Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Material and labour for cutting of metallic road/ hard standing/hard rock/wall up to a size not exceeding 20cm widthand not exceeding 60cm in depth for laying ofprotection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate upto existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface including suitable size of GI pipe (if necessary)complete all as specified and as directed by Engineer-in-charge.Note: 1. If damaged/broken the any type of tiles while removing, the contractor shall replace the broken tiles with new one.2. The Quoted rate is included for all materials/T&P/Machinery used in this item, no material can paid/measured separately.3. All the removable tiles/re fixable material shall kept carefully at a safe place for refixing with in this quoted rate.4. GI Pipe shall measured and paid separately under relevant item. |
| 2 | Boring of holes under road, pavement, hard standing by adopting horizontal boring including supply and inserting of HDPE pipe of 100 mm dia not less than 6kg/cmworking pressure confirming to IS allas specified and directed. Note: Depth will not be less than 1.00 M below the road pavement and hard standing boring shall be carried out without damaging the road and hard standing. |
| 3 | Material and labour plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate for foundations / filling around the post, Poles etc complete all as specified and as directed. |
| 4 | Servicingto LT panels/Feeder pillar boxescomprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checkingthe seviceability ofindividual items,identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc all as directed Note:-(1) Unserviceable parts replaced if any shall be measured & paid seperately under respective items. |
| 5 | Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size |
| 6 | Painting of LT panel board/feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc complete all as specified and directed. |
| 7 | Rewiring the LT cubical type panel by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,after taking out the old unserviceable wiring all as directed. |
| 8 | Material and labour for replacement of LED type indicator lamp (RYB)(Set of three) complete all as specified. |
| 9 | Suupply and Fixing in replacement of Digital Amp Meter 0-250 Ampwith including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 10 | Suupply and Fixing in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 11 | Supply and fixIndoor resin cast ring type low tension current transformer 50/5A to 75/5A15VA burden accuracy class 1 confirming to IS 2705 /1992 |
| 12 | Supply and fix Indoor resin cast ring type low tension current transformer 100/5A to 300/5A15VA burden accuracy class 1 confirming to IS 2705 /1992 |
| 13 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA |
| 14 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA |
| 15 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 25 KA |
| 16 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA |
| 17 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA |
| 18 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA |
| 19 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA |
| 20 | Supply & fix in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25 x 4 mmas earthing lead by means of bolts,nuts,chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1,RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron 40x40x5mm frame,GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - (i)On testing after completion of earthing,if desired earth resistance is not obtained,the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.(ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip.(iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 25x4 mm. |
| 21 | Material and labour for GI earth strip of size 25 x3mm in ground not exceeding 40cm deep /fixing to wall / structure including taking down old strip complete all as specified and as directed. |
| 22 | Supply and installation, testingand commissioning in replacement of Out Door type LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93 double door floor mountingweather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400 Amp three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. sheet front and back door openable type and conforming to IP-54 and fixed on angle iron frame/channel of suitable size complete, aluminium bus bar chamber, cable alley, cable glands brass / chromium plated of diffrent sizes suitable for incoming and out going cables,panel painted with powder coated paint (LT panel shall be of CPRI approved manufacturer) incuding necessary PCC (1:3:6) foundation extending 600mm above GL and complete all