| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 2 | S&F angle iron posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. (height upto 6 mtr) |
| 3 | M&L plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 4 | M&Lfor preparation of new or old undecorated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamel paint including a coat of red oxide primer complete all as specified and as directed. |
| 5 | Supply only chain link MS galvanised fencing of size 75 x 75 x 3 mm as per sample approved by GE complete all as specified and directed. (Height upto 6 Mtr) |
| 6 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire all as specified and directed by Engr-in-Charge. (Height upto 6 Mtr) |
| 7 | S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the tother, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long Diameter of shank in 11 to 15 mm all as directed and specified. |
| 8 | S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening conforming to Fe-290 Gde E-165complete all as specified and directed. |
| 9 | M&L for round bars 10mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe 410-W as in fencing support complete all as specified. |
| 10 | Surface excavation n exc 30cm deep and averaging 15cm deep including getting out in hard/dense soil and removing debrish beyond MOD land complete all as specified and directed. |
| 11 | M&L for cement concrete type D-2 1:4:8 (using 40 mm graded stone graded stone aggregate) as in sub base for tiling, foundation filling etc. complete all as specified. |
| 12 | M&L for machine pressed colour glossy finished chequered cement concrete tiles of 300x300x25 mm thick set jointed and pointed in neat cement slurry in floors with gray cement and pigment including 15 mm thick screed bedding layer in cm 1:6complete all as specified and directed |
| 13 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for fdn etc for soft manhole, lying of pipe line etc not exc 10 sqm on plan and getting out any type of soil complete all as specified & directed.Note :- Insurance of workmen & cleaning of site, removal of all hindrance\"s/obstractions unforeseen item like Electric cable, Gas Pipe line etc permission from other department should be responsibility of contractor (MES will only assit in getting permission etc) restoring and getting the same constructed/Repaired/Replacement complete & nothing extra shall be payable. |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 15 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 16 | M&L cement concrete type C2 1:3:6 (using 40mm graded crushed stone agg) as in sub base of drains, sub base of floor etc. complete all as specified and directed. |
| 17 | M&L for brick work in cement mortar 1:6 using sub class B bricks, straight or curved on plan exc 6mtr mean radius complete all as specified and directed. |
| 18 | M&L for Ready Mix plaster 15mm thick on brick or concrete surface of internal and external walls finished even and fair surface without using extra cement complete all as specified and as directed. |
| 19 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed. |
| 20 | M&L for PCC 1:2:4 type B-1 using 20 mm gradedaggregate as in bed blocks, bed blocks of hold fasts,coping, PCC cill etc. complete all as specified and directed. |
| 21 | M&L for cement concrete 1:4:8 type D-2 using 40mm graded aggbed to drain pipes incl packing under and haunching against sides of 300mm dia (Internal dia) pipe afterthey are laid and tested(Thickness of concrete bed 150mm) complete all as specified & directed. |
| 22 | M&L for Reinforced concrete pipeclass NP2, 300mm dia laid in trenches & jointed in cement mortar (1:2) with collars complete all as specified and directed. |
| 23 | S&F factory made SFRC drain cover 100mm thick size exc 1.00 sqm but n.exc. 1.5 Sqm each with enravel marking of year of construction on top of each cover complete all as specified and directed. |
| 24 | M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 25 | M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base flooring complete all as specified and as directed. |
| 26 | M&L for Pre-polished 80mm thick precast PCC glossy interlocking blocks of grade M-40 single layer monolithic high density manufactured by electro vibro hydraulically operated block making machine confirming to IS-15658 : 2006coloured tile to make a pattern as directed, laid over and including 30mm thick sand cusion complete all as specified and directed by Engineer-in-Charge. |