| 1 | S&F In repair/replacement of Microprocessor based control panel suitable for Blue star Chiller/Acplant,Complete with digital display for fault indication ,CHW flow monitoring compressor control,Manual ON/OFF & reset facility,safety interlocks,indication lamps and all acceessories,fully wired,sitable for Blue star chiller plant model No:XWC3S-039AR2 complete all as specified and directed |
| 2 | S&F In repair/replacement of installation,testing and commissioning of Microprocessor based control panel for voltas model No: 5H 60 Air conditioning chiller plant complete with all necessary internal components, with digital display for fault indication ,CHW flow monitoring compressor control,Manual ON/OFF & reset facility,safety interlocks,indication lamps and all acceessories,fully wired completeall as specified and directed |
| 3 | S&F In repair/replacement of 12/13 mm thick nitrile rubber insulation on hot and cold pipe of size 100/150mm dia and fitting like valve,flanges, and union etc includingremoving pit cover of any size and rearrange after installation of nitrile rubber to its origianal posioncomplete all as specified and directed |
| 4 | S&F In repair/replacement ofFRP soild cover for drain having size up to 1500mm X 1220mm X 38mm (Aprrox) or suitable for site having load bearing capacity up to 2 ton complete all as specified and directed. |
| 5 | S&F In repair/replacement of5000 ltr capacity of rotational moulded polyethylene water storage tank 2 layered construction ISImarked of make as specified cylindrical vertical with closed top hoisted and fixing in position including 20mm GI pipe medieum grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacityexceeding 5000 tr complete all as directed |
| 6 | S&F In repair/replacement of CPVC pipe of size 15 mm bore,ISI Marked complete all as specified and directed |
| 7 | S&F In repair/replacement of CPVC pipe of size 40mm bore,ISI Marked complete all as specified and directed |
| 8 | Supply, Fixing, connecting and testing in repair/replacement of automatic voltage stabilizer, wall mounted type, single phase, naturally air cooled, indoor type designed for input variation between 130 to 300 Volt and out put voltage stabilised at 230 Volts with accuracy of (+) 2.5% and capacity 1 KVA complete all as specified. |
| 9 | S&F In repair/replacement of pressure gauge for suction/discharge for refrigerant R-22/R-407C. Make :SCIENTIFIC Range : 30 to 150 and 0-300 lb/sqm inch or equivalent as approved by GE. |
| 10 | S&F In repair/replacement of primary air filter sliding type viscous upto 10 micron of Existing size and shape complete all as specified and directed. Make : MOOSA/UCCO |
| 11 | S&F In repair/replacement of submersible flat cable 6.0 SqmmX 3 core,1100 volt ,ISI Markcomplete all as specified and directed. |
| 12 | S&F In repair/replacement of Butterfly valves PN 1.6 flanged type heavy dutyof size 100 mm bore including necessary accessories to fix the same in existing hot as well as in chilled water line complete all as specified and directed. Make : Audco/Advance/Castle or any equivalent ISI marked. |
| 13 | S&F In repair/replacement of PVC Insulated, unsheathed multi stranded copper conductor cable, heavy duty, 1100 Volts gradesingle core of RYB colour 16 Sqmm in replacement for connection from LT panel board to motor starters and from starters to electric motors including necessry cable end termination with copper lugs of suitable size all as directed, confirmong to IS:694drawn through concealledheavy gradePVC conduites of not less than 32 mm nominal dia with necessary fittings such as bends, sockets etc. laid under the floor or fixed to the walls with suitable clamps or saddles including taking down of existing cable all as specified and directed |
| 14 | S&F In repair/replacement of Cast Iron strainer of flange type of latest design of size 150 mm inclremovable stainlesssteel screen,drain plug and all accessories ,istalled in existing pipe line complete all as specified and directed by Engr-in-Charge. |
| 15 | S&F and Dismantling In repair/replacement of the old U/S out door unit of split type AC of cap 1.5 Ton and fixing of the new out door unit complete with condensor coil, cooling coil made of copper coil , blower motor with PVC fan blade ,Wiring Kit,two pole contactor,running and starting capaciter of 40 to 45 MFD capacity including provision of fixingexisting compressor & charging refrigerant gasR22 of required quantity including testing on full load all as specified & directed. Note:Charging of refrigerant gas ofrequired quantity to be measured and paid separately |
| 16 | S&F and Dismantling In repair/replacement of the old U/S in door unit of split type AC of cap 1.5 Ton and fixing of the new in door unit complete with cooling coil made of copper, blower motor,swing motor,electonic PCB,Display unit,temprature sensor,box type relay complete with PVC drum & electronic circuits including testing all as specified & directed. |
| 17 | S&F In repair/replacement of new sealed compressor of approved make and capacity 230 VAC for 1.5 ton split type AC Complete all as specified and directed |
| 18 | Supply and fix in repair/replacement of fan motor with steel blade having copper wounded with blade suitable for the 6000 CFM sizesdesert cooler SP 230 Volt 50 Hz including commissioning and testing complete all as specified and directed |
| 19 | S&F and Dismantling in repair/replacement of the old U/S desert cooler and supply & fixing in replacementnew cabinet fabricated with 24 gauge GI sheet consisting ofthree side panels ,front, top and tank ,GI wire net including vertical member ,of size not less than 85cm x 60cm x 52 Cm in size with double diversion grills and grill box suitable for not less then 15” sweep fan and making holes with fixing arrangement incl providing 4 way PVC distributor, PVC pipe 1.5 to 2 Mtr for water, wood wool pads , electrical wiring for fan & pump, controlled separately with 5 amp Piano type switch etc water tank and top cover painted with two coat black anti corrosion paingcomplete all as specified and directed. |
| 20 | S&F In repair/replacement of heavy duty air conditioner outdoor unit mounting bracket/stand suitable for 1.5/2.0TR split Type air conditioner as per sample complete all as specified and directed. |
| 21 | S&F In repair/replacement of new sealed compressor of approved make and capacity 230 VAC suitable for 286 ltr refrigiratorComplete all as specified and directed |
| 22 | S&F In repair/replacement of Auto defrost thermostat with knob /Bimetal thermostate with heater Assembly for any size of refrigerator. |
| 23 | Taking out old unserviceable relay unit and supply and fix new relay kit/PTC relayas per samplefor any capacity refrigerator and deepfreezer. |
| 24 | S&F In repair/replacement of Running capacitor 10/15/25 MFD for any capacity water cooler and refrigerator |
| 25 | S&F In repair/replacement of evaporatorfreezerassembly for single door refrigerator up to 286 Ltrcapacity of any make & capacity as specified and directed. |
| 26 | S&F In repair/replacement of electronic power supply control PCB for double door refrigerator of any make & capacity as specified and directed. |
| 27 | S&F In repair/replacement of evaporator fan motor for double door refrigerator of any make & capacity as specified and directed. |
| 28 | S&F In repair/replacement of old wornout/burnt wiring of refrigerator by using copper conductor wire PVC sheathed of suitable size and length complete all as directed by Eng-in-charge. |
| 29 | S&F in repair/Replacement for Design, supplying, installing, testing and commissioning LT indoor double door IP-54 type panel board, factory fabricated cubical type suitable for floor mounting and made out of CRCA sheet 2 mm thick suitable size of channel for base complete with necessary 75×40×6 mm angle iron foundation frame and fabricated cabinet for housing and mounting MCCBs, metering equipment and compartmentalised copper conductor and duly powder coated and panel board fixing on angle iron frame which is approved by the Engineer-in-Charge and comprising with the following duly CPRI Approved.NOTE: Mounted on channel MC-100 duly grounded to existing flooring.Outgoing MCCBs and accessories:(i) MCCB 4 Pole, 350 Amps, 415 Volts, 36 kA – 01 No.(100% Ics – 100% Icu) with connection terminals(Thermal setting adjustable type 70–100%)(ii) MCCB 4 Pole, 250 Amps, 415 Volts, 36 kA – 01 No.(100% Ics – 100% Icu) with connection terminals(Thermal setting adjustable type 70–100%)(iii) MCCB 4 Pole, 63 Amps, 415 Volts, 16 kA – 04 Nos.(100% Ics – 100% Icu) with connection terminals(iv) MCB SPN, 32 Amps – 01 No.(v) RYB indication LED type, 22.5 mm dia, 230 volts protected with MCB SP 2 Amp showing 3 phase supply – 3 Sets(vi) Ammeter 0 to 300 Amp, anal., 96×96 mm, auxiliary voltage 230 volts suitable size of CT with selector switch – 1 No.(vii) Digital volt meter of range 0–500 Volts, 96×96 mm, auxiliary voltage 230 volts with built-in selector switch – 1 No.(viii) Wiring with single core copper conductor cable FRLS grade / PVC insulated copper strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB – 1 Job. |
| 30 | S&F in repair/Replacementforearthing complete with GI earth plate electrode of size 60cmx60xcmx6mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below the normal ground level connected to GI earth strip 32x6mm size as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, protected by GI pipe medium grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm bore medium grade etc and testing on completion complete all as specified and directed. (Note :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50mm thick reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, funnel with watering pipe 20mm bore medium grade, GI protection pipe medium grade 32mm bore and wire meshand adequate quantity of charcole and salt complete.Note No 2 :- Rate of GI earth strip and GI protection pipe up to 7.5 m shallbe included in unit quotedrate of the this item |
| 31 | Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz doublepole 100 Amp all as specified and directed by EIC. |