specified and directed by Engineer-in-Charge withthe following accessories:- Note :(i)Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (ii) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (iii)The rates shall be deemed to includes the cost of keeping the surface clean and levelled all arround the Feeder piller box and provide INCOMING (a) Aluminiumbusbar of capacity 600 Amps with eppoxy insulated supports 3 phase and neutral -1 set (b) MCCB 400 Amps 4 pole 36 KA with adjustable type - 01 No (ICS = 100 ICU)(c ) Volt meter digital type 96 sqmm with in built selector switch - 01 set (d) Amps meter digital type 96 sqmm with CT\"s 400/5 -03 Nos and in built selector switch - 01 Set(e) Indicating lamp set LED type - 01 setOUTGOING (b) MCCB 200 Amps, 4 Pole 36KA adjustable type - 5 Nos (c) MCCB 63 Amps, 4 Pole 25KA fixed type - 04 Nos |
| 23 | Supply and installation, testingand commissioning in replacement of LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93,outdoor type, double door floor mountingweather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400 Amp three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. sheet front and back door openable type and conforming to IP-54 and fixed on angle iron frame/channel of suitable size complete, aluminium bus bar chamber, cable alley, cable glands brass / chromium plated of diffrent sizes suitable for incoming and out going cables,panel painted with powder coated paint (LT panel shall be of CPRI approved manufacturer) incuding necessary PCC (1:3:6) foundation extending 600mm above GL and complete all specified and directed by Engineer-in-Charge withthe following accessories:- Note :(i)Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (ii) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (iii)The rates shall be deemed to includes the cost of keeping the surface clean and levelled all arround the Feeder piller box and provide INCOMING (a) Aluminiumbusbar of capacity 600 Amps with eppoxy insulated supports 3 phase and neutral -1 set (b) MCCB 400 Amps 4 pole 36 KA with adjustable type - 01 No (c ) Volt meter digital type 96 sqmm with in built selector switch - 01 set (d) Amps meter digital type 96 sqmm with CT\"s 400/5 -03 Nos and in built selector switch - 01 Set(e) Indicating lamp set LED type - 01 setOUTGOING (a) (b) MCCB 320 Amps, 4 Pole 36KA adjustable type - 2 Nos (c) MCCB 250 Amps, 4 Pole 36KA fixed type - 02 Nos |
| 24 | Supply and installation, testingand commissioning in replacement of LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93,outdoor type, double door floor mountingweather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400 Amp three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. sheet front and back door openable type and conforming to IP-54 and fixed on angle iron frame/channel of suitable size complete, aluminium bus bar chamber, cable alley, cable glands brass / chromium plated of diffrent sizes suitable for incoming and out going cables,panel painted with powder coated paint (LT panel shall be of CPRI approved manufacturer) incuding necessary PCC (1:3:6) foundation extending 600mm above GL and complete all specified and directed by Engineer-in-Charge withthe following accessories:- Note :(i)Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (ii) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (iii)The rates shall be deemed to includes the cost of keeping the surface clean and levelled all arround the Feeder piller box and provide INCOMING (a) Aluminiumbusbar of capacity 400 Amps with eppoxy insulated supports 3 phase and neutral -1 set (b) MCCB 200 Amps 4 pole 36 KA with adjustable type - 01 No (c ) Volt meter digital type 96 sqmm with in built selector switch - 01 set (d) Amps meter digital type 96 sqmm with CT\"s 200/5 -03 Nos and in built selector switch - 01 Set(e) Indicating lamp set LED type - 01 setOUTGOING (a) (b) MCCB 63 Amps, 4 Pole 16KA adjustable type - 7 Nos |
| 25 | Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for LT panel and including cleaning away all grass, vegetation, saplings, shrubs, undergrowth, area complete all as specified and directed. |
| 26 | Dismantling Asbestos cement 6mm thick(corruga ted, semi corrugated, etc.) sheets in roof coverings including ridge. |
| 27 | S & F, 6 mm thick asbestos cement corrugated sheet fixed with ‘L’ type or ‘J’ type or cranked hook bolts . |
| 28 | Fixing only6 mm thick asbestos cement corrugated sheet fixed with ‘L’ type or ‘J’ type or cranked hook bolts. |
| 29 | Dismantling timber scantling40 sqcm and over in section in any position as in unframed work . |
| 30 | S&F prepainted galvalum alm zink coating GI based corrugated/ semi - corrugated steel sheet 0.50mm thick of an colour having tensile strengthof 550 Mpa as in roof covering fixed with coach screw as per manufacturers instrution complete. |
