| 1 | SCHEDULE A BOQ |
| 2 | Supply, installation, testing and commissioning of electric induction motor of 3 phase, 415V, 3.75 kW / 5 HP capacity including chain pulley arrangement, gear box with ratio 1:60 with multi-stage gear reduction system as a single pair of gears including gear wheels etc by lifiting existing hangar door for extending existing door wheel shaft and fabrication work to install hangar door motor gear assmebly, motor to gear box chain driving work, motor cable stay wheels work and limit switch stay work complete all as specified and directed by Engr-in-Charge. |
| 3 | Supply & fixing of 3 phase, 415V 5HP DOL panel, push button for forwarding/ reverse movement of the doors, relays, limit switches, contactors, siren, ammeter, voltmeter indicating lamps and MCB SP/ SPN of various capacities and suitable connecting cable including VFD driver 3.75 to 4/5hp KW of capacity etc and necessary fabrication work required to install panel complete all as specified and directed by Engr-in-Charge. |
| 4 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as spcified and directed. |
| 5 | Supply and fix PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 sqmm 4 core complete all as spcified and directed. |
| 6 | Supply and fix of cable rolling wheel for laying of cable from panel to motor etc complete all as specified and directed by Engr-in-Charge. |
| 7 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly inground (Earth pit not less than 2.25 Mtr deep below normal ground level )with topedge of the plate not less than 1.5 Mtr belownormal ground level connecting with galvanizediron GI earth strip 32×6mm as earthing lead by means ofbolt nut check nuts and washersof galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate,earth work in any type of soil,all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessaryearth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing. |
| 8 | S&F of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip. |
| 9 | M&L Taking down the hanger sliding door shutter,each leaf of size 6.00 M (clear width) and not exceeding 11.00 M height, with mechanical crane without damaging existing structure, straightening of worn-out top & bottom rails, replace the existing rollers, tightened/replaced the loose nut and bolts, necessary /required welding of rails withhangar structure, and positioning of door shutter in same opening, replacement of broken locking arrangement etc. oiling, greasing, replacement of damaged covering sheet and positioning of door shutter in same opening for smooth functioning of hangar door shutter complete all as specified and as directed by Engr-in-charge.Notes : (i)Supply of hanger wheel will be measured and paid separately. However, labour element involved deemed to be included in the unit quoted rate.(ii) Necessary Scaffolding/Cranefor repair/replacement of sliding doors in hangars(Upto 13.00 mtr height) should be arranged by Contractor. (iii) Cost of thisalso included in this item. |
| 10 | Supply only Cast iron hanger wheels 230 mm dia and 25 mm to 40 mm thick, weight between 18 kg to 25 kg per each wheel including 25 mm dia x 100 mm Gun metal bushes shaft and other fixing materials for bottom railscomplete for smooth functioning of hanger door shutter all as specified and as directed by Engr-in-charge |
| 11 | Supply onlyMShanger wheels 230 mm dia and 25 mmto 40 mm thick, weight between 10 Kg to 22 Kg per each wheel including 25 mm dia Gun metal bushes for top rails,complete for smooth functioning of hanger door shutter all as specified and as directed by Engr-in-charge |
| 12 | M&L Cleaning/greasing/oiling of hanger wheel track at top of any description,welding of members if required tightening of screws/nuts,bolts of door and wheels etc including rectifying the alignment of top guide channel/rail/ angle etc complete for smooth functioning of hanger doors all as specified and as directed by Engr-in-charge. |
| 13 | M&L Cleaning/greasing/oiling of hanger wheel track at bottom of any description,welding of members if required tightening of screws/nuts,bolts of door and wheels etc including rectifying the alignment of top guide channel/rail/ angle etc complete for smooth functioning of hanger doors all as specified and as directed by Engr-in-charge. |
| 14 | M&L Welding in repairs, exc 2,5 cm but n exc 5 cm in length with thickness of metal to be welded n exc 6 mm all as specified and as directed by Engr-in-charge. |
| 15 | M&L Preparation of old steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of aluminium paintcomplete all as specified and as directed. |
| 16 | S&F in repairs Wind operated Turbo Ventilators of size 24 inches dia with FRB base plate material of construction for ventilator is high grade Industrial Aluminium of thickness not less than 0.5mm. Material of construction of hardware is stainless steel -304. Bearing shall be steel in completely enclosed and dust proof integrated housing and aligned with each other, it shall have capability to rotate at nearly zero wind speed. Turbo ventilator shall have UV stabilized powder coated and capable of static balancing shall have high exhaust capacity and there shall not be any exhaust problem due to air block draft. Fixing arrangement shall have high quality rubberised hardware to prevent leak during rain. All Turbo Ventilator to be installed by manufacturer\"s auth person only. Contractor shall give no leakage guarranty for a period of three years from the date of installation of Turbo Ventilator all as specified and as directed.Make : M/S Turbo Ventilators, M/S SVS Wind Driven Turbo Ventilators, M/s Arven Turbo Ventilators.Notes :Necessary Scaffolding/Cranefor repair/replacement of sliding doors in hangars(Upto 13.00 mtr height) should be arranged by Contractor.Cost of thisalso included in this item. |
| 17 | S&F in repairs grills for air circulation for turbo ventilator made with powder coated aluminium frames of size 600x600mm fixed in false ceiling grid thickness not less than 2mm complete all as specified and directed by the Engineer-in-ChargeNotes :- Necessary Scaffolding/Cranefor repair/replacement (Upto 13.00 mtr height) should be arranged by Contractor. Cost of thisalso included in this item. |
