| 1 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out out soft/loose soil all as spd and as diracted. |
| 2 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as spd and as diracted. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 4 | M&L for Plain Cement Concrete type C2 1:3:6 (using 40 mm graded crushed stone aggregate) in foundations,filling and mass concrete complete all as specified and as directed |
| 5 | Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed including demolition of brickwork. |
| 6 | Ditto as aboveitem No.7 but except bricks complete all as specified and directed including demolition of brickwork.Note :- Serviceable bricks obtained from dismantling shall be reused. |
| 7 | M&L for Brickwork with flyash bricks, straight or curved on plan to any radius inhalf brick thick walls, built in cement mortar 1:4complete all as specified and as directed including demolition of brickwork. |
| 8 | M&L for Plain Cement Concrete type B0 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping complete all as specified and as directed including demolition. |
| 9 | Rendering 15mm thick on fair faces of brick work or concrete surfaces Cement mortar 1:4 complete all as specified and as directed |
| 10 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand all as specified and as directed including demolition of cement concrete ureinforced. |
| 11 | S&F galavanized. 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and galvanized coating of steel wire shall confirm to the requirement as laid down for medium coated wire in IS 4826 and straining and fixing to any type of standard rails staining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc complete including dismanting of Barbed wire all as specified and as directed. |
| 12 | Fixing onlyold barbed wire with restraining & resecuring including making good staples etc all as specified as diracted dismanting of Barbed wire |
| 13 | M & L for preperation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide, primer exceeding 10cm in width or girth not otherwise described. |
| 14 | M&L for three coats of colour wash on newly plastered/unplastered /concrete surfaces of wall/fencing posts including preparations complete all as specified and as directed. |
| 15 | Dismantling of chain link fencing of any type any size all as specified and as directed. |
| 16 | Supply only 75x75 mm mesh size Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 17 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 18 | Fixingonly of old chain link fencing with restraiting & resecuring inlcluding making good staple all as specified as diracted. |
| 19 | S & F for MS work like posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work complete all as specified and as directed |
| 20 | M & L for preperation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide, primer not exceeding 10cm in width or girth not otherwise described. |
| 21 | M&L for Granite (of any type) 15-18 mm mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and olishing completeincluding dismantling floor, hearth or wall tiling. |
| 22 | Supply & fix Precast RCC fencing posts with (1:2:4 )concrete Type B1 (Using 20mm graded stone aggregate) sectional area exceeding 100 Sq Cm but not exceeding 250 Sq Cm complete all as specified and as directed. (Note: (i)The rate quoted shall be inclusive of form work. (ii) Reinforcement will be measured and paid separately including Dismantling wrought iron or mild steel work of any description. |
| 23 | M&L Mild steel TMT bars 8mm to 10mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality . |
| 24 | M&L for TMT bars 5mm to 8 mm dia ,cut to length bent to shape required in stirrups spacers and binders and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to Fe-410 S or Fe-410-O complete all as specified and directed. |
| 25 | All as per item No 29 above but 6mm dia round bars as in nibs complete all as specified and as directed. |
| 26 | S&F Mild steel screw bolts (machine made) die 5-10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. |
| 27 | M&L Exterior wall coloured tiles7 to 8mm thick (Square/rectangular) area of each tile exceedingn. exc. 0.16 Sqm in vertical surface for wall claddingset and jointed in neat cement slurry and pointed white or colour cement to match as specified as diracted including dismantling floor, hearth or wall tiling. |
| 28 | M&L for paver tiles 10 mm thick, set, jointed and pointed in neat cement slurry over in pavement/foothpath/floors over incl 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directedincluding dismantling floor, hearth or wall tiling. |
| 29 | M&Lfor 75 mm thickcement concrete 1:3:6type C-2 (using 40 mm graded stone aggregate) as in path /steps laid with and incl use and waste of form workand finishing the surface even and rough to receivethe topping layer ortiling complete . |
| 30 | M&L Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including dismantling of mild steel and related all as per specified and as directed. |