| 1 | Servicing of Diesel engine Generating sets 200 KVA to 400 KVA Rating to be carried out as per schedulegiven as under.B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i) Change lubricating oil (ii) Change lubricating oil filters(iii) Change fuel filters(iv) Change coolant (iv) Check Engine wiring for damage (v) Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves(ii) Steam clean engine (iii) Replace hoses if required (iv) Check turbo charger mounting nuts (v ) Check engine oil heater (vi) Clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii) Clean fuel from inside (ix) Change engine oil. Note : (i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 2 | Servicing of Diesel engine Generating sets 10 KVA to 160 KVA Rating to be carried out as per schedulegiven as under.B - check :- (Every 100 Hrs or 6 months whichever is earlier)(i) Change lubricating oil (ii) Change lubricating oil filters(iii) Change fuel filters (iv) Change coolant (v) Check Engine wiring for damage(vi) Drain fuel supply tank(vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x) Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii) Steam clean engine(iii) Replace hoses if required (iv) Check turbo charger mounting nuts(v) Check engine oil heater (vi) Clean rediator(vii) Inspect following parts and replace if required (Alternator,starter etc )(viii) Clean fuel from inside (ix) Change engine oil. Note : (i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 3 | Supply and fix new Air filters cartridge elements with \"O\" ring for 10 to 50 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 4 | Supply and fix new air filters cartridge elements with \"O\" ring for 62.5 to 125 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 5 | Supply and fix new air filters cartridge elements with \"O\" ring for 200 to 400 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 6 | Supplyand fix fuel oil filter cartridge elements with \"O\" ring for 10 to 50 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 7 | Supplyand fix fuel oil filter cartridge elements with \"O\" ring for 62.5 to 125 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 8 | Supplyand fix fuel oil filter cartridge elements with \"O\" ring for 200 to 400 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 9 | Supplyand fixlubricant oil filter cartridge elements with \"O\" ring for 10 to 50 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 10 | Supplyand fixlubricant oil filter cartridge elements with \"O\" ring for 62.5 to 125 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 11 | Supplyand fixlubricant oil filter cartridge elements with \"O\" ring for 200 to 400 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 12 | Supplyand fixfuel water separator filters cartridge elements with \"O\" ring for 10 to 50 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 13 | Supplyand fixfuel water separator filters cartridge elements with \"O\" ring for 62.5 to 125 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 14 | Supplyand fixfuel water separator filters cartridge elements with \"O\" ring for 200to 400 KVA DG set complete all as specified and directed. (Make : Kirlosker/cummins/fleetguard) |
| 15 | Supply and filling engine oil 15W40 suitable for Kirloskar/Cummins engine complete all as specified and directed.(Make: Castrol / Shell / Bosch / Kirloskar KOEL. |
| 16 | Supply and filling coolantsuitable for Kirloskar/Cummins engine complete all as specified and directed. |
| 17 | Draining out water from the radiator, dismantling opening and taking out radiator from the foundation and transporting to civil workshop for repair including Maintenance and Servicing of Radiator and cleanning the radiator thoroughly with cleaning agent to improve the efficiency of the radiator, welding / soldering / brazing of radiator for the undermentioned DG sets complete all as specified and directed.Note :- (a) Contractor will carry out comrehensive maint and servicing listed in respective items through qualified tecnical staff only. (b) Contractor will gaurantee for one year from the certified date of completion for the repair work carried out.(c) Any fault occured during gaurantee period shall be rectfied by the contractor with out any extra cost to the department.(d) Coolant for radiator shall be measured and paid separately . |
| 18 | 400 KVA DG set |
| 19 | 200 KVA to 250 KVA DG sets |
| 20 | 100 KVA to 125 KVA DG sets |
| 21 | 50 KVA to 82.5 KVA DG sets |
| 22 | 10 to 40 KVA DG set |
