| 1 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings such as switches,ceiling roses, pendants, regulators, sockets, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 2 | Taking down submain wiring of any description and any type/size. |
| 3 | Taking down copper/aluminium earth strip of any size/type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, or roof etc. |
| 4 | Taking down MCB distribution board of any rating/type/size or other descriptions. |
| 5 | Taking down MCBs/MCCBs of any rating/type/size or other descriptions. |
| 6 | Taking down GI pipe of any dia including fittings etc. |
| 7 | Supply and fixing Aluminium strop 25x3.15mm with saddles and fixing screws for roof conductors and down conductors above ground. |
| 8 | Supply and air termination rod single pointed Aluminum rod 12mm dia 300mm long. |
| 9 | M&L test point terminal block made of Gun metal or phosphorous bronze size 75x75x25mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal screws complete. |
| 10 | M&L tube medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid on floors of dia 40mm. |
| 11 | M&L porcelain insulator including fixing with 4 Nos nuts, bolts and washers on roof top. |
| 12 | Providing cement concrete in roof kerbs or mud stops, rounded or chamferted on edge type B1 1:2:4, (20mm graded aggreggate). |
| 13 | M&L earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to GI strip 25x4 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised strip and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates. |
| 14 | M & Learthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burrieddirectly in groundverticallyto a depth not less than 2.25 metrebelowgroundlevelwith topedgeof theearth plate at a depth not less than 1.5 mtr belowgroundlevelearth platesurrounded from all sides by 15 cmthickpacked connectionby usingearth leadGIeathwire 4.0 mm size by meansof bolts, nuts, check nutsand washersmade of galvanised ironand thimbles and other endof theearth wire connectedto mainswitch board/panel board protected by galvanised iron light grade pipe 15mm bore minimum upto 7.5 mtr length fixedin wall/floor/andGI Pipe 20mm borelight grade forwatering with wiremesh funnel and PCC chamber in cementconcrete 1:3:6 typeC-2 and RCC pitcover of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways including handle made out of 20mm dia bars, includingnecessaryexcavation andearth work in anytype ofsoil, returningsoil and disposed of surplussoilto adistancenotexceeding 50 Mtraway all as shown inelectrical PlateNo 3ofSSR 2009( Part-I) all as specified and directed. |
| 15 | M&L for earth electrode 17.2mm dia 3 mtr long of low Carbon steel electrode with copper bonding of thickness 250 micron, back-fill earthing enhancing compound AXIS ULTRA/AXIFILL type Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per clause 14.5D of IEEE:80 standard. Back-fill compound should be electronically conductive (like in Metals) and should not depend on moisture for conduction. Back-fill compound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach/diffuse into the ground.Back-fill compound shall not be mixed with any type of soil while pouring in the bore hole.Test certificate as per IEC:62561-7 for back-fill compound shall be submitted alongwith the material including SS clamps and PVC earth pit 300x300mm with plastic lid to be provided both sides,complete all as specified. NOTE: (i) Earth electrode should be as per standards of IS:3043, IEC 62561-2 and IEC: 60364-5 and made of high tensile rod copper bounded, high tensile strength good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 mtrs.(ii) Back-fill compound should be compliance to the standards IEEE:80, IS:3043, BS 7430, IEC 62561-7, ANSI/NSF 60 certification. (iii) Provide positive low resistance electrical connections to the earth.(iv) Does not contain hazardous chemicals. (v) Electronically conductive (Like in metals) and sholud not depend on moisture. (vi) Provide the desired value of earth resistance as per required specified value.(vii) Provide the Exothermic welding joints to entire grid system of earthing electrode. (viii) Test certificate to be provided for each electrode separately. |
| 16 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron. |
| 17 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip. |
| 18 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip. |
| 19 | Supply and fixMCB DB SPN 8 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete. |
| 20 | Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link completeall as directed by Engineer -in- Charge. |
| 21 | M&L sheet metal enclosure for DBs when MCBs to be used triple pole and neutral double door with 200 amps rated bus bar 4 ways complete. |
| 22 | Supply and fixing in replacement 415V, 10KA \"B\" curve miniature circuit breaker (MCB) of three pole and neutral and current carrying capacity 16 to 32 amps complete with connection testing and commissioning. |
| 23 | Supply and fixing in replacement miniature circuit breaker (MCB) of single pole and neutral and current carrying capacity 40 amps 240V 10KA\"C\" curve testing and commissioning. |
| 24 | Supply and fixing in replacement 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 25 | Supply and fix in replacement MCCB 125 Amps, FP 415 volts 25 16KA, 4 pole 50 HZ with thermal magnetic setting includingcomplete all as specified and directed. |
| 26 | Supply and fix in replacement MCCB 160 Amps, FP 415 volts 25 16KA, 4 pole 50 HZ with thermal magnetic setting includingcomplete all as specified and directed. |
| 27 | S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 28 | S&F in repair Sub main wiring with two runs of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 29 | Supply and fixing in replacemen LED street light fitting 60 watt 230 volts AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp, bracket with im,pact and corrosion resistant including thermal management in multiple optics having IP 66 protection. |
