| 1 | The following precautionary measuresshall be ensured by the contractor before and during execution of the work :- (a) The tenderer is instructed to keep in mind while quoting their rates that all the painting procedure to be followed under the scope of work.(b) Contractor shall deposit entire quantity of material in two phases (i.e. 50% in EACH phase) in sealed containers required for painting works covered in this contract under the custody of Engineer-In-Charge/ Office in charge of unit.(c) The materials as required shall be issued to contractor by JE/ Engineer-In-Charge on daily basis and the empty containers/ bags shall be deposited in the store of Engineer -In-Charge by the contractor, for verification as per standard consumption/ coverage prescribed by the manufacturers.(d) After completion of painting work contractor shall remove and clean all the droplets/stain of paint left on the floor, glasses & joinery using professional equipment’s and disinfect complete room as instructed by Engineer-In-Charge. The cost of the same is deemed to be included in tenderer\"s quoted rates.(e) Recovery @ cost of material shall be done from contractor if any material found lying on site after completion of work as per manufacturer\"s instruction and quality satisfaction of Engineer-In-Charge. (f) The work shall be executed upto 15 mtr height and cost of suitable scaffolding shall be deemed to be included in quoted rates by the tenderer. (g) OEM for this work will only be branded material manufacturing company i.e. Asian / Berger / Nerolac and all materials of similar make as approved by GE. |
| 2 | M&L for preparation of old decorated surfaces of wall including brooming, scraping down, smoke spot, moss, efflorescent salts, trading oil, grasy spotsand stopping nails marksand one coat of white wash on walls complete all as specified and directed. |
| 3 | M&L complete removalof old decorated surface of wall and applying two coats of oil emulsion distemper white/coloured over one coat of white cement based putty (where it is required) all as specified and directed. Note : putty shall be measured and paid seperately. |
| 4 | M&L for preparation of old decorated surfaces of wall including brooming , scraping down, smoke spot, moss, efflorescent salts, trading oil, grasy spotsand stopping nails marks andone coat of oil emulsion distemper all as specified and directed. |
| 5 | M&L for preparation of old decorated surface of wall including brooming, down, scrapping down smoke spot and stopping nails mark by filling white cement putty and applying one coat of coloured cement based paint all as specified. |
| 6 | All as per item No. 4.00 here-in-bfore but on ceilings. |
| 7 | M&L for preparing old plastered or unplastered surfaces of walls, removing unnecessary nails including filling of cracks/holes by crack filler and applying two coats cement based paint complete all as specified and directed. |
| 8 | M&L for preparation of old painted surfaces of wood/wood based materials exc 10cm width or girth and applying one coat of synthetic enamel paint as directed and specified. |
| 9 | All as per item No. 7.00 here-in-bfore but on steel surfaces. |
| 10 | M&L complete removalof old decorated surface of wall and applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm white/coloured over and all as specified and directed. |
| 11 | M&L for prepration of plastered or unplastered old surfaces of walls, removing unnecessary nails including filling of cracks/holes by crack filler and applying one coats of 100% Premium acrylic emulsion painthaving VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.00 litre/ 10 sqm, complete all as specified and as directed. |
| 12 | M&L complete removalof old decorated surface of wall and applying twocoat of interior plastic emulsion paintwhite/coloured over one coat of white cement based putty (where it is required) all as specified and directed. |
| 13 | M&L for preparation of old decorated surface of wall including brooming, down, scrapping down smoke spot and stopping nails mark by filling by birla putty and applying one coat of interior plastic imulsion paintwhite/coloured all as specified. |
| 14 | M&L for two or mor coats of french polishing on surfaces of any descriptionwidth or girth including cleaning and preparing the surface including a coat of wood filler on old surface with one or more coats all as specified and directed. |
| 15 | M&L one coat white putty on walls/ceiling all as specified and directed |
| 16 | Taking down plants/vegetable growth, etc (upto 10cm girth), from buildings walls, parapets by cutting/chiseling fully without disturbing structure upto height of 10.00m from average ground level at different locations and cleaning the surfaces neatly with wire brush to remove dust and other foreign particles and applying hydorochloric acid (HCL) on left over root portion and making good the disturbed surfaces in cement mortar 1:4 complete all as specified and as directed. |
| 17 | M&L for rendering 10 mm thick cement mortar on brick/stone surfaces or surfaces other than fair faces of brick work in cement mortar 1:6, even and smooth finish without using extra cement, in patches including taking down cement plaster any description on brick/stone walls complete all as specified and directed |
| 18 | M&L for 5 mm thick rendering in CM 1:3 on fair face of brick/ concrete surfacesas in ceiling including taking down cement plaster any description on brick/stone walls complete all as aspecified and dirceted |
| 19 | M&L 15mm thick rendering in two layers (10mm+5mm ) CM 1:4 on fair faces of brick/concrete surfaces finished even and smooth w/o using extra cement. Including taking down cement plaster any desccription on brick/stone walls complete all as specified. |
| 20 | M&L for preparation of newly plastered surface of wall andand applying two coat of oil emulsion distemper white/coloured overone coat of white cement based putty (where it is required) all as specified and directed. Note:- Putty shall be measured and paid seperately. |
| 21 | M&L for preparation of newly plastered surface of wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. |
| 22 | M&L for preparation of newlyplastered surface of ceiling and applying three coat of white wash complete all as specified and directed. |
| 23 | M&L for crack filling with approved crack filling compound (Crack seal of M/s Asian Paint or equivalentin Pidilite), crack thickness more than 3 mm including opening of cracks, cleaning, and necessary scaffolding suitable for height upto 10.00 mtr from ground level complete all as specified and as directed. |
| 24 | Hacking out old broken glass (any thickness quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as specified and directed. |
| 25 | S&F 3 mm thick, plain sheet glass ordinary quality nexc 0.50 Sqm in each pane all as specified and directed. |
| 26 | S&F 4.0 mm thick, plain sheet glass ordinary quality nexc 0.50Sqm in each pane all as specified and directed. |
| 27 | S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed to frames all as specified and directed. |
| 28 | M&L for preparation of old concretesurfaces of any description over 10 cm in width or girth and applying onecoat of synthetic enamel paint on concrete surfaces complete all as specified and directed. |
| 29 | M&L for providing precast cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregates) louvres and jallies, 25mm thick (measured solid) all mouldings but excluding frame including demolition of old precast/ stone jallies fixed in any mortar and pattern all as specified and directed |
| 30 | M&Lfor providing precast cement concrete type B1 1:2:4 (using 20mm graded stone aggregates) asin decorative moulded columns, posts, boundary pillars, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM 1:4 complete with joints to match the exisiting all as specified and directed. |
| 31 | Supply only integral water proofing compoundas as specified and directed. |
| 32 | M&L RCC 1:1.5:3 , type A-1, nominalmix (using 20mm graded stone aggregate)as in plinth beams,lintel, lintel band and gable beams etcincluding formwork complete all as specified and as directed. |
| 33 | M&L for TMT steel bars, 10 mm dia and over, as in reinforcement for concrete, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm all as specified and directed. |
| 34 | S&F in repairs 110mm bore, PVC (SWR), bend any radius complete all as specified and directed. |
| 35 | S&F in repair 75mm bore, PVC (SWR), bend any radiuscomplete all as specified and directed. |
| 36 | S&F in repair 110mm bore, PVC (SWR), bend any radiusprovided with access door complete all as specified and directed. |
| 37 | S&F in repair 75mm bore, PVC (SWR), bend any radiusprovided with access door complete all as specified and directed. |
| 38 | S& F in repair 110 mm bore, PVC (SWR) Junction single (single T) equal or unequal with access door complete all as specified and as directed. |
| 39 | S& F in repair 75 mm bore, PVC (SWR) Junction single (single T) equal or unequal with access door complete all as specified and as directed. |
| 40 | S&F in repair 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and as directed. |
| 41 | S&F in repair 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and as directed. |
| 42 | M&L for writing letter or figures with any type of paint (Block, Roman, Italic or Indian) n exec 30 cm high all as specified and directed. |
| 43 | M&L for writing stops, commas, short lines, dashes, hyphens, brackets etc all as specified and directed.Note : Painting with two coats of SEP in circular shape behind the letter writing, stops, commas, short lines, dashes, hyphens, brackets shall be deemed to be included in the quoted rates) |
| 44 | Deduct Schedule of credit (calculation will be done off line) Rs. 600.00 |