| 23 | Opening and taking down unserviceable fuel injection pump and transportation to civil wksp for repair, maintenance andservicing offuel injection pump (FIP) including phasing & caliberation of Fuel injection pump, replacement of injectors, nozzles etc if any found defective,and refitting the same in position for smooth and efficient functioning of FIP for the under mentioned DG sets complete all as specified and directed.Note : - (a) Repairs will be carried out from authorised workshop of manufacturer of DG set. (b) Contractor will give gaurantee for one year from the date of completion of the repair work carried out. Any fault occured during gaurantee period shall be rectified by the contractor with out any extra cost to the department. |
| 24 | 400 KVA DG set |
| 25 | 200 KVA to 250 KVA DG sets |
| 26 | 100 KVA to 125 KVA DG sets |
| 27 | 50 KVA to 82.5 KVA DG sets |
| 28 | 10 to 40 KVA DG set |
| 29 | Supply and fixing diesel pipe from tank to diesel filter suitable dia both side factory fitted union/elbow heavy duty each 5 mtr in length complete all as specified and directed. |
| 30 | Supply and fixing diesel pipe from filter to fuel pump suitable dia both side factory fitted union/elbow heavy duty each 1.5 mtr in length complete all as specified and directed. |
| 31 | Supply and fixing diesel return pipe from pump to diesel tank suitable dia both side factory fitted union/elbow heavy duty each 5 mtr in length complete all as specified and directed. |
| 32 | Supply and fixing oil pipe from engine pump to primary oil filter suitable dia both side factory fitted union/elbow heavy duty each 1.5 mtrin length complete all as specified and directed. |
| 33 | Supply and fixing oil pipe from oil pump to oil filter suitable dia both side factory fitted union/elbow heavy duty each 3 mtrin length complete all as specified and directed. |
| 34 | Supply and fixing oil pipe from primary oil filter to secondary oil filter suitable dia both side factory fitted union/elbow heavy duty each 3 mtrin length complete all as specified and directed. |
| 35 | Supply and fixing rubber hose pipe set suitable for 200 KVA to 400 KVA Kirloskar/Cummins DG sets complete all as specified and directed. |
| 36 | Supply and fixing rubber hose pipe set suitable for 100 KVA to 125 KVA Kirloskar/Cummins DG sets complete all as specified and directed. |
| 37 | Supply and fixing rubber hose pipe set suitable for 50 KVA to 82.5 KVA Kirloskar/Cummins DG sets complete all as specified and directed. |
| 38 | Supply and fixing rubber hose pipe set suitable for 10 KVA to 40 KVA Kirloskar/Cummins/Mahindra DG sets complete all as specified and directed. |
| 39 | Supply and fixing oil pressure gauge suitable for 400 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 40 | Supply and fixing oil pressure gauge suitable for 200 to 250 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 41 | Supply and fixing oil pressure gauge suitable for 100 to125 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 42 | Supply and fixing oil pressure gauge suitable for 50 to 82.5 KVA DG sets complete all as specified and directed.Make:- Kirloskar/Cummins engine or as approved by GE. |
| 43 | Supply and fixing oil pressure gauge suitable for 10 to 40 KVA DG sets complete all as specified and directed.Make:- Kirloskar/Cummins engine/Mahinra |
| 44 | Supply and fixing flow fuel gauge suitable for 400 KVA DG sets complete all as specified and directed.Make:- Kirloskar/Cummins engine or as approved by GE. |
| 45 | Supply and fixing flow fuel gauge suitable for 200 to 250 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 46 | Supply and fixing flow fuel gauge suitable for 100 to125 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 47 | Supply and fixing flow fuel gauge suitable for 50 to 82.5 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 48 | Supply and fixing flow fuel gauge suitable for 7.5 to 40 KVA DG sets complete all as specified and directed.Make:- Kirloskar/Cummins engine/Mahinra |
| 49 | Supply and fixing selector switch suitable for 400 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 50 | Supply and fixing selector switch suitable for 200 to 250 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 51 | Supply and fixing selector switch suitable for 100 to125 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 52 | Supply and fixing selector switch suitable for 50 to 82.5 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine or as approved by GE. |
| 53 | Supply and fixing selector switch suitable for 10 to 40 KVA DG sets complete all as specified and directed. Make:- Kirloskar/Cummins engine/Mahinra |
| 54 | Supply and fixing indicator lamp set (R Y B) complete all as specified and directed. |