| 18 | Repair to leakage of galvalume sheet hangar roof by applying sealing compound around self tapping screws/ holes all as directed including adjusting roof sheets etc all as specified and as directed by Engr-in-charge.Notes :- Necessary Scaffolding/Cranefor repair to roof leakagein hangars(Upto 13.00 mtr height) should be arranged by Contractor. Cost of thisalso included in this item. |
| 19 | Dismantling plain or corrugated steel sheeting, any gauze, thickness, including Nainital or similar pattern roof coverings etc complete al as specified and directed.. |
| 20 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 21 | S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 22 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Complete all as specified and directed. |
| 23 | M&L of two coat of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincl preparation of surfaces complete all as specified and directed. |
| 24 | Material and labour for preparation of old painted steel& steelbased surfaces of any description over 10cm width or girth and applying onecoat of anti -rust PU based enamelpaint on stratural steel surfacesall as specified and as directed.(Rate including all necessay scafolding and saftey measures required for the work) |
| 25 | Supply & fixing \"E\" board (Everest make) 605 x 605 x 4 mm thick white prelaminated set & embosed, reinforced, designer ceiling board tiles of approved texture fixed at all height laid on hot dipped galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be powder coated, white,.the frame work shall comprises of main runner made from 0.33 mm thick galvanised steel sheet and of size 24 x 32 x 300 mm and spaced at 1200 mm center to center fixed to be structural soffits by approved hangers at 1200 mm rawl center, hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level and fasteners and screws etc., the last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall, flush fitting of 120 mm long cross tee (with double stiching) to be interlocked between main runners at 600 mm center to center, size 1200 x 600 mm modules, cross tee longer than 600 mm to be supported independently on 600 x 600 mm moduler to be formed by fitting 600 mm long cross tee centrally between the 1200 mm cross tee. Tee, perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19 x 19 mm and 300 mm long of white colour all as per manufacturer\"s instructions complete all as directed. |
| 26 | M & L 12 mm thick Toughened glass as in hingned doors, partitions automatic doors and similar work including cutting to shape, drilling holes requried complete all as specified and as directed |
| 27 | S & F Wall to Glass connecting patch (SS) to fix toughened glass at top and bottom complete all as specified and as directed |
| 28 | S & F Glass to Glass connecting patch (SS) to fix toughened glass at top and bottom complete all as specified and as directed |
| 29 | S & F Big L patch (SS) to fix toughened glass door at top complete all as specified and as directed |
| 30 | S & F Over panel patch (SS) to fix toughened glass door at top complete all as specified and as directed |
| 31 | S & F Bottom patch (SS) to fix toughened glass door at bottom complete all as specified and as directed |
| 32 | S & F Lock panel patch (SS) in fix toughened glass door at bottom complete all as specified and as directed |
| 33 | S & F H-type handle SS for glass door, hole length 1 feet and overall length 1.5 feet complete all as specified and as directed |
| 34 | S & F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 35 | Supply and lay UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100V with screened aluminium conductor of size 4 core 25 sqmm all as specified and directed. |
| 36 | Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/loose soil all as specified.Note : Only manual excavation will be allowed inside technical area. |
| 37 | Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed. |
| 38 | Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed. |
| 39 | M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable. |
| 40 | Supply and lay Fire bricks, size 230 x113 x 75 mm for the protection of LT UG Cable in trenches complete all as specified and directed by Engineer-in-Charge. |
| 41 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate electrodenot less than 1.5 m below normal ground level, connected to galvanized earth strip 32x6mm size by means of bolts, nuts, and washers of galvanized iron or steel all as shown in electrical plate No. 5 ofSSR Part I connected to earth test point includingprovisionof earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of strata, PCC pit with RCC cover, CI frame,char coal, salt &funnel etc complete all as specified or indicated including testing on completion.Rate to be considered for earth strip to be fixed 7.5 m long. |
| 42 | M& L of GI pipe (Light grade) for protection of LT cable fixed to walls/poles/road crossing including clamps complete of 50 mm bore complete all as specified and as directed. |
| 43 | Supply, Install and commissioning LT Panel Board outdoor type IP-65 made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with 200 A Aluminium bus bars and with 100 Amps, 25 KA breaking capacity Incoming MCCB suitable mounting plate, frame and canopy including foundation for busbar chamber to fix at min 1.5 feet above from ground level confirms to IEC61439-2 all as specified and directed |
| 44 | Supply, Install and commissioning LT Busbar chamber outdoor type IP-65 of size 0.6 X 0.6 X 0.45 Mtr made out of 3.15 mm thick MS sheet and angle Iron frame work for accomodate four Nos of sheet metal enclosures with suitable mounting plate, frame and canopy including foundation for busbar chamber to fix at min 1.5 feet above from ground level confirms to IEC61439-2 all as specified and directed. |
| 45 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20A double pole MCB inclding fixing at location all as specified and directed by Engineer-in-Charge. |
| 46 | M&L 3 core PVC insulated copper wire 2.5Sqmm all as specified and directed by Engineer-in-Charge. |