| 31 | S&FPre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering in ridges,hips, valley gutters,chajjas, drip and straightflashings , fixed with ‘L’ type or ‘J’ type or cranked hook bolts. |
| 32 | Dismantling of wall and ceiling board any thickness/description including cover fillet complete all as specified and as directed. |
| 33 | M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre incl 2mm dia G.I. ( upto 1200 mm length ) adjusting level to Purlins/ Rafter. |
| 34 | M&L for 4mm thicknon asbestos fibre cement building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping. |
| 35 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc1.5 Sqm but n.exc 4.00 Sqm each and removing from site . |
| 36 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n’exc1.5 Sqmand removing from site . |
| 37 | Taking down shutter area .exc 1 sqm but n exc 2 sqm each |
| 38 | Supply and fix for Three Track Sliding powder coated aluminium Window of sizes of Top/Side and Bottom track section of 91.80mm x 31.75mm x 1.20mm thick and Shutter section of sizes 39.40 mm x 17.70mmx 1.20mm thick including joining cleats, beading,locking arrangement, rubber gasket for fixing etc complete with 5.5 mm thicktinted glass & stailness steel wire cloth, 0.36 mm nominal dia of wire and averaging width of aperture 1.40mm and fixed with aluminium wire staples complete . (Make: Hindalco or equivalent). |
| 39 | M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc.complete, of frame size 125 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified |
| 40 | S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, look strike plate etc completed, as spd size of frame 105x 60mm. |
| 41 | S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, in opening as per specification and shown on drg in SSR Part-II 2020 complete all as specified and as directed. |
| 42 | S&F2nd class hard wood 30 mm thick glazed & skelton shutter (any no of pannel) open rebated and prepared to receive glass, gauge etc with sush bar edges to framing plain chamfered or receive glass gauge etc with sash bar edge of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24 (a). |
| 43 | M&L 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides covered with decorative face veneer with lipping / frame to match. |
| 44 | S&F particle board corefactory made solid PVC Moulded door shutter 28 to 30mm thick (stiles) with 2 mm thick Moulded PVC sheet on the front face& 2 mm plain colour PVC sheet on back faces,and with particle Board Core supplying and fixing in frame at site as per specification and drawing. |
| 45 | S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rails, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per specification and shown on drawing in SSR Part-II (2020) . |
| 46 | Dismantling wrought iron or mild steel work of any description not otherwise provided |
| 47 | S&F Rolled sections asin main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirmig to Fe-410-W (Gde-E-250) quality A |
| 48 | S & F 100 mm Butt hinges medium weight medium cold rolled mild steel . |
| 49 | S & F 100 mm Butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 . |
| 50 | S&F 150 mm long aluminium anodised barrel tower bolt of extruded section complete. |
| 51 | S&F of 150 mm size aluminium handles cast type anodised. |
| 52 | S&F of 100 mm size aluminium handles cast type anodised. |
| 53 | S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples . |
| 54 | S&Fstainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples . |
| 55 | Hacking out old broken glass any thickness, size, quality or description, from metal/wooden frame including punching or drilling out old glazing pins and removal of demolished material from site. |
| 56 | S&F 4 mm thicksheet glass, ordinary quality and glazing with oil putty/ glazing pins/spring clips in square n exc. 0.5 sq. m in each pane |
| 57 | All as per item No 56 above butfigured glass pin headed type n.exc 0.50 sqm each complete. |
| 58 | Demolition of brick wk masonry built in cement mortar incldg all quoins arches pillars etc |
| 59 | M & L Brick wk with sub class ‘B’ bricks straight or curved on plan exc. 6m means radius in CM 1:6 |
| 60 | M&L for half brick wall work with old size brick straight or curved on plan to any radius built in cement mortar 1:4 . |
| 61 | Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc . |
| 62 | M&L for rendering 15 mm thick on fair faces of brick work / Concrete /stone surfaces in cement mortar (1:6) making finished even & smooth without using extra cement . |
| 63 | M&L for rendering 15 mm thick on fair faces of brick work / Concrete /stone surfaces in cement mortar (1:4) making finished even & smooth without using extra cement). |