| 55 | Supply and fixing Soleniod switch any type for self starter complete all as specified and directed. |
| 56 | Supply and fixing Carbon brush set any type with brush holder complete all as specified and directed. |
| 57 | Supply and fixing Drive End Plunger complete all as specified and directed. |
| 58 | Rewinding offield coils of Self starter with existing gauge supper enamelled copper wire complete all as specified and directed. |
| 59 | Supply and fixing bearing for repair of Self Starter complete all as specified and directed. |
| 60 | Supply and fixing injector over flow pipe including taking down unserviceable pipe complete all as specified and directed. |
| 61 | Supply and fixingnon return benjo bolt including taking down unserviceable benjo bolts complete all as specified and directed. |
| 62 | Supply and fixing maintenance free battery 12 volt 180 AH sealed in MS container by manufacturing unit, having inbuilt charge indicators for indicating the Main input, bty charging, bty full including three metre charging lead with three pin top complete all as specified and directed. |
| 63 | All as per Srl Item No. 52.00 here in before above but of capacity 12 volt 65 AH. |
| 64 | Material and Labour for repair of AMF panel suitable for 62.5 KVADG set including replacing of the unserviceable spare parts as per the existing capacity, contactor, auxillaiary supply 240 volts AC, CT of suitable ratio,timer for delay, DC voltmeter, Ammeter, emergency stop, line operating monitoring relay, MCBs, MCCBs with spreader, plugin relay with base 8 pin, push button etc including painting with two coats of super enamel paint, testing on Load complete all as specified and directed. |
| 65 | Supply and FixingDigital Ammeter 0-500 A of size 96 sqmm with selector switch-01 No. complete all as specified and directed.Make:L&T/ Schneider/Legrand/ABB / Seimens/ C&S electricals. |
| 66 | Supply and Fixing control relay contactors of MXO type operatable at AC/DC supplies with NO/NC add ON as per the existing site requirement complete all as specified and directed. |
| 67 | Supply and Fixing in replacement power contactor 50-100 Amps capacity suitable for AMF panel of DG sets as per matching to existing complete all as specified and directed. |
| 68 | Supply and Fixing in replacement of under voltage relay suitable for DG set of capacity 10 KVA to 62.5 KVA DG Sets complete all as specified and directed. |
| 69 | All as per Srl Item No. 58.00 here in before above but for 100 KVA to 250 KVA DG Sets. |
| 70 | All as per Srl Item No. 58.00 here in before above but for 400 KVA DG Sets. |
| 71 | Supply and Fixing in replacement of 3 Phase digital multi function meter with suitable accessories and fixing arrangement complete all as specified and directed. Make:L&T/ Schneider/Legrand/ABB / Seimens/ C&S electricals. |
| 72 | Maintenance and servicing of alternator 12/24Volt of DG set installed at various installations including transportation to civil wksp for repair and servicing/overhauling including replacing of worn out parts like, bearing, carbon brush, rewindingto alternator winding wth suitale size super enamelled copper wire, insulating material including warnishing with air dry varnish,nut bolts and washer etccompleteand refitting the alternator in position for smooth functioning of DG sets and testing on full load for the entire satisfaction of the Engr-in-charge complete all as specified and directed.Note:- (a) Contractor will carry out comprehensive maint and servicing listed in respective items through qualified technical staff only. (b)Contractor will give gaurantee for one year from the date of completion of repair work carried out.(c) Any fault occured during guarantee period shall be rectified by the contractor without extra cost to the department. |
| 73 | For 400 KVA DG sets |
| 74 | For 200 KVA to 250 KVA DG sets |
| 75 | For 100 KVA to 125 KVA DG sets |
| 76 | For 50 KVA to 82.5 KVA DG sets |
| 77 | For 10 KVA to 40 KVA DG set |
| 78 | Dismantling opening and taking down unserviceable wiring of the control panel of DG set of capacity upto 400 KVA and rewiring complete with suitable size PVC insulated copper wire including taking down all accessories like oil pressure gauge, fuel gauge, indicator lamps,selector switches and starting switch and refixing the serviceable items complete all as specified and directed.Note:- (a) Unserviceable items shall be measured and paid separately under respective items (b) Rates of wiring is deemed to be included in quoted rates |
| 79 | Material and labour for repairs ofdoors to accoustic enclosure with necessary hinges made of stainless steel including welding soldering as required at site suitable for up to 400 KVA DG sets complete all as specified and directed. |
