| 1 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge |
| 2 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 4 | Cutting the existing road of any kind straight by manual, depth and width not less than 30 cm for pipes up to 150 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipesand filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed. |
| 5 | M&L for road crossing/ drain crossing by adopting trench less tunnelling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunnelling, excavation in any type of soils including hard rock, TO CROSS WATER PIPE LINE UP TO 200 mm dia in any length including jointing materials and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed INCLUDING MAKING GOOD OF DISTURBED SURFACE.NOTE: Pipe will be measured and paid separately under relevant items. |
| 6 | M&L for PCC(1:2:4) type B1 using 20 mm graded stone aggaregate in kerbs/coping /bed plates and like including weathering slightly rounded or chamfered completewith necessary use and waste fo formwork complete all as specified and directed at site. |
| 7 | M&L for PCC(1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and fillingincluding weathering slightly rounded or chamfered completewith necessary use and waste fo formwork complete all as specified and directed at site. |
| 8 | Taking up cast iron water mains including all fittings with spigot and socket ends and lead joint including burning out lead joint and e of following sizes. |
| 9 | 80 mm Bore |
| 10 | 100 mm Bore |
| 11 | 150 mm Bore |
| 12 | S&F in replacement ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/ 2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/ 2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/ DI/ MS pipe line of any size up to 350 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Quoted rates inclusive of Push on Joints / D-Joints as required (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(c) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution. |
| 13 | 80 mm Bore |
| 14 | 100 mm Bore |
| 15 | 150 mm Bore |
| 16 | Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI / DI specials, Joints and Earth work shall be measured and paid separately under relevant items of this schedule. |
| 17 | 80 mm Dia |
| 18 | 100 mm Dia |
| 19 | 150 mm Dia |
| 20 | S&F CI / DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single \"Y\" branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed. |
| 21 | Burning out lead joint in positionincluding removing old lead to store, etc. for following sizes of CI pipe removing old lead complete all as specified and directed :- |
| 22 | 80 mm Dia |
| 23 | 100 mm Dia |
| 24 | 150 mm Dia |
| 25 | M&L for run lead joint for CI pipe/ DI pipe including spun yarn etc for spigot and socket pipes and fittings complete all as specified and directed for the following bore of pipes:- |
| 26 | 80 mm Dia |
| 27 | 100 mm Dia |
| 28 | 150 mm Dia |
| 29 | S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL , ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/ CI/ DI/ GI / PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) Quoted rate inclusive of cutting of any kind of pipes and all ITEMS as required for fixing and proper functioning of Joints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account. |
| 30 | 80 mm Dia |
| 31 | 100 mm Dia |
| 32 | 150 mm Dia |
| 33 | S&F in replacement of unserviceable DI non raising type sluice valve both ends flanged/socket type with DI body, ISI marked, IS 14846, pressure PN 1.6 with SS spindle with clamps and check nuts, operating hand wheel complete all as specified and directed for the following sizes:- |
| 34 | 80 mm bore. |
| 35 | 100 mm bore. |
| 36 | 150 mm bore |
| 37 | S&F, in replacement connecting and testing in repair of Cast Iron foot Valves flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed. |
| 38 | 50 mm Dia |
| 39 | 80 mm Dia |
| 40 | Construction of valve pit ofsizes 100cmx100cmx100cm (internal dimentions),any type soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, 100mm thick PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4), rendering, 12 mm thick cement mortar (1:4) internally, finished even and fair & pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint including dismantling old unsv valve pit, complete all as specified. |
| 41 | Construction of valve pit ofsizes 60cmx60cmx60cm (internal dimentions),any type soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, 100mm thick PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4), rendering, 12 mm thick cement mortar (1:4) internally, finished even and fair & pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint including dismantling old unsv valve pit, complete all as specified. |
| 42 | Attending complaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION (MARRIED / OTM/ single / multi story building), IDENTIFY THE FAULTS including rectification by taking down of existing GI/ PPR tubing up to 80 mm bore, cutting/ threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/ sockets/ nipples etc as required at site to RESTORE WATER SUPPLY complete all as specified and directed.Notes:-(i) The contractor will be allotted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays.(ii) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution. (iii) Spares/ GI fittings required to be replaced and shall be measured and paid separately under respective items. |
| 43 | Rectification of leakages in pumping / delivery lines(CI/ DI/ PPR/ MS) of size 80 mm to 200 mm at Military area / Military Roads / civil Roads / PWD Roads / Cantt board roads by taking necessary permission from respective authorities by excavating PCC/ RCC/ pavement/ soft & hard soil/ rock of any depth by using necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail pieces, any type of gasket , welding work etc as required to arrest the leakages completely and making joints, filling the trenches , site clearances and PCC at the top portion as required complete all as specified and as directed. Note:-(i)CI specials, lead Joints, D-Joints, Clamp joints, upto 10 kg deemed to be included in quoted. (ii) Excavation and PCC will be measured and paid separately under relevant items.(iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.(iv) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.(v) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(vi) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution. |
| 44 | Taking up or down steel tubing and connections, from trench or wall/floor including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :-Note : (a) Excavation and Earth work shall be measured and paid separately. |
| 45 | 15 mm dia |
| 46 | 20 mm dia |
| 47 | 25 mm dia |
| 48 | 40 mm dia |
| 49 | 50 mm dia |
| 50 | Refixing of old steel tubing and connection in new or old position including cutting threads if required, fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches, floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:- |
| 51 | 15 mm dia |
| 52 | 20 mm dia |
| 53 | 25 mm dia |
| 54 | 40 mm dia |
| 55 | 50 mm dia |
| 56 | Supply and laying steel water tubing medium grade, galvanised with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches, fixed to wall and ceilings and testing for leakages complete all as specified and directed for the following sizes:-Note : (a) Excavation and Earth work shall be measured and paid separately. |
| 57 | 15 mm dia |
| 58 | 20 mm dia |
| 59 | 25 mm dia |
| 60 | 40 mm dia |
| 61 | 50 mm dia |
| 62 | Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:- |
| 63 | 15mm dia bore |
| 64 | 20mm dia bore |
| 65 | 25mm dia bore |
| 66 | 40mm dia bore |
| 67 | 50mm dia bore |
| 68 | M&L drilling and tapping Ductile iron water mains in position for branch connections of following internal dia size complete all as directed at site. |
| 69 | 20 mm bore |
| 70 | S&F in repair straight plain brass ferrules (or connecting screws)screwed both ends of following size dia complete all as directed at site. |
| 71 | 20 mm bore |
| 72 | Supply and fixing in replacement of float valve brass, high pressure with polythene float and fly nut complete screwed for iron pipe of following sizes |
| 73 | 20 mm dia |
| 74 | M&L mild steel as in cross arms bracing supports clamps and back planes fabricated from structural steel section including nut, bolts washers welding welding drilling holes for bolts in any shape and size as indicated or directedand inclusive of one proimer coat one undercoat one finishing coat of aluminium paint complete. paint complete to support the cables all as specified. |
| 75 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 76 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 77 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing intoPVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etcincluding one run ofPVC insulated 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 78 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing intoPVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6.0 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 79 | S & F for sheet metal enclosure MCBDBTPN4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 80 | S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 81 | S & F for sheet metal enclosure MCBDBSPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 82 | S & F for sheet metal enclosure MCBDBSPN12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 83 | S & F MCCBTPN415volts 25 KA suitable for fixing on DB of capacity 63 Amps with extended terminals and including taking down old u/s MCCB\"s complete all as specified and as directed. |
| 84 | S & F MCCBTPN415volts 25 KA suitable for fixing on DB of capacity 100Amps with extended terminalsand including taking down old u/s MCCB\"s complete all as specified and as directed. |
| 85 | S & Ffor metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Ampsincluding removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed |
| 86 | S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 87 | S & Ffor MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable onecomplete all as specified and as directed. |
| 88 | Supply and replacing 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm dia GI suspension wire, one twin core cable of size 10 Sqmmmulti -strand complete all as specified and directed. |
| 89 | Description all as per ser item No 42 above but size 6 sqmm twin core cable. |
| 90 | Description all as per ser item No 42 above but size 4 sqmm twin core cable. |
| 91 | S & F for LED post top lantern (gate light) 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia including removal of old unserviceable one complete all as specified and directed. |
| 92 | Supply and fixing LED lights fitting 1x 40 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old u/s fittings completeall as specified and as directed. Make :-Bajaj, Philips, Havells. |
| 93 | S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including provision of LED bulb 10/12 watts including removal of old unserviceable onecomplete all as specified and as directed. Make-Havells, Philips, Bajaj. |
| 94 | S & F forLED 10 watts batten aluminium extruded (mirror light) with decorative end capsincluding removal of old unserviceable one complete all as specified and as directed. Make- Bajaj, Havells, Philips. |
| 95 | S & F forEnergy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired andnecessary mounting arrangements , provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and including removal of old unserviceable one complete all as specified and as directed. Make :-Bajaj , Philips, Havells. |
| 96 | S&F Garden Light/ Bollards 10 W IP 65 are made of extruded Aluminium, profiles with cast aluminium base,opal PC diffusers with integrated LED and driver fixed in proper cemented base including removal of old unserviceable one complete all as specified and directed. Make:- Crompton Cat Ref No LBLSN-10-CDL or its equivalent inPhillips/Havells |
| 97 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable size including removal of old unserviceable one complete all as specified and as directed. Make :-Bajaj , Philips, Havells. |
| 98 | S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium ip 66 for building security light fitting luminare with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangement and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting complete all as directed by Engineer-in-charge.Make:- Bajaj, Philips, Havells |