| 1 | S&F structural steel work in tubular trusses & purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 2 | S&F Mild steel work as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed. |
| 4 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out complete all as specified and directed. |
| 6 | M&L for plain cement concrete, 1:4:8 type D-2 in foundations, filling and mass concrete complete all as specified and as directed. |
| 7 | M&L for plain cement concrete, 1:3:6 type C-2 in foundations, filling and mass concrete complete all as specified and as directed. |
| 8 | M&L for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 9 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 10 | M&L for 15mm thick plastering on fair faces of brick work or concrete surfaces in CM (1:4) complete surface finished even and smooth without using extra cement) complete all as specified and directed. |
| 11 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 12 | M&L for 10mm thick designer Vitrified ceramic tiles (square/rectangular) area of each tile notexceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of 15mm thickin CM (1:4) for laying floor finishes completeall as specified and directed. |
| 13 | M&L for preparing newly plastered surfaces of wall and applying two coats ofcement base paint over a coat of cement primer complete all as specified and directed. |
| 14 | S&F MS Plates/sheet (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including welding etc for Fe-410-W(GdeE-250) qualityB complete all as specified and directed. |
| 15 | M&L for cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required for superficial area Exc. 150 sq. cm but n exc 400sq. cm complete all as specified and directed. |
| 16 | M&L for plain cement concrete, 1:3:6 type C-2 as in pillars, boundary pillars and posts or similar work (including caps and bases) complete all as specified and as directed. |
| 17 | S&F Mild steel screw bolts (machine made) for hold fast, length of bolt exc 5cm but n exc 10cm long, diameter of neck5 to 10mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut and making good by cement mortar 1:3 or as required complete all as specified and as directed. |
| 18 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 19 | S&F Welded steel wire fabricweight n exc 4 Kg/sqm complete to wood or steel members complete all as specified and as directed. |
| 20 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil complete all as specified and directed. |
| 21 | M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick CM 1:6 cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 22 | M&L for rubbing and polishing to existing kota stone flooring complete all as specified and directed. |
| 23 | Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting pointcomplete all as specified and directed . |
| 24 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 25 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size Outer dia 63 mm and inner dia 50 mm of pipewith all fittings laid in trenches / road/ nallah or fixed along wall/ poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified.(Excavation and earth work shall be measured and paid separately). |
| 26 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 27 | Supply and spreading fine aggregate (sand) for sand cusioning to receive interlocking tile complete all as specified and directed all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for refixing machine pressed precastcoloured Interlocking paver block / tiles any shape and size60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directedby Engineer-in-Charge. |
| 29 | M&L machine pressed precastcoloured Interlocking paver block / tiles any shape and size60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed all as specified and directed by Engineer-in-Charge. |
| 30 | S&F/Laying, connecting and testing of XLPE insulated screened PVC badded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade as per IS 7098 with stranded aluminium conductor of 70 Sqmm, 3½ core size complete all as specified and directed. |
| 31 | S&F wall mounted fan, 400 mm sweep, 230 Volts, 50 Hz, single phase complete all as specified and directed. |
| 32 | Material and labour for point wiring for fan point controlled by one way switch with using 1.5 Sqmm (nominal area) stranded copper conductor, FR single core, PVC insulated & unsheathed cable, 1100 volts grade in non metallic rigid PVC oval conduit/PVC casing caping (Medium grade) of suitable size not less then 20 mm dia including necessary accessories like bends, tees, elbow etc fixed on wall/ceiling all as directed with using new sunken type pressed steel box/terminal boxes of suitable size concealed in wall covered with modular plate for mounting fittings wiring accessories i.e. switch/socket etc andusing 1.5 Sqmm (nominal area) stranded copper conductor FR single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly with cadmium plated machine screws complete all as specified and directed. |