| 80 | Material & Labour for removing old rusted paintfrom complete DG Set surfaces ofthe upto 82.5 KVA KVA capacity complete with one coat of Primer andtwo coat ofspray painting one by one with existing colour paint synthetic enamel type including writing Ser No of DG set complete all as specified and directed. |
| 81 | All as per Srl Item No. 65.00 here in before above but for capacity 100 to 125KVA. |
| 82 | All as per Srl Item No. 65.00 here in before above but for capacity 200 to 250KVA. |
| 83 | All as per Srl Item No. 65.00 here in before above but for capacity 400 KVA. |
| 84 | Material & Labour in replacement of following unserviceable spares for water manifold and Radiator upto 400 KVA DG set. . |
| 85 | Radiator rubber hoses. |
| 86 | Clamp for hump hose. |
| 87 | Hose clamps. |
| 88 | Hump hose |
| 89 | Supply & fix in replacement of unsv engine oil control pressure switch suitable upto 400 KVA DG set of make Kirloskar / Cummins/ as per existing complete all as specified and directed. |
| 90 | Dismantling exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as specified and directed for the following capacity DG Sets :- |
| 91 | 400 KVA DG set |
| 92 | 200 KVA to 250 KVA DG sets |
| 93 | 100 KVA to 125 KVA DG sets |
| 94 | 50 KVA to 82.5 KVA DG sets |
| 95 | 10 to 40 KVA DG set |
| 96 | Supply and fixing in replacement electronic speed control unit with necessary connection terminal suitable for up to 400 KVA DG sets complete all as specified and directed. Make:- Kirloskar /Greaves or as approved by GE. |
| 97 | Supplyand fixing engine exhaust outlet /inlet valve suitable for 200 KVA to 400 KVA Kirloskar/Cummins engine / as per existing complete all as specified and directed. |
| 98 | All as per Srl Item No. 73.00 here in before above but for 100 KVA to 125 KVA DG Set. |
| 99 | All as per Srl Item No. 73.00 here in before above but for 50 KVA to 82.5 KVADG Set. |
| 100 | All as per Srl Item No. 73.00 here in before above but for 10 KVA to 40 KVADG Set. |
| 101 | Supply and fixing cylinder head gasket suitable for Gen Set 200 KVA to 400 KVA capacity make as per existing at ground complete all as specified and directed. |
| 102 | All as per Srl Item No. 77.00here in before above but for 100 KVA to 125 KVA. |
| 103 | All as per Srl Item No. 77.00here in before above but for 50 KVA to 82.5 KVA. |
| 104 | All as per Srl Item No. 77.00here in before above but for 10 KVA to 40 KVA. |
| 105 | Supply and fixing piston assembly suitable for Gen Set 200 KVA to 400 KVAmake as per existing at site complete all as specified and directed. |
| 106 | All as per Srl Item No. 81.00here in before above but for 100 KVA to 125 KVA. |
| 107 | All as per Srl Item No. 81.00here in before above but for 50 KVA to 82.5 KVA. |
| 108 | All as per Srl Item No. 81.00here in before above but for 10 KVA to 40 KVA. |
| 109 | Supply and fixing Piston ring and oil ring suitable for Gen Set 200 KVA to 400 KVAmake as per existing at site complete all as specified and directed. |
| 110 | All as per Srl Item No. 85.00here in before above but for 100 KVA to 125 KVA. |
| 111 | All as per Srl Item No. 85.00here in before above but for 50 KVA to 82.5 KVA. |
| 112 | All as per Srl Item No. 85.00here in before above but for 10 KVA to 40 KVA. |
| 113 | Supply and fixing main bearing suitable for Gen Set 200 KVA to 400 KVAmake as per existing at site complete all as specified and directed. |
| 114 | All as per Srl Item No. 89.00 here in before above but for 100 KVA to 125 KVA. |
| 115 | All as per Srl Item No. 89.00 here in before above but for 50 KVA to 82.5 KVA. |
| 116 | All as per Srl Item No. 89.00 here in before above 10 KVA to 40 KVA. |
| 117 | Supply and fixing small and big end bearing suitable for Gen Set 200 KVA to 400 KVAmake as per existing at site complete all as specified and directed. |
| 118 | All as per Srl Item No. 93.00 here in before above but for 100 KVA to 125 KVA. |
| 119 | All as per Srl Item No. 93.00 here in before above but for 50 KVA to 82.5 KVA. |
| 120 | All as per Srl Item No. 93.00 here in before above but for 10 KVA to 40 KVA. |
| 121 | Supply and fixing oil seals off sizes suitable for Gen Set 200 KVA to 400 KVAmake as per existing at site complete all as specified and directed. |
| 122 | All as per Srl Item No. 97.00 here in before above but for 100 KVA to 125 KVA. |
| 123 | All as per Srl Item No. 97.00 here in before above but for 50 KVA to 82.5 KVA. |
| 124 | All as per Srl Item No. 97.00 here in before above but for 10 KVA to 40 KVA. |
