| 1 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as specified and directed. |
| 2 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) , complete all as specified and directed. |
| 3 | Dismantling of Stone sett paving laid dry and dry pointing of any description or thickness |
| 4 | M&L PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in benching, coping,kerbs etc |
| 5 | M&L for 100 mm thich PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed |
| 6 | M&LProviding and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand , complete all as specified and directed. |
| 7 | Material & labour for chequeredcement concrete tiles factory made pre polished glossy finished 30cmx30cmx20-25mm thick set, jointed and pointed in neat cement slurry in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified & directed. |
| 8 | M&L brick work with sub class \"B\" brick straight or curved on plan exc 6m means radius build in cement mortar 1:6complete all as specified and directed. |
| 9 | Description all as per ser item No 8, but except brickscomplete all as specified and directed. |
| 10 | Taking down cement plaster on wallof any description incl racking out joints hacking for key and scrubbing down with watercomplete all as specified and directed. |
| 11 | M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement )complete all as specified and directed. |
| 12 | M&L three coat ofcement paint on newly preparedsurfaces on wall , etc complete all as specified and directed. |
| 13 | M&L two coat ofcement paint on Complete removal of existing old surfaces on wall , etc complete all as specified and directed. |
| 14 | M&L finishing walls on newly preparedsurfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified and directed. |
| 15 | M&L finishing walls on Complete removal of old preparedsurfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified and directed. |
| 16 | Taking down old unserviceable/burn outLT cableof any size and capacity from the pole/wall/trenches after disconnecting of all electric connections etcNote:- Excavation andearth work will be measured and paid separately. |
| 17 | Supply,laying,jointing,testing andcommissioningXLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area6 sqmm 3 core connectedwith aluminium lugsconnectedby cramping toolsall as specified and directed at site.Note:- Excavation andearth work will be measured and paid separately. |
| 18 | Supply,laying,jointing,testing andcommissioningPVC tape/Extruded innersheathedCopper unarmoured service wire, 650/1100 volts grade cross sectional area1.5 sqmm 3 core connectedwith lugsconnectedby cramping toolsall as specified and directed at site. |
| 19 | M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed at site. |
| 20 | Supply and fix in replacement of 25 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etcall as specified and directed at site. |
| 21 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge |
| 22 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 23 | Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed. |
| 24 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 25 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 26 | Demolition of cement concrete in ground floor and paving built in cement concrete (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as directed.. |
| 27 | M&L for PCC(1:2:4) type B1 using 20 mm graded stone aggaregate in kerbs/coping /bed plates and like including weathering slightly rounded or chamfered completewith necessary use and waste fo formwork complete all as specified and directed at site. |
| 28 | M&L for PCC(1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and fillingincluding weathering slightly rounded or chamfered completewith necessary use and waste fo formwork complete all as specified and directed at site. |
| 29 | Dismantling cross- arms of MS ,channel or angle sections & Earth Wireetc complete all as specified and directed at site. |
| 30 | M&L mild steel as in cross arms bracing supports clamps and back planes fabricated from structural steel section including nut, bolts washers welding welding drilling holes for bolts in any shape and size as indicated or directedand inclusive of one proimer coat one undercoat one finishing coat of aluminium paint complete. paint complete to support the cables all as specified. |