| 64 | Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing ) removing serviciable tile to store & rubbish off the permisses. |
| 65 | M&L, 15mm thick screed bed or bedding layer of mortar in CM (1:6) for lying floor finishes . |
| 66 | M & L10mm thick rendering plastering in Cement Mortar 1:4on fair faces of brick work orconcrete surface to receive wall finishes. |
| 67 | M&L vitrified tiles of any colour/shade 8-10 mm thick area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles . |
| 68 | All as per aboveitem No 67 but on vertical surfaces. |
| 69 | M&L coloured/ printed non-skid joint free ceramic tiles7 to 8 mm thick ( square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in as in floor etc.set & jointed in neat cement slurry & pointed in white cement to match . |
| 70 | All as per item No 69 abovebut on vertical surfaces. |
| 71 | M&L for coloured glazed ceramic tiles in vertical surface 350x250x7mm/450x350xx7mm thick set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces |
| 72 | Taking up or down 15mm dia steel tubing and connection including cleaning for re-fixing or removal from site. |
| 73 | S/F for 20mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 74 | S/F for 25mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 75 | Dismantling water tanks Capacity in Exc 500 & n exc 1000litres and removing to store |
| 76 | S & F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) Capacity in 1000 litres hoisted and fixed in position all as specified in SSR Part I |
| 77 | S&F 20mm bore PVC Ballvalves, high pressure, with polythene float & steel rod & fly nut complete, screwed for iron pipe or brass ferrule. |
| 78 | Taking down eaves gutters and rainwater pipes (any sizee or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) |
| 79 | S&F PVC (SWR)pipes 110 mm single socketed in any length with rubberring joints, laid in trenches or in floors |
| 80 | S&F, 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in treches or in floors. |
| 81 | S&F PVC bends any radius 100 mm dia |
| 82 | S&F in repair PVC bends any radius 75 mm dia |
| 83 | S & F75 mm bore size PVC (SWR) junction single, (Single T) equal or unequal |
| 84 | S & F 110 mm bore sizePVC (SWR) junction single, (Single T) equal or unequal |
| 85 | S & F in repair vitreous china wash hand basin,counter sunkwhite flat back of size 550 mm x 440 mm including brackets and making necessary arrangement for fixing. |
| 86 | S&F in repair vitreous china pedastal type water closet, white (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete and making good to floor. |
| 87 | S&F, in repair 10ltr capacity PVC low level flushing cistern, white inlet ball valve, float and handle and connection to pipe including bracket . |
| 88 | S&F in repair, 450mm long, 15mm dia, PVC connection pipe, with brass unions on both ends. |
| 89 | S & F in repair, 15 mm bore bib taps, chromium plated cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule. |
| 90 | S&F in repair 15 mm bore angle/ stop valves , fancy type chromium plated with long shank and cup (conceaeld type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as spfd & directed by Engr-in-charge. |
| 91 | S&F 32mm flexible pipe for urinals and wash basin. |
| 92 | S&FFlush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern |
| 93 | S&F in repairs of 15 mm pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"hot\" or \"cold\" with long screwed shanks and fly nuts, screwed for iron pipe. |
| 94 | S&F in repairEWC sheet cover to match EWC complete. |
| 95 | S&F in repairs Health fauset (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meterlong flexible tube and ABS wall hook incl making connections and fixed in position complete in all respect as specified. |
| 96 | S&F CP soap tray fixed with rawl plugs complete. |
| 97 | Supply and fix PVC connections 15 mm size with PTMT nuts of length 900mm. |
| 98 | M&L for preparation of new plasterd wall surfacesand applying two coat of oil bound distemper of approved colour and shade over one coat putty . |
| 99 | M&L for preparation of old decorated surfaces on walls and applying one coat of oil bound distemper of approved colour and shade |
| 100 | All as per above item No 99 but two coats of oil bound distemeper. |
| 101 | M&L for preparation of new plasterd wall surfaces and applying two coat of cement based paint of approved colour and shade |
| 102 | M&L, for preparation of old decorated surfaces on walls brooming down or steel wire brushing, scrapping down smokes sootmoulds, moss and efflorescent salts and trading oil and greasy spot & applying one coat of cement base paint complete all as specified and as directed. |
| 103 | M&L for preparation on new wooden surfaces of any description not otherwise described over 10 CM width or girth and applying two coat of synthetic enamel paint of approved colour and shade over pink primer. |
| 104 | M&L for preparation on new steel surfaces of any description not otherwise described over 10 CM width or girth and applying two coat of synthetic enamel paint of approved colour and shade over red oxide zinc chrome primer. |
| 105 | M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint of approved colour and shade |
| 106 | M&L for preparation of old painted steel or iron surfaces of any description not otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint of approved colour and shade |
| 107 | M&L for applying Two or more weather coats of 100% premium acrylic emulsion paint having, Alkali & fungal resistance, dirt resistance exterior paint of required shade and including priming coat of exterior primer after complete removal of existing treatment on wall surfaces. |
| 108 | Taking out defective submersible pump set installed at 200-400 feet depth including disconnecting electric connections, removing submersible cable, GI column pipe, safety rope, and all accessories using tripod/winch/chain pulley/Hydra arrangement, servicing and repair of submersible pump capacity upto 15 HP including dismantling of pump and motor, cleaning of impellers, shaft alignment, greasing, replacement of gasket set, gland packing, minor hardware, and reassembly and transporting the defective borewell to workshop. after repairlowering and re-installation of repaired submersible pump set back to 200–400 feet depth including lowering of GI pipe column/PVC pipe, submersible cable, clamp arrangement and reconnection of starter suitable for the rating of existing submersible pump, including wiring connections. After installation, the system shall be tested including megger test of cable and motor, running and load current check, leak testing, discharge verification and handing over the system in fully satisfactory operational condition complete as directed by Engineer-in-Charge.Note:(a) Unit rate quoted shall deemed to include only labour for taking up & lowering the submersible pump from bore well along with delivery pipe complete(b) Repairs/rewinding of submersible pump shall be measured & paid for separately under relevant items.(c)Replacement of colummn pipe will be measured and paid for separately as supply only, under relevants items. (d) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation from site to work shop and back are deemed to be included in rate quoted |
| 109 | M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :- |
| 110 | Submersible Motor up to and including 5 HP. |
| 111 | Submersible Motor above 5 HP up to 10 HP. |
| 112 | Submersible Motor above 10 HP up to 15 HP. |
| 113 | Supply, installation, commissioning and testing of submersible pump & motor set, electric driven, 415V, TP suitable for 200 mm dia borewell (casing pipe size 200 mm) supplied and installed complete 7.5 HP, complete all as specified and directed. |
| 114 | Supply and fix 1HP booster pump single phase maximum head 42 meter discharge section and delivery 25mm copper winding maximum recommended pressure 3.8 bar complete all as specified and as directed. |
| 115 | M & L in replacement for GI pipe heavy grade 50mm dia, cut into 3.0 mtr length including providing of threading on both sides and lowering into the existing bore well along with existing GI pipe for increasing the length of the borewell pipe as in repairs complete all as specified and directed. |
| 116 | Supply and fixing in replacement and water proof submersible cable3 core copper conductor, PVC insulated 1100 volts grade 2.5Sqmm protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified and as directed. |
| 117 | Taking out the open well pump set with motor from the from UG Sump existing foundation for carrying out necessary repair/servicing by replacing the unserviceable parts including fixing of new coupling (CI/rubber) as per existing upto 25 HP to 50 HP capacity, at site and refixing at same location incl aligning and commissioning, complete all as specified and directed. |
| 118 | M&L for rewinding the open wellMotor open well Motor up to and including from 25 to 40 HP with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor. |