| 125 | Taking down dynamo assembly from engine upto 400 KVA for repair/replacement of worn out parts and refixing the sameincluding cheking of proper charging of batteries complete all as specified and directed. |
| 126 | Dismantling opening and taking down unserviceable wiring of the control panel of DG set Cap upto 400 KVA and rewiring complete with suitable size PVC insulated copper wire including taking down all accessories like oil pressure gauge, fuel gauge, indicator lamps,selector switches and starting switch and refixing the serviceable items complete all as specified and directed.Note:- (a) Unserviceable items shall be measured and paid separately under respective items (b) Rates of wiring is deemed to be included in quoted rates |
| 127 | Supply and Fixing in replacement battery charger set suitable for 12V DC battery operating on 230 V AC supply complete all as specified and directed. |
| 128 | Supply and Fixing in replacement battery charger set suitable for 24 V DC battery operating on 230 V AC supply complete all as specified and directed. |
| 129 | Material & Labour for automatic voltage regulator suitable for 10 KVA to 40 KVA complete all as specified and directed. |
| 130 | All as per Srl Item No. 105.00 here in before above but for 50 KVA to 82.5 KVA. |
| 131 | All as per Srl Item No. 105.00 here in before above but for 100 KVA to 125 KVA. |
| 132 | All as per Srl Item No. 105.00 here in before above but for 200 KVA to 250 KVA. |
| 133 | Labour and T&P for shifting after disconnecting/dismantling primary & secondary connection carefully of servo voltage stablizer out door/indoor type complete of capacity 50 KVA to 500 KVA from its foundation and safely shifting from one place to another place as directed by Engineer-in-charge and reconnection of cabling ,earthing ,installation, testing and commissoning of the servo voltage stablizer complete all as specified and directed. Note:- Cost of Necessary tools and plants such as Vehicle, hydra/Crane etc deemed to be included in the unit quoted rate . |
| 134 | Material & Labour for servo stabilizer externally spray painting with one coat of synthetic enamel paint of grey colour after cleaning surface throughly with thinner and scrapper and preparing the surface to required standard including writing and making such as MES No on the body of servo stabilizer of capacity upto 100 KVA complete all as specified and directed. |
| 135 | Material & Labour for servo stabilizer externally spray painting with one coat of synthetic enamel paint of grey colour after cleaning surface throughly with thinner and scrapper and preparing the surface to required standard including writing and making such as MES No on the body of servo stabilizer of capacity 125 KVA to 500 KVA complete all as specified and directed. |
| 136 | Material & Labour for complete servicing of working/non working existing servo voltage stabilizer automatic operation three phase of various makes & capacity upto 100 KVA at different locations by dismantling / opening the stabilizer for checking the parts/components, circuit for proper functioning, cleaning inside the stabilizer, replacement of defective minor items i,e. screws, lugs, cut out/fuses etc., reassembling the stabilizer, testing on rated equipment load for automatic operation to stabilizer standard output voltage complete all as specified and directed.Note:- (i) Cost of Necessary tools and plants such as Vehicle, hydra/Crane etc deemed to be included in the unit quoted rate. (ii)Any spare part of stabilizer if found defective will be measured & paid as Supply & Fix under respective item of this Sch. |
| 137 | Material & Labour for complete servicing of working/non working existing servo voltage stabilizer automatic operation three phase of various makes & capacity exceeding 125 KVA but not exceeding 500 KVA at different locations by dismantling / opening the stabilizer for checking the parts/components, circuit for proper functioning, cleaning inside the stabilizer, replacement of defective minor items i,e. screws, lugs, cut out/fuses etc., reassembling the stabilizer, testing on rated equipment load for automatic operation to stabilizer standard out put voltage complete all as specified and directed. Note:- (i) Cost of Necessary tools and plants such as Vehicle, hydra/Crane etc deemed to be included in the unit quoted rate. (ii)Any spare part of stabilizer if found defective will be measured & paid as Supply & Fix under respective item of this Sch. |
| 138 | Supply & Fix in replacement of push button switch as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 139 | Supply & Fix in replacement of Auto manual switch as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 140 | Supply & Fix inreplacement of Micro switch as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 141 | Supply & Fix inreplacement of PCB holder as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 142 | Supply & Fix inreplacement of Carbon bush as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 143 | Supply & Fix inreplacement of Carbon bush holder as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 144 | Supply & Fix inreplacement of Trigger transformer as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 145 | Supply & Fix inreplacement of Amp meter selector switch as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 146 | Supply & Fix inreplacement of Shunt coil, 220 Volt, AC, as per existing Make and suitable for servo stabilizer of capacity upto 500 KVA complete all as specified and directed. |
| 147 | Supply & Fix inreplacement electronic circuit card (PCB) suitable for automatic threephase stabilizer 100 KVA capacity of various make with high & low voltage cutout device but excluding ICS complete all as specified and directed. |
| 148 | Supply & Fix inreplacementelectronic circuit card (PCB) suitable for automatic threephase stabilizer 125 KVA capacity of various make with high & low voltage cutout device but excluding ICS complete all as specified and directed. |
| 149 | Supply & Fix inreplacementelectronic circuit card (PCB) suitable for automatic threephase stabilizer 200 KVA to 300 KVA capacity of various make with high & low voltage cutout device but excluding ICS complete all as specified and directed. |
| 150 | Supply & Fix in replacementelectronic circuit card (PCB) suitable for automatic threephase stabilizer 500 KVA capacity of various make with high & low voltage cutout device but excluding ICS complete all as specified and directed. |
| 151 | Supply & Fix inreplacement Servo motor with RC net work 10Kg Suitable for 3 Phase Voltage Stabilizer ,100 to 125 KVA, 415 V, 50 Hz complete all as specified and directed. |
| 152 | Supply & Fix inreplacement Servo motor with RC net work 10Kg Suitable for 3 Phase Voltage Stabilizer ,250 to 500 KVA, 415 V, 50 Hz complete all as specified and directed. |
| 153 | Supply & Fix inreplacement Control circuit Low/high Cut offwith relay suitable for 3 Phase Voltage Stabilizer ,100 to 500 KVA, 415 V, 50 Hz complete all as specified and directed. |
| 154 | Supply & Fixin replacement Gasket Sets suitable for 3 Phase Voltage Stabilizercomplete all as specified and directed. |
| 155 | Supply & Fix inreplacement gear and driver assembly of capacity exceeding 75 KVA but not exceeding 200 KVA per phase of servo vloltage stabilizercomplete all as specified and directed. |
| 156 | Supply & Fix inreplacement gear and driver assembly capacity exceeding 200 KVA but not exceeding 500 KVA per phase of servo vloltage stabilizercomplete all as specified and directed. |
| 157 | Material & Labour for Main Boosting TR rewinding (Copper winding heavy duty) Suitable for 3 Phase Voltage Stabilizer 100 to 200 KVA,415 V,50 Hz, including dismantling old windingcomplete all as specified and directed. |
| 158 | Material & Labour for Main Boosting TR rewinding (Copper winding heavy duty) Suitable for 3 Phase Voltage Stabilizer ,250 to 500 KVA, 415 V, 50 Hz, including dismantling old windingcomplete all as specified and directed. |
| 159 | Material & Labour forDimmer (variac)rewinding with Copper windingSuitable for 3 Phase Voltage Stabilizer ,100 to 200 KVA, 415 V, 50 Hz,including dismantling old windingcomplete all as specified and directed. |
| 160 | Material & Labour for Dimmer (variac)rewinding with Copper windingSuitable for 3 Phase Voltage Stabilizer ,250 to 500 KVA, 415 V, 50 Hz, including dismantling old windingcomplete all as specified and directed. |
| 161 | Supply & Fix in replacement of Rotary pump with suction pipe not less than 1 Mtr complete all as specified and directed. |
| 162 | Supply & Fix in replacement of Electronic PCB Control Card (Sensing Card) complete all as specified and directed. |
| 163 | Transformer oil EHV confirming to IS-335 of 1983 of mineral oil grade \"B\" having a high dielectric strength not less than 40 KV including taking out existing complete all as specified and directed. |
| 164 | Supply & Fix in replacement LT bushing assembly with brass terminal, neoprene rubber gasket and washers etc complete with accessories for Servo stabilizers transformer complete all as specified and directed. |
| 165 | Material & Labour for filtration / dehydration of old/existing transformer oil including topping up of transformer oil as required in the Servo stabilizer transformers of different capacity, installed at various locations with suitable capacity of filtration machine to achieve dielectric strength minimum 60 KV complete all as specified and directed.Note :- (i) All necessary T&P / testing equipment shall be provided by the contractor at his own cost. No extra payment shall be made to the contractor. (ii) New Transformer Oil required for topping up shall be paid for separately under relevant item of this Schedule. |
| 166 | Material & Labour for writing of SM/MES No with white/black syntheic enamel paint on the alternator of DG set and voltage stablizer/Laundary Machines complete all as specified and directed. |
| 167 | Supply and fixing in replacement of burnt defectivewash motor for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 168 | Supply and fixing in replacement of burnt defectiveSpin motor for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 169 | Supply and fixing in replacement of burnt defectiveWasher Drain pump for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 170 | Supply and fixing in replacement of Motor Beltfor Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 171 | Supply and fixing in replacement of wash Timerfor Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 172 | Supply and fixing in replacement of SpinTimerfor Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 173 | Supply and fixing in replacement of BuzzerAlarm for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 174 | Supply and fixing in replacement of Wash Selector Swithchfor Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 175 | Supply and fixing in replacement of Drain Selector for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 176 | Supply and fixing in replacement of Gear Box for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 177 | Supply and fixing in replacement of Pully for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 178 | Supply and fixing in replacement of Drain Valve for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 179 | Supply and fixing in replacement of Buffer Seal for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 180 | Supply and fixing in replacement of Drain Rubber Set for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 181 | Supply and fixing in replacement of Spin Motor Shocker for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 182 | Supply and fixing in replacement ofSpin Motor Pully for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 183 | Supply and fixing in replacement of9.5 MFD Capacitor for Laundary Machineswith new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing complete all as specified and directed. |
| 184 | Supply and Fix in replacementMCCB TPN630 Amps , 415 Volts, 50 KA ,4 Pole, Ics=100% Icu , with microprocessor release IPRE+ (4 pole)overload adjustable short circuit adjustabletypeincl complete connection complete all as specified and directed.. |
| 185 | Supply and Fix in replacementMCCB TPN400 Amps , 415 Volts, 50 KA ,4 Pole, Ics=100% Icu , with microprocessor release IPRE+ (4 pole)overload adjustable short circuit adjustabletypeincl complete connection complete all as specified and directed. |
| 186 | Supply and Fix in replacementMCCB TPN250 Amps , 415 Volts, 36 KA ,4 Pole, Ics=100% Icu , with microprocessor release IPRE+ (4 pole) overload adjustable short circuit adjustabletypeincl complete connection complete all as specified and directed. |
| 187 | Supply and Fix in replacementMCCB TPN160 Amps , 415 Volts, 25 KA ,4 Pole, Ics=100% Icu , with microprocessor release IPRE+ (4 pole)overload adjustable short circuit adjustabletypeincl complete connection complete all as specified and directed. |
| 188 | Supply and Fix in replacementMCCB 3 poleTPN100 Amps , 415 Volts, 16 KA ,4 Pole, Ics=100% Icu , with microprocessor release IPRE+ (3 pole)overload adjustable short circuit adjustabletypeincl complete connection complete all as specified and directed. |
| 189 | Supply and fixing in repair On load change over switch415 V, 4 pole, 630 Amps with sheet steel enclosure capacity fixed on DG Set incl necessary connection of cables from LT panels to change over switch complete all as specified and directed. |
| 190 | Supply and fixing in repair On load change over switch415 V, 4 pole, 250 Amps capacity with sheet steel enclosure fixed on DG Set incl necessary connection of cables from LT panels to change over switch complete all as specified and directed. |
| 191 | Supply and fixing in repair On load change over switch415 V, 4 pole, 125 Amps capacity with sheet steel enclosure fixed on DG Set incl necessary connection of cables from LT panels to change over switch complete all as specified and directed. |
| 192 | Supply and fixing in repair On load change over switch415 V, 4 pole, 100 Amps capacity with sheet steel enclosure fixed on DG Set incl necessary connection of cables from LT panels to change over switch complete all as specified and directed. |
| 193 | Supply and fixing in repair On load change over switch415 V, 4 pole, 63 Amps capacity with sheet steel enclosure fixed on DG Set incl necessary connection of cables from LT panels to change over switch complete all as specified and directed. |
| 194 | Supply& Fixing in replacement of Procomrelay for 400 KVA DG Set complete all as specified and directed. |
| 195 | Supply & Fixing in replacement Procomrelay for 200 /250KVA DG Set complete all as specified and directed. |
| 196 | Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, will etc and locate the fault, rectify, the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminium conductor heavy duty 1100 volts including and testing for any size complete all as specified and directed. (Excavation/earth work & sand cushioning, brick and joint shall be measured & paid for seprately). |
| 197 | Disconnecting & taking out defective underground cable any size and any type from trenches, pole,pipe , floor, will etc. complete all as specified and directed. |
| 198 | Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with cluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc complete all as specified and directed.Note : (i) Earth work, sand, bricks removing , returning filling Aluminium thimbles/lugs will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii)All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. |
| 199 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 25 sqmm. |
| 200 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 35 sqmm. |
| 201 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 50 sqmm. |
| 202 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 70 sqmm. |
| 203 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 95 sqmm. |
| 204 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 120 sqmm. |
| 205 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 150 sqmm. |
| 206 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 185 sqmm. |
| 207 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 240 sqmm. |
| 208 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 300 sqmm. |
| 209 | All as per Srl Item No. 174.00 here in before above but for 3.5 core 400 sqmm. |
| 210 | Excavation in trenches n.exc 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in any type of HT cables/pipes, foundation of poles, locatingfault of LT Cable and stay assembly complete all as specified and directed. |
| 211 | Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25CM thick complete all as specified and directed. |
| 212 | Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed. |
| 213 | Material and Labour for dry sand cushioning to underground cables with 8 CM thick before laying of cables and 15CM thick after laying and stretching of cable complete all as specified and directed. |
| 214 | Supply and fix Bricks common burnt clay building bricks sub class \"B\" complete all as specified and directed. |
| 215 | Dismantling and taking down old u/s earthing and material for earthing complete with galvanized steel earth electrode plate of size 60 x60 x 6 mm thick burind directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of rarth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4 mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, cover 50mm thick RCC 1:2:4 type B-1 using 8mm for steel bars @ 10 cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20 mm bore nedium grade , funnel, wire mesh, also including earth work, common salt, charcol dust complete all as specified and directed. |
| 216 | All as per Srl Item No. 191.00 here in before above but usingGI plate 60×60cm ×3.15mm thick electrode and 32×6 mm GI strip as earthing lead. |
| 217 | Supplying and fixing in replacement oflight gradegalvanised mild steel pipe 100 mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitablemild steel clamps, bolts, nuts and washers complete all as specified and directed. Note:- Excavation & earth work shall be measured and paidfor separately under appropriate item of this schedule. |
| 218 | All as per Srl Item No. 193.00 here in before above but of size 80 mm bore. |
| 219 | All as per Srl Item No. 193.00 here in before above but of size 50 mm bore. |
| 220 | Note:-Amount of credit ofRs. 189238.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail