| 1 | Excavation in trenches / post holes in Soft/ loose soil not exceeding 1.5 mtrwide and not exceeding 1.5 meter in depth for taking out and laying pipe lines not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottomsurfaces to required level.Complete all as specified and as directed. |
| 2 | Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.Complete all as specified and as directed. |
| 4 | Returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil.Complete all as specified and as directed. |
| 5 | Material and labour for sand cushioning for U/G cable 8 cm before laying the cable and 15cm after laying and stretching the cable Complete all as specified and as directed. |
| 6 | Material and labour for fly ash bricks well burnt old size designation 75laid dry flat for protection of cable .Complete all as specified and as directed. |
| 7 | M & L for PCC M-15 (Nominal mix) Type B-1 using 20mm graded stone aggregate for coping as in benching including weathering slightly rounded, chamfered angles and finishing exposed surfaces even and smooth incl necessary formwork.Complete all as specified and as directed. |
| 8 | Supply, laying and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core complete alls as specified and directed |
| 9 | Supply , Laying , testing and commissioning ofXLPE insulated and PVC Sheathed, galvanized steel strip or wire armoured, heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade of size 35 sqmm 3.5 core.Complete all as specified and as directed. |
| 10 | S & F ofGI pipe light grade galvanizedwith all fittings laid in trenches for cable protection of 50 mm bore.Complete all as specified and as directed. |
| 11 | Material and labour for 40 mm dia galvanized iron tube Medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut, bolt and washers.Complete all as specified and as directed. |
| 12 | Material and labour for 25 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut, bolt and washers.Complete all as specified and as directed. |
| 13 | Boring under road and foot path for inserting 40/50 mm bore GI tubing for drawing UG cable, complete all as per specified and directed. |
| 14 | S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof,TPN4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral415 volts complete all as spd and directed . |
| 15 | S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 2 way Double door enclosure made up of CRCA sheet steel,IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-Charge. |
| 16 | M&L for in replacement of concealed Sub main wiring using two single corePVC insulated cable FRLS 4 sqmm copper conductor multi stranded and 4 sqmm copper conductor insulated cable (FRLS)using as earth wire and drawing into and including PVC conduit complete all as specified and directed .Note- One run of PVC conduit , 03 run of 4 sqmm PVC copper wire measured as oneUnit.Complete all as specified and as directed. |
| 17 | S&F for Sub main wiringwith two run of single core PVC insulated unsheathed cable 1100 volts grade, 1.5 Sqmm size with multistranded copper conductor, FRLSH cable as per IS 694: 2010 drawn in with andincluding PVC casing capping not less than 25 mm ISI marked includingall accessories ofcasing caping including one run ofPVC insulated unsheathed 1.5 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed by EIC. ( 2 x 1.5 sqmm + 1 x 1.5 Sqmm earth wire).Complete all as specified and as directed. |
| 18 | All as per item No - 17.0 here-in-before but of size2.5 Sqmm 3 core for single phase,neutral and earth cable( 2 x 2.5 sqmm + 1 x 2.5 Sqmm earth wire). |
| 19 | All as per item No - 17.0 here-in-before but of size 4.0 Sqmm 3 core for single phase,neutral and earth cable( 2 x 4.0 sqmm + 1 x 4.0 Sqmm earth wire). |
| 20 | S&F Bell push suitable to work on 230 volts AC supply, flush type, 5 amp.Complete all as specified and as directed. |
| 21 | S&F Bell ding dong type electric, AC, 230 volts, single phase.Complete all as specified and as directed. |
| 22 | M&LswitchSocket Combination2 in 1 multipurpose, 3/5 pin Amps5 /15 AmpsflushtypeComplete all as specified and directed . |
| 23 | S&FMCB SPN 32-63 Amps 230 V 10KA,C series suitable for fixing of MCB DB complete all as spd and directed . |
| 24 | Fixing only Inverter of any make and any capacity incl electric connection, circuit breakout, necessary Plug socket with testing on finishing with full satisfaction of Engr-in-Charge. |
| 25 | S&F in replacement of single pole andneutral enclouser with a two pin andearth plug and socketcomplete with one MCB single pole 20 Amps.Complete all as specified and as directed. |