| 119 | Dismantling and taking out the centrifugal pumping set with motor from the existing foundation for carring necessary repair/ servicing by replacing the unservicable partsincluding overhauling the pump set, renewal of gasket to pump, suction and delivery lines, gland packing, greasing nuts, bolts and washers, re-connecting up of the electric / water connections, including fixing of new coupling (CI/rubber) as per existing all as required at site of work of capacity upto 40 HP, including re-fixing at same location including aligning and commissioning complete all as specified and directed.Notes:- (i) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing etc., and transportation from site to work shop and back are deemed to be included in unit rate quoted.(ii) Labour element is deemed to be included in unit rate quoted. |
| 120 | M&L Dismantling and strip opening the motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete servicing the motor assembly including cleaning the carbon deposits with carbon tetra chloride, greasing the bearings etc., heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the moisture evaporates complete at authorized workshop including transportation and refit the same after repairs and re-connecting up of the electric connections including testing and commissioning complete all as specified and directed for the following capacities:- |
| 121 | All as per item no 117 above for Induction Motor 100 HP capacity. |
| 122 | All as per item no 117 above for Induction Motor 40 HP capacity. |
| 123 | M&L cutting and taking out the unserviceable / burnt out copper winding from the electric motor, preparation of the surface and rewinding the same with super enamelled copper conductor with ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly with necessary insulating materials complete all as specified for the capacities upto 100 HP motor |
| 124 | Supply and fix Ball bearing in replacement for electric motor of capacity 100 HP, 3 Phase as per existing make and model complete all as specified and directed. |
| 125 | Supply and fix Ball bearing in replacement for electric motor of capacity 40 HP, 3 Phase as per existing make and model complete all as specified and directed. Make : Hindustan Brown Breware and equivalent |
| 126 | Supply and fix Ball bearing in replacement for electric motor of capacity 7.5 HP, 3 Phase as per existing make and model complete all as specified and directed. Make : Hindustan Brown Breware and equivalent |
| 127 | Supply and fixing in replacement of power contactortype ML-6 complete all as specified and directed. |
| 128 | Supply and fixing in replacement of power contactortype ML-3 complete all as specified and directed. |
| 129 | Supply and fixing in replacement of power contactortype ML-1 complete all as specified and directed. |
| 130 | Supply and Fix Copper lugs of different capacity and size as directed and specified by engr-in- charge. |
| 131 | M&L Stainless steel nut, bolts and washers of different sizes as directed and specified by engr-in- charge. |
| 132 | Supply only LT tape fire resistanttype complying IS 7809, 1.8 cm width & 25 mtr length all as directed and specified by engr-in- charge. |
| 133 | Taking down MCCB by disconnecting all connections very carefully of any size and capacity and complete all as specified and directed at site by Engr-in-charge. |
| 134 | Supply and fix in replacement MCCB 4 Pole 415 volts 400 Amps 50 Hz Thermal magnetic adjustable type, with breaking capacity 36 KA complete all as specified and directed at site. |
| 135 | Supply and fix in replacement MCCB TPN 415 volts 250 Amps 50 Hz Thermal magnetic adjustable type, with breaking capacity 36 KA complete all as specified and directed at site. |
| 136 | Supply and fix in replacement MCCB TPN 415 volts 125 Amps 50 Hz Adjustable type, with breaking capacity 25 KA complete all as specified and directed at site. |
| 137 | Taking down/disconnecting the existing Star Deltastarter of Centrifugal / submersible pump from motor control panels of various pump houses and replace with new Star delta starter of capacity 10 HP to 25 HP, three phase, including making electric connection, complete all as specified and directed. |
| 138 | S&F in replacement 3 phase 415 Volts, submersible pump controller MU-G6 (5 HP - 7.5 HP DOL) or 3 seat enclosure with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic rating 14 Amps, relay range 9 to 14 Amps, including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed. |
| 139 | M&L for spray painting (two coat of synthetic enamel paint) on centrifugal pump & motor of any capacity rating 10-200 HP, scratching the rusted and suction/delivery pipe line including NRV and sluice valve, MS Base chanel complete all as specified and as directed. |
| 140 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthstripof size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I filling with charcoal dust , and common salt,including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EICNote :(i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate. |
| 141 | S&F GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail