of 1.5 ton/2.0 ton capacity complete all as specified and directed. |
| 169 | Supply only copper condensing coil unit for split type AC 1.5 / 2.0 ton capacities all as specified and directed by Engr-in-charge. |
| 170 | S&F for coppercooling coil unit for split type AC of any type all as directed by Engr-in-charge including taking out old unserviceable cooling coil unit complete all as specified and directed. |
| 171 | S&F for capacitor for blower motor suitable for splittype AC 1.5 ton capacity including taking out old unserviceable capacitor complete all as specified and directed. |
| 172 | S&F for copper pipe 5/8\" / 1/2\" / 3/8\" / 1/4\" dia (as per existing one) for connection indoor and out door unit complete all as specified and directed. |
| 173 | S&F for PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete all as specified and directed. |
| 174 | S&F for PVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete all as specified and directed. |
| 175 | S&F for swinging motor of split type AC 1.5/2 TR with louvers as pr existing out old unserviceable swinging motor with louvers complete all as specified and directed. |
| 176 | S&F for fan blade for blower motor suitable for split AC 1.5 ton / 2.0 ton capacity including taking out old unserviceable blade complete all as specified and directed. |
| 177 | S&F for fan blade for outdoor unit of split type AC of any capacity including taking down old one all as directed . |
| 178 | S&F for LCD / LED display unit for split type AC 1.5 / 2.0 ton capacity including taking out old unserviceable unit complete all as specified and directed. |
| 179 | S&F for replacement of PVC air filter for AC split type 1.5 / 2.0 ton capacity complete all as specified and directed. |
| 180 | S&F for PCB for control unit for split type AC 1.5 / 2.0 ton capacity as per existing and same complete all as specified and directed. |
| 181 | Supply only remotecontrol unit for split type AC 1.5 / 2.0 ton capacity as per existing and same complete all as specified and directed. |
| 182 | Dismantling and taking down old unsv street lights of any wattage or size complete all as specified and directed. |
| 183 | S&F insulated unsheathed PVC ,FRLS,three core stranded copper conductor 1.5 sqmm x 2 +1.5 sqmm for earth contuinity conductor drawn through steel conduit pipe of medium gradefixed to pole with fixing arrangement, working voltage 1100 volts grade, 50 Hzconforming to IS-694 from junction box to street light fitting or for OH connections complete all as specified and directed. |
| 184 | S&F in replacement of60 W LED street light fitting with lens optics on LEDs, IP 66 protected luminaire fixture made from pressure die cast aluminum housing & heat resistance toughned glass cover with one number of 60 W driver, having wide operating voltage range &lumen efficacy>105 lm/w.Surge protection upto 10 KV PF>0.95 temp 5700 K to 6500 K IP 66, surge protection 10 KV as directed by Engineer-in-charge including taking out old U/S street light fitting of any type/size. Note: Reducer including cuttig welding etcif required at site for installing LED fiitings shall be deemed to be included in quoted rates. |
| 185 | S&Fthermoplastic, polystyrene unbreakable junction box size 250 x 200 x 100 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamp & nut, bolts, washers and including resin type terminal block heavy duty suitable for ring lugs with phase seperators between R, Y, B, Nterminals and one MCB SP 6 amp 10 KA, all duly mounted on din cannel, cable glands for cable entry incl GI double clamp made out of 25x4 mm GI stripcomplete all as specified and directed. |
| 186 | Supply,lay,connect and commission LT underground cable XLPE of size10 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc complete all as specified and directed.. |
| 187 | Supply,lay,connect and commission LT underground cable XLPE of size 16 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc complete all as specified and directed. |
| 188 | Supply,lay,connect and commission LT underground cable XLPE of size 25 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc complete all as specified and directed. |
| 189 | Supply,lay,connect and commission LT underground cable XLPE of size 50 sqmm 3.5 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc. |
| 190 | Excavtion in trenches n.exc 1.5 meter wide and n. exc 1.5 meter in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil. |
| 191 | Allasperitem No 189 above but hard surfacessuch as inroadcutting/ hard standingetcincludingmakinggooddisturbedsurfaces to matchwithoriginal completeallasdirected. |
| 192 | Supply and laying new dry riversand laidintrenches 8 cm below the cable and 15cm above the cable and punned to 18 cmascablecushioningandcoveringall asdirected. |
| 193 | Supply and layingin replacement of brickwell burntlocallyavailablesubclass \"B\" laid over sand cushioningfor cableprotectionintrencheswidthofbrickperpendicullar to the length of cableincluding taking up of old UNSV bricks complete all as specified and directed by Engr-in-Charge. |
| 194 | M&L for Galvanised Steel Tubing Pipe 40 mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. |
| 195 | Supply and fixing MCCB enclosure pole /wall mounteed outdoor type including 100 Ams, 4P, 16KA, MCCB and fixing arrangement complete all as specified and as directed. |
| 196 | Supply and LayingXLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable , laid in trench or fixed to wall / passing through pipe/ pole complete of size 16 Sqmm 2 Core complete all as specified and directed. |
