| 1 | Exacavationin trenches , n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of pipes or for run lead joint and getting out in hard/dense soil. |
| 2 | Excavation in trenches, n exc 1.5m wide and m exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for soft/loose soil. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm. |
| 4 | Removing excavated soil n.exe 50Mtr & depositing wheredirected at a level n.exe 1.5m above the starting point |
| 5 | Demolition of cementConcrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 6 | S&F 3-layer PP-R P o l y p r o p y l e n e random copolymer) pipes 25mm dia SDR 11 UV, PN 10 stablised and a n t i m i c r o b i a l welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings in floors or laid in trenches etc. |
| 7 | S&F Double walled corrugated (DWC) Pipe conforming to IS 14930(Part-II) Pipesof Outer dia 63 mm and innder dia 50mmall as specified and as directed. |
| 8 | S&F Double walled corrugated (DWC) Pipe conforming to IS 14930(Part-II) Pipesof Outer dia 90 mm and innder dia 76mmall as specified and as directed. |
| 9 | Making connection of PP-R distribution branch with PP-R main outer dia of pipe 16 to 40 mm sizes by providing and fixing and fixing tee including cutting and making fusion joint etc. |
| 10 | S&F 3-layer PP-R P o l y p r o p y l e n e random copolymer) pipes 32 mm dia SDR 11 UV, PN 10 stablised and a n t i m i c r o b i a l welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings in floors or laid in trenches etc. |
| 11 | S&F 3-layer PP-R P o l y p r o p y l e n e random copolymer) pipes 63 mm dia SDR 11 UV, PN 10 stablised and a n t i m i c r o b i a l welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings in floors or laid in trenches etc. |
| 12 | S&F 3- layer PP-R Polypropylene random copolymer) concealed pipes 40 MM outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches. |
| 13 | M & L for replacement of PP-R Gate valves (brass insert) of size 32 mm boreas per requirement all as directed and as specified. |
| 14 | S&F PP-R Gate valves (brass insert) 25 mm as per requirement of the site |
| 15 | S&F PP-R Gate valves (brass insert) 32mm as per requirement of the site |
| 16 | S&F PP-R Gate valves (brass insert) 63 mm as per requirement of the site |
| 17 | S&F PP-R Gate valves (brass insert) 40 mm as per requirement of the site |
| 18 | S & FRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacityhoisted and fixed in position all as specified in SSR Part I |
| 19 | M&Lfor PCC 1:3:6B-2 Type Using 40 mm graded stone aggregate as in filling and mass convrete all as specified and directed . |
| 20 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacityhoisted and fixed in position all as specified in SSR Part I |
| 21 | M&L for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in mass concrete in coping of existing and new PCC/steel poles etc complete all as specified and directed. |
| 22 | S & F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 2000 Ltr capacityhoisted and fixed in position all as specified in SSR Part I |
| 23 | S & Fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (11.0 metres long) |
| 24 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 5000 Ltr capacityhoisted and fixed in position including tank nipple and other connected fittings all as specified and directed |
| 25 | M&L for Making connection of PP-R distribution branch 50 to 75 mm with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc |
| 26 | S&F Ball valves high pressure of PTMT 25 mm bore with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.(Minimum weight 25mm-455gms) |
| 27 | S&F Ball valves high pressure of PTMT 40 mm bore with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.(Minimum weight - 690 gms) |
| 28 | M&Lfor submain wiring in steel conduit alongwith earth wire connection tapping from the line / connecting up from the junction box to the fitting with the two run ofPVC insulated copper conductor, single core2.5 sqmm FRLS cable for phase and neutral and one run of 2.5 sq mm FRLS cable of green colour for earting connected to earth dolly all as specified and directed.Note:-Three run of cable copper conductor 2.5 sqmmand steel conduit(20mm dia) shall be measured as one unit length. |
| 29 | M & L forOne 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 4.0 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 30 | S&F Switch Piano Flush button single pole one way 15/16 Amp. |
| 31 | S&F socket outlet 2 in 1 ,3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. |
| 32 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade,multi stranded, cross-sectional area 06 Sqmm 2 core |
| 33 | Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional areas:-.240 Sqmm 3.5 Core |
| 34 | Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional areas:-50 Sqmm 3.5 Core |
| 35 | S&F PVC Junction box sheet moulding compound type (SMC) off white colour with hinged type door of size 250 x 200 x 100mm (internal) comprising bakelite 16 sqmm size terminal block 4 ways-1 No, MCB SPN - 01 No housed inside junction box with neutral bus bar, internally wired, complete fixed on pole with suitable MS clamps bolts nuts and washers including taking out old junction box all as specified and as directed.Make:-Sintex/Prayag/Indoasian |
| 36 | Material and labour for painting of existing steel tubularstreet light polesabove the PCC foundation/coping surface, etc with a coat of synthetic enamel paint alumium Paint, cleaning of existing surface with wire brush complete all as directed by Engineer-in -charge. |
| 37 | Supply and fixing LED flood light 120W watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver,lamp and fixing arrangement all as specified and directed. |
| 38 | S&F testing and commissioning RO Plant 250 LPH with Multimedia Chamber, Multi Distributon Regulator, Strainer, Jumbo spun,SSSKIDE - 250 LPH, High pressure pump 01 HP, Raw water pump 01 HP, Dosing Pump, Membrane and membrane housingPressure Gauge, Flow Meter, UV Strelizer, Filter media, Dosing System 100 Ltr Tank, CPVC/UPVC Pipe connection with all fittings, MS Stand for 500 Ltr Tank, Capacityall as spefied and directed. |
| 39 | Supply, installation, commissioning and testing in replacementpowder coated factory made out door type double door panel board confirming to IP 66 protaction, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- INCOMING(a)Incoming MCCB 4 pole 200 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting– 01 No(b) Incoming MCCB 4 pole 320 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting– 01 No(c) Digital Multifunction meter (C,A, PF, KW, KWH)-01 No(d) LED Indicator Lamp R,Y,B - 06 Nos(e) CT 300/5A, Cl-1, Tape Wonded. - 03 Nos(f)CT 200/5A, Cl-1, Tape Wonded.- 03 Nos (g)6 to -32 Amp MCB SP- 06 Nos OUTGOING (Non Essential)(a) Out going MCCB 4 pole 125 Amp 25 KAwith adjustable thermal setting – 01 No(b)Sprader Link for 125A 4 P, MCCB (Set of 8 Pcs) 01(c)100A, 4P, 25KA, MCCB with TM. -02(d)Sprader link for 100A, 4P, MCCB (Set of 8 Pcs) -02(e)63A, 4P, 25KA, MCCB with TM-01OUTGOING ( Essential)(a) Out going MCCB 4 pole 100 Amp 25 KAwith adjustable thermal setting – 02 No(b)Sprader Link for 100A 4 P, MCCB (Set of 8 Pcs)-02(c)63A, 4P, 25KA, MCCB with TM.-01(d)32A, 4P, 25KA MCB \"C\" Series-03(e)32A, DP, 10KA, MCB \"C\" Series-01 |
| 40 | M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed.. |