| 26 | All as per ser item No 25here-in-before butMCB triple pole & neutral with enclosure415 volt C curve 10 KA 100 Amps capacity.Complete all as specified and as directed. |
| 27 | All as per ser item No 25 here-in-before butMCBsingle pole 32 Amps 10KA 230 V complete all as specified and directed . |
| 28 | All as per ser item No 25here-in-before but MCB triple pole, 63 Amp 240 voltC curve 10 KA.Complete all as specified and as directed. |
| 29 | Material & labour for cutting of the hard standing/bituminous/ Masti type road of suitable depth and 45cm width for laying of LT cable and making good disturbed surfaces by filling with the existing materials to match with the existing road in all respect complete all as specified and directed.(Note: The tenderer shall verify the layers of road before quoting the rates in consultation with Eng-in-Charge, No claims of the tenderer shall be entertained in this regard at later stage.) |
| 30 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium standard conductor served with and inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mmnominal cross section in service connections complete all as specified and directed. |
| 31 | All as per item No 30 here-in-before but of size 16 Sqmm 3.5 core. |
| 32 | Supply and fixing 8/9 watt warm white LED pyramid rd/sq bollard garden light of size minimum 3 feet, aluminium housing with glare free mushroom shaped diffuser complete with new generation, energy saving, envoronment friendly, long life aesthetically designed aluminium landscape luminaire with fitting of LED bulb holder lamp of warm white light as light source of suitable size complete with all accessories,IP65, LED CCT is 3000 K, bulb of 100 lm/w & bollard/garden light having inbuilt driver with suitable surge protection and making suitable foundation/fixing arrangement on hard standing complete all as specified and directed by Enge-in-Charge. |
| 33 | Supply and fixing digital timer switch with outdoor type weather proof IP66 enclosure/DB, for auto on/off operation of street/garden light, 110-240 V AC having 25 ON/OFF operation complete with all accessories,making suitable fixing arrangement on pole complete all as specified and directed by Enge-in-Charge. |
| 34 | Supply and fixing cable junction boxes, weather proof for outdoor type installation of size 155 mm x 210mm x 92mm complete with electrolytic aluminium bus bar suitable cablesize 4-10 sqmm for single phase and neutral fixed on ebonite insulator and one SPN 6-16 Amp complete all as specified and directed by Engr-in-Charge |
| 35 | Supply and fixing ofBusbar chamber 63 Amp with suitable thickness copper busbars, 4 way, 415 volts, 50 Hz, Wall/floor mounted type including suitable fastners, etc complete all as specified and directed. |
| 36 | M&L for earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with topedge of the plate not less than 1.5m below normal ground level connected to GI earth strip32x6 mm dia up to 7.5 metre from earth pit, protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel , common salt, charcoal dust and connected to panel board by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I includingnecessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete all as specified and directed |
| 37 | M & L for cement concrete type D-2, 1:4:8 mix (using 40 mm graded stone aggregate) in foundation of manholes.Complete all as specified and as directed. |
| 38 | M & L for cement concrete type B-1, 1:2:4 mix (using 20 graded stone aggregate) as in benching including necessary formwork.Complete all as specified and as directed. |
| 39 | Extra for forming fair finished to channel or drain 30 cm inner girth in cement concrete using extra cement including mitred/stopped ends, frames mould etc.Complete all as specified and as directed. |
| 40 | M & L for cement concrete type B-1, 1:2:4 mix (using 20 mm graded stone aggregate) in bed blocks, coping etc; including necessary formwork all as directed. |
| 41 | M&L for Brick work with fly ash bricks, straight orcurved on plan exc 6m mean radius,built in cement mortar 1:6 complete all as specified and directed. |
| 42 | M & L rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 surface finished even and smooth without using extra cement.Complete all as specified and as directed. |
| 43 | S&F MS Framed work (Fe-410) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing.Complete all as specified and as directed. |
| 44 | M&L for preparation of new steel surfaces of any description ,over 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. |