| 197 | Supply and fixing in sheet metal enclosure 2 way without bus bar, Single Door, 240 Volt, 50 Hz, with Isolator SPN 40 Amps fixed on Gate Post including making good existing disturbed surface with cement mortar as required at site complete all as specified and directed. |
| 198 | Supply and fixing of Decorative Post Top light fitting, 40 Watt LED type, 230 Volts, 50 Hz, with IP 65 protection, resistant to impact and corrosion, glare free and better uniformity, fixing on gate post with GI pipe light grade fixed on gate post with cement mortar as required at site and making good distured surface complete all as specified and directed. |
| 199 | Supply and fixing of Decorative Post Top light fitting, 20 Watt LED type, 230 Volts, 50 Hz, with IP 65 protection, resistant to impact and corrosion, glare free and better uniformity, fixing on gate post with GI pipe light grade fixed on gate post with cement mortar as required at site and making good distured surface complete all as specified and directed. |
| 200 | S&F PVC insulated unarmoured & PVC sheathed copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from Sheet metal enclosure to light fittings including with suitable size copper lugs complete all as specified and directed. |
| 201 | S & F in repair LED wall mounted spot focusing light fitting 4 watt, colour temperature 2700K, mounted on wall / ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed. Cat No. 56240/31, Make: Philips or equivalent make specified in tender. |
| 202 | S&F in repair threaded type E 27 Cool day LED Bulb and warm light with color temperature 6500 K suitable for 9 W metal and synthetic material lumen complete all as specified and directed. |
| 203 | S&F in repair threaded type E 27 Warm LED Bulbwith color temperature 6500 K suitable for 5 W metal and synthetic material lumencomplete all as specified and directeded. |
| 204 | S&F in repair threaded type E 14 Cool day LED Bulb and warm light with color temperature 3000 K suitable for 9 W metal and synthetic material lumencomplete all as specified and directed. |
| 205 | S&F in repair threaded type E 14 Warm LED Bulbwith color temperature 3000 K suitable for 5 W metal and synthetic material lumenMake: Philips or equivalent of havells complete all as directed. |
| 206 | Supply and fixing of Hot Dipped Galvanised(Z+) Wiremesh cable tray outdoor type with wire dia from 3.9 mm to 5.9 mm of size 3000mm x 105mm x 300mm, including supports. It shall be manufactured with a longitudinal \"T\" welded safety edge. Trays shall be constructed with 50 mm / 100 mm mesh configuration. Accessories for coupling and making \"T\"s and bends CE25/CE30 screw based system combination must be used and mounting accessories are required of same finish of same manufacturer as per the site requirement (celing/wall mounted). Trays should comply standard EN ISO14 61: at least 550 hrs. of SST. The deflection of cable tray must be within 1/200-th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire cable trays must be designed with an optimum span of 1.5 mtr., taking into account the maximum load carring capacity as authorised by the manufacturer. Assembly with fire ressitant properties must have an E30/E90 certificate. The loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537. No hot work for trays is allowed at site. MAKE: LEGRAND (CABLOFIL)/ COPE/ LEVITON/ PANDUIT |
| 207 | M&L for ERDN Coupler for jointing two cable trays with fixing arrangements KI TASTER complete all as specified and directed.Note : KI Taster will be measured and paid separetely. |
| 208 | M&L of KI Taster for jointing of two cable tray with the fixing arrangements complete all as specified and directed. |
| 209 | M&L of mounting support RCSN 3000 for cable tray compete all as specified and directed. |
| 210 | M&L of cable tray cover of 2 meter length joints with fixing clip complete all as specified and directed.Note : Clip will be measured and paid separetely. |
| 211 | M&L of Clip for joint of cable tray cover complete all as specified and directed. |
| 212 | Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :-(Note :-Necessary earth work to be measured and paid separately. |
| 213 | 120 Sqmm, 3.5 Core |
| 214 | S&F in repairs of MCCB 4 Pole, 415 V, Adjustable type 400 Amps with breaking capacity 36 KA with all accessories incl taking down existing MCCB complete all as specified and directed. |
| 215 | Supply and fix (in replacement) MCCB, 4 pole, 36 KA, with thermal maganetic release range, 315 - 320 amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No - CM98403OOQOOG / LEGRAND, Cat No: 4220 06 / HAVELLS, Cat No: IHBA9EMF0350 / C&S, Cat No: CSE3M400ATM4P_320 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) ) |
| 216 | S&F in repairs of MCCB 4 Pole, 415 V,Adjustable type 250 Amps with breaking capacity 36 KA with all accessories incl taking down existing MCCB complete all as specified and directed |
| 217 | S&F in repairs of MCCB 4 Pole, 415 V, Adjustable type 160 Amps with breaking capacity 36 KA with all accessories incl taking down existing MCCB complete all as specified and directed |
| 218 | Supply and fix (in replacement) MCCB, 4 pole, 25 KA, with thermal maganetic release range,100 amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed Make- L&T type DN0-100C Cat No - CM91712OOKOOG, or equivalent make specified in tender. |
| 219 | Supply and fix (in replacement) MCCB, 4 pole, 25 KA, with thermal maganetic release range,63 amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed Make- L&T type DN0-100C Cat No - CM91712OOHOOG, Havells Cat No IHA13EBF0063 or equivalent make specified in tender. |
| 220 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail