| 1 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level complete. |
| 2 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in soft/loose soil. |
| 3 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation/ and getting out in hard/dense soil complete all as specified and directed. |
| 4 | Extra for forming fair finishing drain or channels 30 cm inner girth in cement concrete using extra cement including forms, moulds stopped ends etc.complete all as specified and directed. |
| 5 | Extra over stone walling for hammer dressing with maximum depression from straight edge held against the dressed surfacen exc 40 mm granite or trap stone to face beds and joints as specified of random rubble walling uncoursed or brought upto courses complete all specified and directed. |
| 6 | M & L for PCC (1:2:4) type B-1(20 mm graded stone aggregate) mass concrete as indrain wall etc complete. |
| 7 | M&L for 75 mm thick PCC type C-2, 1:3:6 (40mm graded aggregate) as in sub-base, floors and pavings etc complete all as secified and directed. |
| 8 | M&L for cement concrete type D-2, 1:4:8in Cement concrete (40 mm graded aggregate ) in foundations, filling and mass concrete complete all as specified and directed |
| 9 | M&L for Hard core, (broken srone or boulders) broken to gauge exc 63 mm and n exc 100mm complete all as specified and directed. |
| 10 | M&L for joint freeNon - skid Ceramic Coured tiles 7 to8 mm thick area of each tile exceeding0.18 sqm but n.exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cementcomplete. |
| 11 | M&L for keyed pointing to random rubble masonry or brought upto course in cement mortar 1:4 complete all specified and directed. |
| 12 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed |
| 13 | M&L for PCC 100mm thick, type D-2, 1:4:8 (using 40mm graded stone agg) in sub-floors, sub-base, floors and pavings etc. complete all as specified and directed |
| 14 | M&L for PCC 40mm thick, type B-1, 1:2:4 (using 20mm graded stone agg) infloors and pavings etc finished ecen and smooth with using extra cement complete all as specified and directed by engr in charge. |
| 15 | M&L for plain cement concrete 75mm thick type C-2, 1:3:6, (40mm graded stone aggregate) as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement. |
| 16 | M&L for Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections conformimg to Fe -290(Gde E -165) complete all as specified and directed |
| 17 | M&L for Precast PCC bonders (for stone walling) type B-1, 1:2:4 (20mm graded stone agg) in CM 1:6 as in bond stone complete all as specified and directed |
| 18 | M&L for Prepairing surfaces plastered or unplastered newly surfaces with two coats of cement base paint over Primimg coat complete all as specified and directed by engr in charge |
| 19 | M&L for Preparation ofnewlyplastered wall surfaces and applying Two coats of Oil Bound distemper over a coat of primer Complete all as specified and directed by engr in charge |
| 20 | M&L for preparation of newly steel surface of any description, over 10cm in width or girth,not otherwise described with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 21 | M&L for screed bed or bedding layer of 15mm thick in cement mortar 1:4 for laying floor tiles etc all as specified. |
| 22 | M&L for walling of random rubble uncoursed, well bonded,bedded and solidly hearted built in CM 1:6 complete all as pecified and directed |
| 23 | M&L Forming 12mm thick Expansion joints filledwith pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’for 75 mm thick concrete slab. |
| 24 | M&L PCC 1:2:4 typeB-1 using 20mm graded stone aggregate as in coping complete all as specified and directed |
| 25 | M&L rendering 10 mm thick in CM 1:4on concrete outer surfaces finished even and smooth without using extra cement . |
| 26 | M&L rendering 10mm thick in CM 1:6on concrete inner surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 27 | M&L rendering mixed with liquid wpc by 0.4% of cement weight 15mm thick in CM 1:4on concrete outer surfaces finished even and smooth without using extra cement .complete all as specified and directed |
| 28 | Removing excavated material not exc 50 mtrdepositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 29 | Returning filling in incl spreading,levelling, watering and well ramming in layers n.exc 25cm. |
| 30 | Rough excavation n exc.1.5m deep and gatting out in hard/dense soil. Complete all as specified and directed. |
| 31 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete as specified. |
| 32 | S&F of 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls. |
| 33 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed. |
| 34 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed. |
| 35 | Supply only of Liquid water proofing compound for exteenal plastering complete all as specified and directed by engr in charge |
| 36 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out in hard/dense soil. |
| 37 | Use and waste flat form work to vertical faces of drain/retaining wall and similar work . |
| 38 | M/L for point wiring in casing caping with 1.5sq mm FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following:- One light/fan point controlled by one No piano type switch5 Amps single pole one way |
| 39 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on Same board. |
| 40 | One socket outlet 5/3 pin 6 AMPS controlled by one switch onindependent board. |
| 41 | All as per item No 1 above but one 3 pin socket out let 15/16 Ampswith three Nos single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase,neutral & earth continuity conductor. |
| 42 | S&F Switch Piano Flush button single pole one way 5/6 Amp. |
| 43 | S&F Switch Piano Flush button single pole one way 15/16 Amp. |
| 44 | S&F socket outlet 2 in 1,3 pin & 2 pin, 5/6 Amp, 240 volt. |
| 45 | S&F socket outlet 2 in 1 ,3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. |
| 46 | S&F ceiling rose surfacebakelite 65mmx50mm 100watt three terminal. |
| 47 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type. |
| 48 | S&F MCB SPN 40 Amps 240 volts \"C\" series, 10 KA, 50 Hz.Make:- As approved Make of DB |
| 49 | S&F MCB SP 5 to 32 Amps 240 volts \"C\" series, 10 KA, 50 Hz including connection in the DB and testing/commissioning.Make:- As approved Make of DB |
| 50 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 51 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 52 | S&F of 1100 volts grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conductor one twin core cable flat or circular of size 10 Sqmm served with inner sheathing of PVC sheathed in service connections, of size 10 Sqmm 2 core. |
| 53 | Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm diaby means of bolts, nuts, check nuts and washers ofgalvanizediron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC(1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduitgrouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed. |
| 54 | M & L for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for \"LT CABLE 1100 VOLTS\" embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed. |
| 55 | M & L High galvanized mast light 15 mtr height suitable for 8 lanterns symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including earth work and RCC foundation. |
| 56 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 57 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4.0 Core |
| 58 | S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laidin trenches of size 50 mm bore |