| 30 | GI bracket 40mm bend to shape including clamps,nuts, bolts and washers and grouting in wall and painting with two coats of black enamelled paint over a coat of red oxide primer and making electrical connection with three core copper cable of suitable size all as specified. (Note: Copper cable shall be measured and paid separetely). |
| 31 | M&Lcopper three core cable 1.5 sqmm PVC insulated 1100 volts grade for connecting street light with connector all as directed. |
| 32 | Taking down of old unsv garden/gate light fittings of any description including service connection/wiresof any dia or size and accessories etc complete. |
| 33 | Supply and fixing and connecting LED post top light die cast aluminium housing spigot, powder coated top cover milky/opal diffuser, spun cover die cast, pole/pillar mounted 100Lm/w having IP-65 protection complete of 40 watt including making necessary electrical connections with suitable size copper cable 1100 volt grade all as directed. |
| 34 | Supply and fixing and connecting LED bollard light die cast aluminium housing spigot, powder coated top cover milky/opal diffuser, pyramid shape, 100Lm/w having IP-54 protection complete of 12 watt including excavation, earth work andincluding making foundation for bollard light of suitable size in cement mortar of suitable ratio and plastering & painting the surfaces of foundation complete all as specified.Note: height of foundation of light shall be made as per the direction of Engr-in-Charge and it should also be made minimum 0.30 mtr below ground level extra above of ground level foundation.and making necessary electrical connections all as directed. |
| 35 | Supply laying or fixing jointing and testing LT under ground electric power cable crossed linkedpolyethylene (XLPE) insulated, two or more core, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of following sizes complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles / in ducts /in GI pipes etc. (Excavation, earth work, sand cushioning, protection bricks/tiles/block, clamps, nuts, bolts, washers and pipe shall be measured and paid separately under appropriate items) 10 sq mm cross sectional area, 2 core complete all a specified and directed. |
| 36 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified. |
| 37 | Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubingof 40 to 80 mm bore complete all as specified. |
| 38 | Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified. |
| 39 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified. |
| 40 | Material and labour for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed. |
| 41 | M&L laying well burnt old size bricks, sub calss \"B\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all as specified. |
| 42 | Supplying and fixing (in repairs) Galvanised mild steel tubing, \"Light grade\" of following bore complete with all fittings, laid in trenches/ under roads, drain, paths, fixed to poles/walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately) |
| 43 | 40 mm bore |
| 44 | 50 mm bore |
| 45 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn throughrigid PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box/M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate,top sheet cover for housing switches,socket out let and fan regulators etc, all as specified and as directed for the followings:- |
| 46 | Onelight/fan or bell point controlled by oneway switch with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 47 | Onelight point controlled by two-way switches with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 48 | One 3 pin 5 Amps socket outlet point controlled by one switch on same board with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 49 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 50 | All as item No-43 above but with cable 2.5 sqmm copper cable PVC insulated FRLS complete. |
| 51 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 52 | M&L in replacementswitch Modular type 6 Amps 2 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 53 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 54 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 55 | M&L in replacement modular stepped type fanregulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 56 | M&L in replacement bell electric (ding dong) 230 volt, SPall complete all as specified and directed by Engineer in charge . |
| 57 | M&L in replacement Modular Bell pushbutton SP, 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 58 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge . |
| 59 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor >0.90, THD< 10%, colour temperature-6500K, surge protection 2.5 KV in CM, IP-20 protected, Class-1,short circuit and over circuit protection, voltage range-180 to 270 Volts AC, temperature range 0 to 45 Degree C minimum andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 60 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained, CRI >70, power factor > 0.90, THD < 10%, color temperature >6500 K , surge protection 2.5 KV in CM IP- 20 protected,voltage range - 180 to 270 volts AC, temperature range 0 to 45 Degree C minimum, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 61 | S&F LED 2X2 feet backelite surface mounted fitting 36/40 Wattsnot less than 3600lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 100 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.9, THD<10%, 25000 burning hours ,Ambient temperature 0 to 50 Deg C, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. |
| 62 | M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge. |
| 63 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.90, driver with Voltage range 180-270V, Temperature range 0 to 45 Deg minimum, Driver efficiency >85%, THD<10%, CRI>70, Color Temperature-6000K, surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5 sqmmcopper conductor flexible wire completeallas specified and directed. |
| 64 | Schedule of Credit |