| 1 | Surface excavation in soft/loose soil, n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out, complete all asdirected. |
| 2 | Excavation in trenches n.exc. 1.5 m width and n.exc. 1.5 m in depth for foundation, laying of UG cable, pipe etcin soft/loose soil & getting out, complete all as directed. |
| 3 | Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 4 | Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all asdirected. |
| 5 | Surface dressing in soft loose soil n exc 15 cm deep and getting out, complete all asdirected. |
| 6 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil & getting out, complete all as directed. |
| 7 | Excavating over areas, exc 1.5 m and not exc 3.00 m deep and getting out soft/loose soil & getting out, complete all as directed. |
| 8 | M&L plain cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 9 | M&L plain cement concrete type C-2 (1:3:6) using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 10 | S&F Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe.290. Gde-E-165 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. complete all as specified and as directed. |
| 11 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in cement mortar 1:6complete all as specified and directed. |
| 12 | M&L RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and directed. |
| 13 | M&L Pre-cast cement concrete block masonry using Type B1 1:2:4 (20 mm graded aggrgate) with solid blocks, exc. 10 cm in width and setting in mortar,1:6 complete complete all as specified and directed. |
| 14 | M&L Pre Cast RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate cover slab as in drain cover, manhole cover, etc, set in cement mortar 1:6 complete all as specified and directed. |
| 15 | M&L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, banding spirally for hooping columns, hookingend and binding with and includingmild steel wire not less than 0.90 mm dia (annealed) complete all as specified anddirected . |
| 16 | M&L mild steel TMT bar 5 mm dia and over upto and including 10mm dia in strrups as inincluding cutting, bending and binding with and including mild steel not less than 0.9 mm dia (annealed)complete all as specified anddirected . |
| 17 | M&L Formwork to faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed. |
| 18 | M&L for Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 19 | M&L rendering 20mm thick with cement mortar 1:4on fair faces of brick workin two layers (10mm and 10mm) sperately mixed withand including water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L 75mmthick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 21 | M&L Hardcore of gauge n exc. 63 mm, Broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface,complete all as specified and directed. |
| 22 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 23 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 24 | S&F 2000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), complete in all as specified and as directed. |
| 25 | S&F 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 26 | S&F 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 27 | M&L for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 28 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 29 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in vertical surfaces, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick Screed bed or bedding layer of cement mortar 1:4,for laying floor finishes, complete all as specified and directed. |
| 30 | M&L Glazed ceramic coloured tiles in vertical surfaces 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 31 | M&L Glazed ceramic coloured tiles in vertical surfaces 300x 200x 7 mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 32 | M&L Sand filling under floors or in foundations including watering and conosoldiation complete all as specified and directed. |
| 33 | M&L Concrete bed to drain pipes of 150mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested; in 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed. |
| 34 | Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed. |
| 35 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 36 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 37 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 38 | Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out in soft/loose soil and removing debries not exceeding 50 metre and depositing where directed complete all as directed. |
| 39 | M&L 100mmthick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 40 | S&F 110mm bore UPVC (SWR) heavy duty soil waste drain pipeconforming to IS 13592, single socketed, in any length with rubber rings laid in trenches complete all as specified and as directed. |
| 41 | S&F 150mm bore UPVC (SWR) heavy duty soil waste drain pipeconforming to IS 13592, single socketed, in any length with rubber rings laid in trenches complete all as specified and as directed. |
| 42 | S&F 150mm bore UPVC (SWR) bends any radius complete all as specified and as directed. |
| 43 | Cutting into existing manholes for connecting new drains,150mm bore making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required |
| 44 | M&L Heavy duty vitrified coloured tiles 600mmx600mmx16mm thick in floors etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed. |
| 45 | Cutting holes in brick walls built, in cement mortar superficial area wxc 150sqcm but not exc 400sqcmasrequired and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and directed. |
| 46 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 47 | S&F framed work as in wind Tie and similar work confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 48 | S&F Rolled mild steelas inFramed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 49 | S&F 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 50 | Planting/Grassing with Doob Grass No.1 quality (Fresh and good quality as approved) area of plantation of grass with sectional rows having distance 7.5cm apart both ways and watering including surface excavation of earth not exc 30cm deep and averaging 15cm deep including cleaning away all grass, vegetation, shurbs, roots of trees and removing rubbish off the permises complete all as directed.Note:- (i) Supply and mixing of manure/Cow dung with excavated earth, surface dressing of the area to a true level and required slope for grass plantation, extra earth required if any shall be deemed to inclusive in the Unit rate Quoted.(ii) Maintance of one year from certified date of completion is deemed to be inslusive in the in the Unit rate Quoted. |
| 51 | Planting of the following tree species 2 to 2.5 years old with proportional girth and of ever green and or shady species including preperation of plant bed, digging holes, mixing with manure/cow dung including watering, manuring and maintance for one years for the followings:- |
| 52 | Jasmine |
| 53 | Bottle Brush |
| 54 | Silver Oak |
| 55 | Royal Palm |
| 56 | Ashoka |
| 57 | Campus |
| 58 | Bugenella |
| 59 | Lechi with seed |
| 60 | Lechi without seed |
| 61 | Bettel Nut |
| 62 | Jamun |
| 63 | M&L preparing surfaces for hedging by taking out wild grass etc and planting necessary plants and flowers, putting manure etc as required including maintance for one years complete all as directed |
| 64 | Provision of bamboo tree guard, height not less than 1.5 meter from GL, spacing of bamboo not less than 150mm center to center (thickness of bamboo splits not less than 10mm) complete all as directed.Note:- (i) Bamboo used shall as approved |
| 65 | M&L for Brickwork with burnt old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 66 | M&L 50mmthick cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate as in floor finished even and fair without using extra cement complete all as specified and directed. |
| 67 | M&L Pre polished chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over cement screed 15 mm thick in cement mortar 1:6 complete allas specified and directed. |
| 68 | S&F stone clading in walls with flat natural stone of size not exc 30cm fixed in regular shape or course and pointed in cement mortar 1:4complete all as specified and directed. |
| 69 | M&L plain cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 70 | S&F 600mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed. |