| 1 | Day to Day Maintenance of Feeder Pillars including allied accessories along with checking of Pump Sets as per Inventory and Terms & Condition attached. |
| 2 | Lifting Out of Sewage Submersible Pump Set from the Existing Bore well up to the required depth along with existing GI Pipes and accessories etc. including disconnecting of GI Pipe & Submersible Cable etc. complete as required. |
| 3 | Lowering and Commissioning of Submersible Pump Set in the Existing Bore well up to the required depth along with Replaced (if required)/Existing GI Pipe & Submersible Cable etc., Clamping (at appropriate distance), Water Proof Jointing of Submersible Cable. Replacement of required nuts, bolts, washers and packing, nipple, reducer, connection, testing etc. complete as required. |
| 4 | Supplying & Replacement of PVC Sheathed, PVC Insulated Copper Conductor Flat Submersible Cable of following size including connection, testing etc. complete as required including rebate for dismantle material.3C x 2.5 sq. mm |
| 5 | Supplying and Replacement of following Control Gear/accessories in the Existing Installation for Electric Panel Board/Feeder Pillar, Motor Starter complete in all respect including connections with appropriate size FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required including rebate for dismantle Fixture.6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity |
| 6 | 6 A to 32 A ratings, TP MCB, “C” curve, 10 KA breaking capacity. |
| 7 | 63 A, FP MCB, “C” curve, 10 KA breaking capacity |
| 8 | 100 A, 30 KA, 4-Pole MCCB |
| 9 | 200 A, 36 KA, 4-Pole MCCB |
| 10 | 3-Phase DOL MK1 Starter suitable up to 7.5 HP Pump Set with Relay Range 13 to 22 Amp. |
| 11 | Thermal Overload MK1 Relay Range 13 to 22 Amp . |
| 12 | Standard Operating Coil (MK1), Coil Voltage (220-440 V). |
| 13 | Single Phase Submersible Pump Controller (MR-G2) up to 3 Hp with Relay Range 13 to 22 Amp, Start Capacitor 275 V, 50 Hz (200/250), Run Capacitor 440 V, 50 Hz MFD (2 x 50), Ammeter & Voltmeter. |
| 14 | 3-Phase Submersible Pump Controller (MU-G10) with Single Phase Preventer up to 10 Hp Pump Set, Relay Range 13 to 21 Amp. |
| 15 | Single Phasing Preventer (VSP2- Auto Reset, 40 Volts Unbalance) mounted on Panel Wall. |
| 16 | Extraction of the Existing Fallen and Stuck Submersible Pump Set, including Submersible Cable, GI Pipe, and all associated components from the Existing Bore well, for the entire depth. |
| 17 | Repairing of the Existing Panel Foundation with brick, cement mortar, and plastering, including the disconnection and reconnection of the Existing Cable, to ensure the proper functioning and safety of the Electrical System etc. complete as required. |
| 18 | Repair and Refurbish the Existing Feeder Pillar, including Replacement of 2 mm thick CRCA (Cold Rolled Carbon Steel) Sheet for front and/or side doors, welding of hinges, gasketted covers, handles, locking arrangements, and Painting (both sides as required) to ensure weatherproofing, and aesthetic finish. |
| 19 | Repairing of Existing Wiremesh Protection Frame, including Supply & Fixing of 8 SWG (Standard Wire Gauge) Mild Steel (MS) Wiremesh a mesh size of 75 mm x 25 mm, mounted on an MS Angle Iron Base Frame of size 35 mm x 35 mm x 5 mm. Works to include cutting, welding, surface preparation, painting, and fabrication of locking arrangement etc. complete as required. |
| 20 | Hire Charges of Cable Fault Locating Machine with Skilled Operator for Underground LV Cable Fault Identification, including all testing equipment, safety precautions etc. as required. |
| 21 | Digging Out of 1 No. Faulty PVC Insulated, PVC Sheathed/XLPE Power Cable Laid Underground including removal of the fault and relaying of the same cable after repair, refilling of the excavated trench and redressing of the site (e.g., restoration of surface levels, leveling), and to compliance with safety standards. |
| 22 | Repairing & Rewinding of Submersible Motors of following capacity including cartage (to & fro), dismantling, rewinding with Class-F copper wire, reassembling, supply & replacement of all damaged parts (mechanical seals, bearings, O-rings, cable gland, etc.), and making good for operation. Works also include Electrical connections, testing, painting, and complete as required for return to serviceability. Up to 2 Hp, 1-Ph/3-Ph Submersible Motors |