| 31 | Supply, fabrication, installation, testing and commissioning of 3D Glow Sign Board made of 3mm thick ACP sheet (PVDF coated) back side of board covered with GI sheet 24SWG with 3D Acrylic letters (5 mm thick, 50mm depth) fitted with internal waterproof LED modules (IP55), including complete internal wiring, power supply, sealing, bonding and finishing all as specified, board size shall not exceed 5.00 m × 1.00 m, and all required stiffeners/supports MS framework, the board shall be designed to withstand minimum storm/wind load of 1.5 kN/m² (wind speed 50 m/s) as per IS 875 Part-3background color, acrylic letter color, LED color, number of letters and logo design will be decided by GE, and no extra payment shall be made for the number/size/design of letters height not exceeding 12 inch per letter or logo, the same being deemed included in the quoted rate,the LED mean time between failure arrangement should not be less than 40000 hrs, suitable for power supply 230 volts/ 50 Hz AC. The board shall be suitably braced on backside with iron clamps and channel or other applicable class mounting brackets, Fabrication should be done on Rectangular board having max 60 letters of characters in English/ Hindi language letter , character height not exceeding 355 mm one logo of dia not exceeding 550 mm and back depth upto 80 mm as per sample.Note:(i) MS supporting framework (MS angle/pipe) shall be measured and paid separately under relevant item.(ii) The quoted rate shall be inclusive of all materials, labour, cutting, routing, LEDs, wiring, adhesives, fasteners, testing, commissioning and all taxes.(iii) Payment for the Sign Board shall be made on Sqm basis. The number of boards required and the size/dimensions of each board shall be decided by the GE based on site requirements. The contractor shall execute the work accordingly, and the quoted rate per Sqm shall be deemed to include all allowances for variations in quantity and size. |
| 32 | S&F LED Glow Sign Board comprising 3 mm thick ACP sheet (PVDF coated) with letters/logo laser-cut as per approved font/write-up, the cut-out portions backed with translucent acrylic diffuser sheet (3 mm thick) and internally illuminated using waterproof LED modules (IP55) fixed on suitable MS framework. The illumination shall ensure uniform glow across all cut letters. The ACP board shall be supported on MS hollow section framework, including stiffeners, bracings, clamps, channels, nuts, bolts and complete mounting arrangements. The back housing shall be fabricated from 24 SWG GI sheet to form an enclosed light box ensuring dust and moisture protection. Board shall be designed to withstand minimum wind load of 1.5 kN/m² as per IS 875 Part-3. All internal wiring, LED power supplies/drivers, terminal connections, sealing, gaskets, adhesives and finishing shall be provided complete. Background colour, ACP shade, LED colour, font style and layout shall be as directed. LEDs shall have minimum 40,000 hours MTBF. Suitable for operation on 230V, 50 Hz AC supply. Complete all as specified and directed.Note :1. Size of sign board and colour will be decided by the department as per the site requirement.2.MS work shall be used for fixing of sign shall only be measured and paid separately under relevant item of Sch \"A\". Remaining items are deemed to be inclusive in the item rate.3. The quoted rate shall be inclusive of all materials, labour, fasteners, testing, commissioning and all taxes.4. Payment for the sign board shall be made on Sqm basis. The number of boards required and the size/ dimensions of each baord shall be decided by the GE based on site requirements. The contractor shall execute the work accordingly, and the quoted rate per sqm shall be deemed to inlclude all allowances for variations in quantity and size |
| 33 | S&F in repair Visible Sign Board of area exceeding 4 sqft but not exceeding 8 sqft each, fabricated from 5.00 mm thick engineering-grade acrylic (plastic) sheet of monolithic structure, capable of withstanding wide temperature variations (from cold conditions to high summer temperatures) and designed to resist high-velocity wind pressure, the board shall be framed and braced with MS structure, suitable to withstand strong wind loads, supplying and pasting new numerals/alphabets/logos using retro-reflective tape, machine-cut on a computer plotter, and all necessary fixing arrangements complete all as specified and directed.Note:(i) MS supporting framework (MS angle/pipe) shall be measured and paid separately under relevant item. |
| 34 | Supply and fix in replacementgarden lightlantern cast aluminium LED Bollard with soft 360 deg with clear acrylic cover with LEDlampcomplete all as specified and directed at site. Make :Crompton/Bajaj/Philips |
| 35 | S and F in repair polycarbonate junction loop in / loop out box of internal size 250 x 210 x 115mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 10 Amps MCB-01 No SPN, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed.Make :- HENSEL / SINTEX / HANSU of model HB 14. |
| 36 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthstripof size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I filling with charcoal dust , and common salt,including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EICNote :(i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate. |
| 37 | S&F GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and as directed. |