| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depthfor foundation, laying of poles in trenches and getting out in hard/dense soil complete all as directed and specified. |
| 2 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed. |
| 3 | Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed. |
| 4 | Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed. Note:- Punned thickness will be measured for payment purpose. |
| 5 | M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed. |
| 6 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 corecomplete all as specified and directed. |
| 7 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 corecomplete all as specified and directed. |
| 8 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 corecomplete all as specified and directed. |
| 9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 corecomplete all as specified and directed. |
| 10 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 corecomplete all as specified and directed. |
| 11 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 corecomplete all as specified and directed. |
| 12 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 corecomplete all as specified and directed. |
| 13 | Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4core XLPE,armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type |
| 14 | Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4core XLPE,armoured, Al conductor cable of size 70 to 95 sqmm,Indoor/Outdoor type |
| 15 | Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4core XLPE,armoured, Al conductor cable of size 120 to 150 sqmm,Indoor/Outdoor type |
| 16 | S&F Hot press moulded SMC Junction box of size 270 mm x 200 mm x 135 mmwith right openable hinged doorwith two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts and includingone MCB SP upto 6A, 10 KA for ON/OFF street light, fixed on pole complete all as specified and directed. |
| 17 | Dismanting of ACSR conductor complete all as specified and directed |
| 18 | Dismanting cross arms of M.S channel or angle sections/insulators etc / insd complete ass all as specified and directed. |
| 19 | Supply and fix panel and its connections and install, testing and commissioning of outdoor LT feeder panel of 500 amps, factory made cubicle type of size 1.5 x 1.5 x 0.45m and 3.15mm thick CRCA sheet outdoor type vermin proof with aluminium bus bar of size 25mm x 10mm, AI strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wirig, acessories are fitted on suitable insulator all housed in suitable busbar chamber and provision and fixing of digital voltmeter, ammeter with built in selector switch, CTs of suitable ratio and pilot indication lamps complete alongwith provision of necessary cable entry / exit boxes for all incoming and outgoing cables with suitable cable glands incl earthwork excavation and PCC foundation etc complete testing and commissioning complete all as specified and directed and consisting the following :-(a)MCCB 315 amps, 415 volt, 50 KA breaking capacity 4 pole - 01 Nos ( as incoming)(b)MCCB 100 amps, 415 volt, 36 KA breaking capacity 4 pole - 01 No( as outgoing)(c)MCCB 63 amps, 415 volt, 36 KA breaking capacity 4 pole - 06 Nos( as outgoing)(d)Timer set of capacity 4KW for security lights alongwith TPN 32 Amps MCB - 01 No.(as outgoing)(e)Three phase panel mounted digital type voltmeter 0-500 volts, selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set(f) Phase indicating lamp LED type for Red, Yellow and Blue - 01 SetNote : (a) All incoming and outgoing cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.(b)The cost shall also be include the breaking of floors / walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the exiting surfaces.(c)The panel shall be fabricated from a reputed firm (CPRI Approved). |
| 20 | Supply and fix panel and its connections and install, testing and commissioning of outdoor LT feeder panel of 400 amps, factory made cubicle type of size 1.5 x 1.5 x 0.45m and 3.15mm thick CRCA sheet outdoor type vermin proof with aluminium bus bar of size 25mm x 10mm, AI strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wirig, acessories are fitted on suitable insulator all housed in suitable busbar chamber and provision and fixing of digital voltmeter, ammeter with built in selector switch, CTs of suitable ratio and pilot indication lamps complete alongwith provision of necessary cable entry / exit boxes for all incoming and outgoing cables with suitable cable glands incl earthwork excavation and PCC foundation etc complete testing and commissioning complete all as specified and directed and consisting the following :-(a)MCCB 250 amps, 415 volt, 50 KA breaking capacity 4 pole - 01 Nos ( as incoming)(c)MCCB 63 amps, 415 volt, 36 KA breaking capacity 4 pole - 06 Nos( as outgoing)(d)Timer set of capacity 4KW for security lights alongwith TPN 32 Amps MCB - 01 No.(as outgoing)(e)Three phase panel mounted digital type voltmeter 0-500 volts, selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set(f) Phase indicating lamp LED type for Red, Yellow and Blue - 01 SetNote : (a) All incoming and outgoing cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.(b)The cost shall also be include the breaking of floors / walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the exiting surfaces.(c)The panel shall be fabricated from a reputed firm (CPRI Approved). |
| 21 | Supply and fix panel and its connections and install, testing and commissioning of outdoor LT feeder panel of 500 amps, factory made cubicle type of size 1.5 x 1.5 x 0.45m and 3.15mm thick CRCA sheet outdoor type vermin proof with aluminium bus bar of size 25mm x 10mm, AI strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wirig, acessories are fitted on suitable insulator all housed in suitable busbar chamber and provision and fixing of digital voltmeter, ammeter with built in selector switch, CTs of suitable ratio and pilot indication lamps complete alongwith provision of necessary cable entry / exit boxes for all incoming and outgoing cables with suitable cable glands incl earthwork excavation and PCC foundation etc complete testing and commissioning complete all as specified and directed and consisting the following :-(b)MCCB 100 amps, 415 volt, 36 KA breaking capacity 4 pole - 01 Nos ( as incoming)(b)MCCB 63 amps, 415 volt, 25 KA breaking capacity 4 pole - 02Nos( as outgoing)(c)Timer set of capacity 2KW for security lights alongwith TPN 32 Amps MCB - 01 No.(as outgoing)(d)Three phase panel mounted digital type voltmeter 0-500 volts, selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set(e) Phase indicating lamp LED type for Red, Yellow and Blue - 01 SetNote : (a) All incoming and outgoing cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.(b)The cost shall also be include the breaking of floors / walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the exiting surfaces.(c)The panel shall be fabricated from a reputed firm (CPRI Approved). |
| 22 | M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32 x 6 mm by means of bolts, nutsand washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected toearth test point including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement@ 140mm c/c both ways, watering funnel with GI pipe 15mm dia medium gradeand protection pipe GI 40 mm dia light grade all as specified and directed. Note: Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. |