| 23 | 3 Hp to 5 Hp, 3-Ph Submersible Motors |
| 24 | 6 Hp to 7.5 Hp, 3-Ph Submersible Motors |
| 25 | Repairing and Rewinding of 3-Phase Mono Block Submersible Pump Set of following capacity including cartage (to & fro), dismantling, reassembling, supplying and replacement of all damaged parts (bearing, bush, seals, etc.) of Pump Set, and making good for operation. Works also include Electrical connections, testing, painting, and complete as required for return to serviceability.5 Hp to 7.5 Hp |
| 26 | Repairing of Submersible Pump Set of the following Stages & dia. including cartage (to & fro), dismantling, reassembling, supply & replacement/repairing of all damaged parts of Pump Set, and making good for operation i/c testing, painting etc. complete as required.4\"dia. Submersible Pump Set up to all Stages |
| 27 | 6\"dia. Submersible Pump Set up to 5 Stages |
| 28 | 6\"dia. Submersible Pump Set from 6 to 8 Stages |
| 29 | Supplying and Replacement of following size Double Flanged of \"B\" Class GI Pipe conforming to IS:1239 including welding and all fittings (elbows, tees, flanges, reducers/tapers), nuts, bolts, gaskets, painting and accessories etc. complete as required including rebate for dismantle material.40 mm dia. |
| 30 | 50 mm dia. |
| 31 | 65 mm dia. |
| 32 | Supplying and making straight through joint with Heat Shrinkable Kit including ferrules and other jointing materials for following size of PVC Insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV grade as required.4C x 25 sq. mm |
| 33 | 4C x 50 sq. mm |
| 34 | Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required including rebate for dismantle material.4C x 25 sq. mm |
| 35 | 4C x 50 sq. mm |
| 36 | Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.Up to 35 sq. mm |
| 37 | Above 35 sq. mm and up to 95 sq. mm |
| 38 | Laying of one number PVC insulated and PVC sheathed/XLPE Power Cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.Up to 35 sq. mm |
| 39 | Above 35 sq. mm and up to 95 sq. mm |
| 40 | Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required. |
| 41 | Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia. (OD-63 mm & ID-51 mm nominal) |
| 42 | Supplying and Replacement of Sewage Treated Water Submersible Pump Set, duly coupled with suitable rating 3-Phase, 220-415 Volts, 50 Hz, 3000 RPM Submersible Motor, including Providing and Fixing of 6 meter long GI Chain of suitable strength for lifting the Pump Set from the UGR/Chamber/Pit etc. complete as required including rebate for dismantle Pump Set. The Pump Set shall be suitable for the following duties:a) Capacity: 3 Hp/2.2 KW (minimum)b) Discharge: 640-1000 LPMc) Head Range: 10-18 Meter or 33-59 ftd) Solid Handling Capacity: 35 mme) Outlet Pipe Size: 50 mmf) Suitable Size Cable: 10 Meter (minimum) |
| 43 | Supplying and Replacement of Submersible Pump Set (Water Filled Motor)-4W Series suitable for operation on 3-Phase, 220-415 Volts, 50 Hz AC supply of following specifications:a) Head Range: 11-50 Meter or 37-164 ftb) Discharge Range: 140-330 LPMc) Capacity: 5 Hp/3.7 KWd) No. of Stages: 12e) Outlet Pipe Size: 50 mmf) Suitable Size Cable: 10 Meter (minimum)g) Capacitor Run: 50 μF (minimum)h) Capacitor Start: 120/150 μF (minimum)The work shall also include Lifting and dismantling of existing Submersible Pump Set, Lowering and installation of new pump set in the existing bore well up to the required depth with existing GI pipes and Submersible Cable, Water-proof jointing of Submersible Cable,Replacement of necessary accessories (nuts, bolts, washers, packing, nipple, reducer, connections, etc.) and testing, commissioning etc. complete as required including rebate for dismantle Pump Set. |
| 44 | Supplying and Replacement of Submersible Pump Set (Water Filled Motor)-150 mm (V6) Motor & 150 mm (V6) Pump-SS Head suitable for operation on 3-Phase, 220-415 Volts, 50 Hz AC supply of following specifications:a) Head Range: 52-112 Meterb) Discharge Range: 80-220 LPMc) Capacity: 5 Hp/3.7 KWd) No. of Stages: 8e) Outlet Pipe Size: 50 mmf) Suitable Size Cable: 10 Meter (minimum)g) Capacitor Run: 50 μF (minimum)h) Capacitor Start: 120/150 μF (minimum)The work shall also include Lifting and dismantling of existing Submersible Pump Set, Lowering and installation of new pump set in the existing bore well up to the required depth with existing GI pipes and Submersible Cable, Water-proof jointing of Submersible Cable,Replacement of necessary accessories (nuts, bolts, washers, packing, nipple, reducer, connections, etc.) and testing, commissioning etc. complete as required including rebate for dismantle Pump Set. |
| 45 | Supplying and Fixing of SS Enclosure for 3P/4P MCCB suitable to accommodate up to 3.5C x 70 sq. mm Aluminium Armoured Cable along with In-built Neutral Link for TPN System, IK08, IP-30 Protection, Space for Cable termination, Louvers for better heat dissipation, mounting holes for wall mounting i/c connection, testing etc. complete as required. |
| 46 | Providing and Fixing MV Danger Notice Plate of 200 mm x 150 mm, made of Mild Steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single Red colour on front side as required. |
| 47 | Supplying and Replacement of floor mounted LT Feeder Pillar cubical type double door of size 1000 (H) mm x 900 mm (W) x 300 mm (D) with general arrangement made out of 2 mm thick MS CRCA Sheet having hinged gasket covers and screwed knobs with double locking arrangement & Locking Hooks and separate Rain Protection Cover with extension of 100 mm in Width & Depth, supported with MS Angle Iron legs and bottom frame of size 40 mm x 40 mm x 6 mm x 1 mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs (around 25% of length) should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, Painting with Primer, Numbering, Identification Plate of Component embossed and/or printed in Metalincluding Supply & Fixing of following accessories etc. complete as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle Feeder Pillar.a) 125 A, 36 kA Ics=100% Icu and Operational Voltage 690 V, 4 Pole MCCB- 1 No. (Incomer).b) 3-Phase Submersible Pump Controller (MU-G10) with Single Phase Preventer up to 10 Hp Pump Set, Relay Range 13 to 21 Amp- 1 Set.c) Ammeter (0-100 A) 96 sq. mm in size and 100/5 CT’s Ratio- 1 Set.d) Voltmeter (0-500 V) 96 sq. mm in size with Selector Switch- 1 Set.e) Indication Lamp (RYB) with Control HRC Fuse with Fuse Fitting- 1 Set.f) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 1 No.g) 6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity- 2 Nos.h) 150 A, 4-Strip Al. Bus-Bar of minimum 400 mm long and of size 30 mm x 5 mm with sleeve and nut-bolts- 1 Set.i) 200 mm x 150 mm MV Danger Notice Plate of 2 mm thickness- 1 No.j) Earthing Stud- 2 Nos.k) Lifting hook on the top of feeder pillar- 1 Set. l) Lamp Holder inside Feeder Pillar- 1 No.m) 4 Way Neutral Link- 2 Nos. |
| 48 | Supplying and Replacement of floor mounted LT Feeder Pillar cubical type double door of size 1000 (H) mm x 900 mm (W) x 300 mm (D) with general arrangement made out of 2 mm thick MS CRCA Sheet having hinged gasket covers and screwed knobs with double locking arrangement & Locking Hooks and separate Rain Protection Cover with extension of 100 mm in Width & Depth, supported with MS Angle Iron legs and bottom frame of size 40 mm x 40 mm x 6 mm x 1 mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs (around 25% of length) should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, Painting with Primer, Numbering, Identification Plate of Component embossed and/or printed in Metal including Supply & Fixing of following accessories etc. complete as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle Feeder Pillar.a) 200 A, 36 kA Ics=100% Icu and Operational Voltage 690 V, 4 Pole MCCB- 1 No. (Incomer).b) Ammeter (0-100 A) 96 sq. mm in size and 100/5 CT’s Ratio- 1 Set.c) Voltmeter (0-500 V) 96 sq. mm in size with Selector Switch- 1 Set.d) Indication Lamp (RYB) with Control HRC Fuse with Fuse Fitting- 1 Set.f) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 1 No.g) 6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity- 1 Nos.h) 63 A, FP MCB, “C” curve, 10 KA breaking capacity- 3 No.i) 200 A, 4-Strip Al. Bus-Bar of minimum 400 mm long and of size 30 mm x 5 mm with sleeve and nut-bolts- 1 Set.j) 200 mm x 150 mm MV Danger Notice Plate of 2 mm thickness- 1 No.k) Earthing Stud- 2 Nos.l) Lifting hook on the top of feeder pillar- 1 Set. m) Lamp Holder inside Feeder Pillar- 1 No.n) 4 Way Neutral Link- 2 Nos. |
| 49 | Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 50 | Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required. |