| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | 1:2:4(1 cement:4 M sand:8 graded stone aggregate 40mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:5:10 (1 cement : 5 M sand : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement : 2 coarse sand), including the cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3(1 cement : 1.5 M sand : 3 graded stone aggregate 20 mm nominal size ). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 9 | Foundations, footings, bases for columns |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level |
| 11 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in foundation and plinth in: |
| 13 | Cement mortar 1:6 (1 cement : 6 M sand) |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 15 | Cement mortar 1:6 (1 cement : 6 M sand) |
| 16 | Supplying and Filling in plinth with good earth under floors, including watering, ramming, consolidating and dressingall complete. |
| 17 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 18 | 40 mm thick with 20 mm nominal size stone aggregate |
| 19 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 20 | Two or more coat applied @ 1.67 ltr/ 10 sqm and including priming coat of exterior primer applied @0.90kg/10 sqm. |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 22 | Two or more coats on new work. |
| 23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 24 | Fixed to openings . |
| 25 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 26 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete |
| 27 | 250x10 mm |
| 28 | 100x10 mm |
| 29 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete |
| 30 | 100 mm |
| 31 | Supply & Fixing ofWPC door frame and shutter of Qute or equivalent make with solid door frame extruded with size 75mm x 50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55, and Bulk Density 800 Grms / Cub.Mt.. The frame shall be fixed onto the wall using 8 x 100mm long M.S fastener Screw fitted with polymeric nylon sleeve. A minimum of 4nos screws to be provided for each vertical member.Shutter made of 30mm (+/- 1mm) thick WPC Decora Door which is extruded as a single core door with Lead-Free compound. The door must be completely made by machine, without any post-production fabrication. The Solid WPC board shall have minimum Bulk Density 650 KG/ Cub.Mt. The door is suggested to be hinged to the frame with minimum of 4 inch butt hinges of SS make. |
| 32 | Door size upto 0.90 x 2.10 metre with necessary fittings |
| 33 | Providing and fixing UPVC window frame with sliding shutter ( approved make, design and size )and 4mm thick tinted glass panes, locking arrangements,handles and fixined to the opening with suitable GI fastners etc complete as directed by the Engineer in charge. |
| 34 | With Double track frame |
| 35 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 36 | MS tubes |
| 37 | 12 mm cement plaster of mix :1:6 (1 cement: 6 P sand) |
| 38 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 P sand) |
| 39 | 6 mm cement plaster of mix :1:3 (1 cement: 3 P sand) |
| 40 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.a) In cement mortar |
| 41 | Demolishing Cement concrete/R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 42 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 43 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 44 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 45 | Of area 3 sq. metres and below |
| 46 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 47 | 75 to 80 mm dia pipe. |
| 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 49 | 40 mm nominal outer dia. Pipes. |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work |
| 51 | 40 mm nominal outer dia. Pipes. |
| 52 | Cement plaster of thickness 12 mm to 20 mm including raking out joints, preparing and plastering the surface of the walls with SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 M sand with polymer minimum 2% by wt. of cement used) as per specifications complete, as per directions of Engineer-in-charge. |
| 53 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.47 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 54 | Providing and fixing spout pipes 110mm dia PVC pipe of length upto 0.60m after cutting the walls and making good the same after fixing of PVC pipe all as directed |
| 55 | Providing and fixing 110mm dia PVC end cap with necessary solvent cement all as directed |
| 56 | CREDIT in to contractors account of dismantled materials |
| 57 | Door andwindows |